HomeMy WebLinkAboutALUMINUM ROOF.024 ALUM ROOF J .024 ALUM ROOF UDED ALUM. ATTACH RAIL
4' RIDGED POLYSTYRENE INSUTATKl4 T RIDGED POLYSTYRENE INSULATION w/N8X1 114 &M.8.3' O.C.
EXISTING MOBILE HOME ROOF UDED ALUM. ATTACH RAIL EXISTING PATIO ROOF BUTYL RUBBER SEALw/#8X1114 S.M.S. 3' O.C.
• BUTYL RUBBER SEAL
i r 024 ALUM FLASHING INTO PAN
�9 '� AND CAULK OR CONTINUE
i �i �� .024 ALUM FLASHING !l��:l�!�i FLASHING TO GUTTER
BUTYLRUBBERSEAL �'�<.�;;d 2481SMSw/NEOPRENE
l 114 ALUM. ATTACH RAIL WASHERS TO TOP OFEACH PAN
wl#8X1114 S.M.S. 3' O.C.
2X3 P.T. W/#BX3' W.S. @ 9' O.C. .024 ALUM ROOF 2X3 P.T. w#1W W.S. ® r D.C.
INTO EXISTING COACH FRAME INSULATION
2X3 P.T. BLOCKS CUT TO FIT INTO may!
PANS wl (2) #8 S.M.S. PER PAN NG
EXISTING COACH ' OVERHANG
FRAME POLYSTYRENE FOAM
EXISTING ALUM. INSERT EACH PAN
COL 8 BEAM
FASCIA EDGE DETAIL OR
GUTTER EDGE DETAIL
EXISTING PATIO ROOF
EXISTING WALLCHANNEL .024 ALUM ROOF
ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL W. rRIDGEDPOLYSTYRENEINSULATION
CONNECTION DETAIL (NTS) (NO 41h WALL) N.T.S. EXISTING MOBILE HOME ROOF
EXTRUDEDALUM.ATTACHRAIL
.024ALUM.ROOF wIN8X11MS.M.S.3'O.C. � �� �17
.024ALUMROOF-7 / 11
� TONTOPOF'7 / F TBUTYL RUBBER SEAL
r RIDGED POLYSTYRENE INSUUITIC
EXISTING MOBILE HOME ROOF -7
o
2X3 P.T. W/0
INTO EXISTING
2X3 P.T. BLOCKS CUTTO FIT INTO -
PANS w/ (2) 98 S.M.S. PER PAN
EXISTING COACH
FRAME
EXTRUDED ALUM. ATTACH RAIL
w! #BX7114 S.M.S. 3' O.C.
rBUM RUBBER SEAL
024 ALUM ROOF FLASHING
UDED ALUM. ATTACH RAIL
wl #8M 114 S.M.S. 3' O.C.
BUM RUBBER SEAL
�.024 ALUM ROOF
30# FELT ON TOP OF
EXISTING PANS w/
INSULATION INSERTS
EXISTING ALUM.
COL & BEAM
EXISTING PANS W —i
INSULATION INSERTS /
2X3 P.T. BLOCKS CUT TO FIT INTO)
PANS wl (2) #8 S.M.S: PER PAN
.024 ALUM FLASHING INTO PAN
" ,�/
AND CAULK OR CONTINUE
FLASHING TO GUTTER
2X3 P.T.
2-N8SMSwlNEOPRENE
INTO EX
WASHERS TO TOP OF EACH PAN
'
.024A�_ 'OFCONT.OVER
RIDGE WI FACTORY SEAMS ® 4B' D.C.
INSULATION
EXISTING —I
MOBILEHOMEROOF SINGLE WIDE (NTS)
CONCEALED � . Qm-
CONTRACTORN1
ARE TH .. OF RAINLESS STEEL HEX HEAD
ACHMENT RAIL TO EXISTING
MOBILE HOME FRAME @ 5' O.C. MIN.
INTO EXISTING FRAMING
EXTRUDED ALUM ATTACH RAIL 118'xT WIDE BUTYL RUBBER CONT.�
w/#8X1114 S.M.S. 3' O.C. .014 ROLL ALUMINUM
INSULATION
�BUTYL RUBBER SEAL ROOF
UREQE PLANS AfA4A'tI+td'lr w05lmUBJECT.T61dl�gpliIRED BY FIIsW b''bb uu ING
l � '
COACH AND PATIO ROOF
CONNECTION DETAILS
FOAM INSULATION
/1.024 ALUM ROOF
PATIO ROOF
PATIO PAN ROOF
Q
C
Q
tQo
to
o
V to
Q N
N
vi
w � w
tl
4
H
Q
BE NECESS U
'C01A1P1q 'H AL p LIKABLE DES..
024 UM EXTRUDED ALUMINUM ATTACHMENT
W/ STRAPS @ 4'-0 O.C.
��" lA,j�j /
(
EXISTING COACH
FRAME
EXISTING
OVERHANG
POLYSTYRENE FOAM.
