HomeMy WebLinkAboutENERGY EFFICIENCY CODEBY
FORM R405-2017Moot
FLORIDA ENERGY-EF IICIE CY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: DAVID GREEN
Builder Name:
Street: 143 DUSK WAY
City, State, Zip: FT. PIERCE, FL,
Permit Office: ST. LUCIE COUNTY
.
Owner. . ' DAVID GREEN
Permit Number.
Design Location: FL, Fort Pierce
Jurisdiction:
County:: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing Addition
9. Wall Types (468.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 468.00 ftz
3. Number: bf units, if multiple family 1
b. N/A
R= ftz
4. Number of Bedrooms 0
c. N/A
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (320.0 sgft.)
R= ftz
Insulation Area
6. Conditioned floor area above grade (ftz) 320
a. Under Attic (Vented)
b. N/A
R=30.0 320.00 ftz
Conditioned floor area below grade (ftz) 0
c. WA
R= ftz
R= ftz
7. Windows(83.3 sgft.) Description Area
a. U-Factor.
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
R ftz
6 128
Dbl, U=0.65 43.33 ftz
SHGC: SHGC=0.30
b. U-Factor. Dbl, U=0.65 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
39.0 SEER:16.00
c. U-Factor: - WA ftz
SHGC:
d. U-Factor. N/A ft2
13. Heating systems
kBtu/hr Efficiency
SHGC:
a. Electric Strip Heat
17.4 COP:1.00
Area Weighted Average Overhang Depth: 4.400 ft.
Area Weighted Alrerage SHGC: 0.276
14. Hot water systems
8. Floor Types (326.0 sgft.) Insulation Area
a. Electric
Cap: 2 gallons
a. Slab -On -Grade Edgp Insulation R=0.0 320.00 ftz
b. N/A
b. Conservation features
EF: 0.950
� R_ �
c. N/A R= ftz
None
15. Credits
-
CF, Pstat
Glass/FiobrArea:'. 4.260
Total Proposed Modified Loads: 18.39
Total
PASS
Baseline
Loads: 19.18
I hereby certify that th ' plans and specifications covered by
this calculation are in
Review of the plans and
TSB ST
mpliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
y �,% $ �.� �V6
Y•'
with the Florida Energy Code.
Before
ATE: D
DATE: -
construction is completed
..
this building e inspected for
will b
i
� ly a°�
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
with the Florida Energy Code.
Florida Statutes.
*
4+�D yyg'S�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- %oumpnance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certifledfactory-sealed In accordance with R403.3.2.1.
- Compliance requlres an Air Barrier and Insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an
:envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
DECEIVED
MAR 21 2018
2012018 2:50 PM
ST. Lucie County, Permitting
EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software
Page 1 of 4
FORM R405-2017
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
DAVID GREEN
User
DAVID GREEN
1
ST. LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 0
Conditioned Area: 320
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
143 DUSK WAY
St. Lucie
FT. PIERCE,
FL,
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL VERO BEACH_MUNI 39 90
70 75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Entire House
320 2880
SPACES
Number.
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
FAMILY ROOM
320 2880 Yes 2
1 Yes
Yes Yes
FLOORS
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio FAMILY ROOM 52 ft 0
320 ft2 _---
0 1 0
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt
Absor. Tested
Emitt Deck Pitch
Tested Insul. (deg)
1
Hip
Metal 337 ft2 0 ft2 Light
0.6 No 0.9
No 0 18.4
ATTIC
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1 '
Full attic
Vented 300
320 ft2 N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
FAMILY ROOM 30 Batt
320 ft2 0.1
Wood
3/20/2018 2:50 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017'
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar
Below
1 -N
Exterior Concrete
Block - Ext InfiAMILY ROO 4.1 16 0 9
0
144.0 ftZ 0
0 0.6
0
2 E
Exterior Concrete
Block - Ext In€iAMILY ROO 4.1 20 0 9
0
180.0 ft2 0
0 0.6
0
-3 S
Oterior Concrete Block - Ext In€iAMILY ROO 4.1 16 0 9
0
144.0 ftz 0
0 0.6
0
DOORS
#
Ornt
Door Type Space Storms
U-Value Width
Height
Area
Ft In
Ft In
1
h
S
Insulated FAMILY ROO None
.46
3
6 8
20 ftZ
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
Ornt ID Frame
Panes NFRC U-Factor SHGC Imp
Area
Depth Separation Int Shade
Screening
1
N 1 Metal
Low-E Double Yes 0.65 0.25 N
20.0 W
2 ft 0 in 1 ft 4 in
None
None
2
E 2 Metal
Low-E Double Yes 0.65 0.25 N
20.0 ftz
8 ft 0 in 1 ft 4 in
None
None
3
E 2 Metal
Low-E Double Yes 0.65 0.3 N
6.7 ftZ
8 ft 0 in 1 ft 4 in
None
None
4
E `. 2 Metal
Low-E Double Yes 0.65 0.3 N
6.7 ftz
8 ft 0 in 1 ft 4 in
None
None
5
S ' 3 Metal
Low-E Double Yes 0.65 0.3 N
15.0 ftZ
2 ft 0 in 1 ft 4 in
None
None
6 .
