HomeMy WebLinkAboutENERGY EFFICIENCY CODE6A
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C�tM,7 CTION
Florida Department of Business and Professional Regulation - Residential PerformiNpethod
Project Name: GARREN RESIDENCE
Builder Name: ASSOCIATED HOMES, INC.
Street: 4606 BUCHANAN DRIVE
Permit Office: ST LUCIE COUNTY
City, State, Zip: FORT PIERCE, FL,
Permit Number:
Owner: W ILLIAM AND AMBER GARREN
Jurisdiction:
Design Location: FL, Fort Pierce
County:: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (2054.6 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Polystyrene Bead AggrER=9.0 1828.20 ftZ
b. Frame - Wood, Adjacent
R=11.0 226.33 ftZ
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms 4
d. N/A
R= ftZ
10. Ceiling Types (2190.0 sqft.)
Insulation Area
5� Is this a worst case? No
a. Under Attic (Vented)
R=30.0 2190.00 ftZ
6. Conditioned floor area above grade (ftZ) 2190
b. N/A
R= ftZ
Conditioned floor area below grade (ftZ) 0
c. N/A
R= ftZ
11. Ducts
R ftZ
7. Windows (204.0 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 176
a. U-Factor: Sgl, U=0.53 92.00 ftZ
SHGC: SHGC=0.24
b. U-Factor: Sgl, U=0.55 60.00 ftZ
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
42.0 SEER:16.00
c. U-Factor: Sgl, U=0.55 34.00 ftZ
SHGC: SHGC=0.22
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 18.00 ftZ
a. Electric Strip Heat
27.0 COP:1.00
SHGC: other (see details)
Area Weighted Average Overhang Depth: 1.000 ft.
Area Weighted Average SHGC: 0.241
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (2190.0 sqft.).) Insulation Area
EF: 0.980
a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ftZ
b. Conservation features
b. N/A R= ftZ
None
c. N/A R= ftZ
15. Credits
None
Glass/Floor Area: 0.093 Total Proposed Modified Loads: 64.62
PASS
Total Baseline Loads: 70.73
I hereby certify that the plans and specifications covered by
Review of the plans and
THE Sx,1?,
this calculation are in compliance with the Florida Energy
specifications covered by this
0�,
Code.
calculation indicates compliance
��'�_
with the Florida Energy Code.
PREPARED BY.'
DATE:
Before construction is completed
this building will be inspected1for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
C
a
OWNER/EN _��N1/�l �' l/
BUILDING OFFICIAL:
DATE: - ``--[[
DATE:
- Compliance rpquiies certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with envelope leakage no greater than 7A0 ACH50 (R402.4.1.2).
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017
PROJECT
Title:
GARREN RESIDENCE
Bedrooms:
4
Address Type:
Street Address
Building Type:
User
Conditioned Area:
2190
Lot #
Owner Name:
W ILLIAM AND AMBER
GARR
Total Stories:
1
Block/Subdivision:
# of Units:
1
Worst Case:
No
PlatBook:
Builder Name:
ASSOCIATED HOMES,
INC.
