SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing. the use of
construction materials in the State of Florida. The documentation submittedhas been reviewed by Robert Nlemine,n,,P.E.
for use of the prodtfa under.- the, Fionda- Bowing --Code, and Florida-Ruifdfng;Code; Residential, Volume Tki —products-
described herein have been evaluated for compliance with the 6th Edition (20171- Florida Building_Code sections noted
herein.
P
DESCRIPTION: Polyglass Roof Underlayments
LABELING: Labeling -shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
-01NITINUE6—COMPLIANCE: This Evaluation Report'is Valid'britil such tiMe as th,e named'product(O 'afiges, the referenced
Quality Assurance documentation changes, or,provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the
z',e`terenced Quay :Rs L,rance ,docurraeata .ogres. Tr; :l y . i9.�req xes ,a.csar la ete..re�i�e�•d c : ls: a aa�t" is import
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT:- The Evaluation Report number preceded by the words "Trinity i ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
InISPEcriont Upon request; ,a copy, -af this -entire: Evaluation, Report shall be: provided to -the -user by the -,manufacturer or its
distributors and shall be available for inspection at the job site at the request of'the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by:
Robert J.M. lieminen, P.E.
Florida'Registration No. 59166, Florida DCA ANE1983
The facsimile seal appearing was authorized by Robert NIOMInen,
`P.E, an IWZI 1j°34i7. 'This clues 4tot3e/ve as an eleCh'ori r9ty
'CIRTMICATiCifil0"'VOMMMM signed document
1. Trinity IERD does not have, nor does it intend -to acquire or will it acquire; a financial interest in an
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturin or • y company /}1�nufaCturir
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in an cum
which the evaluation repotti are�/�eingtssued B distributing products it evalualbQg,
4. Robert Niemineh, P.E. does root I`rave„ nor will a.6 ire,.a financial interest in y pang manufacturin or distributin
g g prodUCtsi
product. an�othet � ,
5• This is a barrldpvrg code emfeation. 1 • entity involved in the a
re ar T i pERt nor Robert Pvrova� pirocess.of ti,
proJecf on wCt►ci1 this Evaivatron Report, or previous versions thereof, is/was�usecYtor
m��� P.E. are, ivr ar ..
specificallyfor.that'purpose. , tvte pesigrrer of
permitting or design guidon Record for arty
`e untess retained
Me coAv
ppppppp—
\JTR-1N1-TY'ERD'*
ROOFING COMPONENT EVALUATION:
1. SCOPE:
fir d[iG°l &t2 0Yy: npfjt g
Sub=Caftory: Underiayment
Compliance Statement. Roof Ljp#grljYM4nU, lS,prOduced d-'Pblyslass U5A, Jr c., #have demonstrated wona0ance with the
following sections of the a Edition (2014) Florida Building Code through testing in accordance with the following Standards.
Compliance is subjectto the Installation Requirements and Limitations / Conditions of Use set forth •herein.
2. STANDARDS:.
Section Property `Standard Year
1504.3.1 Wind Uplift Fld.4474
1504.3.11 wind upil t UL 1897 2012
1507.2.3 / 1507.1.1 Physical Properties ASTM D226 2009
1507-2.4,1ISQ7.1.1,15W.2.9.2 PhVsiratPropeuties ASTMD1970 zus
1507.3.3 Physical Properties FRSA/TRI April, 2012 2012;
1507:111 Physical Properties ASTM D6164 2011 .
1507.11.2 Physical,Properties ASTM D6222 2011
1523.6.5.2.1 Physical Properties TAS 103 , , 1995 ...,.
TAS 110 Accelerated Weathering TAS 110 2000
3- `:REF€i2ENtESt
Enilty
4W AWmAs ITST 19671
PRI (TST 5878)
PRI (TST 5878)
PRI (TST 5878)
PRI, (TST 5878)
PRI (TST 5878)
PRI, (TST 5878,
PRI (TST 5978,)
PRI (TST 5878)
PRI; (TST' 5979)
PRI (TST 5878)
PRI (TST S%78�
'PRI V57 5878)
^i (TST 5a78�
I tiS� 5a7a)
A,kTST 2509.1
Id4 �5�)
RD (TST 6049)
:RD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (sr 6049)
ERD (TST;6049);,
ERD T56)
ERo(nT
�E( D( tTSTriiw%
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
Q�ri r.+{t s�anch Ml D-signs"LLC.
eo#�uti+a�rot+on4903
Examination
V,gnd `Uplift
.Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
PhYA*.Pw,er*' .
PhyslC* Properties
Physical Properties
PhysiW Properties
Physical Properties
physical Properties
PhySlcal Properties
Physical Properties
Physical Properties
; .klY4icai:#'roper es
�i+ysic�i �perties
Physical Properties
Mind UPirl`t
Wind UPiift
Physical`Properfies
Wind Uplift
Physical Properties
Wind Uplift _.
QhYSaPrQPi"es".
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Physical Properties
Reference
3004091
PR101111
PUSA-005-02-01
PUSA-013-02=01
PUSA-013-02-02
PUSA-013-02.03
PU$A-001"2�0T^ -
KSA-028-0r 0'P
PUSA-033-02-01
POSA-035-02-01
PUSA-055-02-02
PUSA=061-02-02
PUSA-076-02-01
PUSA-093-02-01
PUSA-088-02-01
RX14ESA
11752.09.99-1
11-7557.68,01-1
11776,06.02
02200.07.03.
