HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW FIXED41 ' 2018
4 F
BCIS Home { Log in I user Registration Hot Topics
Florida. Building Code Online
� 4—� I�� L� ! •ti <LF Ir I6�1
4
1
_db
a�{{t��'I : Rroduct A rovall - �, } 'iaR USER: Public P er fi�C GHO Homes Corp
+�'
"�'�
Product Approval Menu > Product or Application Search > Appllcadon Llst > Application Detail 2680 Conifer Drive
Meadowood lot 50
FL # FL15349-R10 permit # 1802-0549
Application Type Editorial Change
Code Version 2017 -
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
the POC and/or the Commission If necessary.
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
MI Windows and Doors
650 West Market Street
Gratz, PA 17030
(717)365-3300 Ext2560
bsitlinger@miwd.com
Brent Sitlinger
bsitlinger@miwd.com
Windows
Fixed
Certification Mark or Listing
American Architectural Manufacturers Association
Steven M. Urich, PE
,-'' Validation Checklist - Hardcopy Received
Standard
AAMA 506
AAMA/WDMA/CSA 101/I.S. 2/A440
Method 1 Option A
AT
Date Submitted 03/26/2018
Date Validated 03/26/2018
Date Pending FBC Approval
Date Approved 03/27/2018
https:/Avww.floridabuilding.org/pr/pr app_dtl.aspx7param=wGEVXQwtDgtH8572gvdWIanDWDAgM3ZOzPaVM WItjJjQ2eoVzFgSEw?/o3d%3d
Year
2011
2008
1/3
4/24/2018
i
i
,
Florida Building Code Online
Summary of Products
FL #
Model, Number or Name
Description
15349.1
185 PW
73 x 72 Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FLIS349 R10 C CAC APC 12786,12787.pg
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
04/03/2023
Design Pressure: +60/-60
Installation Instructions
Other:CW-PG60
FL15349 R10 II 08-02357B.pd
Verified By: Luis R. Lomas, PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FLIS349 R10 AE 513124B.od
Created by Independent Third Party: Yes
15349.2
185 PW
159 x 54 Triple CHS Insulated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15349 R10 C CAC APC 15350.E
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No
01/24/2021
Design Pressure: +55/-55
Installation Instructions
Other:R-PG55
FLIS349 RIO II 08-02949.12d
Verified By: Luis R. Lomas, PE 62514
Created by Independent Third Party: Yes
Evaluation Reports
FLIS349 RIO AE 513783.odf
Created by Independent Third Party: Yes
15349.3
185 PW Impact
72 x 72 Insulated Laminated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FLIS349 RIO C CAC APC 15454.W
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
06/25/2021
Design Pressure: +55/-55
Installation Instructions
Other, FW-LC55, Missile Level D, Wind Zone 3. Glass
FLIS349 RIO II 08-02948.12df
consisted of 5/32" tempered exterior - spacer - 5/32" annealed
Verified By: Luis R. Lomas, PE 62514
/ 0.100 Solutia Saflex HP / 5/32" annealed. Glass was bedded
Created by Independent Third Party: Yes
In Pecora 896 silicone with 5/8" glass bite.
Evaluation Reports
FLIS349 R10 AE 513782,M9
Created by Independent Third Party: Yes
15349.4
185 PW Impact
159 x 54 Triple CHS Insulated Laminated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FLIS349 RIO C CAC APC 8272.E
Approved for use outside HVHZ: Yes
FLIS349 R10 C CAC APC 8273.pdf
Impact Resistant: Yes
Quality Assurance Contract Expiration Date
Design Pressure: +55/-55
01/24/2021
Other: FW-R55, Missile Level D, Wind Zone 3. Glass consisted
Installation Instructions
of 1/8" annealed exterior - spacer - 3/32" annealed / 0.090
FLIS349 RIO II 08-01614121.29f
Solutia PVB / 3/32" annealed. Glass was bedded In Pecora 896
Verified By: Luis Roberto Lomas 62514
silicone with 5/8" glass bite.
Created by Independent Third Party: Yes
Evaluation Reports
FLIS349 R10 AE 512278B.Pdf
Created by Independent Third Party: Yes
15349.5
185 PW Impact
96 x 60 Insulated Laminated Glass
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: No
FL15349 RIO C CAC APC 7962.E
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
12/05/2020
Design Pressure: +55/-55
Installation Instructions
Other: FW-LC55, Missile Level D, Wind Zone 3. Glass
FL15349 Rio II 08-01613B.Rd-
consisted of 5/32" annealed exterior - spacer - 5/32" annealed
Verified By: Luis Roberto Lomas 62514
/ 0.100 Solutia Saflex HP / 5/32" annealed. Glass was bedded
Created by Independent Third Party: Yes
In Pecora 896 silicone with 5/8" glass bite.
Evaluation Reports
FL15349 RIO AE 512277B.pAf
Created by Independent Third Party: Yes
back Next
Untact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: BSG-487-1824
The State of Florida IS an AA(EEO employer. Q2ytight 2007-2013 State of Florida.:: PrNacv statement :: AccesslblllN Statement :: Refund Statement
https:IANww.floddabuilding.org/prlpr app dtl.aspx7param=wGEVXQwtDgtH8572gvdWianDWDAgM3ZOzPaWWWIqJjQ2eoVzFqSEwa/03d%3d 2/3
4/24/2018
Florida Building Code Online
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic
mall to this entity. Instead, contact the officeby phone or by traditional mall. If you have any questions, please contact 850.487.1395. 'Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address ef they have
one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal
address, please provide the Department withanemail address which can be made available to the public. To determine If you are a licensee. under Chapter 455,.F.S.,
please click here .