Rotate Angle:
0
Street:
4606 BUCHANAN DRIV
Permit Office:
ST'LUCIE COUNTY
Cross Ventilation:
No
County:
St. Lucie
Jurisdiction:
Whole House Fan:
No
City, State, Zip:
FORT PIERCE,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location
TMY Site
97.5 %
2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI
39
90
70
75
299
62
Low
'
BLOCKS
Number
Name
Area
Volume
1
Entire House
2190
19952
SPACES
Number
Name
Area
Volume Kitchen
Occupants
Bedrooms
InfilID Finished Cooled
Heated
1
MASTER BEDROO
221
2011.1 No
0
1
1
Yes
Yes
Yes
2
WIC 1
32
259.2 No
0
1
Yes
Yes
Yes
3
WIC 2
36
291.6 No
0
1
Yes
Yes
Yes
4
MASTER BATH
174
1409.4 No
0
1
Yes
Yes
Yes
5
LIVING ROOM
151
1525.1 No
0
1
Yes
Yes
Yes
6
FOYER
104
1050.4 No
0
1
Yes
Yes
Yes
7
DINING ROOM
143
1444.3 No
0
1
Yes
Yes
Yes
8
FAMILY ROOM
320
3232 No
0
1
Yes
Yes
Yes
9
KITCHEN
190
1919 Yes
0
1
Yes
Yes
Yes
10
NOOK
88
888.8 No
0
1
Yes
Yes
Yes
11
BEDROOM 2
139
1125.9 No
0
1
1
Yes
Yes
Yes
12
CLST 2
16
129.6 No
0
1
Yes
Yes
Yes
13
CLST 3
18
145.8 No
0
1
Yes
Yes
Yes
14
BEDROOM 3
136
1101.6 No
0
1
1
Yes
Yes
Yes
15
BATH
48
388.8 No
0
1
Yes
Yes
Yes
16
BEDROOM 4
128
1036.8 No
0
1
1
Yes
Yes
Yes
17
CLST 4
18
145.8 No
0
1
Yes
Yes
Yes
18
LAUNDRY
66
534.6 No
0
1
Yes
Yes
Yes
19
HALLWAY
64
518.4 No
0
1
Yes
Yes
Yes
20
M TOILET
32
259.2 No
0
1
Yes
Yes
Yes
21
BATH 3
66
534.6 No
2
1
Yes
Yes
Yes
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017
FLOORS
# Floor Type
Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood
Carpet
1 Slab -On -Grade Edge Insulation
MASTER BEDRO
39 ft
0
221 ft2
____
0
1
0
2 Slab -On -Grade Edge Insulation
WIC 1
8 ft
0
32 ft2
____
0
1
0
3 Slab -On -Grade Edge Insulation
WIC 2
1 ft
0
36 ft2
____
0
1
0
4 Slab -On -Grade Edge Insulation
MASTER BATH
22 ft
0
174 ft2
0
1
0
5 Slab -On -Grade Edge Insulation
LIVING ROOM
15 ft
0
151 ft2
____
0
1
0
6 Slab -On -Grade Edge Insulation
FOYER
8 ft
0
104 ft2
____
0
1
0
7Slab-On-Grade Edge Insulation
DINING ROOM
11 ft
0
143 ft2
0
1
0
8 Slab -On -Grade Edge Insulation
FAMILY ROOM
16 ft
0
320 ft2
____
0
1
0
9 Slab -On -Grade Edge Insulation
KITCHEN
1 ft
0
190 ft2
____
0
1
0
10SIab-On-Grade Edge Insulation
NOOK
8 ft
0
88 ft2
__e
0
1
0
11Slab-On-Grade Edge Insulation
BEDROOM 2
19.9 ft
0
139 ft2
____
0
1
0
12SIab-Orr-Grade Edge Insulation
CLST 2
1 ft
0
16 ft2
____
0
1
0
13SIab-On-Grade Edge Insulation
CLST 3
2 ft
0
18 ft2
0
1
0
14SIab-On-Grade Edge Insulation
BEDROOM 3
24 ft
0
136 ft2
0
1
0
15SIab-On-Grade Edge Insulation
BATH
5 ft
0
48 ft2
____
0
1
0
16SIab-On-Grade Edge Insulation
BEDROOM 4
11 ft
0
128 ft2
__e
0
1
0
17SIab-On-Grade Edge Insulation
CLST 4
1 ft
0
18 ft2
____
0
1
0
18SIab-On-Grade Edge Insulation
LAUNDRY
1 ft
0
66 ft2
0
1
0
19SIab-On-Grade Edge Insulation
HALLWAY
1 ft
0
64 ft2
____
0
1
0
20SIab-On-Grade Edge Insulation
M TOILET
12 ft
0
32 ft2
____
0
1
0
21SIati-On=Grade Edge Insulation
BATH 3
6 ft
0
66 ft2
____
0
1
0
ROOF
/
Roof
Gable
Roof
Solar
SA Emitt
Emitt
Deck
Pitch
v # Type Materials Area
Area
Color
Absor.
Tested
Tested
Insul.