P1740.01.07
P5110.04.07-1
P9260.03.08
Px34<5Q'a1309•� .
p30540.21.09-RI
P 11030.11.09-1
07.1030.11.69-2
P11030.11.09-3
P33360.06.10
P33370.03.11'
P33370.04.11
P37300.10.11
�'"�.are� Ic�rn qzal�9�c svor��trz`�r��.�a�to'ro
Polyglass Roof Underlayments; (570) 384-1230
Date
01/12/2000
P4/08/2002
01/31/2002
12/13/2002
12/23/2002
12/23/2002
07/P3/Z005
01/12/2006
09/29/2006
12/10/2007..
01/28/2008
02/22/2008
04/14/2008
07/29/2009
; �0410 i2008
o1J29/20tf9
62/08/2000"
09/1312001
.01/16/2003
07114/2003"
'01/04/2007
04/11/2007
03/21/2008
og(WZoo
IiP rem
11/30/2009
11/3012009.
11/30/2009..
06/25/2010.
03/02/2011
04/26/203.1
10/19/2011
valuation Report p1221
060:02 09 RV
-RV
Revision Revision 23: 09/14/2017
'Page 2 of 14
.}
Entity. ,
ERD;.(TST:6049)
ERD (TST 6049)
-TRD (TST 6049)
ERD (TST 6049)
ERNTSf,,6949)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD .(TST 6049),
ERD (TST 6049)
ERD (TST 6049)-
ERD "(TST 6049)
ERD. (;TiSTi 604%
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
,ERQ jT&T:.6049j
ERD (TST 6049)
-_MD (TST-6049)
ERD (TST 6049)
FRID1(TS- Tt6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 6049)
ERD (TST 60491
ERD (TST 6049)
ICC-ES (EVE 2396)
Miami -Dade (CER 1592)
Polyglass USA
Polyglass USA
Polyglass USA
UL, I.I.C. (QUA9625)
4. PRODUCT DESCRIPTION:
Examination
Physical'Proper#ies
Physical Properties
-Phys i cal -P ro p e rt i e s
Wind Uplift
P.l jysiGaI'Properties
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Wind Uplift
Physical Properties
Physical Properties
Physical Properties
PhysicarProperVes
Physical Properties
Physical Properties
Physical Properties
Physical Properties
..Physical P.jrnpertie6
Physical Properties
Physical Properties
Physical Properties
,-?hysical:'P_roperties
Wind Uplift
Physical Properties
Wind Uplift
Physical Properties
Physical Properties. -
Physical Properties
BC Compliance
HVHZ Compliance
Manrlfactaring,Affidavi.t
P/L Affidavit
Materials Affidavit
Quality Control
Reference
P40390.08.124
P40390.08.12-2
C41420.09.12-3
P39680.03.13
'P45330:04;13 '
P1738.02.07-112
11757.04.01-1-R1
P41630.08.13
P11751.05.03-R1
P11781.11.03-R1
P45270.05.14
6020:07.144
6020.09.14-2
60200914=3`•.
6020.09.14-4
6020.09.14-5
6020.09.14-6
P46520.10.14
P44360.10.14
P43290.10.14
?LYG-SC7550:03.15
P40390.04.15
..''PL?f�Gsa'C83S0:05:15-1
PLYG-SC8905.05.16-1
PLYG-SC8080.07.16
PLYG-SC12025.10.16
PLYG-SC13040.12-.16
PLYG-SC11900.03.17
PLYG-SC12115.08.17
ESR-1697
NOA 14-0717.08
Prodlrcts CarrenV
Mule -Hide Cross Ltg
Polystick SA Compound
Service Confirmation
TRINITY I ER®
Date
:08/D6/2012
08/07/2012
09/11/2012
03J04J2013 .
tW2faJ2013
04/29/2013
04/30/2013
08/06/2013
11/26/2013
11/26/2013
05/12/2014
09/08/2014
09/08/2014
0910817-014:
09/08/2014
09/08/2014
09/08/2014
16/03/1014
10/07/2b14
10/17/2014
03/24/2015
04/03/2015
,05/20/s201s
05/17/2016
07/16/2016
10/12/2016
12/27/2016
03/10/2017
08/08/2017
11/01/2014
01/22/2015
02/19/2009
03/01/2008
08/18/2011
Exp. 10/05/2018
-
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet.
4.1.2 `ioftmen''basesheek.
4.1.3 Polyglass G2 Base is a fiberglass -reinforced, asphaltic base sheet.
4.1.4 Polyglass APP Base is a fiberglass -reinforced, APP modified bitumen base sheet.
4 2 Self-Asthsring U_ nd�rlayments� _ --
4.2.1 Polystick MTS is a nominal 60-mil thick rubberized asphalt waterproofing membrane,. -glass fiber reinforced, surfaced
with polyolefinic film surface; meets TAS 103,
4.2.2 Polystkk I-R-Xe is a: non%h%ali60-m.Wthk, k RrrEtFserFzed.aspFralt.uvtaterprocrfirig rnettialsrarre,. gjass fiber reinforced; witir,am
aggregate surface; meets ASTM D1970.
4.2.3 Polystick TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and TAS 103.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-R23
Certf cdte of Authd4zation'#9503 67N EDMON (2017)'FEC NON44VHZ EVIit.LIATION R5259-R27
Polyglass Roof Underlayments; (570) 384-1230, Revision 23: 09/14/2017
Page 3 of 14
TRINI-rY ERD
4.2.4 Polystick TU P is a nominal 130-mil thick rubberized asphalt waterproofing membrane, glass-fiber/polyester
netrif*ced,`ai kh a grandlar,surface; mews ASi'�M 01970 and TAS 103.
