HomeMy WebLinkAboutELEVATIONS - SECTIONSPROJECT LOG
ISSUED FOR START 10-10-17
ISSUED FOR PERMIT 11-13-17
BLDG, COMMENTS O4-24-18
x
ATTIC VENT CALCULATION: (SQ IN)
ROOF AREA CALCULATED 0 2774 (SQ.FT.) x 144 = 399,456 SQ IN.
/ 150 = 2,663 SQ. IN. REQUIRED NET VENT AREA
/ 15 SQ IN. PER LINEAR FT. (238 LF) VENT = 3,570 SQ. IN. TOTAL
NOTE: CONTRACTOR SHALL FIELD VERIFY LOCATIONS OF VENTS
FLAT CONCRETE TILE
901 FELT SELF-ADHESIVE UNDERLAYMENT
OVER 301 FELT TIN TAGGED
TO EXT. GRADE PLYWD. SHEATHING
(SEE DIAPHRAGM SCHEDULE FOR TYPE
& NAILING PATTERN)
PRE-ENG. WOOD ROOF TRUSSES
024" 0/C TYPICAL
W/APPROVED GALV. TRUSS
ANCHORS EA. END
I$ SEE PLAN/ ELEV.
GALV. MTL. DRIP
ON iX2 P.T.
2x6 PAINTED TEXTURED
SPRUCE FASCIA
CEMENTITIOUS FINISH ON METAL LATH ATTACHED
TO LEDGER & 2x4 BLOCKING
W/ 3" CONTINUOUS VENTS ALL SIDES
(TRUSS CO. TO PROVIDE FLAT SOFFIT)
CEMEMNTITIOUS FINISH
OVER 8" CONC. BLOCK
R 4.2 BETWEEN STUDS
0'-0" FIN. FL. SLAB
b
.d
12
6 1
12
�6
t1'+
D.P.= +33.4 PSF
O -36.3 PSF
D.P.= t33.4 PSF
�DOE]
�`"• " , •
O
a
.r
t
r0
36.3 PSF
K
`.•
w.,.. ��%•, n•u
wR
<'
PROVIDE
�* CEMENTI
D.P.= +31.9 PSF
jj(yyyy=`�<�'"u
SNM-.Y'�`K
:Y PRIOR T
I
-34.7 PSF
OJt�l
}
----t-------------------
---- ----- ----
Y�L -
--------------------------
cey:rr•..w.%�T,.^t'.
r.. '- :�c Vie—
N �2�yy'N.4r`ti?•
-- ---
---
INSULATION
PER ENERGY CALC.
TYPICAL INSTALLATION
II WINDOW ASSEMBLY
RAT RUNS PER
TRUSS MANF.
5 8" DRYWALL OR 1/2" "TOUGHROCK" MARBLE SILL CAULK
�R EQUAL) APPLIED TO
of UNDERSIDE OF TRUSSES
FIRE STOP
.'MORTAR OR
GROUT
CONT. 8416" MASONRY BOND BEAM
W/ 115 CONT. TOP & BOT. - FILL W/ CONC. 4
a d. '
CONT. METAL POUR STOP 4
DRYWALL
1/2" DRYWALL
1X2 P.T. FURRING 0 24" 0/C a
EXTERIOR BLOCK WALL TO BE
FURRING TO
MASONRY WALL
C a °..
WOOD BASE
MONO. CONIC. FOOTING
SEE FOUNDATION PLAN
FOR NOTES & DETAILS
"a
e
•°'
III —I
'
4•
III—III-111_
TYPICAL WALL SECTION
SCALE 3/4" = i'0'
vinyicorp.00m j8000 NW Ism Place I P 305 417.6464
Clarkwe5.ern Dietrich Sodding Systems LAC 1 Miami. Florida 33166+ F 305,477,4108
Soffit Vents (One Piece)
Continuous one-piece Soffit Vent with reinforcing rib to key into stucco &, plaster.
