Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL. 34982 Phone:(772)462.2172 Fax:(772)462.6443 PROPERTY INFORMATION Address: 2680 Conifer Dr City / State / Zip: Ft Pierce, FI 34951 Parcel M 1334-506-0007-000/1 Zoning: sGANNED - BY & L �9e REVIEW COMMENTS Page 1 Owner(s): Gho Meadowood Corp Jurisdiction: SAINT LUCIE COUNTY Lot#: 50 APPLICATION INFORMATION Permit Number: 1802-0549 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: William N Handler Business Name: Gho Homes Corp Business Addr: 590 Nw Mercantile Place City / State / Zip: Port St Lucie, FI 34986 REVIEWS.AND COMMENTS Review Tvoe Status Reviewed By ADDRESSING ASSIGNMENT COMPLETE Lori Bender Comment: DOCUMENTS MISSING 3/1/2018 Comment: 3/7/2018 Comment: ENVIRONMENTAL REVIEW Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 4/5/2018 Comment: 4/5/2018 Comment: 4/5/2018 Block: Automatic Sprinkler System? No Fax Number: 561-688-0909 Date Started 3/2/2018 PENDING Lashahna Ingram 2/21/2018 PLEASE PROVIDE NOC VEG PERMIT FILED UNDER (G) FOR GHO. FEE POSTED. COMPLETE Lynn Swartzel 3/5/2018 COMPLETE Lashahna Ingram 2/21/2018 Email: Rebeccad@Ghohomes.Co m Date Completed 3/2/2018 3/7/2018 2/21/2018 Date Released 3/2/2018 3/7/2018 2/21/2018 PENDING William Durden 4/5/2018 COULD NOT COMPLETE MY REVIEW DUE TO THE CERTIFICATE FOR DESIGN LOAD COMPLIANCE IS COMPLETED TO THE 2014 BUILDING CODE. PLEASE REVIEW AND SUBMIT CORRECTED DOCUMENT DESIGNED TO THE 2107 FLORIDA RESIDENTIAL BUILDING CODE.SEE SECTION 107 OF THE 2017 FLORID BUILDING CODE. COULD NOT COMPLETE MY REVIEW DUE TO MULTIPLE PRODUCT APPROVALS ARE TO THE 2014 CO CYCLE. PLEASE SUBMIT THE PRODUCT APPROVAL IN DUPLICATE TO THE 2017 CODE CYCLE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. COULD NOT COMPLETE MY REVIEW DUE TO MULTIPLE PRODUCT APPROVALS LISTED ON THE PROD CT REVIEW AFFIDAVIT ARE OUTDATED. PLEASE SUBMIT THE PRODUCT REVIEW AFFIDAVIT IN DUPLICAT TO THE 2017 CODE CYCLE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Planning ✓li Development Services Building & Code Regulation Division, 2300 Virginia Avenue Fort -Pierce, FL, 34982 Phone:(772)462.2172 Fax:(772)462.6443 REVIEW COMMENTS Page 2 Comment: COULD NOT COMPLETE MY REVIEW DUE TO MULTIPLE PRODUCT APPROVALS LISTED ON THE PRODUCT 4/5/2018 REVIEW AFFIDAVIT ON THE PLANS ARE OUTDATED. PLEASE SUBMIT THE PRODUCT REVIEW AFFIDAVIT DUPLICATE TO THE 2017 CODE CYCLE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: COULD NOT COMPLETE MY REVIEW DUE TO NOTES ON THE PLANS REFER TO THE 2014 FLORIDA 4/5/2018 BUILDING CODE. PLEASE REMOVE ALL REFERENCES TO THE 2014 BUILDING CODE. SEE SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: PLAN PAGE MW-50 CALLS OUT R-19 INSULATION FOR THE KNEE WALL LOCATIONS. R-19 IS NOT SHOVO/ 4/5/2018 ON THE ENERGY CALC'S. SEE CHAPTER 4 SECTION 402 SUBSECTION 402.1.2 OF THE 2017 FLORIDA ENERGY CODE. Comment: • PLEASE ADD THE CUBIC VOLUME OF THE CONDITIONED SPACE TO INFORMATION BLOCK CONTAINING 4/5/2018 THE SQUARE FOOT INFORMATION OR A LETTER FROM THE DESIGN PROFESSIONAL SPECIFYING THE CUBIC VOLUME OF THE CONDITIONED SPACE. SEE CHAPTER 1 SECTION 107 OF THE 2017 FLORIDA BUILDING CODE. Comment: • PLEASE SHOW THE SOIL DENSITY ON THE PLANS OR SUBMIT A GEOTECHNICAL REPORT WITH 4/5/2018 RECOMMENDATIONS FOR THE NEW FILL REQUIREMENTS. SEE CHAPTER 4 SECTION R401 OF THE 201 FLORIDA RESIDENTIAL CODE. Comment: ACCORDING TO OUR CALCULATIONS THE ELEVATION OF THE HOME IS LOWER IN RELATION TO THE NEIGHBORING PROPERTY. IN WHICH CASE MAY CAUSE ISSUES WITH THE WATER RUNOFF AND 4/5/2018 FLOODING OF THE PROPERTY. THE HOME MUST BE CONSTRUCTED TO A HIGHER FFE OR SUBMIT AN ENGINEER STORM WATER PLAN SHOWING THE RETENTION/OR DIVERSION OF STORM WATER FOR THIS PROPERTY. PER SECTION 7.04.01 (D) OF THE LAND DEVELOPMENT CODE. Comment: PLANS SPECIFY TERMITE BAITING SYSTEM. A SIGNED CONTRACT ASSURING THE INSTALLATIOfV� / 4/5/2018 MAINTENANCE AND MONITORING OF THE BAITING SYSTEM THAT IS �/ IN COMPLIANCE WITH THE REQUIREMENTS OF CHAPTER 482, FLORIDA STATUTES. 4/5/2018 Comment: • THE ENERGY CALULATIONS MUST HAVE THE PREPARERS ORIGINAL SIGNATURE PLEASE FURNISH NEV/ ENERGY CALULATIONS WITH ORIGINAL SIGNATURE PER 107.1 OF THE 2017 FLORIDA BUILDING CODE ZONING REVIEW. COMPLETE Angela Huff Comment: 3/1/2018 3/1/2018 3/1/2018