4.2.5 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 _polyester
fabric surface; meets ASTM D1970 and TAS 103.
4.2.6 P.olyf X-SAP, Poiyf)ex SAP FR, Male -Hide •SA=APP C'ap •Sheet and Iilfdte=Hide SA4PP' ,ap Sheet (FR) are polyester
reinforced, APP modified bitumen.cap sheets; meet FRSA/TRI April 2012.
4.2.7 Polystick Dual Pro'"' is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970.
4.2.8', Pafystkkc,Tlfe Pro?.-- fs a: riarninah 60 rnll.tihicic duel` -lay r=4'6eriked','asph4it<.,wateupaoofi'ng membrane, fiberglass
reinforced; with a polyester fabric surface; meets ASTM D1970 and TAS 103.
4.2.9 Polystick MUwX is a nomina6 54-mO thick duaMayer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film -surface; meets AC188 and physical. requirements of, ASTM.D1970,(See.Section.
5.8).
x . / ided Underlayments
4 3 Mechanically Fastened and or Bon
,.
F.
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
moi9lf#etl' situtnen.loa lc-';ide'azid=:gr�anUie su.rfaced.,A�-:P-MO&f idJ9-tume.n4:op-side. �i£la t lax C Tll sds;.�for use as an
alternate to "IViineral Surface Roll ,Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April
2012 (04-12) beneath-rrmechanically fastened -tile roof systems or Hot Asphalt applied "Cap Sheet" in the "Two Ply
System" from FRSA/TR1 April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
4.3.2 Elastoflex S6 G and Elastoflex S6 G'FR are polyester reinforced, SBS modified bitumen cap sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
Class M) in the "Single Ply system";from FRSA/TRI April 2012 (04-12) beneath mechanically fastened the roof systems.
Elastoflex S6 G is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
Apcili'2Q32''(04=]`j beneath rneckvantcally fastened or ad4roeE'ed file roo€ systems. Elastoflex S6 G FR' is far use as an,
alternate to Hot Asphalt applied "Cap Sheet" in the "Two. Ply System" from FRSA/TRI April 2012 (04-12) beneath
mechanically fastened-tke roof systems.
4.3.3 Polyflex G, and PolyfJex G. FR. are polyester. relrfq�ced,. AP,P modified. bitumen cap- shpetsp meet; ASTM D622 :.
Polyfle'x G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04-12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LWITATtYW.
3.1 This :is a building code eva cation. Neither Trinity4 ERR nor Robeyt Nieraiinen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in the HVHZ.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 P�g+glass.E oat Uvtdeirl«yrrYr rrts n?ay be used witOt any preps-red.rcof cover where the product is specificallTreferenced•
within FBC approval documents. If not listed, a request 'may be made to the Authority' Having. Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
Exterior Research and Design, I.I.C. Evaluation Report P12060:02.097R23
Certycate ofAuthorkotion #9503 6' EDITION 12017) FBC NON-HVHZ EVALUATION' FL5259-R27
Polygiass Roof Underlayments; (570) 384.1230 Revision 23:.091,14/2017
Page 4 of 14
C
\J"TRINITYIERD
5.5 Allowable Roof Covers:
ABLE , ROOF COVER'OPTIONS
Underlayment
Asphalt Shingles
Nail -On Tile
Foam -On Tie
Metal
Wood Stsa'tes
& Shingles
Slate
tes
(Base Sheet net -ply system) r
(Base Sheet n2 ply system)
yes
es
'Yes
Elastobase P
Yes
Yes
(Base Sheet In 2-ply system)
Yes
(Base Sheet in 2-ply system)
Yes
Yes
Yes
Polyglass G2 Base
No
Yes
(Base Sheet in 2-ply system)
Yes
(Base Sheet in 2-ply system)
No
No
No
Polyglass APP Base
No
Yes
' (Base Sheet in 2-ply system)
Y
(Base Sheet in 2-ply system)
No
No
No
Polyst(cF MTS
Yes
Yes
No
Yes
Yes
Yes
Polystick IR-Xe
Yes
No
No
No
Yes
Yes
Polystick.TUPL
Yes
Yes
Yes (seeas-I}>r:
IVac
Y;es,
Yes
Polystick TU Plus
Yes
Yes
Yes (See 5.5.1)'
Yes
Yes
Yes
Polystic TU Max
No
Yes
Yes (See 5.5.1)
Ye
No
No
Polystick Dual Pro
es
No
Yes
Yes
Yes
Polystick Tile Pro
Yes
Yes
Yes (See 5.5.1)
Yes
Yes
Yes
PoiystickMU=X
Yes
No
'No
Yes
'Yes
Yes
Elastoflex S6 G
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Elastdflex 56 G FR
Yes
Yes
No
No
Yes
Yes
Elastoflex G TU
Yes
Yes
Yes ,(See 5.5.i
No
Yes
Yes
P'otyfleo G
Vies
'>Yes
yes : 5ee'Si5:t1)
Yes
yes
Polyflex G FR
Yes
Yes
No
No
Yes
Yes
Polyflex SAP or SAP FR
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
Mule -Hide SA-APP Cap Sheet
or SA-APP Cap Sheet (FR)
Yes
Yes
Yes (See 5.5.11.
No
Yes
Yes
5.5.1 "Foam -On Tile" is limited to use of the following Approved the adhesives / underlayment combinations.
