HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFFlorida., Building Code Orlin =
ZIBY
St Lude COMAY
ProfessionalBusiness & e
BCIS Home ; Log In I User Registration Hot Topla ; .Submit Surcharge Slats &Facts
Or*
Product Approval
USER: Public User
Page 1 of 4
. III
h g� /a6bruam nePRU-01 Buel coxU¢toaPR
Product Approval MPnu > Plgduct or Application Search > Aoollcation List > Application Detail
FL # FL11560-113
Application Type Revision
Code Version 2017 RECEIVED
Application Status Approved
Comments FEB 13 2018
Archlved ST. Lucie County, Permitting
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email' 3rd Street, Suite 200
THESE PLANS AND ALL PROPOS IMY 40202
ARE SUBJECT TO ANY CORRECTWP855-4300
REQUIRED BY FIELD INBPECTOFMfPHf r@metaisales.us.com
MAY BE NECESSARY IN ORDER TO
Authorized SignatLwOMPLY WITH ALL APPLICABLEAPAIRarmer f yea _ a 3
dstermer@metalsales.l�;;6omC COLT?tTTY BU-II.. tY n:zTISI�JiY
Technical Representative 1 E-VIUEWE]D FOR = LIANCE
Address/Phone/Email ]I;EYIF 4S+ BY t
I�A�rE. 4 , 1`
PLANS, ANM PEEL' UT nIUST BE KEPT ON JOB
Quality Assurance Representative �n NO 7r;�;S��ECTIO?1 WILL BE bIADE.
Address/PIONCIALIED FASTENERS OR ATTACHMENTS
Category ARE THE RESPONSIBILITY OF THERoofing
Subcategory CONTRACTOR OF RECORD Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
0 Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 12/27/2026
Validated By Yoosef Lavi, P.E.
R Validation Checklist - Hardcopy Received
Certificate of Independence FL11560 R3 COI CertificateIndeoendence.odf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
2012
2006
File Copy
https:llwww.floridabuilding.orglprlpr app_dtl.aspx?param=wGEVXQwtDqudhLg8eDpZl... 1/24/2018
Florida Building Code Onlir
Product Approval Method Method 1 Option D
Date Submitted
09/09/2017
Date Validated
09/14/2017
Date Pending FBC Approval
09/15/2017
Date Approved
12/12/2017
FL # Model, Number or Name
11560.1 Aluminum 5V-Crimp
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-161.5
Other: Uplift load of 30 psf at fastener spacing of 36" o.c.
and 161.5 psf at fastener spacing of 6" o.c.
Page 2 of 4
Description
24" wide, nom 0.032" thick aluminum through fastened roof
panel over min 15/32" thick plywood deck or 7/16" thick
OSB with fasteners through panel rib.
Installation Instructions
FL11560 R3 II EvaluationRenortC2181 1 odf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R3 AE Eva luationReportC2181 l.pdf
Created by Independent Third Party: Yes
11560.2 Aluminum Image II 16" wide, nom 0.032" thick aluminum concealed fastener
roof panel over min 15/32" thick plywood deck or 7/16"
thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11560 R3 II EvaluationReportC2181 2 pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-107.4 Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 24" o.c. FL11560 R3 AE EvaluationReDortC2181 2 pdf
and 107.4 psf at fastener spacing of 6" o.c. Created by Independent Third Party: Yes
11560.3
Aluminum Image 1I
16" wide, nom 0.032" thick fastener roof panel over min
19/32" thick plywood deck
Limits of Use:
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II EvaluationReportC2181 3.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-195.0
Evaluation Reports
Other: Uplift load of 22.5 psf at fastener spacing of 24"
FL11560 R3 AE EvaluationReaortC2181 3.vdf
o.c., 104.7 psf at fastener spacing of 6" o.c—and 195.0 psf
Created by Independent Third Party: Yes
at fastener spacing of 6" o.c. with support strap.
11560:4' c
Image II w
2
Min: 6 ga., max. 16" wide standing.seam roof panei..ove�i
.min._15/32";thick.piywood deck:
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II Eva luationReoortC2181 4.1)df
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Design Pressure: +N/A/-84.25
Created by Independent Third Party: Yes
Evaluation Reports'
Other: Uplift load of 84.25 psf at fastener spacing of 24"
FL11560 R3 AE EvaluationReoortC2181 4.pdf
O.C.