CS58-300V 1 5/8" 1 3' wide vent (one piece) 6" overall width, perforated Flanges 1 15
3" Soffit Vence - Continuous one-piece Soffit Vent with reinforcing rib to key Into stucco &', plaster. Vent Clips are provided to connect Soffit Vent and
to assist in alignment.
Vent area_ 15 square inches per lineal It.
Caulk ail irtersectione butt joints, ends and comers at time of installation_
AS REQUIRED
MANUFACTURER
CAULK SEAM AT
WINDOW INSTAL
WCONTRACTOR TO APPLY TO ALL SIDES
OF MASONRY OPENING INCLUDING HEADER
AND JAMBS PER FBC 2017 703.4
' SHER-CRETE
FLEXIBLE CONCRETE
WATER PROOF - SMOOTH
A5-200 SERIES
SHERWIN WILLIAMS MANUFACTURER
APPLY PRODUCT DIRECTLY TO CLEAN
CONCRETE SUBSTRATE PER MANUF. SPEC
SET SILL IN FULL
MORTAR BED AND HEAD JOINT
STUCCO CR
DECORATIVE
�CEMENTITIOUS
COATING
8' C.M.U.
CAST-CRETE PRECAST SILL DETAIL
SHERWIN WILLIAMS CONCRETE WATER PROOFING APPLICATION
STUCCO ATTACHED TO METAL LATH
ATTACHED TO UNDERSIDE OF TRUSSES
RAT RUNS PER TRUSS MANT.
(MAX. 8' O.C)
D.P.= +29.9 PSF
MEDIUM TEXTURE O -32.7 PSF LEFT ELEVATION - CLASSIC
DECORATIVE CEMENTITOUS FINISH
ON BLOCK WALLS, TYP.
CONCEALED FASTENEK' j ; aC 1i�ENT5
ARE THE RESPONSISILn OF THE
CONTRACTOR Or PFCORD
10 -8" T.O.B.B.
9'-4" T.O.B.B.
MEDIUM TEXTURE
TOUS FINISH
0 METER INSTALLATION
0'_0" FIN. FL. SLAB
CONC. OR MASONRY
ALUMINUM FRAME
FASTEN TO BUCK W/
ix4 P.T. BUCK SET IN
SEALANT AND NAILED
STUCCO
3/16"x2 i12" TAPCON
W/1-1/2" CASE HARDENE
PERIMETERCAULKING
2x6 P.T. BUCK SET IN
SEALANT FASTEN
SCREWS 0 12" 0/C
PERIMETER SEALANT
COIL NAILS AT 12" 0/C.
MAX'
CONC. OR MASONRY
ix4 P.T. BUCK SET IN
W/ i14" DIAL 3-i14"
SEALANT AND NAILED
x
TAPCONS 3" FROM E.E.
STUCCO FINISH
CONC. OR MASONRY
W/1-1/2" CASE HARDENE
f :.000 o. AND 6" 0/C MAX.
(i—CONC. OR MASONRY
COIL NAILS AT 12" 0/C.
0 0° . Qc'
1x4 P.T. BUCK SET IN
b:: o'. 40*.;
MAX.
DOOR TRIM
SEALANT AND NAILED
W/1-1/2" CASE HARDENETSTUCCOFINISH
DOOR FRAME
M� NAILS AT 12" 0/C.CAULKING
DRYWALL BOARD
DRYWALL BOARD
FASTEN TO BUCK W/
CAULKING
I
(2) #6 GALV. x 2"
� DRYWALL BOARDFASTEN
ALUMINUM FRAME
SCREWS 0 2'-0" 0/C
TO BUCK W/
DOOR FRAME
DOOR TRIM
CAULKING3116"x2-i12"
TAPCON
FASTEN TO BUCK W/
PERIMETER SEALANT
SCREWS 0 12" O/C
(2) J6 GALV. x 2"
SCREWS 0 2'-0" 0/C
STUCCO FINISH
PERIMETER SEALANT
HEAD/JAMB DETAIL (DOOR)
JAMB DETAIL (WINDOW)
HEAD DETAIL (WINDOW)
JAMB/HEAD DETAIL (S.G.D.)
