Loading...
HomeMy WebLinkAboutLETTER - ENGINEERINGSCOTT PL SANDERS P.C. ri_ RR; NO-64761 a C sr,T3r �F„ f,. 772.774 9086 S.SAN r) e[ts(,-t"soU'rH EASTIIUI SDI NGtNG i N CERS.COM WW.SOUTIIEnS-rrun.oINGt.',IC;INi-,rRS.CaM RE: 133 Nettles Blvd Jensen Beach, FI 34957 Permit Number: 1802-0291 ,SCANNED BY at Lucie Coll* 4-6-18 1. Comment: ENGINEER TO SHOW THE 'l O"I AL SQUARE FOOTAGE OF ALL ENCLOSED AREAS ON PLANS AND SHOW THE CALCULATIONS FOR COMPLIANCE OF THE NET AREA OF THE ENGINEERED FLOOD OPENINGS Response #1: See Item 1 on sheet 2 revised 3-22-18 2. Comment: WE WILL REQUIRE A FINAL FLOOD CERTIFICATION FROM YOUR SURVEYOR Response #2: Home owner to provide 3. Comment: SHOW A STRAPPING AND FASTENER DETAIL ON PLANS FOR THE CONNECTION OF THE P.T. SKIRT STUDS TO THE BASE AND UPPER PLATES PER FBCR 322.1.8 [ FLOOD RESISTANT MATERIALS Response #3: See Item 3 and 5 on sheet 2 revised 3-22-18 4. Comment: THE 518" SKIRT CDX SUB SHEATHING MUST BE WATER RESISTANT MATERIAL AND DESIGN PROFESSIONAL TO SPECIFY THE ATTACHMENTS PER FBCR 322.1.8 * NOT PER N.O.A. Response #4: See Item 2 on sheet 2 revised 3-22-18 5. Comment: ENGINEER TO CHECK CODE SECTION R322.3.4 FOR PARTITIONS DESIGNED TO BREAK AWAY WITHOUT CAUSING COLLAPSE TO THE ELEVATED PORTION OF THE BUILDING Response #1: See Item 1 and 2 on sheet 2 revised 3-22-18 6. Comment: SHOW THE REQUIRED UNDER FLOOR ACCESS REQUIREMENTS ON PLANS PER FBCR 408.4 Response #1: See Item 1 and 5 on sheet 2 revised 3-22-18 7. Comment: SHOW ALL STAIRWAY DETAILS ON PLANS * FREE STANDING UNIT. LANDING ATTACHMENT DETAILS TO ALL UPRIGHTS, TYPE OF FASTENER HOLDING THE POSTS TO THE LANDING, STAIRS AND BOTTOM ATTACHMENTS Response #1: See updated sheet 3 _Revised 3-22-18 Scott R. Sanders. P.E. Southeast Building Engineers. LLG