Created by Independent Third Party: Yes
11560.5
Image II
Min. 26 ga., max. 16" wide standing seam roof panel over
min. 19/32" thick plywood deck
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Installation Instructions
FL11560 R3 II EvaluationReportC2181 5 odf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Design Pressure: +N/A/-139.1
Created by Independent Third Party: Yes
Evaluation Reports.
Other: Uplift load of 84.3 psf @ fastener spacing of 244",
102.7 psf @ fastener spacing of 6" and 139.1 psf @ fastener
FL11560 R3 AE EvaluationReoortC2181 5 odf
Created by Independent Third Party: Yes
spacing of 6" with 3/8" bead adhesive in sidelap
11560.6
Magna-Loc
Min. 24 ga., 16" wide standing seam roof panel over
plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II Eva luationReportC2181 6.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Design Pressure: +N/A/-166.0
Created by Independent Third Party: Yes
Evaluation Reports
Other: Uplift load of 95.2 psf @ MC clip spacing of 30" o.c.,
101.0 psf @ MC clip spacing of 15" o.c., 123.5 psf @ MC clip
FL11560 R3 AE Eva] uationReoortC2181 6.Ddf
Created by Independent Third Party: Yes
spacing of 8" o.c. and 166 psf @ MPW clip spacing of 12"
O.C.
htlps:l/www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwd)qudhLg8eDpZ1... 1/24/2018
Florida Building Code Onlin= Page 3 of 4
11560.7 1Magna-Loc
Min. 24 ga., 16" wide standing seam roof panel over steel
deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II Eva IuationReportC2181 7.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-168.5
Evaluation Reports
Other: Uplift load of 59.7 psf @ MC clip spacing of 36" o.c.
and 168.5 psf @ MPW clip spacing of 12" o.c.
FL11560 R3 AE Eva IuationReoortC2181 7.odf
Created by Independent Third Party: Yes
11560.8
Stile
Min. 26 ga., 39.4" wide through fastened roof panel over
min. 15/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II EvaluationReportC2181 8.pdf
Approved for use outside HVHZ: Yes
Verified By: Baia Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-102.7
Evaluation Reports
Other: Uplift load of 85.8 psf at fastener spacing of 24" o.c.
FL11560 R3 AE EvaluationReportC2181 S.odf
and 102.7 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
11560.9 I Stile I min. 19/32" thick p wide
through fastened roof panel over deck
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL11560 113' )I Eva luationReoortC2181 9.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-149.6 Evaluation Reports
Other: Uplift load of 50.4 psf at fastener spacing of 36" FL11560 R3 AE EvalvitionRenortC2181 9.odf
o.c., 106.8 psf at fastener spacing of 24" o.c. and 149.6 psf Created by Independent Third Party: Yes
at fastener spacing of 12" o.c.
11560.10
Vertical Seam
Min 24 ga., max. 16" wide standing seam roof panel over
min. 15/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II EvaluationReportC2181 10.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.3
Evaluation Reports
Other: Uplift load of 30.0 psf at clip spacing of 48" o.c.,
FL11560 R3 AE EvaluationReportC2181 10.odF
73.0 psf at clip spacing of 24" o.c. and 114.3 psf at clip
Created by Independent Third Party: Yes
spacing of 8" o.c.
11560.11
Vertical Seam
Min 24 ga., max. 18" wide standing seam roof panel over
min. 15/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II EvaluationReportC2181 11.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-105
Evaluation Reports
Other: Uplift load of 30.0 psf at clip spacing of 48" o.c.,
FL11560 R3 AE EvaluationReportC2181 11.ndf
82.5 psf at clip spacing of 12" o.c. and 105.0 psf at clip
Created by Independent Third Party: Yes
spacing of 12" o.c, with sldelap adhesive.
11560.12
Vertical Seam
Min. 26 ga., 16" wide standing seam roof panel over min.
15/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II EvaluationReportC2181 12.odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-81.3
Evaluation Reports
Other: Uplift load of 30.0 psf at clip spacing of 48" o.c. and
FL11560 R3 AE EvaluatlonReportC2181 12.odf
81.3 psf at clip spacing of 6" o.c.