TABLE".1A:`ALLOINABLE
/ .• 1
TILE ADHESIVE' UNDERLAYMENT COMBINATIONS
AdYfesWe-
= Fibride Pcodtrct
t3nderfaymenfs
Approval
DAP Foam Touch `n Seal StormBond Roof
Tile Adhesive
FL14506
Polystick TU Plus, Polystick TU Max
Dow TileBondT1
FL22525
Polystick TU P, Polystick TU Plus, Polyflex SAP or Tile Pro
PolystickTU P, PolystickTU Plus, PolystickTU Max,.PolystickTile Pro,
4CP Adhesim 9&hpW-AfA-160
646332
Elastoflex r3 TU, VastofSex S6 G, .PofyfAex G, .FWlyWex SAP; Polyflex SA'Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
iRalYSick �-UUJP„Paiys`&k Tf UJ P.bus; IPxi lys'ti:ckiTLI!Max,, P?o ystitk-xZil2 iRro,
ICP Adhesives Polyset® RTA-1
FL6276
Elastoflex G TU,'Elastoflex S6 G, Polyflex G, Polyflex SAP, Polyflex SA Cap FR,
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polyglass PolyLok Roof Tile Adhesive
FL17855
Polystick TU Plus or Polystick TU Max
1'Refer-to Trle`Monttfa`cturel's orAdhesive'lwanufacturer's'flortdd'Product approval for'CJveftUrning Moment"Resistance `Performance.
Exterior Research and Design, LLC. ' Evaluation Report P12060.02.09-R23
Certificate of Authorization n95t13 6T" EDITION (2017)"FBC'N0N-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments; (570),384-1230 Revision 23: 09/14/2017
.,Page-5:df 14
P1, R, IE D
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to:
➢ New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New -or existing, unprimed OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Sot f enn �'alfaw Pure; AS M:,. d42+` pv!Med,: struetu'e&--concrete; Liuber, Eng4neered.; Un beds• °`2i,B� SysteW- Pacrelb
(designed and installed to meet wind loads for project).
Note. Polyglass-does- not require priming of new or existing plywood or OSR sheathing. New or existing pilywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick .membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
➢ ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FR torch -applied -to:
➢ ASZl1l1,D4,1,prt�ecl st�tActtral.co�c�>e.,
5.E.2 'Bond -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP F-R, Mule -Hide SA-APP Cap Sheet or- SA-APP Cap Sheet (FR) self -adhered
to: '
➢ ASTM C1289, Type II, Class 1 `polyisocyanurate or Type V polyisocyanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime; or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S6 G or•Elastoflex S6 G FR in hot asphalt to:
➢ Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board:
Polyflex G. or Polyflex G FR torch-applled-to:
➢ ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared raof`coverhrg•manufacturer`s P"rodbct•'Approval: Fdr instaflations underfoam-on tiie
systems, insulation attachment shall be designed, by a qualified design professional and installed based on testing of
the insulation/underlayment system in accordance with FBC Section 1504.3.1.
5.6.3 Bond to Mechanically Attached Base Laver:
'iP4*sb&44)1vahations), °;Polyflex SAP -or SAP �FR,WW6441de SA-APP.Ca;p Sheet or SA-APP'"Cap'Sheet JFR),Dual Pro or
Tile Pro self -adhered to:
➢ AST•tii .D226, Type l or R felt; Elastobase; Elastobase P or Mule -Hide Nadd Base.
.Elastoflex G TU, Elastoflex S6 G.or Elastoflex S6 G.FR in.hot.asphalt,to:
➢ ASTM D226, Type I or II felt; Elastobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR torch -applied to:
➢ Elastobase;'Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Polyglass APP Base.
OstallaRltas under n ebapt tally.:aftackr—ed; pr@pax.ed,roof. coverings; ba'selayer, 0all. ,be. attached. per, In inftiuftv..
codified requirements. For rnstaffations under foam -on We systems, base rayer shall be attached per minimum
requirements of. FRSA/T.RI.April..2012 (04-12); Appendix A, Table 1, or as listed. in Section. 5.6.4 herein, or as testedin
accordance with FBC Section 1504.3.1.
Exterior Research and Design, LLC. Eva luation.Report.Plmomm.o9,R23
Certftate of Authorization #9503 6' EDITION (2017) FBC NON-HVHZ EVALUATION ' FL5259-1127
Polyglass Roof Underlayments;;(570) 484.1240 Revision.23: 09/14/2017
Page 6 of 14
TRINITY ( ERD
1
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012' (04-12) does not
:address wind -uplift resistaliee.rif.'all t nderiaymimit=systems beneath-foam=an file systems, where "the'underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wired ioad resistance braced on allowable vrind toads, and reflects the ultimate ,passing pressure
divlded'by Vjf'he`210 3 margin'of safety per `FSC I.504:9`has Jlready'been applied).'Rdfer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch"plywood to meet project requirements to satisfaction of Authority-Having.Jurisdiction.
Primer, (None
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mute -Hide SA-APP Cap Sheet (FR), self -adhered.
#2 Maximum Design Pressure = -97.5 rosf:
Deck: fi Y6. f5'/32-Inch plywood fa meet projecfrequrremenrs to satisfaction of Authority ftav'r`ng Purrsdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga, x
1X" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch oic.
#3 Maximum Design Pressure = -105 psf:
Deek- Min. 15/32-inch plywood to meet project requirements to satisfaction of AuthontyHaving Jurisdiction.
