HomeMy WebLinkAboutWIND LOAD CERTIFICATIONr 14 PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite #114 SCANNED Port Saint Lucie, FL 34984 BY Phone (772) 785 - 9888 S4 Lucie County Paul Welch, P.E. Fla Reg No. 29945 JOB: SCHAFER DOCK 800 OSPREY CT. FORT PIERCE, FL WIND LOAD CERTIFICATION CODE: FBC/FRC 20171ASCE 7-10 WIND SPEED: 170 MPH, 3 SEC GUST EXPOSURE "D" IMPORTANCE FACTOR 1.0 INTERNAL PRESSURE COEFFICIENT: 0.00 DL ...... 5 psf LL ...... 40 psf WL ...... +44.01-61.6 psf NOTES. Fasteners in contact with preservative -treated wood shall be of hot -dipped zinc -coated galvanized steel, stainless steel, silicon bronze or copper. Fasteners other than nails, timber rivets, wood screws and -lag screws•shall be. permitted to be of mechanically deposited zinc -coated steel with coating weights in accordance with .ASTM 8 695, Class 55 minimum. Connectors that are used in exterior applications and in contact, with preservative —treated wood shall have coating types and weights in accordance with the treated wood or connector manufacturer's recommendations. In the absence of manufacturers recommendations, a minimum of ASTM A. 653, type 6185 zinc -coated galvanized steel, or equivalent, :Isholl be used. Two (2) fasteners per joist required for all decking equal to or less than 6" wide. Three (3) fasteners per joW required for all decking greater than 6" wide. For 1" composite decking, joist spacing not. to exceed 16" o.c. ALL LUMBER TO BE MARINE GRADE PRESSURE TREATED. PAUL wr:L.CH INC. ALL HARDWARE TO BE STAINLESS STEEL MECH-ELE cT-CIVIL ENG. 1984 BILTP,S r-E ST. #114 PORT SAINT -UCIE, FL 34984 PAUL WELCH R.E. FLA. REG :,,,0.29945 JuN..1 . - / a W / .. lr/ IV. N K 8" -9" 0 (0.40 CCA TREATED) WD. PILE I�2X6 WD DECKING ?,, T, 5/8" 0 S.S. THRU BOLT --I 2X8 - (I oR 2) (?ER PLAN) (0.40 CCA TREATED) WD STRINGER EACH SIDE OF PILE M- S/8" 0 S.S. THRU BOLT FnT__ - az-a ar a•i �. �� ti—c-.�c't�'_ 'G.`-... �,a +^lTi•e �t�vj �., 8'"" 0 PILE W/MIN. 6' PENETRATION TO RIVER BOTTOM OR AS NECESSARY TO ADEQUATE BEARING STABILITY ti .. a• 2X8 (0.40 CCA TREATED) WD JOIST —?—@ 16" O-C- MAX SPACING i i EACH JOIST ATTACHED TO EACH STRINGER WITH H 2.5 WITH (10)- 8d EACH • �x�y( Goe+G 2X8_P.T.-W-OOD LEDGER ATTACKED �i'O CONCRETE WITH %" X 3" TAPCONS A'1'7'rO:C. F- (4 - As TApeo?6 JOIST ATTACHED TO LEDGER TO G AP AO (J l WITH (LUS26 WITH (10)-10d) (�i-1112x L 1y� I JOIST NOTCHED AT EXISTING fro 7d �p CONC. SLAB AND. ATTACHED WITH Iti f) l 3/16" X I %" TAPCONS AT 24" O.C. DO NOT ALTER OR DAMAGE ANY SEAWALL TIEBACKS THAT MAY BE PRESENT PAUL WELCH INC. MECH-ELECT-CIVIL ENG. 1984 BILTMORE ST. #114 PORT SAINT LUCIE, FL 34984 PAUL WELCH R.E. - FLA REG NO.29945 Zdr 3 JUN 1 Z 2018