HomeMy WebLinkAboutSOIL NUCLEAR TESTRECEIVED
MAY 0 9 L`018
ST. Lucie County, Permitting
''''Farut+e"•
Port St Lucie
FSPE CA 0 4930
607 My commodcy cove Port SL Woo. FL 34986
Phone: 772-924.3575 1 Fax: 772-924.3580
Soil Nuclear Gauge
Report Date: 5/912018
Test Method: ASTM D 6938
SCANNED
By
St Lucie C®u*
Client Project
Rizon Corporation 18-5951.00
895 Woodlands Dr 11953 South Indian River Drive
Port Saint Lucie, FL 34953 Jensen Beach, FL
Test Results
Test #
Retest
Of
Test
Date
Proctor ID
Method
Soft
Classification
Optimum
Moisture
(96)
Maximum
DryDensity
(pcf)
In Place
Moisture
I)
In Place
Dry Density
(pcf)
Probe
Depth
(in)
Percent
Compaction
MinlMax
Comp.
I%)
Remark
1
514/18
P-1
N/A
9.0
112.1
8.8
107.3
12
96
95 / 105
Pass
2
514/18
P-1
N/A
9.0
112.1
8.4
106.9
12
95
95/ 105
Pass
3
514118
P-1
N/A
9.0
112.1
9.0
107.7
12
96
95/105
Pass
Test Information
Test #
Test Location
Elevation
Reference
Gauge
Make / Model / SN / Calibrated
Field Technician
1
Below Stab Grade: Garage pad, Southeast section
0-1
Troxier 13430 / 24566 /
Baker, Jeff
2
Below Slab Grade: Garage pad, Center section
0-1
Troxier / 3430/24566 /
Baker, Jeff
3
Below Slab Grade: Garage pad. Northwest section
0.1
Troxier 13430 / 24566 /
Baker, Jeff
Remarks
Comments'
Pass: Tests results comply with specifications
Tests are'Direct Transmission' (Method A) unless probe depth is noted as
'Beckscaaer'. Gauge calibration data on file with the testing agency.
\�Illlllll////y
NN KENT
� GENSF''•.
0 6,32/18
E OF
Pirof�HA ifIeEC 18
States
Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. Page 1 of 1
Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies.