HomeMy WebLinkAboutREVISION• 9KANNED
StL, udeLount�RE:CEIVED
MIAMI DARE 7 0 �;��� MIAMI-DADE COUNTY
RODUCT CONTROL SECTION
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCESt 11805 SW 26 Street, Room208
BOARD AND CODE ADMINISTRATION DIVISION �� Permitting Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.Eov/economy
Boral Roofing, LLC
7575 Irvine Center Drive, Suite 100
Irvine, CA 92618
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Spanish `S' Nuevo Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of an endor ment of any produ
for sales, advertising or any other purposes shall automatically terminat e
I
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami-]
date may be displayed id advertising literature. If any portion of the NOA is
by
INSPECTION: A copy of this entire NOA shall be provided to the usa b �'` 'n�'a `at��tNr' sibto and
shall be available for inspection at the job site at the request of the Building Official. tt��
This NOA renews NOA No. 12-0308.19 and consists of pages I through 7.
The submitted documentation was reviewed by Juan E. Col'lao, R.A. F11e C®�
NOA No.: 14-0408.06
QMIAMMI-DMEUNTY Expiration Date: 05/20/19
Approval Date: 06/05/14
Page 1 of 7
I
ROOFING ASSEMBLY APPROVAL
Category:
Roofing
Sub -Category:
Roofing Tiles
Material:
Concrete
Deck Type:
Wood
1. SCOPE
This approves a system using Spanish 'S' Nuevo Concrete Roof Tile, as manufactured by Boral Roofing LLC in
Lake Wales, FL., and described this Notice of Acceptance. For locations where the pressure requirements, as
determined by applicable Building Code does not exceed the design pressure values obtained by calculations in
compliance with RAS 127 using the values listed in the installation section herein. The attachment calculations shall
be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test
Product
Applicant
Dimensions
Specifications
Description
Spanish 'S' Nuevo Tile
L = 17"
TAS 112
High profile, interlocking, one-piece, 'S'
W = 9 3/4"
shaped, high-pressure extruded concrete
H = 2 27/32"
roof tile equipped with three nail holes. For
Min. 0.65" thick
direct deck nail -on, mortar set or adhesive
set applications.
Trim Pieces
L= varies
TAS 112
Accessory trim, concrete roof pieces for use
W = varies
at hips, rakes, ridges and valley
Varying thickness
terminations. Manufactured for each tile
profile.
2.1 MANUFACTURING LOCATION
1. Lake Wales, FL
2.2 SUBMITTED EVIDENCE:
Test Agency
Test Identifier
Test Name/Report
Date
Redland Technologies
7161-03
Static Uplift Testing
Dec. 1991
Appendix III
PA 102 & PA 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing
Dec. 1991
Appendix II
PA 108 (Nail -On)
Redland Technologies
P0647-01
Wind Tunnel Testing
Aug. 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of
Sept. 1993
screw vs. smooth shank nails
The Center for Applied
94-084
Static Uplift Testing
May 1994
Engineering, Inc.
PA 101 (Mortar Set)
The Center for Applied
94-083
Static Uplift Testing
April 1994
Engineering, Inc.
PA 101 (Adhesive Set)
NOA
No.: 14-0408.06
M[AMI-DADE COUNTYM
Expiration Date: 05/20/19
Approval
Date: 06/05/14
Page 2 of 7
2.2 SUBMITTED EVIDENCE:
Test Mency
Test Identifier
Test Name/Report,
Date
The Center for Applied
25-7183-4
Static Uplift Testing
Feb. 1995
Engineering, Inc.
PA 102 (2 Quik-Drive Screws,
Direct Deck)
The Center for Applied
25-7214-3
Static Uplift Testing
March, 1995
Engineering, Inc.
PA 102 (1 Quik-Drive Screw,
Direct Deck)
Redland Technologies
Letter Dated Aug. 1, 1994
Wind Tunnel Testing
Aug. 1994
PA 108 (Nail -On)
The Center for Applied
Project No. 307025
Wind Driven Rain
Oct. 1994
Engineering, Inc.
Test #MDC-78
PA 100
Nutting Engineering
13343.1
Physical Properties
Feb 2009
TAS 112
Celotex Corporation Testing
520111-3
Static Uplift Testing
Dec. 1998
Service
520191-2-1
PA 101
March 1999
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
Jan 2009
Walker Engineering, Inc.
Evaluation Calculations
25-7094
February 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7496
April 1996
Walker Engineering, Inc.
Evaluation Calculations
25-7584
December 1996
25-7804b-8
25-7804-4 & 5
25-7848-6
Walker Engineering, Inc.
Evaluation Calculations
25-7183
March 1995
Walker Engineering, Inc.
Calculations
Two Patty Adhesive Set System .
April 1999
Walker Engineering, Inc.