Product Approval Accepts:
0 501109 M
Credit Card
Safe
https://www.tloridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgtH8572gvdWianDWDAgM3ZOzPawwWItjJjQ2eoVzFqSEw%3d%3d 3/3
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH
REQUIREMENTS OF THE FLORIDA BUILDING CODE.
2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE
RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL.
4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE
ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURER'S PUBLISHED
INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO
MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL.
5. WHERE WOOD BUCK THICKNESS IS 1-1/2' OR GREATER. BUCK SHALL BE SECURELY
FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY
BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH
MANUFACTURER'S PUBLISHED INSTALLATION INSTRUCTIONS.
6. WHERE IX BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED
COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF
THE ARCHITECT OR ENGINEER OF RECORD.
7. BUCKS SHALL EXTEND BEYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS
PROVIDED.
8. SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE
SPACE OF 1/16- OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4".
9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE
OF SUSTAINING APPLICABLE LOADS.
10. WIND LOAD DURATION FACTOR Cd=1.6 WAS USED FOR WOOD ANCHOR CALCUI.ATIONS.
11. FRAME MATERIAL: ALUMINUM 6063-T5.
12. UNITS MUST BE GLAZED PER ASTM E1300-04/09. SEE SHEET 3 FOR GLASS DETAILS.
13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REOUlREO FOR THIS PRODUCT IN WIND
BORNE DEBRIS REGIONS.
14. FOR ANCHORING THROUGH FIN INTO WOOD FRAMING OR 2X BUCK USE #6 WOOD SCREWS
WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4` MINIMUM EMBEDMENT INTO SUBSTRATE.
LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
TABLE OF CONTENTS
NO. DESCRIPTION
1 NOTES
2 - 3 ELEVATIONS & GLAZING DETAILS
4 - 12 INSTALLATION DETAILS
REVISIONS
DESCRIPOON MR; --0VEO
REVISED INSTALLATION DETAILS 05/12/15 R.L.
REMOVED MONOLITHIC CLASS 08/12/16 R.L.
15.FOR ANCHORING THROUGH FRAME INTO WOOD FRAMING OR 2X BUCK USE N10 WOOD
SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4- MINIMUM EMBEDMENT INTO
SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
16. FOR ANCHORING THROUGH FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH
SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2
1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND
INSTALLATION DETAILS.
17. FOR ANCHORING THROUGH FRAME INTO METAL STRUCTURE USE #10 SMS OR SELF
DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND
STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION
DETAILS.
18. ALL FASTENERS TO BE CORROSION RESISTANT_
19. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR
MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN
SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42
B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI.
C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90. GRADE N. TYPE I (OR GREATER).
D. METAL STRUCTURE: STEEL 18GA. 33KSI OR ALUMINUM 6063-T5 1/8` THICK MINIMUM
20. GEOMETRIC SHAPES ARE ALSO APPROVED. APPROVED GEOMETRIC SHAPES DIMENSIONS
SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN
IN SHEETS 2 AND 3.
SIGNED. 1110312016
MI WINO oWw. MARKETDOORS, LLC ST.``���`g It- 2p�
GRATZ. PA 17030Ai
v v�GENSFq�p'i�
185 PICTURE WINDOW *�
96" X 6 IMPACT +,o ff_
NOTES � _ TAT OF m
V.L 1 08-01613
scut NTS 104TE 06/04/12 1 SKEU 1 OF 12
L ROBERTOLOMAS PZ I Luis R. Lomas P.E.
L4WN000FORORDLh'KWTLE,IV027021 FL No.: 62514
pr4E68Ofi09 rf�nut�8kmassoamel
2' MAX.
185 FIXED WINDOW
EXTERIOR VIEW
FLANGE& FINLESS INSTALLATION
95 1/2' MAX. FRAME WIDTH -
2' MAX. 12' MAX O.C.
/
/
/
185 FIXED WINDOW DESIGNER
EXTERIOR VIEW
FLANGE & FINLESS INSTALIA17ON
DESIGN PRESSURE R477AIG
WACT RATING
t55OPSF
LARGEANDSM LL
MISSILE FMPACT
MISSILELEVEL D. WINDZONE3
2' MAX.
T 2' MAX
I
14'
f2'
IE
HT
SEE CHARTS
#1 AND #2
FOR NUMBER
OF ANCHORS
REOUIRED
2 MAX_
2' MAj( 1
12• 59 1/2"
MAX O.C_ MAX._ FRAME
HEIGHT
SEE CHARTS
$1 AND 02
FOR NUMBER
OF ANCHORS
REQUIRED
REVtSKM
REV
DESCRIPTION
DATE
APPROVED
A
REVISED INSTALLATION DETAILS
1
1
05/12/15
R.L.
B
REMOVED MONOLITHIC GLASS
08/12/16
R.L
r•.h..• e4
Number ofandws locations required ffor units without dgfd fillers
Holaht
Wbldow width
(in)
(in)
30.0 36.0 420 Id.O St.0 60.0
6&0 7zo 7&a a" 90.0 V&S
H65
H&S
mb
H&S
Jamb
H&S
Jamb
H&S
Jamb
H&SIlamb
HW
IJAMbI
H&S
WaMb
H&S
Jamb
HLS
J#Mb
H&S
Jamb
H&S
amb
H&S
Jambi
H&S
Jamb
24.0
3
3
3
3
4
3
4
3
4
3
5
3
5
3
6
3
6
3
7
3
7
3
7
3
8
3
30.0
3
3
3
3
!
J
!
3
4
3
5
3
5
3
6
3
6
3
7-
3
7
3
8
3
8
3
3&0
3
4
3
4
4
!
4
!
4
4
5
4
5
4
6
4
7
4
7
4
8
4
9
4
9
4
420
3
!
3
4
4
4
!M44
5
4
8
47
4
7
!
81
9
4
10
4
714LO
3
4
3
4
4
4
5
4
8
4
7
4
8
4
9
4
10
4
11
4
125
3
5
4
5
4
5
5
8
57
5
8
S
9
5
10
5
11
5
125
3
5
4
5
4
5
6
6
6
7
6
9
6
10
6
10
6
11
6
72
6
tl arr 02
Number of anchors locations required for units with rfgfd Bfiers
Holaht
Window
width
(in)
(in)24.0
30.0 36.0 42.0 5"
6&0 720 MO 6L0 90.0 NJ
H&S
Jambi
H&S
IJambI
H&S
Jamb
H&S
Jambi
H&5
Jamb
H&S
Jambi
AILS
11amb
H&S
Jambi
HaS
Wamb
H&S
Jambi
H&S
Jambi
H&5
IJ&mbI
HAS
Jamb
240
3
3
3
1 3
1 4
3
4
3
4
3
5
3
5
3
6
3
6
3
7
3
7
3
7
3
6
3
30.0
3
3
3
3
4
3
4
3
4
3
5
3
5
3
6
3
6
3
7
3
7
3
7
7
5
3
36A
3
4
3
4
4
4
4
4
4
4
5
/
5
4
6
4
6
4
7
4
7
4
7
!
8
4
420
3
4
3
4
4
4
4
4
4
4
5
4
5
1
8
4
6
4
7
4
7
4
7
!
a
4
440
3
4
3
4
4
4
4
4
4
4
5
4
5
1
6
4
6
4
7
4
7
!
7
4
e
4
SaA
3
5
7
5
!
5
4
5
4
5
5
5
5
5
6
5
6
5
7
5
7
5
7
6
9
5
SAS
3
5
3
5
4
S
4
5
4
5
5
5
5
5
6
5
6
5
7
5
7
5
7
S
0
5
NOTES:
1. MAXD.L0.:923(4'X56314'
SIGNED: 11103/2016
LLC
650 W. A�E�
PA
5 ItIL 0 ',?Z?'i
GRATZ, 17030
185 PICTURE WINDOW
�t� �dpyXlFlo
96" X 60" IMPACT
FLANGE &FINLESS ELEVATIONS &CHARTS
a�
�3 TAT OF tr,�
i�'�►•'c[OR101;•�
ORAIM:
Dac Ro.
aflr
08
B
70MA` 1a6���
suLE NTS D"'� 06/04/12 23 OF 12
L ROSMOLCMASA&
1432NOODFOROROLEWiSVIIJANC27623
4744860609 r6arus@0bmas m=n
Luis R. Lomas P.E.
FL No.: 62514
3" MAX.
2" MAX.
185 FIXED WINDOW
EXTERIOR VIEW
RN INSTALLATION
95 1/2" MAX. FRAME WIDTH -
I--H 12" MAX O.C.
/
/
/
/
185 FIXED WINDOW DESIGNER
EXTERIOR VIEW
FW INSTALLATION
DESIGN PRESSURE RATING
IMPACT RATING
t55.OPSF
caRCEANDSMALL
MfSSILE IMPACT
MISSILE LEVEL0, WIND ZONE 3
3" MAX.
/- 3" MAX
12" 59 1/2-
MAX MAX.
O.C. FRAME
SEE CHART #3
FOR NUMBER
OF ANCHORS
REQUIRED
2" MAX.
2" MAX
12"
MAX O.C.
59 1/2"
MAX.
FRAME
HEIGHT
SEE CHART #3
FOR NUMBER
OF ANCHORS
REQUIRED
REVSIONS
Nfl/ gESCR1A00N - APPROVLU
A REVISED INSTALLATION DETAILS 05/12/15 R.L.
B REMOVED MONOLITHIC GLASS 08/12/16 R.L.
