Loading...
HomeMy WebLinkAboutELEVATIONS - SECTIONSPROJECT LOG ISSUED FOR START 10-10-17 ISSUED FOR PERMIT 11-13-17 BLDG, COMMENTS O4-24-18 x ATTIC VENT CALCULATION: (SQ IN) ROOF AREA CALCULATED 0 2774 (SQ.FT.) x 144 = 399,456 SQ IN. / 150 = 2,663 SQ. IN. REQUIRED NET VENT AREA / 15 SQ IN. PER LINEAR FT. (238 LF) VENT = 3,570 SQ. IN. TOTAL NOTE: CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF VENTS FLAT CONCRETE TILE 901 FELT SELF-ADHESIVE UNDERLAYMENT OVER 301 FELT TIN TAGGED TO EXT. GRADE PLYWD. SHEATHING (SEE DIAPHRAGM SCHEDULE FOR TYPE & NAILING PATTERN) PRE-ENG. WOOD ROOF TRUSSES 024" 0/C TYPICAL W/APPROVED GALV. TRUSS ANCHORS EA. END I$ SEE PLAN/ ELEV. GALV. MTL. DRIP ON iX2 P.T. 2x6 PAINTED TEXTURED SPRUCE FASCIA CEMENTITIOUS FINISH ON METAL LATH ATTACHED TO LEDGER & 2x4 BLOCKING W/ 3" CONTINUOUS VENTS ALL SIDES (TRUSS CO. TO PROVIDE FLAT SOFFIT) CEMEMNTITIOUS FINISH OVER 8" CONC. BLOCK R 4.2 BETWEEN STUDS 0'-0" FIN. FL. SLAB b .d 12 6 1 12 �6 t1'+ D.P.= +33.4 PSF O -36.3 PSF D.P.= t33.4 PSF �DOE] �`"• " , • O a .r t r0 36.3 PSF K `.• w.,.. ��%•, n•u wR <' PROVIDE �* CEMENTI D.P.= +31.9 PSF jj(yyyy=`�<�'"u SNM-.Y'�`K :Y PRIOR T I -34.7 PSF OJt�l } ----t------------------- ---- ----- ---- Y�L - -------------------------- cey:rr•..w.%�T,.^t'. r.. '- :�c Vie— N �2�yy'N.4r`ti?• -- --- --- INSULATION PER ENERGY CALC. TYPICAL INSTALLATION II WINDOW ASSEMBLY RAT RUNS PER TRUSS MANF. 5 8" DRYWALL OR 1/2" "TOUGHROCK" MARBLE SILL CAULK �R EQUAL) APPLIED TO of UNDERSIDE OF TRUSSES FIRE STOP .'MORTAR OR GROUT CONT. 8416" MASONRY BOND BEAM W/ 115 CONT. TOP & BOT. - FILL W/ CONC. 4 a d. ' CONT. METAL POUR STOP 4 DRYWALL 1/2" DRYWALL 1X2 P.T. FURRING 0 24" 0/C a EXTERIOR BLOCK WALL TO BE FURRING TO MASONRY WALL C a °.. WOOD BASE MONO. CONIC. FOOTING SEE FOUNDATION PLAN FOR NOTES & DETAILS "a e •°' III —I ' 4• III—III-111_ TYPICAL WALL SECTION SCALE 3/4" = i'0' vinyicorp.00m j8000 NW Ism Place I P 305 417.6464 Clarkwe5.ern Dietrich Sodding Systems LAC 1 Miami. Florida 33166+ F 305,477,4108 Soffit Vents (One Piece) Continuous one-piece Soffit Vent with reinforcing rib to key into stucco &amp, plaster. CS58-300V 1 5/8" 1 3' wide vent (one piece) 6" overall width, perforated Flanges 1 15 3" Soffit Vence - Continuous one-piece Soffit Vent with reinforcing rib to key Into stucco &amp', plaster. Vent Clips are provided to connect Soffit Vent and to assist in alignment. Vent area_ 15 square inches per lineal It. Caulk ail irtersectione butt joints, ends and comers at time of installation_ AS REQUIRED MANUFACTURER CAULK SEAM AT WINDOW INSTAL WCONTRACTOR TO APPLY TO ALL SIDES OF MASONRY OPENING INCLUDING HEADER AND JAMBS PER FBC 2017 703.4 ' SHER-CRETE FLEXIBLE CONCRETE WATER PROOF - SMOOTH A5-200 SERIES SHERWIN WILLIAMS MANUFACTURER APPLY PRODUCT DIRECTLY TO CLEAN CONCRETE SUBSTRATE PER MANUF. SPEC SET SILL IN FULL MORTAR BED AND HEAD JOINT STUCCO CR DECORATIVE �CEMENTITIOUS COATING 8' C.M.U. CAST-CRETE PRECAST SILL DETAIL SHERWIN WILLIAMS CONCRETE WATER PROOFING APPLICATION STUCCO ATTACHED TO METAL LATH ATTACHED TO UNDERSIDE OF TRUSSES RAT RUNS PER TRUSS MANT. (MAX. 8' O.C) D.P.