Loading...
HomeMy WebLinkAboutPROJECT INFORMATION WINDOW REPLACEMENTtgc)-a - O-ZZ-Is RECEIVED 3 1 L MAY"'0 9,0118 C St Lucie OUntY --rPlan Types: ST. Lucie Courity, Permitting I In tree Room/Sun Rooq(I=FHIln) Ftpoal . Screa-291caga tow * nd adual Wind Speed) Screem— %Des4ped fin eta pa Port Flpatio Cover ect.Address: ,�;Address-. IfT, Rexct-a Code.: -73 <49 4 C *Choose 0 11176d: Ery; op ne.0 ma Elmo up EJE,�. File _N6 of C. '(For fed i c, option go to —:ee-ades iga:fgo u, and. provide Fed�x, a-ccourA. 9) Pay in a n t: X C- h 2 aff � k Credit Ca r df (For Credit ,:Q ard option.go to wxv,v.allmlinLin-iscreendeal�o--n.con-i to pay by credit card) EngimehOg prepared by: Englnoqr. Michaef -a hompaon,, M9c, P.E..(P.E. A 447-NDAV) 4401. Vinela . nd Road- Sujte A6 Odando, FL 32811 Office:407-734-1470 0,60:407-7212292 Website: a h i �n, gung, - S 0,1 G, 191 CjFli CA-I*0P3a PC Screen Room/SupCH Rooff4l n,:. . Insulated PaMIROOR 6 A F'14th t1all: uuer F�Frascla MR-IockWadg co-F.Ventional -.21 Uprights X Top Plate X Klilck Plate ]'Dome, CjGaible n.Mansard []Shed/SIOP GLItter []Fascia n a I o VI -A -a II Elcogn Beams x U pr 1 wh a, X pudill Klc* *L,%-,, Pleggy Car Port: DI I ns ul a - Ws' EIr.EPanFRloumdo-A-,OU'Va11 .Cc nve-AI-0nal tAka-I11S as gut Beams X Post:x. pa`ora `nsulgted P an OR"a - F ElAth Wall O.Gufter ElPascia FIBlock Walb F IC-nonventionalwMi-I'l Iseamsm x post x Concrete: -171 OF!!& E,]5tibbon Footer X Elpavers [:j6" Thickened. Edge and geOeral notes:zihd:design sta -nosM , tip' e contracior mall uffize the' Move stingen.t'.dimensions apd'member f.-Izes nr'.Cr to qrd6'rH--q' MillakEM9 5, f ti-bridadon, e#06r construcDont between the plans and general rotes and desigmstandar.d. rs C- $fIl hae to s n, e— , M. I,!'C =j Orlando, FL 3-93i I 4401 VvIeland Road rMV; (CA#30930-1-Ph, 407-43441470IFax 4,617-734-1790 Design Standards The following are general design standards. More stringent design standards may be noted on tho plans.ji ` r General Requirements: - Reproductions of contract drawings by contractor in lieu of preparation of shop drawings signifies d6cept4nce of inf6.rmat n - shown as correct and obligates himself to any expense, real or implied, arising from their use. A chance t6 the S+im& drawings due to the acceptance of alternates and/or substitutes is the responsibility of the contractor -and must be submitted to the engineer for approval. The general contractor and each subcontractor shall verify all existing conditions prior to the start of any work. All inconsistencies shall be reported to the designer and/or structural engineer, if needed. Should contractor construct the premises in a fashion not consistent with the plans prepared by the designer and/or structural engineer, or in any fashion, change the plans and drawing without the review and approval from the designer and/or structural engineer. Then designer and/or structural engineer shall bear no responsibility or liability for the construction of premises and accuracy of the drawings. Design Code: Florida Building Code 2017 The Aluminum Association, latest edition ASCE 7-10 Galvanized Bolts: All bolts shall be galvanized be ASTM A572, grade 50 threaded round stock with Design Loads: Ultimate Wind: 165 mph at 3 second gust (30 psf minimum) Pursuant to Chapter 1609 LL (—Table 1607; WL- Section 1609) Risk Category I (Table 1604.5) Exposure Category: "C" (FBC 1609.4.3 & ASCE 7-10, Section 26.7.2) Deck Live Load: 60 psf Dead Load: 10 psf Roof Live Load: 20 psf a minimum yield stress of 50,000 psi. Components and cladding, design wind pressures + 60psf/-60psf Timber: Design in accordance with the National Design specification for wood construction, with loading in accordance with the Florida Building Code. All graded structural lumber shall be pressure treated and meet the following minimum requirements: Minimum bending stress =1250 psi (No. 1 Dense So. Pine) Young Modulus =1600 ksi Maximum of 15% moisture content Contractor may use Southern Yellow Pine No. 2 or U.O.N. Lumber sizes shown are nominal sizes. Lumber shall be furnished in finished sizes meeting the requirement of the American Softwood Lumber Standard. Structural Aluminum: Conform to latest edition of Aluminum Association of Florida standard practice for aluminum design. All aluminum shall be 6061-T6 (E= 10,000 ksi; Fy = 35 ksi) Concrete Conform to ACI 318, latest edition and ACI 301 Compressive Ultimate Strength (Minimum at 28 days) shall be 3,000 psi Exposed chamfer edges shall be 3/4" Reinforcing Steel: Conform to ACI 318 and 315, Latest edition All reinforcement steel shall be ASTM A615 Grade 60. Min footing cover 3" Smooth dowels & ties shall be ASTM A185 Structural Steel: Conform to latest edition of AISC "Specification for structural steel building" and AISC "Code of standard practice for steel buildings and bridges". All structural steel shall be ASTM A36, (E= 29,000 ksi; Fy = 36 ksi) Splicing prohibited without prior approval as to location and type. Burning of holes in steel members is prohibited. Any member with burned holes must be replaced. Welding: Conformed to "code for welding in building construction" by the American Welding Society, latest edition. Steel Weld IAW AWS D1.1 (latest edition) —E70XX electrodes Aluminum Weld IAW AWS D1.2 (lasts edition) -Filler Alloy 5356 or equal. Connection welds to be sized for forces and reactions indicated. All steel welds shall be E70XX low hydrogen, 250 degrees min. Welds shall be full penetration welds at all points of contact. The contractor shall provide protection to wood and wood based products against decay. Framing members less than 8 inches and sheathing/sliding 6" above grade shall comply with FBC R317. ' 4M.. f° - i�K: Leo f O ' In the event of a conflict in member sizes shown 6n eneral notes, thetontfac'01 contractoWmust r' the plans and the g utilize the more stringent member size, require. nth. y f R In the event of a conflict in member sizes shown on the plans and the general notes, the contractor must utilize the more stringent member size requirements. a ., x ;V uo 4 a ' iJ