Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODE6A FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C�tM,7 CTION Florida Department of Business and Professional Regulation - Residential PerformiNpethod Project Name: GARREN RESIDENCE Builder Name: ASSOCIATED HOMES, INC. Street: 4606 BUCHANAN DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, Permit Number: Owner: W ILLIAM AND AMBER GARREN Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2054.6 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ftZ b. Frame - Wood, Adjacent R=11.0 226.33 ftZ 3. Number of units, if multiple family 1 c. N/A R= ftZ 4. Number of Bedrooms 4 d. N/A R= ftZ 10. Ceiling Types (2190.0 sqft.) Insulation Area 5� Is this a worst case? No a. Under Attic (Vented) R=30.0 2190.00 ftZ 6. Conditioned floor area above grade (ftZ) 2190 b. N/A R= ftZ Conditioned floor area below grade (ftZ) 0 c. N/A R= ftZ 11. Ducts R ftZ 7. Windows (204.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 176 a. U-Factor: Sgl, U=0.53 92.00 ftZ SHGC: SHGC=0.24 b. U-Factor: Sgl, U=0.55 60.00 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 42.0 SEER:16.00 c. U-Factor: Sgl, U=0.55 34.00 ftZ SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 18.00 ftZ a. Electric Strip Heat 27.0 COP:1.00 SHGC: other (see details) Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.241 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (2190.0 sqft.).) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ftZ b. Conservation features b. N/A R= ftZ None c. N/A R= ftZ 15. Credits None Glass/Floor Area: 0.093 Total Proposed Modified Loads: 64.62 PASS Total Baseline Loads: 70.73 I hereby certify that the plans and specifications covered by Review of the plans and THE Sx,1?, this calculation are in compliance with the Florida Energy specifications covered by this 0�, Code. calculation indicates compliance ��'�_ with the Florida Energy Code. PREPARED BY.' DATE: Before construction is completed this building will be inspected1for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. C a OWNER/EN _��N1/�l �' l/ BUILDING OFFICIAL: DATE: - ``--[[ DATE: - Compliance rpquiies certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7A0 ACH50 (R402.4.1.2). 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 PROJECT Title: GARREN RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area: 2190 Lot # Owner Name: W ILLIAM AND AMBER GARR Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: ASSOCIATED HOMES, INC. Rotate Angle: 0 Street: 4606 BUCHANAN DRIV Permit Office: ST'LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low ' BLOCKS Number Name Area Volume 1 Entire House 2190 19952 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 221 2011.1 No 0 1 1 Yes Yes Yes 2 WIC 1 32 259.2 No 0 1 Yes Yes Yes 3 WIC 2 36 291.6 No 0 1 Yes Yes Yes 4 MASTER BATH 174 1409.4 No 0 1 Yes Yes Yes 5 LIVING ROOM 151 1525.1 No 0 1 Yes Yes Yes 6 FOYER 104 1050.4 No 0 1 Yes Yes Yes 7 DINING ROOM 143 1444.3 No 0 1 Yes Yes Yes 8 FAMILY ROOM 320 3232 No 0 1 Yes Yes Yes 9 KITCHEN 190 