Cbad IL7
Number of anchor lomflons mqufmd for ldn lnftflalTon
Frame
Frames w ktth (M
thIghl
24LW
1 30.00
3LL00
1 4200
4L00
scw
60.00
66.00
7200
1 78.W
6L00
90.00
9550
(In)
Has
Jamb
NLS
ftlb
HLS
J..b
HLS
J..b
H65
Jamb
NLS
mb
HW
J..b
HLS
mb
HLS
Iftb
HLS
mb
Has
pamb
HLS
1Amb
HLS
mb
24.00
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
1 6
7
1 7
7
7
a
I 8
a
a
9
9
3ROO
3
3
3
3
4
4
•
•
5
5
5
5
6
6
6
6
7
7
7
6
8
8
a
9
9
3000
3
3
3
3
4
4
4
4
5
5
5
5
6
6
8
677
7
a8a
a
9912.00
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
677
7
8
8
8
8
46.00
3
3
3
3
4
4
4
4
5
5
5
5
6
6
6
6
N
77
7
a88
a
99
Sa003
3
3
3
4
4
4
4
5555666
61
7
7
a
8
a
a
9
959.50
3
3
3
3
44
4
•
S
5
5
5
6
6
6
6
7
7
7
a
a
8
8
9
9
3/4'
5/32" ANN
.100" SAFLEX HP
PVB BY EASTMAN
5/32" ANN
5/32" ANN
EXTERIOR
INTERIOR
SILICONE
#6 x 1 1/4" TEK
SPACED 4" FROM
CORNERS AND 18" MAX
O.C. THEREAFTER GLAZING DETAIL
SIGNED: 11/0=016
MI WINDOWS ANDDOORS, LLC
650MARKET
GRATZ. PA 17030
`�V �.�GEN8E•9�'
185 PICTURE WINDOW
10
NOS:
1. MAXD.L0.:923(4"X56314'
96" X 60" IMPACT
FIN ELEVATIONS AND CHART
=,o �s7.f�r
D"vft arc No.
REV
V. 08-0011613
B
LE NTS w1E 06/04/12 3 OF 12
L ROBERTO LOMA.4P.E
I437 WOODFORD ROLEIISVLM NC27=
4m4w 0609
Luis R. Lomas P.E.
FL No:• 62514
1/2" MIN.
-r EDGE DISTANCE
WOOD FRAMING
OR 2X BUCK 1 1/4' MIN. METAL
BY OTHERS EMBEDMENT STRUCTURE
BY OTHERS
1/4' MAX.
BACKER ROD &
SHIM SPACE
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
APPROVED SEALANT
010 WOOD SCREW
BEHIND FLANGE
INTERIOR
EXTERIOR
910 WOOD SCREW
EXTERIOR
BACKER ROD &
APPROVED SEALANTAl
1/4' MAX.
BACKER ROD &
BEHIND FLANGESHIM
SPACE
APPROVED SEALANT
BEHIND FLANGE
WOOD FRAMING1
OR 2X BUCK
1/4" MIN.
METAL �
BY OTHERS
EMBEDMENT
STRUCTURE
BY OTHERS
1/2"
EDGE DISTANCE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
1 1/4" MIN.
EMBEDMENT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
#10 WOOD
SCREW
1/2' MIN.
EDGE DISTANCE
1/4" MAX.
r SHIM SPACE
INTERIOR
EXTERIOR
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR2X LILICK INSTALLATION
#10 SMS OR
SELF DRILLING
SCREWS
3/4" MIN
EDGE DISTANCE
A 1/4" MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING
SCREW
lNTEAIOR
/— #10 SMS OR
/ SELF DRILLING
SCREW
1/4" MAX.
_F SHIM SPACE
F'
3/4' MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
1 /4" MAX.
SHIM SPACE
INTERIOR
3/4' MIN.
EDGE DISTANCE
MET EXTERIOR
STRUCTURE BACKER ROD &
BY OTHERS APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
REVISIONS
REV DESCRIPTION DATE APPROVED
A REVISED INSTALLATION DETAILS 05/12/15 R.L.
B REMOVED MONOLITHIC GLASS 08/12/16 R.L.
NOTES:
1. INTERIOR AND EXTERIOR RNISHES BY OTHERS.
NOT SHOWN FOR CLARITY.
2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE
DESIGNED IN ACCORDANCE WITH ASTM E2112
MI WINDOWS AND DOORS, LLC
650 W. MARKET ST.
GRATZ, PA 17030
185 PICTURE WINDOW
96" X 60" IMPACT
FLANGE INSTALLATION DETAILS
DRAWN, O= NO.
V.L. 08-01613
07
NTS WTE 06/04/12 s— 4 OF 12
L R08ERTO LOU49 RE
14M WOODFM RD LEWISVW, NO 2=
434-SM-0509 rWrtlf@ftmopeco n
SIGNED. 11/03&016
�Jiv�y�Na�l�:
Luis R. Lomas P.E.
FL No.: 62514
REVISIONS
DESCRIPTION DATE APPROVED
REVISED INSTALLATION DETAILS 05/12/15 R.L.
REMOVED MONOLITHIC GLASS 08/12/16 R.L.
2 1/2" MIN.
EDGE DISTANCE
CONCRETE/MASONRY
1 1/4" MIN.
BY OTHERS
• e
EMBEDMENT
OPTIONAL 1X BUCK �
e
" e• ,
a
1 1/4" MIN.
EMBEDMENT
SEE NOTES 3 - 7
. '
SHEET 1
-�
a
CONCRETE/MASONRY
BY OTHERS
__ 1/4" MAX.
' SHIM SPACE
BACKER ROD
D
1/4" MAX.
OPTIONAL 1X BUCK
& APPROVED
SHIM SPACE
SEE NOTES 3 - 7
SEALANT
SHEET 1
. INTERIOR
3/16" TAPCON
3/16" TAPCON
a
EX MRroR
INTERIOR
3/16" TAPCON
BACKER ROD
2 1/2"
..
& APPROVED
MIN.