S 3 Metal
Low-E Double Yes 0.65 0.3 N
15.0 ftz
2 ft 0 in 1 ft 4 in
None
None
INFILTRATION
# Scope
Method
SLA CFM 50 ELA EgLA
ACH ACH 50
1 Wholehouse Proposed ACH(50) .0004 336 18.45 34.69
.2922
7
HEATING SYSTEM
#
System Type
Subtype Efficiency
Capacity
Block
Ducts
1 '
Electric Strip Heat/ None COPA
17.45 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/
Split SEER: 16
39 kBtu/hr cfm
0.8 1
sys#1
HOT WATER SYSTEM
#.
System Type
SubType Location EF Cap
Use
SetPnt
Conservation
1 '
Electric
None FAMILY ROOM).95 2 gal 60 gal
120 deg
None
3/20/2018-2:50 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017
SOLAR HOT WATER SYSTEM
F1
FSEC
Collector
Storage
Cert #
Company Name
System Model # Collector Model
#
Area
Volume
FEF
None
None
tt=
DUCTS
/
-- Supply —
— Return --
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN RLF
Heat Cool
1
Attic
6 128 ft2
Attic
89 ft2 Default Leakage
Attic
(Default) (Default)
1 1
!
TEMPERATURES
Programable Thermostat:
Y
Ceiling Fans:
Cooling Jan
Heating Jan
Feb
Feb
Mar
Mar
HX
E
Apr
Apr f
May X Jun X Jul
May Jun f Jul
[X Auge
[ Auf
Sep E
Oct
Oct
Nov
Nov
Dec
Dec
Venting Jan
Feb
Mar
[Xl
Apr [
May Jun [ Jul
[ Aug
[
Se [x]
X
Oct X
Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78 78 78
78
78
80
80
80
80
PM
80
80
78
78 78 78
78
78
78
78
78
78
Cooling (WES
AM
78
78
78
78 78 78
78
78
78
78
78
78
PM
78
78
78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66 66 68
68
68
68
68
68
68
PM
68
68
68
68 68 68
68
68
68
68
66
66
3/20/2018 2:50 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: DAVID GREEN Builder Name:
Street: 143 DUSK WAY Permit Office: ST. LUCIE COUNTY
City, State, Zip; FT. PIERCE, FL, Permit Number: `� w
` '
Owner: DAVID GREEN Jurisdiction:
r ` ,
Design Location: FL, Fort Pierce
COMPONENT
AIR BARRIER CRITERIA
INSULATIO�;�IAtTION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
atiip'stfall
Air -permeable inNSI
requirements
The exterior thermal envelope contains a continuous air barrier.
not'be used as aaling material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity with
sealed.
a material having a thermal resistance of R-3 per inch
Knee walls shall be sealed.
minimum.
Exterior thermal envelope insulation for framed walls
shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace walls
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing -.and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
_
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
• •_
a In wiAMnn ina•.ncnHi.n
. i...v .....u....pyunkler cover ________ .and walls or . . ..__
.+......... . ....p..va.vu w wu rvana m,au 00 ill aGw1uafice With Hic provibionu of IGG-400.