1919 Yes 0 1 Yes Yes Yes 10 NOOK 88 888.8 No 0 1 Yes Yes Yes 11 BEDROOM 2 139 1125.9 No 0 1 1 Yes Yes Yes 12 CLST 2 16 129.6 No 0 1 Yes Yes Yes 13 CLST 3 18 145.8 No 0 1 Yes Yes Yes 14 BEDROOM 3 136 1101.6 No 0 1 1 Yes Yes Yes 15 BATH 48 388.8 No 0 1 Yes Yes Yes 16 BEDROOM 4 128 1036.8 No 0 1 1 Yes Yes Yes 17 CLST 4 18 145.8 No 0 1 Yes Yes Yes 18 LAUNDRY 66 534.6 No 0 1 Yes Yes Yes 19 HALLWAY 64 518.4 No 0 1 Yes Yes Yes 20 M TOILET 32 259.2 No 0 1 Yes Yes Yes 21 BATH 3 66 534.6 No 2 1 Yes Yes Yes 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 39 ft 0 221 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulation WIC 1 8 ft 0 32 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulation WIC 2 1 ft 0 36 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulation MASTER BATH 22 ft 0 174 ft2 0 1 0 5 Slab -On -Grade Edge Insulation LIVING ROOM 15 ft 0 151 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulation FOYER 8 ft 0 104 ft2 ____ 0 1 0 7Slab-On-Grade Edge Insulation DINING ROOM 11 ft 0 143 ft2 0 1 0 8 Slab -On -Grade Edge Insulation FAMILY ROOM 16 ft 0 320 ft2 ____ 0 1 0 9 Slab -On -Grade Edge Insulation KITCHEN 1 ft 0 190 ft2 ____ 0 1 0 10SIab-On-Grade Edge Insulation NOOK 8 ft 0 88 ft2 __e 0 1 0 11Slab-On-Grade Edge Insulation BEDROOM 2 19.9 ft 0 139 ft2 ____ 0 1 0 12SIab-Orr-Grade Edge Insulation CLST 2 1 ft 0 16 ft2 ____ 0 1 0 13SIab-On-Grade Edge Insulation CLST 3 2 ft 0 18 ft2 0 1 0 14SIab-On-Grade Edge Insulation BEDROOM 3 24 ft 0 136 ft2 0 1 0 15SIab-On-Grade Edge Insulation BATH 5 ft 0 48 ft2 ____ 0 1 0 16SIab-On-Grade Edge Insulation BEDROOM 4 11 ft 0 128 ft2 __e 0 1 0 17SIab-On-Grade Edge Insulation CLST 4 1 ft 0 18 ft2 ____ 0 1 0 18SIab-On-Grade Edge Insulation LAUNDRY 1 ft 0 66 ft2 0 1 0 19SIab-On-Grade Edge Insulation HALLWAY 1 ft 0 64 ft2 ____ 0 1 0 20SIab-On-Grade Edge Insulation M TOILET 12 ft 0 32 ft2 ____ 0 1 0 21SIati-On=Grade Edge Insulation BATH 3 6 ft 0 66 ft2 ____ 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch v # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2449 ft2 0 ft2 Light 0.6 No 0.9 No 0 26.6 ATTIC ` / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2190 ft2 N N 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 221 ft2 0.1 Wood 2 Under Attic (Vented) WIC 1 30 Blown 32 ft2 0.1 Wood 3 Under Attic (Vented) WIC 2 30 Blown 36 ft2 0.1 Wood 4 Under Attic (Vented) MASTER BATH 30 Blown 174 ft2 0.1 Wood 5 Under Attic (Vented) LIVING ROOM 30 Blown 151 ft2 0.1 Wood 6 Under Attic (Vented) FOYER 30 Blown 104ft2 0.1 Wood 7 Under Attic (Vented) DINING ROOM 30 Blown 143 ft2 0.1 Wood 8 Under Attic (Vented) FAMILY ROOM 30 Blown 320 ft2 0.1 Wood 9 Under Attic (Vented) KITCHEN 30 Blown 190 ft2 0.1 Wood 10 Under Attic (Vented) NOOK 30 Blown 88 ft2 0.1 Wood 11 Under Attic (Vented) BEDROOM 2 30 Blown 139 ft2 0.1 Wood 12 Under Attic (Vented) CLST 2 30 Blown 16 ft2 0.1 Wood 13 Under Attic (Vented) CLST 3 30 Blown 18 ft2 0.1 Wood 14 Under Attic (Vented) BEDROOM 3 30 Blown 136 ft2 0.1 Wood 15 Under Attic (Vented) BATH 30 Blown 48ft2 0.1 Wood 16 Under Attic (Vented) BEDROOM 4 30 Blown 128 ft2 0.1 Wood 17 Under Attic (Vented) CLST 4 30 Blown 18 ft2 0.1 Wood 18 Under Attic (Vented) LAUNDRY 30 Blown 66 ft2 0.1 Wood 19 Under Attic (Vented) HALLWAY 30 Blown 64 ft2 0.1 Wood 20 Under Attic (Vented) M'TOILET 30 Blown 32 ft2 0.1 Wood 21 Under Attic (Vented) BATH 3 30 Blown 66 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N Exterior Concrete Block - Polysty3TER BE 9 17 0 9 1 154.4 ft2 0 0 0.6 0 2 E Exterior Concrete Block - PolystyTER BE 9 , 13 0 9 1 118.1 ft2 0 0 0.6 0 3 S Exterior Concrete Block - PolysqqMMTER BE 9 9 0 9 1 81.8 ft2 0 0 0.6 0 4 N Exterior Concrete Block - PolystyrenANIC 1 9 8 0 8 1 64.7 ft2 0 0 0.6 0 5 N Exterior Concrete Block - PolystyTER BA 9 14 0 8 1 113.2 ft2 0 0 0.6 0 6 W Exterior Concrete Block - PolystyTER BA 9 8 0 8 1 64.7 ft2 0 0 0.6 0 7 N Exterior Concrete Block - PolystyNG ROO 9 3 0 10 1 30.3 ft2 0 0 0.6 0 8 W Exterior Concrete Block - PolysglEMNG ROO 9 12 0 10 1 121.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - PolystyrenEOYER 9 8 0 10 1 80.7 ft2 0 0 0.6 0 10 W Exterior Concrete Block - PolystylWNG ROO 9 11 0 10 1 110.9 ft2 0 0 0.6 0 11 E Exterior Concrete Block - PolystyFeWILY ROO 9 16 0 10 1 161.3 ft2 0 0 0.6 0 12 E Exterior Concrete Block - Polystyren&OOK 9 8 0 10 1 80.7 ft2 0 0 0.6 0 13 N Exterior Concrete Block - PolystyMIDROOM 2 9 9 0 8 1 72.8 ft2 0 0 0.6 0 14 E Exterior Concrete Block - PolystyM[DROOM 2 9 11 0 8 1 88.9 ft2 0 0 0.6 0 15 E Exterior Concrete Block - PolystyrenGLST 3 9 2 0 8 1 16.2 ft2 0 0 0.6 0 16 E Exterior Concrete Block - Polysty&EDROOM 3 9 11 0 8 1 88.9 ft2 0 0 0.6 0 17 S Exterior Concrete Block - Polysty&EIDROOM 3 9 13 0 8 1 105.1 ft2 0 0 0.6 0 18 S Exterior Concrete Block - PolystyrendBATH 9 5 0 8 1 40.4 ft2 0 0 0.6 0 19 S Exterior Concrete Block - PolystySEIDROOM 4 9 11 0 8 1 88.9 ft2 0 0 0.6 0 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 20 N Exterior Concrete Block - PolystyrdhbTOILET 9 4 0 8 1 32.3 ft2 0 0 0.6 0 21 W Exterior Concrete Block - PolystyrekbTOILET 9 8 0 8 1 64.7 ft2 0 0 0.6 0 22 S Exterior Concrete Block - PolystyrenBATH 3 9 6 0 8 1 48.5 ft2 0 0 0.6 0 _23 S Garage Frame -Wood DINING ROO 11 7 8 1 .56.6ft2 0 0 0.600000 0 _ 24 W Garage Frame - Wood LAUNDRY 11 21 8 1 169.8 ft2 0 0 0.600000 0 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Single Yes 0.45 0.26 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 2 ' E 2 Metal Low-E Single Yes 0.53 0.24 N 20.0 ft2 1 ft 0 in 1 ft 4 in None None 3 N 5 Metal Low-E Single Yes 0.53 0.24 N 12.0 ft2 1 ft 0 in 1 ft 4 in None None 4 W 8 Metal Low-E Single Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 5 W 10 Metal Low-E Single Yes 0.55 0.22 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 6 E 11 Metal Low-E Single Yes 0.55 0.25 N 60.0 ft2 1 ft 0 in 1 ft 4 in None None 7 E 12 Metal Low-E Single Yes 0.53 0.24 N 15.0 ft2 1 ft 0 in 1 ft4 in None None 8 E 14 Metal Low-E Single Yes 0.53 0.24 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 9 E 16 Metal Low-E Single Yes 0.53 0.24 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 