Primer: WB-3000
Underlayment: Polystick TU.P,.Polystick.TU,P.i.us,.Paiystick TLI.,-Max,,Pbjy,Rex SAP,..Polyflex SAP,.FR,,Mule Hide SA-AP:P Gap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga, x
1'/0" ring shank nails through 32 ga., 1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure = -135 psf:
"Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Ptirrrer. (Opfionalj'PG100'orA9TiW11341
Joints: Min. 4-inch wide strips of Elastoflex SA-V over all plywood joints.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (,FR), self.-adhered-
#5 Maxi''MVft :Des1jK'P1tessrire = -gfSS6 .-
Deck: , Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Tile Pro, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure = -622.5 msf:
Deck- Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PG100 or ASTM D41
Underlayment: Elastoflex G TU or.Elastaflex S6 G, applied.in,full•mopping.of,hbt ,aspfialt or:Potyfiex-,G, R•omh ,pplied.
#7 Maximum Design Pressure = -30.0 psf*:
Deck: Min. 15/32-inch OSB to meet project requirements'to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga: x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 64nch o.c. at the',5-lnc6 wldesf"de-laps and 6"--inch a.c. at two-(2yequally spaced`staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#8 Maximum_ Design Pressure = 47.5
Decit F14i'rr: 7:5/k4hch.0yw6odi6 meefprolecfrequrrements to satisfaction of Authority Ytaving Jurisdiction.
Base Sheet: Elastobase or•Mule-Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
'Mute -hide SA=A*Cap'Sheet(FR), self -adhered.
Exieriw%eseareh and Design, ILIK. Evaluation Report P12060.02.09-R23
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.5259-1127
Poi 91M ft-f Underiayrments;1570) 384-IZ30 'Revision 23: 0911412017
'Page 7 61 i4
TRINITY ERD
I
#9 Maximum Design Pressure = -37.5 psf*:
tleok: Mira.. irJ331rrafi ywocd�toare�ee "�roJert r egtiirernerits to`sxti3faiKian of l rfhorlry Naving lmrisdiction.
Base Sheet: One (1) or two (2) layers ASTM D226, Type 11 felt
Fasteners: 11 ga. x 1.25-inch long x 1-inch head diameter round metal cap nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
.Underlayment:.,Elastoflex.:G TU orflastoflex S5:iG,.appl1ed:jn full MoppJng-of hot=asphalt.
#10 Maximum Design Pressure = -45 osf*:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: One (1) layer ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-lrlch'o.c. at 2-inch wide sine laps ancV44nch o.c. at two ('21 equalJji spaced'stag,gered'center roius.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered or Elastoflex G TU, applied in full mopping of hot asphalt.
#11 Maximum Design Pressure = -45 psf*:
Deck: -Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Two (2) layers ASTM D226, Type II felt
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing; 9-inch o.c. at the 2-inch wide side laps and 9-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: ,Pp)ystiO,.T,q P..P9j.ysti4k TU P{y�s;:Polys;i Ic 7A1 11(Iax, Polyyflex SAPI?tcol hex SAQ f;, f +}lp- jde 5�4-APp ccla Sjyeer ON
'Muffle -Hide SA -API' Cap Sheet (R), seWadher ed or Vastaflex G TU or''Gastofiex S6 6, applied in full mopping of hot
asphalt.
#12 Maximum Design Pressure = -45 psf:
Q�C* ;MITI, 15/32-4nch!.plywtood,to meet project requiremems.to satisfaction of Authorlty Having lurisdictio'n.
Base Sheet_: Elastobase (sanded top surface for Not-asphaltor torch -applied cap or poly-fiim surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-inch o.c. at the 2-inch wide side laps and 18-inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#11 Maxi9nurri`Design Pressure = -52.5 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet. Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9=inch o.c. at the 2-inch wide side laps andi2-Fnch o.c. at two (2)' equalTy spaced staggered center rows.
Underlayment: Elastoflex G TU. or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflez G, torch -applied.
#14 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
,Base Sjteet: lag ase.Ar, je-1 kl a ); ase.4Pcly j ecp- rf ce)
fasteners: Simplex Original Cap Nails
Spacing: 6-inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Polystick TU P, Poiystick TU Pius, Polystick TU Max, Polyflex SAP, Polyflex SAP F11, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet,(FR),.se(f:adhered.
#15 Maximum Design Pressure = -52.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: 6-inc orz atA a 34clvwidi side laps an&6 6i cW or.c. atibur('4yequa*spaced staggered, center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or-Polyflex G, torch -applied.
#16 Maximum Design Pressure = -W psf:
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority, Having. Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 11 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 8-inch o.c. at the 4-inch wide side laps and 8-inch o.c, at three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
Exterior Research and Design, I.I.C.
Certiillcate of Authorization #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION
.Polyglass:Roof Undedayments; (570)384-1230
.Evaluation.Report 1)12060.02.09-.1123
FL5259-R27
Revision 23:.09/14/2017
Page 8 of 14
1®RINI- Y J ERD
#17 Maximum Design Pressure = -60 psf:
Deck: Min. 19f32-ipchplywood:.to..meetprojecS;tegyifet>3 mts..to:satisfact)on.ofAuthorityHaving:Junisdktion.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
fasteners: OMG #12 Standard Roofgrip with OMG fiat Bottom Metal Prates
Spacing: 12-inch o.c. at the 4-inch wide side laps and 12-inch o.c. at two (2) equally spaced staggered center rows.
Underiayment:.fiastbftex G:TU Dr.Elastoflex 56.G, applieci.in fnali mvppisrg of;hot asphalt.or,,Roiyflex.G,,toreh,appiied.