Created by Independent Third Party: Yes
11560.13
Vertical Seam
Min 24 ga., max. 16" wide standing seam roof panel over
min. 15/32" thick plywood deck
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11560 R3 II Eva] uationReoortC2181 13.pdf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam P.E. 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-114.25
Evaluation Reports
Other: Uplift load of 22.5 psf at clip spacing of 48" o.c. and
FL11560 R3 AE EvaluationReportC2181 13.pdf
Created by Independent Third Party: Yes
93.5 psf at clip spacing of 12" o.c.
11560.14 I Vertical Seam I Min 24 ga., max. 18" wide standing seam roof panel over
min. 15/32 thick plywood deck
Limits of Use Approved for use in HVHZ: No I FL 1560' R3 s IIEvatru at onReportC2181 14.pdf
https://Www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDqudhLg8CDDZl... 1 /24/2018
Florida Building Code Onln)° Page 4 of 4
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-114.25
Other: Uplift load of 22.5 psf at clip spacing of 48" o.c. and
86.0 psf at clip spacing of 12" o.c.
Verified By: Bala Sockalingam P.E. 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL11560 R3 AE Evaluat9onReportC2181 14.0f
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The. State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida, ::'Privacy Statement:: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records. request, do not send
electronic mail tothis entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 45S.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an emall address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F,S., please click Here .
Product Approval Accepts:
[low ® eCtad,
Credit Card
Safe
https://www.floridabuilding.org/`D 1/24/2018
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
`26 GA. IMAGE H PANEL'
FLORIDA BUILDING CODE 6TH EDITION (2017)
FLORIDA PRODUCT APPROVAL
FL 11560.4-R3
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4200
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
Evaluation Report (3 Pages including cover'
Installation Details (1 Page)
Report No. C2181-4
Date: 9.8.2017
' e®►►aaa€nsce�
9tvve SOCKAkI, ep
b ••� P
No 62240
N
C
as • • (— N
®p ' STATE OF
IV A ao�
FL 11560.4-R3
C2181-4
9.8.2017
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: Image 11
Panel Description: Max. 16" wide coverage with 1" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A.792) or painted steel (ASTM A755).
Deck Description: Min. 15/32" thick plywood or min. %" thick wood plank (min SG of
0.42) for new and existing constructions. Designed and installed as
per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c.
(Factor of Safety = 2)
Fastener Pattern: #10-12 pancake head screws along panel seam. Fastener shall be of
sufficient length to penetrate through the deck a minimum of
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or -ASCE 7-10 using allowable stress
design. The maximum fastener spacing listed herein shall not be
exceeded. This evaluation report- is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
NEW UNOERLAYMENT
SEE DETAIL 1 �EXISTING SHINGLES MAX. 16"
ROOF PANEL �
(OPTIONAL)
n \ li
u /
EXISTING UNDERLAYMENT MINIMUM ATTACHMENT:
(OPTIONAL) 88 x 2.5" LONG RING SHANK NAIL
MIN. 2X_ WOOD RAFTER/JOIST/ OR #8 x 2" LONG WOOD SCREWS
TRUSS AT MAX. 24" O.C. SPACED ® 6" D.C. IN THE FIELD
MIN 26 GA.
NEW UNDERLAYMENT
EXISTING SHINGLES
(OPTIONAL)
EXISTING UNDERLAYMENT
(OPTIONAL)
DETAIL 1
& ® 4" O.C. AT PLYWOOD EDGES
TYPICAL PANEL INSTALLATION X-SECTION
#10 PANCAKE SCREWS
PANEL FASTENER
SPACING PER ALLOWABLE
PRESSURE TABLE.
15/32" THICK (MIN.)
ALLOWABLE UPLIFT PRESSURE
FASTENER
PRESSURE
SPACING
(PSF)
(IN)
24
84.25
GENERAL NOTES:
PLYWOOD 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
15/32- THICK (MIN.) FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS ARE SHALL BE MIN. 26 GA. MAX. EFFECTIVE COVERING WIDTH OF
PANEL - 16".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL
6. RAFTERS/JOISTS/TRUSSESMUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
U N
? CD
Np0
clJ
vn
U �
[aiYI
� oh
c:4 0
M� I
SN
NN
y0
2181—
PAGE Ni
1 OF