EDGE:
a
SEALANT
DISTANCE
EXTERroR
OPTIONAL 1X BUCK
HIM MAX'
SHIM SPACE
L_
BACKER ROD
SEE NOTE 3 — 7
SHEET 1
& APPROVED
SEALANT
CONCRETE/MASONRY
JAMB INSTALLATION DETAIL
BY OTHERS
' e f n •.
1 1/4" MIN.
CONCRETSMSONRYWSTALLA77ON
EMBEDMENT
d e.
SIGNED: 1 i/03r1016
2 1/2- MIN.
EDGE DISTANCE
MI WINDOWS AND DOORS, LLC
VERTICAL CROSS SECTION
650 W. MARKET ST.
`����iutun��/
R�• p4JY/ z
CONCRETFJMASONRYINSTAUlATU
N
GRATZ. PA 17030
-
�
185 PICTURE WINDOW
*• 0 'k
96" X 60" IMPACT
_�
�G��iT
FLANGE INSTALLATION DETAILSO•
AT OF
DRAtlfN:
01rGra.
1tLV �i��'�►5;;20R10�a�`��
1. 1NTERIORANDEXTERIORFINISHES.BYOTHERS
NOTSHOMFORCLARfr
V.L.
08--01613
2. PERIMETER AND JOINTSEALANTBYOTHERS TOBE
salNTS
DATE 06/04/12 5 OF 12
DESIGNED IN ACCORDANCE WITH ASTM E21 T2
L ROBERTO LOMASRE
Luis R. Lomas P.E.
1I92 WGOOFORORDLEWiSVU& NCr=
FL No.: 62514
4u4w4Svq rBm kba "palm"
c
1/2" MIN.
~� EDGE DISTANCE
WOOD FRAMING 1 1/4" MIN.
OR 2X BUCK EMBEDMENT
BY OTHERS
1/4" MAX.
BACKER ROD &
SHIM SPACE
APPROVED SEALANT
BEHIND FLANGElfl�
RIGID FILLER
#10 WOOD SCREW
INTERIOR
EXTERIOR
#10 WOOD SCREW
RIGID FILLER
BACKER ROD &
APPROVED SEALANT
1/4- MAX*
BEHIND FLANGE
SHIM SPACE
WOOD FRAMING
1 i/4' MIN.
OR 2X BUCK
EMBEDMENT
BY OTHERS
1/2" MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK INSTALLATION
1 1/4" MIN.
EMBEDMENT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
#10 WOOD
SCREW
1/2" MIN.
EDGE DIIISTANCI
J�
1/4" MAX.
SHIM SPACE
r RIGID FILLER
/ INTERIOR
EXTERIOR
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
WOOD FRAMING OA 2X BUCK INSTALLATION
METAL
STRUCTURE
BY OTHERS
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
1/4" MAX.
SHIM SPACE
31D FILLER
0 SMS OR
:LF DRILLING
:REW
REVISOCS
DESCRIPTION DALE APPROVED
REVISED INSTALLATION DETAILS 05/12/15 R.L.
REMOVED MONOLITHIC GLASS 08/12/16 R.L.
INTERIOR
EXTERIOR
#10 SMS OR
SELF DRILLING
NOTES.,
SCREW
1. INTERIOR AND EXTERIOR FLWHES. BY OTHERS
NOTSHOWNFORCLARRY
BACKER R00 &
RIGID FILLER
2.PERMe7ERANDJOINTSEALANTBYOTHERS77BE
APPROVED SEALANT
DESIGNEDIIVACCORDANCEWITHASTME2112
BEHIND FLANGE
1/4- MAX
SHIM SPACE
METAL
STRUCTURE
BY OTHERS
3/4" MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
METAL STRUCTUREINSTALLATTON
1 /4" MAX.
SHIM SPACE
RIGID FILLER
T INTERIOR
#10 SMS OR
SELF DRILLING
SCREWS
3/4" MIN.
EDGE DISTANCE
-jaw
META EXTERIOR
STRUCTURE BACKER ROD &
BY OTHERS APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
MI WINDOWS AND DOORS, LLC
650 W. MARKET ST.
GRATZ, PA 17030
185 PICTURE WINDOW
96" X 60" IMPACT
FLANGE INSTALLATION DETAILS WITH RIGID FILLER
DRAWN: 1q. RE
V.L. 708-01613 I
SCALE HTS I DAE 06/04/12 S'w 6 OF 12
L RaMERTOLOM IS IRZ
1432 WOOD FORD RD L EW I SV➢. L A NC 2AV 3
4346560M rlbrMtLAibmatpemm
SIGNED: 11/0=016
``R 11L p i
r,Eti
D T OF ;.lam,`
Luis R. Lomas P.E.
FL No.: 62514
REVISIM
REV DESCRIPTION
DATE APPROVED
A REVISED INSTALLATION DETAILS
05/112/15 R.L.
B REMOVED MONOLITHIC GLASS
08/12/16 R.L.
2 1/2" MIN.
EDGE DISTANCE
CONCRETE/MASONRY
"MIN
BY OTHERS
' e
•
EMBEDMENT
OPTIONAL IX BUCK
a •
• a
i 1/4MIN-
EMBEDMENT
CONCRETE/MASONRY
SEE NOTES 3 - 7
SEE
BY OTHERS
SHEET 1
a
• 1/4" MAX.
SHIM SPACE
BACKER R00
I/4' MAX.
OPTIONAL 1X BUCK •a �
& APPROVED
SHIM SPACE
SEE NOTES 3 - 7
SEALANT
SHEET t , RIGID FILLER
RIGID FILLER
•
3/16- TAPCON
o
3/16' TAPCON AVTERIOR
EXTERIOR
INTERIOR
3/16' TAPCON
'
BACKER ROD
2 1/2" .
& APPROVED
RIGID FILLER
MIN. v
EDGE •
SEALANT
DISTANCE EXTERIOR
OPTIONAL 1 X BUCK
SEE 3 7
1/4' MAX
SHIM SPACE
BACKER ROD
NOTE -
SHEET I
& APPROVED
SEALANT
CONCRETE/MASONRY
JAMB INSTALLATION DETAIL
BY OTHERS
a
a •!
1 1/4� IN.
CONCRETEWASONRYINSTALATION
e�•
4,
EMBEDMENT
a
a
SIGNED: 1110312016
2 1/2' MIN.
EDGE DISTANCE
MI WINDOWS ANDDOORS, LLC
R I I<<o
VERTICAL CROSS SECTION
CONCRETEANASONRYINSTALLATION
w. T ST.```s�
GRATZ, PA 17030
fz
rJ•*%OFM&*'9cp
185 PICTURE WINDOW
*� 0 *=
96" X 60" IMPACT
;-�AT
FLANGE INSTALLATION DETAILS WITH RIGID FILLERO:
AT OF
MV.Lt
f. INTERIOR AND EXTERIOR RNISHES. BY OTHERS.
NOTSHOWN FOR CLARITY.
08-01613
B
'pS
�NAi
22PERI RANDJOWrSEALANTBYOTHERSTOBE
SCAM NTS DATE 06/04/12 SEET7 OF 12
1�����
DESIGNEDINACCORDANCE WJTHASTME2112
L ROBEATULGMA.S P.E
Luis R. Lomas P.E.
I4.V N9ooTORD RD LEWISVRl6 NO 2707J
FL NO.: 52514
6
l"480- 6D9 rfgfiwq- rbmvp
1/2- MIN.
DISTANCE
WOOD FRAMING1
1/4" MIN.
METAL
OR 2X BUCKEMBEDMENT
BY OTHERSSTRUCTURE
BY OTHERS
*EDIE
4� MAX.BACKER
ROD &
SPACEBACKER
ROD &
APPROVED SEALANTAPPROVED
BEHINO FLlWGEOOD
SEALANT
SCREW
BEHIND FLANGE
INTERIOR
EXTERIOR
#10 WOOD SCREW
EXTERIOR
BACKER ROD &
APPROVED SEALANT
1/4• MAX.
BACKER ROD &
BEHIND FLANGE
SHIM SPACE
APPROVED SEALANT
BEHIND FLANGE
WOOD FRAMING
1 1d MIN.
OR 2X BUCK
METAL
BY OTHERS
EMBEDMENT
STRUCTURE
BY OTHERS
1/2' MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
WOOD FRAMING OR 2X BUCK IAPSTALLATION
1 1/4" MIN. 1/4" MAX.
EMBEDMENT SHIM SPACE
WOOD FRAMING
OR 2X BUCK
BY OTHERS INTERIOR
#10 WOOD
SCREW
1/2- MIN.
EDGE DISTANCE
EXTERIOR
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
3/4- MIN
EDGE DISTANCE
1/4` MAX.
SHIM SPACE
#10 SMS OR
SELF DRILLING
SCREW
INTERIOR
#10 SMS OR
SELF DRILLING
SCREW
1/4" MAX.
SHIM SPACE
3/4' MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
METAL STRUCTURE INSTALLATION
1/4' MAX.
FSHIM SPACE
#10 SMS OR
SELF DRILLING
1NTERKIR
SCCREWSREWS
3/4' MIN.
EDGE DISTANCE
IEXTERIOR
METAL BACKER ROD &
STRUCTURE APPROVED SEALANT
BY OTHERS BEHIND FLANGE
JAMS INSTALLATION DETAIL
METAL STRUCTURE INSTALLATION
REVISIONS
RN DESCRIPROR DATE APPROVED
A REVISED INSTALLATION DETAILS 05/12/15 R.L.
B REMOVED MONOLITHIC GLASS I OB/12/16 1 R.L
NOTES.,
T. INTERIOR AND EXTERIOR FINISHES. BYOTHERS
NOT SHOWNFOR CLARITY.
2. PERIMETERAND JOINT SEALANT BYOTHERS TO BE
DESIGNED INACCORDANCE MMASTM E2112
SIGNED. 1110312016
MI WINS ND BOORS, LLC
oWw. MARKS
GRATZ. PA 17030
.``��%`S�R:ICIo�'��.
�v yNGENg�'j ;p�
185 PICTURE WINDOW
96" X 60" IMPACT
FINLESS INSTALLATION DETAILS
pOTATPOF
���L►s'�CORIO;
DruwN
I1MGNo.
REv
08
B
8Tli111111%
Luis R. Lomas P.E.
FL No.: 62514
ucluE NTS I °`TE 06/04/12 �T83 OF 12
IA
LROBTOLOMASP.E
1482 VA31WFORP RD LEW;SVnA& NC 270y1
434886d609 r0omar[9ilm memm
CONCRETE/MASONRY
BY OTHERS
OPTIONAL 1 X BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
EXTERIOR
BACKER ROD
& APPROVED
SEALANT
OPTIONAL 1 X BUCK
SEE NOTE 3 - 7
SHEET 1
CONCRETE/MASONRY
BY OTHERS
2 1/2" MIN.
EDGE DISTANCE
I 1/4" MIN.
.� 4 .
• • 4 •4 •
• . 4
EMBEDMENT
1/4" MAX.
SHIM SPACE
3/16" TAPCON
INTERIOR
3/16" TAPCON
1/4" MAX.
IF
SHIM SPACE
• 4' .
• • ° ' 1 1/4" MIN.
e• .
• a EMBEDMENT
a
- J�
2 1/2" MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
CONCRETFJMILSONRY MSTALLA7TON
NOTES:
1. INTERIOR AND EXTERIOR FINISHES. BYOTHERS.
NOT SHOWN FOR CLARITY.
8 PERIMETER AND JOINT SEALANT BV OTHERS TO SE
DESIGNED W ACCORDANCE MM ASIM E2112
1 1/4" MIN.
EMBEDMENT
CONCRETE/MASONRY
BY OTHERS •a
OPTIONAL IX BUCK
SEE NOTES 3 - 7
SHEET 1
3/16' TAPCON
2 1/2" MIN. c
EDGE DISTANCE
REVISIONS
REV DESOUPTION WTE APPROVED
A REVISED INSTALLATION DETAILS 05/12/15 R.L.
8 REMOVED MONOLITHIC GLASS 08/12/16 R.L.
1/4" MAX.
F
SHIM SPACE
INTERIOR
• \ EXTERIOR
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
CONCRETE41ASONRY MSTALLATWN
MI WINDOWS AND DOORS, LLC
650 W. MARKET ST.
GRATZ. PA 17030
185 PICTURE WINDOW
96" X 60" IMPACT
FINLESS INSTALLATION DETAILS
DDD NO.
08-01613
NTS — 06/04/12 9 OF 12
L ROBERTO LOMAS PA
1432 WOODFORDRDLEVASv11LF, AC270M
434a8e-M +bnuspeLwm
SIGNED: 111032016
yP.1111L
vJ v\GEN3�s9J��i�
• TATE OR
Luis R. Lomas P.E.
FL No.: 62514
WOOD FRAMING
OR 2X BUCK
BY OTHERS
1/2" MIN.
EDGE DISTANCE
1 1/4" MIN. METAL
EMBEDMENT STRUCTURE
BY OTHERS
1/4' MAX.
BACKER ROD &
SHIM SPACE
BACKER
R ROD &
APPROVED SEALANT
BEHIND FLANGE
RIGID FILLER
pppBACKE
SEALANT
#10 WOOD SCREW
BEHIND FLANGE
INTERIOR
EXTERIOR
#10 WOOD SCREW
EXTERIOR
RIGID FILLER
BACKER ROD &
APPROVED SEALANT
1/4" MAX.
BACKER ROD &
BEHIND FLANGE
SHIM SPACE
APPROVED SEALANT
BEHIND FLANGE
W000 FRAMING
1 1/4" MIN.
OR 2X BUCK
EMBEDMENT
METAL
BY OTHERS
STRUCTURE
BY OTHERS
1/2' MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
WOOD FRAMINGOR 2X BUCK INSTALLATION
1 1/4' MIN.
EMBEDMENT
WOOD FRAMING
OR 2X BUCK
BY OTHERS
#10 WOOD
SCREW
1/4" MAX.
SHIM SPACE
RIGID FILLER
INTERIOR
1/2' MIN.
EDGE DISTANCE
J� EXTERIOR
BACKER ROD &
APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR2X'BUCK INSTALLATION
3/4" MIN
EDGE DISTANCE
i/4" MAX.
Li SHIM SPACE
RIGID FILLER
010 SMS OR
SELF DRILLING
SCREW
INTERIOR
#10 SMS OR
SELF DRILLING
SCREW
RIGID FILLER
1/4' MAX.
SHIM SPACE
3/4' MIN
EDGE DISTANCE
VERTICAL CROSS SECTION
METAL STRUCTIIREIN MI ATION
RLNSA)NS
REV OLSCRIPIDN DATE I APPROVED
A REVISED INSTALLATION DETAILS 05/12/15 R.L.
8 REMOVED MONOLITHIC GLASS GB/12/16 R.L.
NOTES:
1. INTERIORAND EXTERIOR FINISHES. BYOTHERA
NOT SHOWN FOR CLARITY.
2. PERIMETER ANOJODNT SEALANT BYOTHERS TO BE
DESIGNED WACCORDANCE MMASTME2112
1 /4' MAX.
SHIM SPACE
#10 SMS OR
RIGID FILLER
SELF DRILLING
SIR
SCREWS
SIGNED: 1110312016
�-
MI WINDOWS LLC
MnR
IR I�Lro#���,'
3/4" MIN.
. EDTOORS,
GRATZ. PA 17030
`\````S
- v '�GEIYB 9�+
EDGE DISTANCE
EXTERIOR
185 PICTURE WINDOW
96"X 60" IMPACT
_ W-TATPOFea.-
FINLESS INSTALLATION DETAILS WITARIGIDFILLER
METAL
BACKER ROD &
�_�
STRUCTURE
APPROVED SEALANT
DRAWN:
DWO NO.
