HomeMy WebLinkAboutALUMINUM SCREEN DESIGNALUMINUM SCREEN DESIGN
PANNELS ARE ATTACHED TO TOP PLA
O WITH 4 910 4" PER PANEL
6" FROM ENDS 24" O.C.
DOUBLE 2X4 HEADER NAILED
O TOGETHER WITH 16P NAILS
6" FROM EDGE 12" O.C.
2X4 16" O.C. ATTACHED TOP &
O BOTTOM WITH 2 16P NAILS &
SIMPSON H25 STRAPS
D P.T. 2X4 IS ATTACHED TO WOOD FLOO
W/ 1/4" X 4" LAG BOLTS 24" O.C.
%I
7/16" OSB ZkAPOR BARRIER
O ATTACHEMWITH IOD NAILS 4"
OUT FIELn 6" IN FIELD
SIDING I ACHED WITH
FO 1 LB 12 G E SIDING NAILS
EVERY 1
ALUMINUMSCREENDESIGN.COM
ALUNQNUNISCREENDESIGN
@YAHOO.COM
PHONE: 407-734-1470
FAX: 407-734-1790
N
DESIGN STATEMENT
ALL TAPCONS SHALL PROVIDE MINIMUM OF 1 1/8" CONCRETE EMBEDMENT DEPTH
THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2017 (6TH EDITION)
FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH
(FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1.
CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION
CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS
HEADERS
DOOR FRAME SUCURED WITH
48 OR BIGGER 3" WOOD SCREWS
OR TAPCONS I/4' X
P.T. 2X4 IS
ATTACHED TO WOOD FLOOR
W/ 1/4" X 4" LAG BOLTS 24' O.C.
;UCURED WITH
/OOD SCREWS
(3"
O.C.
ED TO WOOD FLOOR
ILTS24" O.C.
4401 NELAND, ROA
D
AD
,SUITE A6
-ORfANDO, FL 3�811
E. # 47509