HomeMy WebLinkAboutELEVATION PLANNAILING SCHEDULE ITEM NAIL SIZE EDGE SPACING FIELD SPACING NOTES 5/8" CDX ROOF SHEATHING 8 d 6" O.C. b" O.C. 3" OG, EDGE 4 3" OZ. FIELD WITHIN 4' OF ROOF EDGE 5/8" CDX ROOF SHEATHING 8 d 4" O.C, b" D.C. 8' - O" FROM GABLE END ROOF EDGE 1/2" CDX WALL SHEATHING 8 d 6" O.C. b" OjC, 3/4" T 4 G FLOOR SHEATHING 10 d 6" O C. 6"O.C. GLUE ALL PLYWOOD PL400 OR EQUAL STUD TO 1 X 12 HEADER Iro d 3 PER HEADER PLY BASE SWEET NAILING roll O/C w 4 II" 14ARDI PLANK LAP SIDING 8d j GLUE/ BLIND NAIL 9 TOP 16" O,C/ CAULK BOTTOM EDGE ROOF SHEATHING USE 8d RING SHANK NAIL ALL NAILS TO BE GALVANIZED AS PER B2304.1(3). 5TH EDITION (2014) FBC/RESIDENTIAL R80323.1/RI033 SPANISH TILE (RE -ROOF EXISTING WITH THE SAME) ROOFING OVER PEAL AND STICK POLYGLASS ROOF UNDERLAYMENT ON 5/0" PLYWOOD ON PE, R- ENG'D WOOD TRUSSE A 24" O C. SIMPSON #44ETA20 AT EACH TRUSS R-32 BLOWN - IN 5 �5/8" DRYWALL CEILING I MATCH EXISTING GALV, FLASHING ON I" X 2" P.TDRIP ON 2"X 10" FASCIA W/ 4X 14" CONCRETE 5 B RS CONTINUOUS TIEBEAM MATCH EXISTING STUCCO SOFFIT W/ CON'T. 1/2" DRYWALL ON I" X 2" P.T. p FURRING ON 3/4" RIGID INSULATION R-5A MATCH EXISTING 5/8" LIGHT TEXTURED STUCCO MATCH EXISTING e" X I6" CONC. BLOCK W/ POURED BLK. CELLS AT 8'-0" O/C MAX, 4 AT ALL WINDOWS, DOORS 4 CORNERS W/ 1-0 5 BAR DOWELED TO FOOTING 4 )?" W. X 4" H, CURB W/ HOOKED TO BEAM 1 BAR CONTINUOUS - WOOD BASE 3000 P.SU, FINISH GRADE 4" TWK. CONC. SLAB W/ roXb 10/10 WW r-, OR FIBER MES o - - 14" �- ro MIL o �VISQUEEN VAPOR BARRIER THICKENED SLAB EDGE 20" WIDE X 14" DEEP W/ 3• # 5 20 CLEAN COMPACTED 2500 PSF BARS CON'T. TERMITE TREATED SOIL 1�\�\ PROPOSED GARAGE ADDITION 1/2" " f"O" SPANISH TILE (RE -ROOF EXISTING WITH THE ROOFING OVER PEAL AND STICK POLYGI UNDERLAYMENT ON 5/8" PLYWOOD ON PER- ENG'D WOOD TRUSSES 6 24" O.C, — AT EACH TRUSS 12 5 MAT (STING -1 R-32 BLOWN - IN Lu ISOLATION 9" , MATCH EXISTING AMI f GALV, FLASHING ON I" X 2" P,TDRIP ON 2" X 10" FASCIA o o 0 5/8" DRYWALL CEILING 21. 0" �I 8" X 12" CONCRETE TIEBEAM TYP O-H. �I W/ 4 05 BARS CONTINUOUS MATCH EXISTING I� STUCCO SOFFIT W/ CON'T. VENT MATCH EXISTING 5/8" LIGHT TEXTURED STUCCO I MATCH EXISTING 8" X 16" CONIC, BLOCK W/ 1/2 DRYWALL ON I X 2 P.T. POURED BLK, CELLS I FURRING ON 3/4" RIGID O/C MAX. 4 AT ALL WINDOWS, INSULATION R-5A DOORS 4 CORNERS W/ 1-0 5 BAR WOOD BASE DOWELED TO FOOTING 4 HOOKED TO BEAM II 3000 P,SU, II 4" THK. CONC, SLAB W! 6X6 FINISH GRADE - 10/10 WAIT-, OR FIBER MESH 6 MIL ISQUEEN VAPOR BARRIER THICKENED SLAB EDGE 20" WIDE X 14" DEEP W/ 3- # 5 20 GLEAN COMPACTED PSF BARS