HomeMy WebLinkAboutLETTER - ENGINEERINGSCOTT PL SANDERS P.C.
ri_ RR; NO-64761
a C
sr,T3r �F„
f,.
772.774 9086
S.SAN r) e[ts(,-t"soU'rH EASTIIUI SDI NGtNG i N CERS.COM
WW.SOUTIIEnS-rrun.oINGt.',IC;INi-,rRS.CaM
RE: 133 Nettles Blvd Jensen Beach, FI 34957
Permit Number: 1802-0291
,SCANNED
BY
at Lucie Coll*
4-6-18
1. Comment: ENGINEER TO SHOW THE 'l O"I AL SQUARE FOOTAGE OF ALL ENCLOSED
AREAS ON PLANS AND SHOW THE CALCULATIONS FOR COMPLIANCE OF THE NET
AREA OF THE ENGINEERED FLOOD OPENINGS
Response #1: See Item 1 on sheet 2 revised 3-22-18
2. Comment: WE WILL REQUIRE A FINAL FLOOD CERTIFICATION FROM YOUR SURVEYOR
Response #2: Home owner to provide
3. Comment: SHOW A STRAPPING AND FASTENER DETAIL ON PLANS FOR THE
CONNECTION OF THE P.T. SKIRT STUDS TO THE BASE AND UPPER PLATES PER FBCR
322.1.8 [ FLOOD RESISTANT MATERIALS
Response #3: See Item 3 and 5 on sheet 2 revised 3-22-18
4. Comment: THE 518" SKIRT CDX SUB SHEATHING MUST BE WATER RESISTANT MATERIAL
AND DESIGN PROFESSIONAL TO SPECIFY THE ATTACHMENTS PER FBCR 322.1.8 * NOT
PER N.O.A.
Response #4: See Item 2 on sheet 2 revised 3-22-18
5. Comment: ENGINEER TO CHECK CODE SECTION R322.3.4 FOR PARTITIONS DESIGNED
TO BREAK AWAY WITHOUT CAUSING COLLAPSE TO THE ELEVATED PORTION OF THE
BUILDING
Response #1: See Item 1 and 2 on sheet 2 revised 3-22-18
6. Comment: SHOW THE REQUIRED UNDER FLOOR ACCESS REQUIREMENTS ON PLANS
PER FBCR 408.4
Response #1: See Item 1 and 5 on sheet 2 revised 3-22-18
7. Comment: SHOW ALL STAIRWAY DETAILS ON PLANS * FREE STANDING UNIT. LANDING
ATTACHMENT DETAILS TO ALL UPRIGHTS, TYPE OF FASTENER HOLDING THE POSTS
TO THE LANDING, STAIRS AND BOTTOM ATTACHMENTS
Response #1: See updated sheet 3 _Revised 3-22-18
Scott R. Sanders. P.E.
Southeast Building Engineers. LLG