(deg)
1 Hip
Metal 2449 ft2
0 ft2
Light
0.6
No 0.9
No
0
26.6
ATTIC
` /
V # Type
Ventilation
Vent Ratio (1
in)
Area
RBS IRCC
1 Full attic
Vented
150
2190 ft2
N N
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
221 ft2
0.1
Wood
2
Under Attic (Vented) WIC 1
30
Blown
32 ft2
0.1
Wood
3
Under Attic (Vented) WIC 2
30
Blown
36 ft2
0.1
Wood
4
Under Attic (Vented) MASTER BATH
30
Blown
174 ft2
0.1
Wood
5
Under Attic (Vented) LIVING ROOM
30
Blown
151 ft2
0.1
Wood
6
Under Attic (Vented) FOYER
30
Blown
104ft2
0.1
Wood
7
Under Attic (Vented) DINING ROOM
30
Blown
143 ft2
0.1
Wood
8
Under Attic (Vented) FAMILY ROOM
30
Blown
320 ft2
0.1
Wood
9
Under Attic (Vented) KITCHEN
30
Blown
190 ft2
0.1
Wood
10
Under Attic (Vented) NOOK
30
Blown
88 ft2
0.1
Wood
11
Under Attic (Vented) BEDROOM 2
30
Blown
139 ft2
0.1
Wood
12
Under Attic (Vented) CLST 2
30
Blown
16 ft2
0.1
Wood
13
Under Attic (Vented) CLST 3
30
Blown
18 ft2
0.1
Wood
14
Under Attic (Vented) BEDROOM 3
30
Blown
136 ft2
0.1
Wood
15
Under Attic (Vented) BATH
30
Blown
48ft2
0.1
Wood
16
Under Attic (Vented) BEDROOM 4
30
Blown
128 ft2
0.1
Wood
17
Under Attic (Vented) CLST 4
30
Blown
18 ft2
0.1
Wood
18
Under Attic (Vented) LAUNDRY
30
Blown
66 ft2
0.1
Wood
19
Under Attic (Vented) HALLWAY
30
Blown
64 ft2
0.1
Wood
20
Under Attic (Vented) M'TOILET
30
Blown
32 ft2
0.1
Wood
21
Under Attic (Vented) BATH 3
30
Blown
66 ft2
0.1
Wood
WALLS
Adjacent Space Cavity
Width
Height
Sheathing Framing Solar
Below
1
N
Exterior Concrete Block - Polysty3TER BE
9
17
0 9
1
154.4 ft2
0
0
0.6
0
2
E
Exterior Concrete Block - PolystyTER BE
9 ,
13
0 9
1
118.1 ft2
0
0
0.6
0
3
S
Exterior Concrete Block - PolysqqMMTER BE
9
9
0 9
1
81.8 ft2
0
0
0.6
0
4
N
Exterior Concrete Block - PolystyrenANIC 1
9
8
0 8
1
64.7 ft2
0
0
0.6
0
5
N
Exterior Concrete Block - PolystyTER BA
9
14
0 8
1
113.2 ft2
0
0
0.6
0
6
W
Exterior Concrete Block - PolystyTER BA
9
8
0 8
1
64.7 ft2
0
0
0.6
0
7
N
Exterior Concrete Block - PolystyNG ROO
9
3
0 10
1
30.3 ft2
0
0
0.6
0
8
W
Exterior Concrete Block - PolysglEMNG ROO
9
12
0 10
1
121.0 ft2
0
0
0.6
0
9
W
Exterior Concrete Block - PolystyrenEOYER
9
8
0 10
1
80.7 ft2
0
0
0.6
0
10
W
Exterior Concrete Block - PolystylWNG ROO
9
11
0 10
1
110.9 ft2
0
0
0.6
0
11
E
Exterior Concrete Block - PolystyFeWILY ROO
9
16
0 10
1
161.3 ft2
0
0
0.6
0
12
E
Exterior Concrete Block - Polystyren&OOK
9
8
0 10
1
80.7 ft2
0
0
0.6
0
13
N
Exterior Concrete Block - PolystyMIDROOM 2
9
9
0 8
1
72.8 ft2
0
0
0.6
0
14
E
Exterior Concrete Block - PolystyM[DROOM 2
9
11
0 8
1
88.9 ft2
0
0
0.6
0
15
E
Exterior Concrete Block - PolystyrenGLST 3
9
2
0 8
1
16.2 ft2
0
0
0.6
0
16
E
Exterior Concrete Block - Polysty&EDROOM 3
9
11
0 8
1
88.9 ft2
0
0
0.6
0
17
S
Exterior Concrete Block - Polysty&EIDROOM 3
9
13
0 8
1
105.1 ft2
0
0
0.6
0
18
S
Exterior Concrete Block - PolystyrendBATH
9
5
0 8
1
40.4 ft2
0
0
0.6
0
19
S
Exterior Concrete Block - PolystySEIDROOM 4
9
11
0 8
1
88.9 ft2
0
0
0.6
0
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Below
Space
20 N
Exterior Concrete Block - PolystyrdhbTOILET 9 4 0 8
1
32.3 ft2
0
0 0.6
0
21 W
Exterior Concrete Block - PolystyrekbTOILET 9 8 0 8
1
64.7 ft2
0
0 0.6
0
22 S
Exterior Concrete Block - PolystyrenBATH 3 9 6 0 8
1
48.5 ft2
0
0 0.6
0
_23 S
Garage Frame -Wood
DINING ROO 11 7 8
1
.56.6ft2
0
0 0.600000
0
_ 24 W
Garage Frame - Wood
LAUNDRY 11 21 8
1
169.8 ft2
0
0 0.600000
0
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V #
Omt ID Frame Panes
NFRC U-Factor SHGC Imp
Area
Depth
Separation
Int Shade Screening
1
N 1 Metal Low-E Single
Yes 0.45 0.26 N
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
2
'
E 2 Metal Low-E Single
Yes 0.53 0.24 N
20.0 ft2
1 ft 0 in
1 ft 4 in
None
None
3
N 5 Metal Low-E Single
Yes 0.53 0.24 N
12.0 ft2
1 ft 0 in
1 ft 4 in
None
None
4
W 8 Metal Low-E Single
Yes 0.55 0.22 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
5
W 10 Metal Low-E Single
Yes 0.55 0.22 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
6
E 11 Metal Low-E Single
Yes 0.55 0.25 N
60.0 ft2
1 ft 0 in
1 ft 4 in
None
None
7
E 12 Metal Low-E Single
Yes 0.53 0.24 N
15.0 ft2
1 ft 0 in
1 ft4 in
None
None
8
E 14 Metal Low-E Single
Yes 0.53 0.24 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
9
E 16 Metal Low-E Single
Yes 0.53 0.24 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
10
S 18 Metal Low-E Single
Yes 0.45 0.26 N
6.0 ft2
1 ft 0 in
1 ft 4 in
None
None
11
S 19 Metal Low-E Single
Yes 0.53 0.24 N
15.0 ft2
1 ft 0 in
1 ft 4 in
None
None
12
W 21 Metal Low-E Single
Yes 0.55 0.22 N
4.0 ft2
1 ft 0 in
1 ft 4 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
441 ft2 441 ft2 28 ft
8 ft
11
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse Proposed ACH(50)
.000405 2327.7 127.79 240.33
.2958
7
HEATING SYSTEM
#
System Type
Subtype Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/
None COP:1
27 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency
Capacity
Air Flow SHR
Block
Ducts
1
Central Unit/
Split SEER: 16
42 kBtu/hr 1260 cfm 0.8
1
sys#1
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.98 40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert #',
Company Name
System Model # Collector Model # Area
Volume
FEF
None
None
ft2
DUCTS
-- Supply --
— Return —
Air
CFM 25
CFM25
HVAC #
V #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
QN RLF
Heat Cool
' 1
Attic
6 175 ft2
Attic
17 ft2 Default Leakage
LAUNDRY
(Default) c(Default) c
1 1
'
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Coolin Jan
Feb
[[ ]] Mar
Apr
[ j May Jun Jul
AugnSep
Oct
Nov
[ ] Dec
Heating Jan
Feb
lxJ Mar
Apr
[ ] May Jun [ j Jul
n
[ ] Aug
n
Se
Oct
Nov
[X] Dec
Ventin Jan
Feb
[X] Mar
[X]
A r
[ ] Ma Jun (] Jul
[ ] Au
Se
[X]
Oct
Nov
[ ] Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (W D)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
80
80 78 78
78
78
78
78
78
78
Cooling (W EH)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
80
80 78 78
78
78
78
78
78
78
Heating (W D)
AM
65
65
65
65 65 65
65
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
Heating (WEH)
AM
65
65
65
65 65 65
65
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
68
68
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: GARREN RESIDENCE Builder Name: ASSOCIATED HOMES, INC.