-EXISTING ALUM
PAN
ncT
TT ER-EDG AI
� 1 1
COL 8 BEAM ' INSERT EACH .
-D-E
"N.T.S.
ALTERNATE PATIO PAN ROOF ATTACHMENT DETAIL T'
N.T.S.
v BUM RUBBER SI
2' RIDGED POLYSTYRENE INSULATION
ALTERNATE COACH & PATIO ROOF ATTACHMENT #2 . OVERLAPPING
024 ALUM R00�
CONNECTION DETAIL (NTS) (wl4th WALL)
.024 ALUM F
r RIDGED POLYSTYRENE INSULATION
EXSTING MOBILE HOME ROOF -7
2X3 P.T.
EXTRUDED ALUM. ATTACH RAIL
wl 08X1114 S.M.S. 3' O.C.
r-BUTYL RUBBER SEAL
r•024 ALUM ROOF
EXTRUDED ALUM. ATTACH RAIL
wl #8X11/4 S.M.S. r O.C. .024 ALUM F
2X3 P.T. w/#8X3'. 2' RIDGED POLYSTYRENE INSULATION
W.S. @ 3' O.C. EXISTING MOBILE HOME ROOF-,
EXISTING CENTER CAP J `"EXISTING COACH FRAMING
DQUBLE-WI—DE AIDG- DETAIL
N.T.S.
BUM RUBBER SEAL EXTRUDED ALUM. ATTACH RAIL
wlliA%S.M.S.3'O.C.
r RIDGED POLYSTYRENE INSULATION p,T. WOOD BLOCKw/
OVERLAPPING l #8X3' W.S. @ SPANNING
024 ALUM ROOF I TO STRAIGHTEN WOOD ONLY
EXISTING COACH
FRAME �/�'
LEisTINGPATIO ROOF
L MAX SPANI4'-0'
TAPERED INSULATION AS REQUIRED
STING WALL CHANNEL
FOAM FILLER
SAL"TERN(ATE4COACH 8_L PATIO:ROOF ATTACH ENT #3
EXasnNGCENTERCAP STING COACH FRAMING
CONNECTION DETAIL (NTS) (NO DROP BETWEEN ROOFS)
DOUBLE WIDE RIDGE DETAIL
USING ALTERNATE #1 ATTACHMENT (NTS)
_ MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C
NOTE:nISAL1EiUiAIE
MAr11Eus®roolurlx
rIL�EcnoNs
oFFnMaxO
nON
LL
SASMON
E
O
Z
0
RAILw/i8x1-1ASTAINLESS STEEL .
SCREWS @ 5' O.C. INTO N
EXISTING MOBILE HOME m
PRE -PUNCHED HOLES.
FRAMING6ROOFING
,ALTERNATE ATTACHMENT RAIL FASTENING #1
N.T.S... F to �
024 GALVALUME CLEAT .
480 O.C. (rya) t .
3 ,. CQTT.N-j T1 - nTi:-TcTn
.024' ALUM . -VIE _
RECEIVED D Fox C®
y j 1 V V C! w
E •.
.EI E of ^ SY
�•—�
j vq
FES 13 2018
DATE 3
�;
.'LA-NS ?LA-D PERIWT HUST R3
KEPT
O
Lucie County, Permitting -`� ® n,SPECTIO.i WILL BEE.
`"
ST,
�1
o
STYRENE-BUTADIENE
FACTORY SEAM DESIGN FOR RUBBER SEALANT
ZS
toW
(p
C
EXTRUDED ALUM. ATTACH RAIL
w/#8X11/4S.M.S.TD.C.
ALUMINUM ROOF COVERINGS—BETWEEN.SHEET-&,CLEAT
OVER SOLID ROOFS ONL
.�
4
-PRODUCT-AP-P-ROVALIFL5739„
,,—BumRUBBER SEaL
OVER ATTACHED STRUCTURES PRODUCT APPROVAL#FL17570-RO.
.024 ALUM FASCIA
fATADlACENT
N.T.S.
C
PATIO ROOF*
NOTES:
M
PROVIDE.024 FLASHING
INTO PATIO ROOF (MIN 87
1) THIS DESIGN CONFORMS TO THE 2017 FLORIDA BUILDING CODE FOR A�
CATEGORY IIIBUILDING FOR`WIND L AOAO DING OF 185 MPH EXPOSURE G AS
T�Q
wl#8 SMS ®12' O.C.
DETERMINED BYY CE'STANDARD•7.
Q
TING EXTRUDED
2.) HIS'DESIGN-CONFORIGS'TO-FCORIDKSTATUTE 15C-2.0081 FOR
MOBILEIMANUFACTURED HOME REPAIR AND REMODELING.
W
V h Q
WALL CHANNEL
3.) ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT -
SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM.
4.) THE ROOF COVERING SHALL NOT OVERHANG THE EXISTING ROOF.