Evaluation Calculations
Restoring Moment Due to Gravity
Jan 2009
Walker Engineering, Inc.
Calculations
Aerodynamic Multiplier
09/01/10
Restoring Moment Due to Gravity
09/02/10
American Test Lab of South
RT0130.01-14
TAS 112
02/05/14
Florida
RT0426.01-14
TAS 112
05/02/14
NOA No.: 14-0408.06
Expiration Date: 05/20/19
Approval Date: 06/05/14
Page 3 of 7
3. LIMITATIONS
3.1 Fire classification is not part of this acceptance.
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Building Code
Compliance Office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 May be installed on slopes 7:12 and greater
3.8 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
4. INSTALLATION
4.1 Spanish `S' Nuevo Concrete Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 118, RAS 119, and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (lbf)
Length4 (ft)
Width-w (ft)
Spanish 'S' Nuevo Tile
8.95
1.417
0.8125
Table 2: Aerodynamic Multipliers - ,% (ft)
Tile
Profile
X (ft)
Batten Application
(ft)
Direct Deck Application
Spanish 'S' Nuevo Tile
0.215
0.233
Table 3: Restoring Moments due to Gravity - M9 (ft-lbf)
Tile
Profile
2:12
3:12
4:12
5:12
6:12
7:12 or greater
Spanish
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
'S' Nuevo
Deck
Deck
Deck
Deck
Deck
Deck
Tile
5.36
6.00
5.30
5.93
5.21
5.83
5.09
5.70
4.96
5.56
1 4.82
5.39
NOA No.: 14-0408.06
MIAMI•DADECOUNTY Expiration Date: 05/20/19
Approval Date: 06/05/14
Page 4 of 7
Table 4: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
For Nail -On Systems
Tile
Profile
Fastener Type
Direct Deck
(min 15132"
plywood)
Direct Deck
(min. 19/32"
plywood)
Battens
Spanish 'S'
2-10d Ring Shank Nails
28.6
41.2
19.4
Nuevo Tile
1-10d Smooth or Screw Shank Nail
5.1
6.8
2.8
2-10d Smooth or Screw Shank Nails
6.9
9.2
7.3
1 - #8 Screw
20.7
20.7
18.1
2 - #8 Screws
43.2
43.2
29.8
1-10d Smooth or Screw Shank Nail
Field Clip)
23.1
23.1
19.0
1-10d Smooth or Screw Shank Nail
Eave Clip)
29.3
29.3
24.0
2-10d Smooth or Screw Shank Nails
Field Clip)
27.6
27.6
38.6
2-10d Smooth or Screw Shank Nails
Eave Clip)
38.1
38.1
41.8
2-10d Ring Shank Nails 33.1 48.1 45.2
1 Installation with a 4" the headlap and fasteners are located a min. of 2'/2" from head of tile.
Table 5: Attachment Resistance Expressed as a Moment Mf (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Spanish 'S' Nuevo Tile
Adhesive2
29.3
2 See manufactures component approval for installation requirements.
3 Flexible Products Company TileBond Average weight per patty 10.7 grams.
3MTm 2-Component Foam Roof Tile Adhesive AH-160 Average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mf (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Spanish 'S' Nuevo Tile
3MTm 2-Component Foam Roof Tile Adhesive AH-160
66.5
3MTM 2-Component Foam Roof Tile Adhesive AH-160
38.7
4 Large paddy placement of
63 grams of 3MTm2-Component Foam Roof Tile Adhesive AH-160.
5 Medium paddy placement of 24 grams of 31VIT°° 2-Component Foam Roof Tile Adhesive AH-160.
MIAMI•DADE COUNTY
�Wjdd 01,141,
NOA No.: 14-0408.06
Expiration Date: 05/20/19
Approval Date: 06/05/14
Page 5 of 7
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar Set Systems
Tile
Profile
Tile
Application
Attachment
Resistance
Spanish 'S' Nuevo Tile
Mortar Set
24.5
6 Tile-Tite Roof Tile Mortar.
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo (See Detail Below), or
following statement: "Miami -Dade County Product Control Approved".
BORAL ROOFING LLC SPANISH `S' NUEVO CONCRETE ROOF TILE (LAKE WALES, FL.)
(LOCATED ON UNDERSIDE OF TILE)
6. BUILDING PERMIT REQUIREMENTS
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by the Building Official or applicable building code in order to
properly evaluate the installation of this system.
MMNOA No.: 14-0408.06
MIAMI•DADECOUNTY Expiration Date: 05/20/19
Approval Date: 06/05/14
Page 6 of 7
Fastener Hole
PROFILE DRAWINGS
y�
SPANISH `S' NUEVO CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 14-0408.06
Expiration Date: 05/20/19
Approval Date: 06/05/14
Page 7 of 7