3/20/2018' 2:51 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD.
INDEX'
ESTIMATED ENERGY PERFORMANCE
The lower the EnergyPerformance Index, the more efficient the ho
1. New construction or existing
2. Single family or multiple family
3. Number of -units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft2)
7. Windows'*
Description
a. U-Factor:
Dbl, U=0.65
SHGC:
SHGC=0.30
b. U-Factor:
Dbl, U=0.65
SHGC:
SHGC=0.25
c. U-Factor:
N/A
SHGC:
d. U-Factor: N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
143 DUSK WAY, FT. PIERCE, FL, ii,
New (From Plans) 9. Wall Types
Single-family a. Concrete Block - Ext Insul, Exterior
b. N/A
1 c. N/A
n d. N/A
No 10. Ceiling Types
a. Under Attic (Vented)
320 b. N/A
Area c. N/A
43.33 ft2 11. Ducts
a. Sup: Attic, Ret: Attic, AH: Attic
40.00 ft2
8. Floor Types Insulation
a. Slab -On -Grade Edge Insulation R=0.0
b. N/A R=
c. N/A R=
12. Cooling systems
ft2
a. Central Unit
ft2
13. Heating systems
a. Electric Strip Heat
4.400 ft.
0.276
Area
14. Hot water systems
320.00 ft2
a. Electric
ft2
ft2
b. Conservation features
None
15. Credits
I certify that this home: has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this horrre before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant featur ... `
Builder Signature: �/ Date: - Z t-
Address of New Home: /`'l13 5� �q :)erct' City/FL Zip:
Insulation Area
R=4.1 468.00 ft2
R=
ft2
R=
ft2
R=
ft2
Insulation
Area
R=30.0
320.00 ftz
R=
ft2
R=
ft2
R ft2
6 128
kBtu/hr Efficiency
39.0 SEER:16.00
kBtu/hr Efficiency
17.4 COP:1.00
Cap: 2 gallons
EF: 0.95
CF, Pstat
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at
techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of
certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building
Commission's support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
3/20/2018 2:51 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1
Pro ect Summary Job:
- wrightsoft® Date: Feb 08, 2018
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@40L.COM
Prowect Information
For: DAVID GREEN ADDITION
143 DUSK WAY, FT. PIERCE, FL v
�� •n 1j31 ...1 R1L'
Design
• •
Weather: Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db
42 OF
Outside db
90
OF
Inside db
70 OF
Inside db
75
OF
Design TD
28 OF
Design TD
15
OF
Daily.range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Heating Summary
Sensible Cooling Equipment
Load
Sizing
Structure
23241 Btuh
Structure
22198
Btuh
Ducts
6125 Bt6h
Ducts
8703
Btuh
Central vent (67 cfm)
2068 Btuh
Central vent (67 cfm)
1108
Btuh
Outside air
Outside air
Humidification
0 Btuh
Blower
0
Btuh
Piping
0 Btuh
Equipment load
31433 Btuh
Use manufacturer's data
n
Rate/swing multiplier
Equipment load
0.95
30408
Btuh
Infiltration