Street: 4606 BUCHANAN DRIVE Permit Office: ST LUCIE COUNTY
City, State, Zip: ' FORT PIERCE, FL, Permit Number:
Owner: W ILLIAM AND AMBER GARREN Jurisdiction:
Design Location:. FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
requirements
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with the
The insulation in any dropped ceiling/soffit
insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls shall
The junction of the top plate and the top of exterior walls shall be sealed.
be insulated by completely filling the cavity with a
Knee walls shall be sealed.
material having a thermal resistance of R-3 per inch
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and continuous
alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of insulation.
Floor framing cavity insulation shall be installed to
(including
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation shall
and cantilevered floors)
be permitted to be in contact with the top side of
sheathing, or continuous insulation installed on the
underside of floor framing and extends from the bottom
to the top of all perimeter floor framing members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with a
Where provided instead of floor insulation, insulation
Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to exterior
or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on installation
readily conforms to the available cavity spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting •
Recessed light fixtures installed in the building thermal envelope shall
Recessed light fixtures installed in the building
be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and
plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind Noina and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall be
on exterior wall
tubs shall separate them from the showers and tubs.
insulated.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be sealed
sprinklers
in a manner that is recommended by the manufacturer. Caulking or other
adhesive sealants shall not be used to fill voids between fire sprinkler
cover Mates and walls or cellincis.
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 91
The lower the EnergyPerformance Index, the more efficient the home.
4606 BUCHANAN DRIVE, FORT PIERCE, FL,
1., New construction or eAsting
New (From Plans) 9. Wall Types
Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Polystyrene Bead AggrER=9.0
1828.20 ft2
b. Frame - Wood, Adjacent
R=11.0
226.33 ft
3. Number of units, if multiple family
1 c. N/A
R=
ft2
4. 'Number of Bedrooms
4 d. N/A
R=
ft2
10. Ceiling Types
Insulation
Area
5. Is this a worst case?
No a. Under Attic (Vented)
R=30.0
2190.00 ft2
6. Conditioned floor area (ft2)
2190 b. N/A
R=
ft2
c. N/A
R=
ft2
7. Windows- Description
Area
11. Ducts
R ft 2
' a. U-Factor: Sgl, U=0.53
92.00 ft2 a. Sup: Attic, Ret: Attic, AH: LAUNDRY
6 175
SHGC: SHGC=0.24
b. U-Factor: Sgl, U=0.55
60.00 ft2
SHGC: SHGC=0.25
12. Cooling systems
kBtu/hr
Efficiency
c. U-Factor: Sgl, U=0.55
34.00 ft2 a. Central Unit
42.0 SEER:16.00
SHGC: SHGC=0.22
d. U-Factor: other (see details)
18.00 ft2 13. Heating systems
kBtu/hr
Efficiency
SHGC: other (see details)
a. Electric Strip Heat
27.0
COP:1.00
Area Weighted Average Overhang Depth:
1.000 ft.
Area Weighted Average SHGC:
0.241
8. Floor Types Insulation
Area 14. Hot water systems
Cap:
40 gallons
2 a. Electric
a. Slab -On -Grade Edge Insulation R=0.0 2190.00 ft2
EF: 0.98
b. N/A R=
ft2
b. Conservation features
c. N/A R=
ft2
None
15. Credits
None
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: IJAI,L Date: 441
Address of New Home: (AWVdAf in v City/FL Zip:ei
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/27/2018 9:05 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1