Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEBY FORM R405-2017Moot FLORIDA ENERGY-EF IICIE CY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: DAVID GREEN Builder Name: Street: 143 DUSK WAY City, State, Zip: FT. PIERCE, FL, Permit Office: ST. LUCIE COUNTY . Owner. . ' DAVID GREEN Permit Number. Design Location: FL, Fort Pierce Jurisdiction: County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing Addition 9. Wall Types (468.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 468.00 ftz 3. Number: bf units, if multiple family 1 b. N/A R= ftz 4. Number of Bedrooms 0 c. N/A d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (320.0 sgft.) R= ftz Insulation Area 6. Conditioned floor area above grade (ftz) 320 a. Under Attic (Vented) b. N/A R=30.0 320.00 ftz Conditioned floor area below grade (ftz) 0 c. WA R= ftz R= ftz 7. Windows(83.3 sgft.) Description Area a. U-Factor. 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic R ftz 6 128 Dbl, U=0.65 43.33 ftz SHGC: SHGC=0.30 b. U-Factor. Dbl, U=0.65 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 39.0 SEER:16.00 c. U-Factor: - WA ftz SHGC: d. U-Factor. N/A ft2 13. Heating systems kBtu/hr Efficiency SHGC: a. Electric Strip Heat 17.4 COP:1.00 Area Weighted Average Overhang Depth: 4.400 ft. Area Weighted Alrerage SHGC: 0.276 14. Hot water systems 8. Floor Types (326.0 sgft.) Insulation Area a. Electric Cap: 2 gallons a. Slab -On -Grade Edgp Insulation R=0.0 320.00 ftz b. N/A b. Conservation features EF: 0.950 � R_ � c. N/A R= ftz None 15. Credits - CF, Pstat Glass/FiobrArea:'. 4.260 Total Proposed Modified Loads: 18.39 Total PASS Baseline Loads: 19.18 I hereby certify that th ' plans and specifications covered by this calculation are in Review of the plans and TSB ST mpliance with the Florida Energy Code. specifications covered by this calculation indicates compliance y �,% $ �.� �V6 Y•' with the Florida Energy Code. Before ATE: D DATE: - construction is completed .. this building e inspected for will b i � ly a°� compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance with the Florida Energy Code. Florida Statutes. * 4+�D yyg'S� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - %oumpnance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certifledfactory-sealed In accordance with R403.3.2.1. - Compliance requlres an Air Barrier and Insulation inspection Checklist in accordance with R402.4.1.1 and this project requires an :envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). DECEIVED MAR 21 2018 2012018 2:50 PM ST. Lucie County, Permitting EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 1 of 4 FORM R405-2017 PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: DAVID GREEN User DAVID GREEN 1 ST. LUCIE COUNTY Single-family New (From Plans) Bedrooms: 0 Conditioned Area: 320 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Lot # Block/Subdivision: PlatBook: Street: County: City, State, Zip: Street Address 143 DUSK WAY St. Lucie FT. PIERCE, FL, CLIMATE / V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 320 2880 SPACES Number. Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 FAMILY ROOM 320 2880 Yes 2 1 Yes Yes Yes FLOORS Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio FAMILY ROOM 52 ft 0 320 ft2 _--- 0 1 0 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar SA Emitt Absor. Tested Emitt Deck Pitch Tested Insul. (deg) 1 Hip Metal 337 ft2 0 ft2 Light 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 ' Full attic Vented 300 320 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) FAMILY ROOM 30 Batt 320 ft2 0.1 Wood 3/20/2018 2:50 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 4 FORM R405-2017' WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 -N Exterior Concrete Block - Ext InfiAMILY ROO 4.1 16 0 9 0 144.0 ftZ 0 0 0.6 0 2 E Exterior Concrete Block - Ext In€iAMILY ROO 4.1 20 0 9 0 180.0 ft2 0 0 0.6 0 -3 S Oterior Concrete Block - Ext In€iAMILY ROO 4.1 16 0 9 0 144.0 ftz 0 0 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 h S Insulated FAMILY ROO None .46 3 6 8 20 ftZ WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal Low-E Double Yes 0.65 0.25 N 20.0 W 2 ft 0 in 1 ft 4 in None None 2 E 2 Metal Low-E Double Yes 0.65 0.25 N 20.0 ftz 8 ft 0 in 1 ft 4 in None None 3 E 2 Metal Low-E Double Yes 0.65 0.3 N 6.7 ftZ 8 ft 0 in 1 ft 4 in None None 4 E `. 