CONC. COLUMN
DOOR THRESHOLD SET
WEATHER STRIPPING
IN BED OF CAULK &
FASTENED TO SILL W/
BY DOOR MANE
GARAGE DOOR
ALUMINUM FRAME
SECURE FRAME TO SILL
I8 x 1 i12" SCREWS
0 18" O/C
PERIMETER CAULKING
GALV. STL. VERT. TRACK
BY MANE. FASTENED TO
TRACK BRACKETS W/
WITH SILICONE
CAULKING
I DOOR FRAME
FASTEN TO SILL W/
FLOOR COVERING
i14"-20x112" CARRIAGE
.,
jl6 x 2" SCREWS
BOLTS &LOCK NUTS
OD
®2'-0" 0/C
.o ' ' °
GALV. STL. TRACK
: •q': .'poo°'
a o0
BRACKETS FASTENED
F FLOOR COVERING
0.
CONC. FLOOR SLAB
TO WOOD JAMB W/
3116"xi-114" LAG SCREWS
2x8 P.T. ATTACHED TO
PRECAST OR POURED
SILL
." '° o.0 4P 0
Q00 0. O
PERIMETER CAULKING
MaNu.'s METHOD OF COLUMN W/ 5/8" WEDGE
PERIMETER CAULKING
STUCCO FINISH
ATTACHMENT SHALL ANCHORS ® 2'-0" 0/C VERT.
PREVAIL WHEN SUBMITTED 6" MAX. FROM ENDS) AND
GROUT BED
W COMPLETE INSTRUCTIONS 2° ROM INSIDE EDGEOF 21
CONCRETE SLAB
SILL DETAIL (DOOR)
JAMB DETAIL (GARAGE DOOR)
SILL DETAIL (WINDOW)
SILL DETAIL (S.G.D.)
R-30 INSULATION AT AIR CONDITIONED
CEILING LOCATIONS
PRE ENGINEERED WD. TRUSSES
@ 24" O/C TYPICAL
COV.
PORCH FOYER GREAT ROOM
SLOPE
1
STUCCO ATTACHED TO METAL LATH
ATTACHED TO UNDERSIDE OF TRUSSES
RAT RUNS PER TRUSS MAN'F.
12 (MAX. 8' O.C)
, HESE p
6 "'HF SUBLANSjpC_ g1Vp
ALL M11A�BE Ep 6Y Fro AAI YCpRoJoi j
Q�MMDyIV,r Coro S
4LLpAp � ,q �Rs p;,Ar K
B,
10'-B" T.O.B.B.
9'-4" T.O.B.B.
COVERD
PATIO
SLOPE
— — - — - 0'-0' FIN_ FL. SLAB
SECTION A -A - CLASSIC
W
UJ
OW
so
LicJ
so es
'* J
a
do
Z
WUJ
n oo
a
ui -71
o
J
1
J
Y
W
W Z
do
U m
z
do
D
z
J
sa
z
o
a
j
oD
o
a
�
o
C
C
C
Sm
2
C-
a
a
c
a
OL
c
N
O
O
fl
O
U
a
cu
Cgii
c�
E
S
-co)
rp
=
as
o
:
c
o
CL
O
S
E
o
o
a
U
4d
E
•=
4--r
tL
to
°J
>
a1i
c
o
v
1--E
�
01
a
_
N
vi
O
at
o
O
O
UJ H
a3
73
E
4eiv
_
O
Z
0-ra
V
-O
-0ai
�
W
J
1..L
lei
i
0
z
OU
w
3
W
C ,)
�/
�
U
J
OJ
W
Lr
ELEVATIONS
SECTIONS
A-4
MW - 50