Loading...
HomeMy WebLinkAboutTRUSS PLANa: EDGE STRIP DEFINED AS THE LESSER OF 10% OF LEAST HORIZONTAL DIMENSION OF BUILDING LEAST OF HORIZONTALHEIGHT DIMENSION OF BUILDINNG AS THAN ND OF AT LEAST 3 FT. NOTE: SEE DIAPHRAGM SCHEDULE FOR ROOF ZONE NAILING REQUIREMENTS. L-------------- I O I 1 I I r-M O 1----J' 1 ROOF ZONE DIAGRAM A w N NOTE: THIS TYPICAL DETAIL TO BE USED WHERE CONDITIONS MAY OCCUR BASED ON TRUSS DESIGN AND FIELD CONDITIONS �71� TYP. RIDGE CAP & ROOF MEMBRANE 2x RIDGE BOARD (2) SIMPSON H10 CLIPS ON 1 SIDE OF TRUSS STAGG. & ATTACHED TO 2x6 CATS ® 24" O/C BETWEEN TRUSS RUN PRE ENGINEERED ROOF TRUSSES SEE FRAMING PLAN FIELD FRAMED RIDGE DETAIL TRUSS CONNECTOR SCHEDULE FASTENERS PER STRAP ALLOWABLE UPLIFT PARALLEL LOAD (F2) PERPEND. LOAD (FI) MARK USP CONNECTOR TRUSS TIE -BEAM OR WALL SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP SINGLE STRAP DOUBLE STRAP TC-i TA12 (5) 10d x 1-1/2' - 990 1980 335 670 245 490 TC-2 TA14 (7) 10d x 1-1/2' - 1205 2410 335 670 245 490 TC-3 HIWM16 8 fOd x 1-1 2' 4 1 4" x 1-3/4' WAB. 1225 - 1225 - 1225 - TC-4 HTA16 9 10d x 1-1 2' - 1870 2430 710 1310 270 1215 TC-5 HTW20 20 10d x 1-1 2 24 10d x 1-1/2' 1530 - - - - - 1) ALLOWABLE LOADS ARE BASED ON USP CATALOG 2015-16. 2) BLDR MAY USE LONGER STRAPS OF SAME TYPE SPECIFIED. 3) USE GALVANIZED NAILS OR WOOD SCREWS AS SPECIFIED BY MANUFACTURER. 4) TAPCONS SHOULD BE LOCATED AT THE FARTHEST POINT FROM THE TOP OF THE BEAM, DIAPHRAGM SCHEDULE (FASTENING REQUIREMENTS PER R803.2.3.1) DIAPHRAGM NAILING DIAPHRAGM ZONE 1 ZONE 2 ZONE 3 PANEL FRAMING BOUNDARIES EDGE INTER. EDGE INTER. EDGE INTER. LOCATION PANEL GRADE THICKNESS SPACING REMARKS ROOF APA RATED SHEATHING 8d RING- Bd RING- 8d RING- Bd RING- 8d RING- 8d RING- 8d RING - EXPOSURE I, OR EQUAL SPAN RATING 40120 19 32' 24" 0/C MAX. SHANK 6" 0 C SHANK 6' 0 C SHANK 6" 0 C SHANK 6' 0 C SHANK 6" O C SHANK 4' 0/C SHANK 4" 0 C BLOCKED AS SHOWN ON PLAN EXT. WALL APA RATED SHEATHING EXPOSURE 1, OR EQUAL SPAN RATING 40120 19132 16" 0/C MAX. 8d RING- SHANK 4" 0 C 8d RING- SHANK 4' 0 C 8d RING- SHANK 6" 0 C NAIL CORNER STUDS AT 4" 0/C MAX. TYPICAL BLOCK FREE EDGES INT WALL APA RATED SHEATHING EXPOSURE I, OR EQUAL SPAN RATING 32116 15132 16" 0/C MAX. 8d RING- SHANK 6' 0 C 8d RING- SHANK 6" O C 8d RING- SHANK 12" O C BLOCK FREE EDGES ROOF NAILING IS IDENTICAL FOR ZONES 1 & 2 Ip I � A1y ,yJ RING -SHANK NAILS TO HAVE THE FOLLOWING DIMENSIONS: 1. 0.113 INCH NOMINAL SHANK DIAMETER 2. RING DIAMETER OF 0.012 OVER SHANK DIAMETER J. 16 TO 20 RINGS PER INCH 4. 0.280 INCH FULL ROUND HEAD DIAMETER 5. 2 INCH NAIL LENGTH CONCCulfofA37FN AS ACORoA'A!FVS�IllTv. 9'1476 D.I w Liw w J J J a_ O d LL d O = m X ME 727# MAX. UPLIFT E.E. 722# MAX. UPLIFT E.E. X 473# MAX. UPLIFT E.E. 'o TC-1 TC-1 TC-1 i i i N �'~ N U M N U ~ 9' -4" PLATE HT. 10' -8" PLATE HT. HARDWARE =HUS26 HANGERS (QTY. 2) Indicates Left End Of Truss On Layout & Engineering Sheets OWA END OVERHANG PROJECT LOG I I ISSUED FOR START 110-10-171 ISSUED FOR PERMIT 11-13-17 w o_ o w L J J W a�Q Z R m m m d W Z O � LL w U m m z Z ! M J F LL a J oC6 Z O Z 0 a w 0 0 L a C R w O O � a 1 G 0 '� a L 'O of -0 6 O O 2 ro -O Qi N V O O O .� } i LD O @ J � - E 0 0. G 'O U Vl 0 E E O O E o o O-u 0 O v E .aj p - C7 O~ u fa tr-- 'o v -O Z d. , _O a to .— Via Tyry L v W I. e 8 0 o m o V u O f A i Lu l®rl t r O J 0 CV % h. g `.V,R■ I� LL � z O w 0 L1J Ah��F/�I Ln 0 ( J Lfl < J 1 Lcu Ln O G 1/4" = V-O" U.N.O. TRUSS PLAN Mel fik mw = 5 o