#18 Maximum Design Pressure = -67.5 psf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: 12 ga. x 1.25-inch long x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 84nch o.c. atthe 4-inch wide-sidelaps'and 8=inch o.c. atfour (41 equally spaced'staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure = -75 psf:
Deck: (tAin. f5/32-inch'plj wood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment)
Fasteners: Dekfast #14 with Dekfa'st Hex plates, CMG #14 HD with CMG 3" Galvalume Steel Plates; OMG Roofgrip #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 10=inch o.c.' at'the 4=inch wide side'laps and 10=inch o.c. at"three (3) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex 56 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#20 Maximum .Design 'Pressure =-90,psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 6-inch o.c., at the 2-inch wide side laps and 6-inch o.c, at two (2) equally spaced staggered center rows.
lfiderlayment: Elastoflex G TU.or. Elastoflex S6 G, applied•in:fuR.tnappirig,of,hpt asphalt or. Polyflex G;•torch-applied.
#21 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction,
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: 0MG:#1'2' Stan d# dKRoofgdp,or0MG'#f.4HeawDuty'witha MGVr oun6,Wletz)_Plates or,�OFUIG:Flat-Bottoft1',4;etal.,
Plates
Spacing: 6-inch o.c. at the flinch wide side laps and-6-inch ti.c. at three (3)'equally spaced staggered center rows.
Underlayment: Elastoflex G TU. or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G; torch -applied,
##22 Maximum Design Pressure = -90 psf:
Deck: Niin.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trufast #12 DP or Trufast #14 HD with Trufast 3" Metal Insulation Plates
Spadng: 64nch o.c. at the 44 aeh wide side iaps and 64och o.c. at three d3)*Wa+ay spaced staggered oenterTows.
';Uh leriayme6t: i=ias�oflexiG fi1U,or`Ijas%flex,54�G, appiied'�n �dii'tnopping of ho% aspltelt.
#23 Maximum Design Pressure = -90 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Polyglass G2 Base or Polyglass APP Base (requires use of torch -applied underlayment).
Fasteners: Dekfast #14 with.Dekfast. Hex: pl.atesi� OM.G.:#14... HA with OM63" Galvalume $tee( Pl tes;,OMG. Roofgrip. #14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 9-inch o.c. at the 4-inch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied.. oR Polµftfex G, torch -
applied.
Exterior Research and Design, LLC. Evaluation Report P12060.02.09-1123
Certificate ofAutharizotion #9503 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments; 1570) 384-1230 Revision 23. 09/14/2017
;R ge9cif14
",j TRINIT Y I ERD
#24 Maximum Design Pressure = -97.5 psf: }
fl=rac: �Vlzn. 39/32: ric i,plywoatJ eo:rr+eet..pr jecx requirements to:saatidaetion of AuthoritV.,Having'Jurisdiction.
Base Sheet: 'Elastobase orWitile-'Wide Tull Base 1poly-ilm top surface)
Fasteners: 11 ga. x 1.25-inch x 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 4-inch o.c. at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered center rows.
.U,nderlayment:.PglystiGk TU P, Polystick TU Plus, Polystick TU:Majc,;Pety.flex,SAP, Polyflex.-SAP FR, Mule-Hide-SA-APP Ca,p Sheet -and
Mule -Hide SA-APP.Cap-Sheet .(FR), self -adhered.
#25 Maximum Design Pressure = -105 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXXCap Fasteners
Spacing: 6-inch o.c. at the 2-inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows.
Undeday'ment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Poiyflex G, torch -applied.
#26 Maximum Design Pressure = -120 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction 'of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or torch -applied cap or, poly-fiIm.surface for torch -applied cap)
Fasteners: OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: 6-inch D.C. at the 44nch wide side laps and,6-ino.o.c. atfive..(S).equaijy spaced staggered ce tex fovrs:
U,ndlerlayment: Elastoflex G TU or.Elastoflex S6,G, appkd in full rmopping oaf hot •wait air Pc4yfiex�G, torch-aptpf ed.
#27 Maximum Design Pressure = -120 psf
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase:Isanded.top�surface)
.Fasteners: Trufast.#12 DP or Trufast #14 HD -with Trufast 3" Metal -insulation -Plates
Spacing: 6-inch o.c. at the 4-inch wide side laps and 6-inch o.c. at five (5) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam-on•tile systems carry. a Maximum
Design Pressure of -45 psf.
5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed
that required under FRSA/TRI April 2012•(04-12), Appendix A, Table 1A.
Afternatibely, the maxiimum, design' pressure- for the selected assembly shall` meet or exceed the Zone 1 design
pressure determined' in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the,elevate.d,pressure criteria. Commonly used methods are
ANSI/SPRI,WD1, FM Loss Prevention Data Sheet 1-29 and, Roofing -Application Standard RAS 117. Assemblies marked
Wftb?.0. psiefask* iww ,the Am0taVQn4 set forth in Section 2.2.10.1 of.,001oss-Pmventitsn.-Data She at 1-29 J(1anua7y
2fl16�j for Zone 2/3 enfiancements.
5.7 Exposure limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polyglass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after installation.
Polystick MTS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastoflex G TU shall not be left exposed for longer than
180-days after installation.
P,oVfex SAP, of SAID 5% or d ijk-kidle SA -API Cap Sheet or SA-APP Cap Sheet (FRY does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have aq.exposure. limitation, unless the.
prepared roof"covering is to be adhesive -set tile (Elastoflex S6 G or Polyflex G. only),. in. which. case the maximum.