CON'T. TERMITE TREATED SOR IL PROPOSED HOUSE ADDITION 1/2" " i'-0" L A V I-.1 WULJV DUL.R ANL.HUM I V 8'-0" HIGH DOOR W/ 6 - 3/5" X 3" SLEEVE ANCHORS ITT RAMSET / REDHEAD OHN-3830 OR EQ. SPACED AS REQUIRED BY MANUR AT EACH SIDE C_ RAGE DOOR ANCHOR DETAIL 1 1/2" = V- O" SPANISH TILLS MATCH EXISTING MATCH EXISTING STUCCO r TV 01 MATCH EXISTING 12 5 MORTAR TO TOP EDGE MORTAR FINISH SET HIP 4 RIDGE TILE IN CONTINUOUS BED OF MORTAR, LAPPING TILE I" MINIMUM. POINT MORTAR TO FINISH FULL BED OF MORTAR "TILE - TITE TDS" PROVIDE FULL BED OF MORTAR UNDER ALL HIP 4 RIDGE TILES BARREL RIDGE TILE MORTAR TO TOP EDGE MINIMUM I" THICKNESS UNDER TILE UNDERLAYMENT CARRIED OVER APEX OF ROOF FIELD TILE III a 11011 NOTE: SET HIP 4 RIDGE TILE IN A FULL BED OF "TILE - TITE TDS" BY PREMIX MARBLETITE MANUFACTURING CO. PLACE TILE ON MORTAR WITHIN 15 MINUTES PRESSING DOWN ON TILE UNTIL MORTAR HAS FULL CONTACT WITH THE TILE 4 EXCESS APPEARS AT THE SIDES OF TILE. POINT MORTAR USING MORTAR THAT IS SQUEEZED OUT WITH ADDITIONAL MORTAR AS NECESSARY 1/4" = I'-O" SOUTH NOTE = ALL COLORS, MATERIALS 4 FINISHES SHALL MATCH THE EXISTING HOUSE ALL FIELD TILES SHALL BE SET IN ACCORDANCE WITH SYSTEM #THREE FRSA 4 NTRMA TILE SPECIFICATIONS - MORTAR SET APPLICATION USING "TILE - TITE TDS" AS NOTED ABOVE CONCRETE 4 CLAY ROOF TILES COMPLYING WITH THE FOLLOWING LIMITATIONS SHALL BE DESIGNED TO WITHSTAND THE WIND LOADS PRESCRIBED IN THIS SECTION I, ROOF TILES SHALL BE MORTAR SET W/ "TILE - TITE TDS" BY PREMIX MARBLETITE MANUFACTURING CO, 2, ROOF TILES SHALL BE INSTALLED ON SOLID SHEATHING DESIGNED AS COMPONENTS 4 CLADDING IN ACCORDANCE WITH 1606.2, 3. AN UNDERLAYMENT SHALL BE INSTALLED IN ACCORDANCE W/ 1501.4 4. TILE SHALL BE SINGLE LAPPED INTERLOCKING W/ A MINIMUM HEAD LAP OF NOT LESS THAN 2 INCHES 5, TILE LENGTH SHALL BE BETWEEN IA 41,15 FEET 6, EXPOSED WIDTH OF TILE SHALL BE BETWEEN Ob141,25 FEET, 1. MAXIMUM THICKNESS OF TAIL OF THE ROOF TILE SHALL NOT EXCEED 13 INCHES 8. ROOF TILES SHALL HAVE AT LEAST 2/3 OF TILES AREA FREE OF MORTAR CONTACT GASTANKLE55 L J WATER HEATER nE�Ntl D Ty'• SCANNED Gy+J4 BY St LUCie Countv 'ILE ISTING ]STING VV �jw� a w VU � 0 a � o �v 1p L!16 Q � Q f� a 00 � 0 AND ALL PROPOSED lfflm- TO ANY CORRICTIO FIELD INSPECTORS T MAY BE NECESSARY IN ORDIR TO y COMPLY WITH ALL APPLICABLE COWS. w 111 Z U O � � U CONCEALED FASTENERS OR ATTAC N-. _ ARE THE RESPONSIBILITY OF CONTRACTOR OF RECORD m Q z Ell 0 � � 0 (L < Z R4%0-S30" 1810o 81isDt" 28 JUN 18 PROPOSED ADDITION EXISTING STRUCTURE 4�� �o�oo g File G p#Dan� 11165 2 9 J�--a OF EIGHT ICONA 1261