�p'•Qtt+O `
HERS
eY °TJAMB
13EHIND FLANGE
08 13
FAl •P N
\
��I NA
lNSTALLATlON DETAIL
srwLE NTS °ATE O6/04/12 Ef
��METAL
STRUCTURE INSTALLATION
LROBERTOLOMASP.ELuis
14WKVCDFORDROLEWWVRJ FNAucseoso9
R. Lomos P.E.
&wm*QktmnpaFL
No.: 62514
CONCRETE/MASONRY
BY OTHERS
OPTIONAL IX BUCK
SEE NOTES 3 - 7
SHEET 1
BACKER ROD
& APPROVED
SEALANT
2 1 /2" MIN.
EDGE DISTANCE
'
4 • ••
°
1 1/4' MIN.
'
a
EMBEDMENT
J
1/4" MAX.
SHIM SPACE
RIGID FILLER
3/16" TAPCON
INTERIOR
3/I6" TAPCON _
RIGID FILLER
1/4" MAX.
SHIM SPACE
• a .
1 1/4" MIN.
• • ej
e
EMBEDMENT
e
EXTERIOR
BACKER ROD
do APPROVED
SEALANT
OPTIONAL IX BUCK
SEE NOTE 3 - 7
SHEET 1
CONCRETE/MASONRY
BY OTHERS
2 1/2" MIN
EDGE DISTANCE
VER77CAL CROSS SECTION
CONCRETEWASONRY INSTALLATTOV
NOTES
1. INTERIOR AND EXTERIOR RNSHEa 8Y0THERS
NOT SHOWNFORCLARRY.
2 PERLUETERANDJOINTSEALANTBYOTHERSTOBE
DESIGNED INAOCORDANCEW17HASTM E2/ 12
REVISIONS
GESORIPTION DATE APPROVED
REVISED INSTALLATION DETAILS 05/12/15 R.L.
REMOVED MONOLITHIC GLASS 08/12/16 1 R.L.
1 1/4' MIN.
EMBEDMENT
CONCRETE/MASONRY
BY OTHERS
a
• 1/4 MAX.
OPTIONAL 1X BUCK
_Q SHIM SPACE
SEE NOTES 3 - 7
SHEET 1
RIGID FILLER
3/16" TAPCON
a
INTERIOR
2 1/2" MIN.
a
EDGE DISTANCE
; EXTERIOR
BACKER ROD do
APPROVED SEALANT
BEHIND FLANGE
JAMB INSTALLATION DETAIL
CONCRETE/MASONRY INSTALLAT 1GN
SIGNED., 1110312016
MI WINDOWDOORS, LLC
MADK ET ST.
R11111116
L0 /z
GRATZ. PA 17030
�,J �GENs�'�'p��
0 *�
185 PICTURE WINDOW*•
96" X 60" IMPACT
FINLESS INSTALLATION DETAILS WITH RIGID FILLER
,o�=
�pO TAT OF • `
DRAWK
CWG NO.
13
08 611
8
S41NA111
s�uE
D"�
NTS O6/04/12 OF 12
111P%�```
Luis R. Lomas P.E.
FL No.: 62514
LROiSEMLOWSP.E
14MV4000FORDRDLEWISVGLENC270t7
�4W94 D9 181ms>0*1bus macro
APPROVED
SEALANT
BEHIND FIN
#6 WOOD
SCREW
3/8- MIN
EDGE DISTANCE
EXTERIOR INTERIOR
3/8- MIN
EDGE DISTANCE
#6 WOOD
SCREW
APPROVED
SEALANT
BEHIND FIN VERTICAL CROSS SECTION
WOOD FRAMING OR 2K BUCK INSTALLATION
NOTES,
1. INTERIOR AND EXTERIOR FINISHES, BYOTHERA
NOT SHOWN FORCLAR11Y.
2 PERWETERANDJOIIVTSEALANTBYOTHERSTOBE
DESIGNED INACCORDANCEWTM ASTM E2112
WOOD
FRAMING
BY OTHERS
_ 1 /4" MAX.
SHIM SPACE
1/4- MAX
SHIM SPACE
WOOD
FRAMING
BY OTHERS
REVISIONS
REV DESCROWN DALE APPROVED
A REVISED INSTALLATION DETAILS 05/12/15 R.L.
8 REMOVED MONOLITHIC GLASS 08/12/16 R.L.
I
WOOD FRAMING 1/4" MAX J
BY OTHERS SHIM SPACE
#6 WOOD
SCREW
1 1/4-
MIN. INTERIOR
EMBEDMENT v E
APPROVED
SEALANT
BEHIND FIN EXTERIOR
3/8- MIN
EDGE DISTANCE
JAMB INSTALLATION DETAIL
WOOD FRAMING OR 2X BUCK INSTALLATION
SIGNED: 111032016
MI WIND WS AND
1I�p z''
0 W. MARKET ST.
GRATZ. PA 17030`
``S�R
r-•*%GENs.'0wv-
W-.TeAV,
185 PICTURE WINDOW2
96" X IMPACTf,a�
L60"AT
FIN INSTALLATION DETAILSiO
I
ssaEE
DRAM
DRD NO.
os-01613
��l���lONA;``NTS
aE
06/04/12 12 OLROs1:RTOLOU"ReLuts
R. Lomos P.E.
No.: 62514
1482 w000FORD RDLEWSWUe R02T02FL
43"M-060 kb Mrpe�1