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between,,purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
Exterior Research and Design, EEC• Eva luation.Report P12060.02.09-R23
Certificate of Authorization #9503 6' EDITION 12017) FBC NON-HVHZ EVALUATION FL5259-R27
Polyglass Roof Underlayments.,1570).384-1230 .Revision.23: D9114/2017
Page 10 of 14
TRINITY J ER®
5.9 Tile Slippase'Limitations.(TAS 103 per FRSA/TRLADril2012_(0442)):
When loading'roof tiles on -the underIOymedt`in direct -deck -tile assel'nbiies, the maximum roof slope 'shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
- . TABLE 2: TILE SLIPPAGE"LIMITATIONS,FOft DIRER -DECK TILE INSTALLATIONS
. mde IaVment
TilePr+ofile
gii vvwthod
lJiatitititiin Sbpe
Elastoflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack (6 over 2)
6:12
Elastoflex S6 G or S6 G FR
Flat or Lugged
6-4•ile stack (4 over'2).
4:12-
Polystick MTS
F.lat.or- Lugged,
Prohibited.vaithout�battens >
Rt A
Polystick Tile Pro
Flat or Lugged
6-tile stack (4 over 2)
7:12
PolystickTU Max
Flat
6-tire stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:12
Ct2gg2r1
f�frile<sfack`
5:f2
Polystick TU P
Flat
6-tile stack (4 over 2)
6:12
Lugged
6-tile stack (4 over 2)
4:12
Polystick-TUU-Plus
Flat or Lugged
6 tilestack.(4over.2)
7:12
Flat"or;kugged
107tile•stack
'6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SAP FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
`G. ' ` NSTALli4fil00-
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking. panels, and' check for protruding nail heads: Sweep the substrate thoroughly to remove
any dust and`de6ris prior to application, and prime the substrate (if applicable).
6.9' c'lasfiibdse, Elastobase h`or'Mute-Hd Naii Base:
6:3.1 Igoe -Tile Applications;
Shaft~ be Fnstaffed in compf ance wrtfi the codified''requirements for ASTM D226, Type II underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nail Base may be covered with a layer of Polystick, Polyflex SAP, Polyflex SA
-P-TR, -Mule-HideSA-APP Cap Sheet or SA-APP -Cap Sheet -(FR), self -adhered, Elastoflex ,G TU, Elastoflex S6 G or
�Sastdiiex �6' `�R in 'not aspf�ait or°Palyflex-,G-or'f�oioex G A,,torch applied. "Roof cover Timltafions are those are
those associated with the top -layer underlayment, as set forth in Table 1.
6.3.2 Tile Applications:
iE4astolsase,: Elastobase P,or Mule-i4idertSaHaase�are,;ljmited,to'use;as,armechen'ica1ly a@Mched base sheet=i;p the `Iwo
Ply System"' from FRSA/TRI April 2012 (04-12). Reference is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
ze"cate'o}Authdrization #gso3 Sf" EDITION 120111TSC NON=HVHZ EVALUATION F15259-1327
Polygims Roof Underiayments; (570) 384-1230 Revision 23: 09/14/2017
Page 11 of 14
RIf ERD
1
6 4 Polystick 11AT5, IR Xe, TU P,'TU Plus; TU Max, Duai Pro, Tile•Pro or (VIU X or'Polyflex SAP; Polyflex SAP FRrMulesHide"
SA-APP Cap Sheet or Mule tilde SA=APP Cap Sheet.(FR)
6.4.1 tha)i be- imialled "in compliance miith the„codified requireIments for ASTM D1970 underlayMent In F8C Table 1507.1.1
for the type of prepared roof covering to be installed.
6.4.2 Direct -to -Deck with Mechanically Fastened Roof Covers:
All•self-adhering materials;°%vith..the..exceptiob,of Polystick TU Plus, Pofyffiex'SAP-or SAP FR and Mule-`l"iide SA-40
Cap Sheet or SA=APP Cap Sheet -(FR) -should -be back=nailed in selvage edge seam in accordance with Polyglass / Mule -
Hide Back Nailing Guide. Nails shall be corrosion resistant, 11 gauge ring -shank type with aminimum 1-inch diameter
metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plus should be back -nailed
using, the above noted fasteners.and. spacing, in area marked "nail_arek afea;pa a,clapyaj on the face of,Rgea pFa e.
The heard laps membrane Is tor &ti 6etlie air'ea being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller,tQ=ensure_ full contact. an4 adhesiuri'y
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric).
View of-Ovelap Seam of -Dual -Pro avid Tile Pro
All over -fabric and over -granule end -laps shall have a 6-inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PGS00 Modified Cement applied in between the application of the lap.
PolystickTU Plus, 9UAL I?T!0 aA .Tile. Piro ntaytiRptbe.use0,iAan.,y-expased,.apsrtj�h-assc,�!€ets;>expas��l:vailQl�SF
or exposed roof to wall details
Repair of Polystick membranes is to be accomplished by applying Polyplus 50 Premium.Modified.Wet/Dry. Cement or
Polyglass PG500 Modified Cement to the area in need of repair,. followed by a minimum 6 x 6 inch patch of the
Polystick: material of like *lhd.. set 4hd, hand. rolled in place over- the..,Fepafr area. Patch laps, if needed,' shall be
installed in a water shedding manner.
All Polystick membranes shall be installed to ensure full contact with approved substrates. • Polyglass requires a
minimum of 40-lb weighted -roller or, on steep slopes, use of a stiff broom with approximately 40-lbs of load applied
for # e - ei4l fi��Mbrame. Ada ppllers are repo fe for �re41.i . ,vtpatct�es, maps k m±tn. 3,8;Ib T?olte�r) �r.smafl areas _of the
roof that are not accessible to a iarge roller or broom.