sensible
Method
Simplified
Latent Cooling Equipment Load
Sizing
Construction quality
Average
Fireplaces
0
Structure
3406
Btuh
Ducts
2723
Btuh
Central vent (67 cfm)
2807
Btuh
Area
Heatingg Cooling
Outside air
�ft3)
1760 1760
Equipment latent load
8936
Btuh
Volumee
15840 15840
Air changes/hour
0.38 0.20
Equipment total load
39345
Btuh
Equiv. AVF (cfm)
100 53
Req. total capacity at 0.70 SHR
3.6
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Lennox
Trade
Trade MERIT
Model
Cond 14ACX-041-230*
AHRI ref
Coil CBX27UH-048-230*++TDR
AHRI ref 3869097
Efficiency
100 EFF
Efficiency 13.0 EER, 16
SEER
Heating Input
5.1 kW
Sensible cooling
27300
Btuh
Heating output
17448 Btuh
Latent cooling
11700
Btuh
Temperature rise
12 OF
Total cooling
39000
Btuh
Actual air flow
1300 cfm
Actual air flow
1300
cfm
Air flow factor
0.044 cfm/Btuh
Air flow factor
0.042
cfm/Btuh
Static pressure
0.08 in H2O
Static pressure
0.08
in H2O
Space thermostat
Load sensible heat ratio
0.78
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
C WI'1 I7t50ft® 2018-Feb-09 07:47:55
9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
�� C:\Users\Quick Calcs%Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N
- wrightsofta Right-M Worksheet Job:
Entire House Date: Feb 08, 2018
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Entire House
216.0 ft
9.0 ft d
1760.0 ft2
FAMILY ROOM
52.0 ft
9.0 ft heat/cool
20.0 x 16.0 ft
320.0 ftz
Ty
Construction
number
U-value
(Btuh/ft2-°F)
Or
HTM
(Btuh/ft�
Area (ft�
or perimeter (ft)
Load
(Btuh)
Area (ft�
or perimeter (ft)
Load
(Btuh)
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
'1�J
! G-
13A-flocs -
4A5-2om_-
13A-4ocs
1A-c1om
4A5-2om
4A5-2om
4A5-2om
11 DO - _ n.-- _-- --
13A-0ocs
4A5-2orn _
13A-4ocs
1A-c1om
1A-clomd
16X19-Oad
22A tpl- _
0143
__ 0.770
0.143
1.270
0.770
0.770
0.770
-_ - 0.390
0 143
_-0 770
0.143
1.270
1.270
0.408
-n
�n_
a
a
a
a
a
_ e-
s '
;s_
w
w
w
-
„_
~' 4.00
�21.56
4.00
35.56
21.56
21.56
21.56
10.92
4.00
_.__21.56
4.00
35.56
35.56
1.59
27:69
2 55
_ 19.31.
2.55
91.12
45.10
19.31
25.28
_11_31
2.55
_ 19.31,
2.55
91.12
91.12
1.49
0,00
__'_- 432
---_20-
540
24
15
15
14
21
7412
0:
451
0
1
15
11
21
µ1650
,__-_431
1807
853
323
323
293
_----_229
� 1610
647
1903
853
1451
-..__1290
507
_5981,
" 1049
. _�-386
1149
2187
677
290
344
^_ _ 238
1023
__ 579
1210
2187
3718
;. 2419
476
_ 0
-_ --1-4-4
1
20
180
0
15
15
14
_-_-0
144
---:IQ,_ 0
0
0
0
_ Q
320
_______ 320
124
___` 0
136
0
1
15
11
_-T_ 0
114
30
0
0
0
320
_ --52
--_ 431.
546
0
323
323
293
-_-__0
456
-_647
0
0
0
507
----L44Q
___386
347
0
677
290
344
_-..----_-,0
- 290
579
0
0
0
476
- _._-0
---_- _-
w
_
wI -
_
' - 432
_____�30
540
24
41
-- -
, 4tff
'_-.--30
475
0
0
�--G
C
F
_ _ 320
__ _1760_
440.
320
__216
- Q 989
6
c) AED excursion
818
-128
Envelope loss/gain
20154
18748
5464
3576
12
a) Infiltration
b) Room ventilation
3087
0
870
0
743
0
210
0
13
Internal gains: Occupants @ 230
Appliances/other
6
1380
1200
2
460
0
Subtotal (lines 6 to 13)
23241
22198
6208
4246
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
26%
39%
0
0
0
23241
6125
0
0
0
22198
8703
20%
15%
0
0
0
6208
1265
0
0
0
4246
629
Total room load
Air required (cfm)
29365
1300
30901
1300
7473
331
4875
205
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wriglltsOft' 2018-Feb-09 07:47:55
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1
ACC" C:\Users\Quick Calcs\Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N
-�- wrightsoftm Right-J® Worksheet Job:
Entire House Date: Feb 08, 2018
By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@4OL.COM
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
EXISTING HOUSE
164.0 ft
9.0 ft heat/cool
1.0 x 1440.0 ft
1440.0 ft2
Ty
Construction
number
U-value
(13tuh/ft2-°F)
Or
HTM
(13tuh/ft2)
Area (ft2)
or perimeter (ft)
Load
(13tuh)
Area
or perimeter
Load
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
_! -
13A oCs
_4A5-2om.__-___��
13A-4ocs
1A-clom
4A5-2om
4A5-2om
4A5-2om
11D0
13A-4ocs
4A5.2om--- _
13A-4ocs
1A-clom
1A-clomd Y-
- 0 143
`._0 770
0.143
1.270
0.770
0.770
0.770
0_390
--0.143
_-_0.7.70
0.143
1.270
1.270
n
_-n
a
a
a
a
a
a
• s
_.s-
w
w
w
4.00
4.00
35.56
21.56
21.56
21.56
10.92
4.00
-21 56
4.00
35.56
35.56
2.55
2.55
91.12
45.10
19.31
25.28
_ 11.31
2:55-
19 31-
2.55
91.12
288
360
24
0
0
0
21_
_-__. 288
____Q
540
24
41
1153
___ 733
802
2187
0
0
0
__-._
733
____ 0
1210
2187
3718
^
-
315
0
0
0
0
___ 21
V'288
,-- Q
475
0
0
1261
853
0
0
0
_ 229
- 71153
.- ' 0
1903
853
1451
W _ -
�-G
�238 _ --
--
-- -
--
- ---- -
_ --_
-� -
,--
W,
L��G
C _y
C _
6B_30ad _ �
16X19-0ad _
_
- 0.032
_ 0.408
_
_
_-
_
.� _0.90
1.59
`27.159
_91.12
_ 1.68.
1.49
0.00
_
-__.1440
0
_}.1440
_1440
0
_ _164.
^ 1290
_ _ 0
_ 4541.
- __2419
_ _ 0
6
c) AED excursion
946
Envelope loss/gain
14689
15172
12
a) Infiltration
b) Room ventilation
2344
0
661
0
13
Internal gains: Occupants @ 230
Appliances/other
4
920
1200
Subtotal (lines 6 to 13)
17033
17953
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct loads
29%
45%
0
0
0
17033
4860
0
0
0
17953
8074
Total room load
Air required (cfm)
21893
%91
26027
1095
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wrightsoft• 2018-Feb-09 07:47:55
Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2
ACZ5N C:\Users\Quick Calcs\Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N
Duct System Summary Job:
wrightsoft® Date: Feb 08, 2018
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@_AOL.COM
Project• •
For: DAVID GREEN ADDITION
143 DUSK WAY, FT. PIERCE, FL
Heating
Cooling
External static pressure
0.08
in H2O
0.08
in H2O
Pressure losses
0
in H2O
0
in H2O
Available static pressure
0.08
in H2O
0.08
in H2O
Supply / return available pressure
0.040 / 0.040
in H2O
0.040 / 0.040
in H2O
Lowest friction rate
0.074
in/100ft
0.074
in/100ft
Actual air flow
1300
cfm
1300
cfm
Total effective length (TEL)
107 ft
Design
Htg
Clg
Design
Diam
H x W
Duct
Actual
Ftg.Egv
Name
(Btuh)
(cfm)
(cfm)
FR
(in)
(in)
Matl
Ln (ft)
Ln (ft)
Trunk
EXISTING HOUSE-F
c 26027
969
1095
0
0
Ox 0
VIFx
0
0
FAMILY ROOM
h 3736
165
103
0.074
7.0
Ox 0
VIFx
17.4
90.0
st1
FAMILY ROOM -A
h 3736
165
103
0.075
7.0
Ox 0
VIFx
16.2
90.0
st1
Supply Trunk Detail Table
Name
Trunk
Type
Htg
(cfm)
Clg
(cfm)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Duct
Material
Trunk
st1
Peak AVF
331
205
0.074
606
10.0
0 x 0
VinlFlx
Name
Grille
Size (in)
Htg
(cfm)
Clg
(cfm)
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Mat[
Trunk
rb2
Ox 0
1300
1300
0
0
0
0
Ox 0
VIFx
k wri htsoft® 2018-Feb-09 07:47:55
�, 9 Right -Suite® Universal 2017 17.0.14 RSU08101 page 1
ACCA C:\Users\Quick Calcs\Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N