10 S 18 Metal Low-E Single Yes 0.45 0.26 N 6.0 ft2 1 ft 0 in 1 ft 4 in None None 11 S 19 Metal Low-E Single Yes 0.53 0.24 N 15.0 ft2 1 ft 0 in 1 ft 4 in None None 12 W 21 Metal Low-E Single Yes 0.55 0.22 N 4.0 ft2 1 ft 0 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 441 ft2 441 ft2 28 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000405 2327.7 127.79 240.33 .2958 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 42 kBtu/hr 1260 cfm 0.8 1 sys#1 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert #', Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS -- Supply -- — Return — Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool ' 1 Attic 6 175 ft2 Attic 17 ft2 Default Leakage LAUNDRY (Default) c(Default) c 1 1 ' TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin Jan Feb [[ ]] Mar Apr [ j May Jun Jul AugnSep Oct Nov [ ] Dec Heating Jan Feb lxJ Mar Apr [ ] May Jun [ j Jul n [ ] Aug n Se Oct Nov [X] Dec Ventin Jan Feb [X] Mar [X] A r [ ] Ma Jun (] Jul [ ] Au Se [X] Oct Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (W EH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GARREN RESIDENCE Builder Name: ASSOCIATED HOMES, INC. Street: 4606 BUCHANAN DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: ' FORT PIERCE, FL, Permit Number: Owner: W ILLIAM AND AMBER GARREN Jurisdiction: Design Location:. FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting • Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Noina and wiring. Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Mates and walls or cellincis. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 91 The lower the EnergyPerformance Index, the more efficient the home. 4606 BUCHANAN DRIVE, FORT PIERCE, FL, 1., New construction or eAsting New (From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ft2 b. Frame - Wood, Adjacent R=11.0 226.33 ft 3. Number of units, if multiple family 1 c. N/A R= ft2 4. 'Number of Bedrooms 4 d. N/A R= ft2 10. Ceiling Types Insulation Area 5. Is this a worst case? No a. Under Attic (Vented) R=30.0 2190.00 ft2 6. Conditioned floor area (ft2) 2190 b. N/A R= ft2 c. N/A R= ft2 7. Windows- Description Area 11. Ducts R ft 2 ' a. U-Factor: Sgl, U=0.53 92.00 ft2 a. Sup: Attic, Ret: Attic, AH: LAUNDRY 6 175 SHGC: SHGC=0.24 b. U-Factor: Sgl, U=0.55 60.00 ft2 SHGC: SHGC=0.25 12. Cooling systems kBtu/hr Efficiency c. U-Factor: Sgl, U=0.55 34.00 ft2 a. Central Unit 42.0 SEER:16.00 SHGC: SHGC=0.22 d. U-Factor: other (see details) 18.00 ft2 13. Heating systems kBtu/hr Efficiency SHGC: other (see details) a. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 1.000 ft. Area Weighted Average SHGC: 0.241 8. Floor Types Insulation Area 14. Hot water systems Cap: 40 gallons 2 a. Electric a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2 EF: 0.98 b. N/A R= ft2 b. Conservation features c. N/A R= ft2 None 15. Credits None I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: IJAI,L Date: 441 Address of New Home: (AWVdAf in v City/FL Zip:ei *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1