6.4.3 Tile Applications (not allowed for Polystick Dual Pro, li? Xe or Polystick m"—
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1,herein, using the instructions
noted above as a guideline.
For mechanically fastened the roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2022 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
For, nail`-on-liife,sysbBms oven €lafVstick iVTTS' battens arerequlred�for loading / staging `of;'thetile.
6.4.4 Two (2) Ply Underlavment Systems:
Polystick MTS followed by Polystick MTS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex SAP is allowable for use
under mechanically attached prepared roof systems. Limits of use are those associated with the top -layer material.
This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Exterior Research and Design, LLC. Evaluation Reprt 912M0.02AM-R23
Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION FL5259-1127
Polyglass Roof Underlayments;1570) 384-1230 RevWon 23: 09/1412017
Page 12 of 24
r -IN 'C
� T RINITY ER®
6 5'flastoflex:G:TUflast®flex'S6G:orElastofleic'S6:G'FR .. °''
6:5.1 `Elastoflex GTU; Elastoflex S6 G or Elastoflex S6 G FR shall be installed in compliahce'with current Polyglass published
installation requirements. For use in the applications;
✓ Elastoflex G TU_ is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply Sys<errt"f rm1F135AftTR1Apol 213 Z*(04,AB)_beneath;meehan:icallj.fattened file rodf systerrisr r ,he "Ot:As;{akialt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M). in the "Single Ply
System" from FRSA/.TRI April, 2012_(0414_ eneath- mechanically, fastened.tile.'roof:systerns,or. the Hot.Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Elastoflex S6 G FR is for use as an alternate to "Mineral Surface Roil Roofing" (ASTWI D6380, Class Wii) in the "Single
P. ht Systi&ff• fi~o Fl / 111 l i$ i#'.1I12 (04-12j 6e6ea6M&Vt3»iealVj faisterfed fife Voof sysi Ems or the Pfof asp- "
applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
6.5.2 For hot -asphalt -applications, Elastoflex G TU, Elastoflex 56 G, or Elastoflex S6G FR-shall be fully asphalt -applied to the
substrates :nb.ied in Section 5.6. 'Side •laps::shali't a Miriimurri �Vlnch and end=laps minimum 6-inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge,
6.6.1 Polyflex G or Polyflex G FR shall be installed in compliance with current Polyglass.published installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an -alternate -to the Heat Applied -"Cap Sheet" in-the""Two Ply'System" from FRSA/TRI-April-
2012'(04-12) beneath'mechanitaIli fastened'oradhered tile- roof systems ("8ase Sheet Lirniteti''per-5.6.3):
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI
April 2012 (04-12) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
6.1y.2 RoiyPlex. G or Fo"; 0FR shaf"'be fui(y.torcft-sp fired' -to L.ti substrates rr terSide, tape slialt; e. .
minimum 3-inch and end -laps minimum 6-inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge.
6.7 Tile Staking:
6.7.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to
Table 2 herein, and Polyglass published requirements for tile staging.
6.7.2 Battens and/or CGunt.er�battens,-,as repaired ,by the the manufacturer and FRSA/ RI April 2012 (04-1.2j must be used
an all pro f slopes,-gtiater'than `7:12. ;Precautions should "be taken as -needed, such ,as'tfie use of battens or na'il-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after installation of self -adhering membranes and before loading of
roofing tiles is -forty-eight (48) hours.
Exterior Research and Design, I.I.C. Evaluation Report P12060.02.09-R23
'Certificate of Authorization #9503 .OrN EDITION (2017)'FSC NON-NVHZEVALUATION FL5259_R27
Polyglass Roof Underlayments; (570) 384-1230 Revision 23: 09/14/2017
Page 13 of-14
7. BUILDING PERMIT REQUIREMENTS:
As,required,by the Building Official or Authority Having Jurisdiction iri order.to properly.evaluate the installation of this product.
S. MANUFACTURING PLANTS:
Contact the noted QA agency for information on product locations covered:f.Or. FJ.Lr-. 62f30-3. QA requirements. The following
plants have qualified products under their respective physical properties specifications.
9.
apecificatlbh
.Products - r E
Fernley, NV, Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick MU-X
Hazleton, PA
M'-D 13-b004
Elastoflex G TU
NaZ ":PA,?,:W_.};aveu. �
ASTM D1970
Polystick IR-Xe
ASTM A.19afl&:TAS3fl3
4?oi��st+ckT-P;tr�s
ASTWI D1970 & TAS 103
Mystick TU Max
Tuscaloosa, AL
ASTM D4601, Type II,
Polyglass G2 Base
Winter Haven; FL
ASTM D226 (physicals)
Elastobase,-Elastobase P
A.STM.D6509
;Polyglass APP Base
TAS.103
Polystick MTS
ASTM D1970 & TAS 103
Polystick TU P
FRSA/TRI April 2012
Polyflex SAP, Polyflex SA P FR
ASTM D1970
Polystick Dual Pro
ASTii lst519/fJ> �AS� 03;r
l?ojjk-rife•Paa
ASTM D6164
Elastoflex S6, Elastoflex S6 G FR
ASTM. D6222
Polyflex G, Polyflex G FR
t{UALTTY ASSURANCE tNTITY:
UL, LLC=QUA9625; (314),578=3406; k.chancellor@us.ul.com
END OF EVALUATION REPORT -