= +29.9 PSF MEDIUM TEXTURE O -32.7 PSF LEFT ELEVATION - CLASSIC DECORATIVE CEMENTITOUS FINISH ON BLOCK WALLS, TYP. CONCEALED FASTENEK' j ; aC 1i�ENT5 ARE THE RESPONSISILn OF THE CONTRACTOR Or PFCORD 10 -8" T.O.B.B. 9'-4" T.O.B.B. MEDIUM TEXTURE TOUS FINISH 0 METER INSTALLATION 0'_0" FIN. FL. SLAB CONC. OR MASONRY ALUMINUM FRAME FASTEN TO BUCK W/ ix4 P.T. BUCK SET IN SEALANT AND NAILED STUCCO 3/16"x2 i12" TAPCON W/1-1/2" CASE HARDENE PERIMETERCAULKING 2x6 P.T. BUCK SET IN SEALANT FASTEN SCREWS 0 12" 0/C PERIMETER SEALANT COIL NAILS AT 12" 0/C. MAX' CONC. OR MASONRY ix4 P.T. BUCK SET IN W/ i14" DIAL 3-i14" SEALANT AND NAILED x TAPCONS 3" FROM E.E. STUCCO FINISH CONC. OR MASONRY W/1-1/2" CASE HARDENE f :.000 o. AND 6" 0/C MAX. (i—CONC. OR MASONRY COIL NAILS AT 12" 0/C. 0 0° . Qc' 1x4 P.T. BUCK SET IN b:: o'. 40*.; MAX. DOOR TRIM SEALANT AND NAILED W/1-1/2" CASE HARDENETSTUCCOFINISH DOOR FRAME M� NAILS AT 12" 0/C.CAULKING DRYWALL BOARD DRYWALL BOARD FASTEN TO BUCK W/ CAULKING I (2) #6 GALV. x 2" � DRYWALL BOARDFASTEN ALUMINUM FRAME SCREWS 0 2'-0" 0/C TO BUCK W/ DOOR FRAME DOOR TRIM CAULKING3116"x2-i12" TAPCON FASTEN TO BUCK W/ PERIMETER SEALANT SCREWS 0 12" O/C (2) J6 GALV. x 2" SCREWS 0 2'-0" 0/C STUCCO FINISH PERIMETER SEALANT HEAD/JAMB DETAIL (DOOR) JAMB DETAIL (WINDOW) HEAD DETAIL (WINDOW) JAMB/HEAD DETAIL (S.G.D.) CONC. COLUMN DOOR THRESHOLD SET WEATHER STRIPPING IN BED OF CAULK & FASTENED TO SILL W/ BY DOOR MANE GARAGE DOOR ALUMINUM FRAME SECURE FRAME TO SILL I8 x 1 i12" SCREWS 0 18" O/C PERIMETER CAULKING GALV. STL. VERT. TRACK BY MANE. FASTENED TO TRACK BRACKETS W/ WITH SILICONE CAULKING I DOOR FRAME FASTEN TO SILL W/ FLOOR COVERING i14"-20x112" CARRIAGE ., jl6 x 2" SCREWS BOLTS &LOCK NUTS OD ®2'-0" 0/C .o ' ' ° GALV. STL. TRACK : •q': .'poo°' a o0 BRACKETS FASTENED F FLOOR COVERING 0. CONC. FLOOR SLAB TO WOOD JAMB W/ 3116"xi-114" LAG SCREWS 2x8 P.T. ATTACHED TO PRECAST OR POURED SILL ." '° o.0 4P 0 Q00 0. O PERIMETER CAULKING MaNu.'s METHOD OF COLUMN W/ 5/8" WEDGE PERIMETER CAULKING STUCCO FINISH ATTACHMENT SHALL ANCHORS ® 2'-0" 0/C VERT. PREVAIL WHEN SUBMITTED 6" MAX. FROM ENDS) AND GROUT BED W COMPLETE INSTRUCTIONS 2° ROM INSIDE EDGEOF 21 CONCRETE SLAB SILL DETAIL (DOOR) JAMB DETAIL (GARAGE DOOR) SILL DETAIL (WINDOW) SILL DETAIL (S.G.D.) R-30 INSULATION AT AIR CONDITIONED CEILING LOCATIONS PRE ENGINEERED WD. TRUSSES @ 24" O/C TYPICAL COV. PORCH FOYER GREAT ROOM SLOPE 1 STUCCO ATTACHED TO METAL LATH ATTACHED TO UNDERSIDE OF TRUSSES RAT RUNS PER TRUSS MAN'F. 12 (MAX. 8' O.C) , HESE p 6 "'HF SUBLANSjpC_ g1Vp ALL M11A�BE Ep 6Y Fro AAI YCpRoJoi j Q�MMDyIV,r Coro S 4LLpAp � ,q �Rs p;,Ar K B, 10'-B" T.O.B.B. 9'-4" T.O.B.B. COVERD PATIO SLOPE — — - — - 0'-0' FIN_ FL. SLAB SECTION A -A - CLASSIC W UJ OW so LicJ so es '* J a do Z WUJ n oo a ui -71 o J 1 J Y W W Z do U m z do D z J sa z o a j oD o a � o C C C Sm 2 C- a a c a OL c N O O fl O U a cu Cgii c� E S -co) rp = as o : c o CL O S E o o a U 4d E •= 4--r tL to °J > a1i c o v 1--E � 01 a _ N vi O at o O O UJ H a3 73 E 4eiv _ O Z 0-ra V -O -0ai � W J 1..L lei i 0 z OU w 3 W C ,) �/ � U J OJ W Lr ELEVATIONS SECTIONS A-4 MW - 50