1'
5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING
ROOF. THE STRUCTURE OF THE EXISTING ROOF SHOULD BE ABLE TO
SUPPORT THE CONSTRUCTION LOADING FOR THE NEW ROOF SYSTEM'
1 C
C C,
w N
S.) MAXIMUM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED 14'-0. O co
FASCJA.EDGE DETAIL. [ � 7.) MAXIMUM WIDTH OF A DOUBLE WIDE MOBILE HOME NOT TO EXCEED 2B'-0
N.T.S. St Lucie Goam g.� INSULATION
MAXIMUM HEIGHT OF MOBILE HOME NOT TOR
RIXCEED 15-0'ENE FORM APDX. DENSITY �#PER S.F. C to
.10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .024 ALUM. 03 4 CA
11.) THE R-VALUE OF THE 2' EPS INSULATION IS 11=65.7. CO
SHEETlte!'^ 1 O
OWNER l2 �QFS�ci ��tp o NOT VALID UNLESS D W 4
&SEALED WITH EMB�P> .
'ADDRESS: cll" N 1 `-T•r 3- QL V Cam. ENGI S SEAL
CfTY:Scta. SFr -A r- - STATE: �^_(,� ZIP:. 3y� S �l �Sll Z p
LOT# BLOCK# RANGE: JAMES BUSHOUSE, P.E. 0 =
PROFESSIONAL ENGINEER 20311 i i
STATE OF FLORIDA
T MIN THICK I
NOTE:
MAX 12
EXTRUDED ALUM. ATTACH
w/ #8X1 1/4 S.M.S. 3' O.C.
Inln.024ALUM CAP7
RUBBERSEAL.
i
2*x4' PT CONT. w/ #8x3' WOOD SCREWS @ 6' -
O.C. TO RIDGE BEAM & 1-#W' WOOD
SCREW TO EACH TRUSS
\ .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION
T ` ' 2 x4' WOOD TRUSS @
T T 24'0.C. w/ 1/2' SHEATHING EXTRUDED ALUM. ATTACH RAIL
w/ #8X1 114 S.M.S. 3' O.C.
BUM RUBBER SEAL
SEE GUTTER & FASCIA EDGE
DETAILS, S-1
2x4 P.T. w/#8x3'W00D SCREWS
cc
O
O
of
co
m
00
U
03
00
N
N
tl
@
MAX 28' WIDTH MAX 18' O.H. �
6' O.C. TO FASCIA 1-#W' Q
- TO EACH TRUSS TAIL @ 24'0.C.
CONTINUOUS
2 FASCA TYP.
PARK MODEL DETAIL A o
N.T.S.
Z W
O
" U
EXTRUDED ALUM. ATTACH RAIL BUTYL RUBBER SEAL
w/ #8X1 1/4 &WS. 3' O.C. m
.125d 2'x.024 ALUM CAPch
2 k4' PT CONT. w/2-i18x3' WOOD SCREWS TO EACH TRUSS
LAP OF ROOF ROLL TO BE, ON -
h
DOWNWARD $IDE . y "�
A'
ff \ \ .024 ALUM ROOF 2' RIDGED POLYSTYRENE INSULATION
2'x4' WOOD TRUSS (9 y
24'0.C. w/ 1/2' SHEATHING RUDED ALUM. ATTACH RAIL V k,
w/#BX11/4S.M.S.3'0.C. V - V
BUTYL RUBBER SEAL
' �01 1SEE f�� FASC AU D E$ co
m
DETAILS, S-1 vl
or
j co 0
2x4 P.T. w/#8x3'WOOD SCREWS 0�
MAX 14' WIDTH MAX 18' O.H.---� TOEACHTRUSS TAIIL @ 24'A wl 0 C. -
I
CONTINUOUS •
0
024 ALUM ROOF 2' FASCIA TYP. N
rFUDGED POLYSTYRENE uomaLUMATTACH RAIL PARK MODEL DETAIL B Ci
INSULATION w/88X1114SM.S.3'O.C. N.T.S. E,
BUMRUBBERSEAL W g ch
i �
024 ALUM FLASHING
63 3' MIN THICK BONDED PANEL r p
INTO
�N
2XT PTEDMEJ'SMS@4'EDP x��o
..NOTE: � EXTRUDED METAL 8 BONDED PANEL b
MAX 17 SPAN BONDED PANEL
O
j 1' MAX O.H
\ `.032 EXTRUDED FASCIA03
EXISTING ALUM. / EXISTING OR GUTTER t t�` C
COL RBEAM / OVERHANG
ORFRAMING - \\\\\\ SHEET No.: S2 "Of, 2
OWNER: NOT VALIDsUNLESS DATED .
ADDRESS:
�B-ONDED PANEL ROOF-EDGE_DETA[L#_1 s�SEALED WITH EMBOSSED 4
ENGINE 'S SEAL
CITY�j�
N.T.S. : STATE: 21P: rI '
Z 0
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C LOT# BLOCK# RANGE: JAMES BUSHOUSE, P.E.PR0FESSI0NALENGINEER20311 v
STATE OF FLORIDA