2 Metal Low-E Double Yes 0.65 0.3 N 6.7 ftz 8 ft 0 in 1 ft 4 in None None 5 S ' 3 Metal Low-E Double Yes 0.65 0.3 N 15.0 ftZ 2 ft 0 in 1 ft 4 in None None 6 . S 3 Metal Low-E Double Yes 0.65 0.3 N 15.0 ftz 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .0004 336 18.45 34.69 .2922 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 ' Electric Strip Heat/ None COPA 17.45 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 39 kBtu/hr cfm 0.8 1 sys#1 HOT WATER SYSTEM #. System Type SubType Location EF Cap Use SetPnt Conservation 1 ' Electric None FAMILY ROOM).95 2 gal 60 gal 120 deg None 3/20/2018-2:50 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2017 SOLAR HOT WATER SYSTEM F1 FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None tt= DUCTS / -- Supply — — Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 128 ft2 Attic 89 ft2 Default Leakage Attic (Default) (Default) 1 1 ! TEMPERATURES Programable Thermostat: Y Ceiling Fans: Cooling Jan Heating Jan Feb Feb Mar Mar HX E Apr Apr f May X Jun X Jul May Jun f Jul [X Auge [ Auf Sep E Oct Oct Nov Nov Dec Dec Venting Jan Feb Mar [Xl Apr [ May Jun [ Jul [ Aug [ Se [x] X Oct X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WES AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 3/20/2018 2:50 PM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 4 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: DAVID GREEN Builder Name: Street: 143 DUSK WAY Permit Office: ST. LUCIE COUNTY City, State, Zip; FT. PIERCE, FL, Permit Number: `� w ` ' Owner: DAVID GREEN Jurisdiction: r ` , Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATIO�;�IAtTION CRITERIA General A continuous air barrier shall be installed in the building envelope. atiip'stfall Air -permeable inNSI requirements The exterior thermal envelope contains a continuous air barrier. not'be used as aaling material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing -.and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall _ be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids • •_ a In wiAMnn ina•.ncnHi.n . i...v .....u....pyunkler cover ________ .and walls or . . ..__ .+......... . ....p..va.vu w wu rvana m,au 00 ill aGw1uafice With Hic provibionu of IGG-400. 3/20/2018' 2:51 PM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD. INDEX' ESTIMATED ENERGY PERFORMANCE The lower the EnergyPerformance Index, the more efficient the ho 1. New construction or existing 2. Single family or multiple family 3. Number of -units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows'* Description a. U-Factor: Dbl, U=0.65 SHGC: SHGC=0.30 b. U-Factor: Dbl, U=0.65 SHGC: SHGC=0.25 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 143 DUSK WAY, FT. PIERCE, FL, ii, New (From Plans) 9. Wall Types Single-family a. Concrete Block - Ext Insul, Exterior b. N/A 1 c. N/A n d. N/A No 10. Ceiling Types a. Under Attic (Vented) 320 b. N/A Area c. N/A 43.33 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 40.00 ft2 8. Floor Types Insulation a. Slab -On -Grade Edge Insulation R=0.0 b. N/A R= c. N/A R= 12. Cooling systems ft2 a. Central Unit ft2 13. Heating systems a. Electric Strip Heat 4.400 ft. 0.276 Area 14. Hot water systems 320.00 ft2 a. Electric ft2 ft2 b. Conservation features None 15. Credits I certify that this home: has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this horrre before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant featur ... ` Builder Signature: �/ Date: - Z t- Address of New Home: /`'l13 5� �q :)erct' City/FL Zip: Insulation Area R=4.1 468.00 ft2 R= ft2 R= ft2 R= ft2 Insulation Area R=30.0 320.00 ftz R= ft2 R= ft2 R ft2 6 128 kBtu/hr Efficiency 39.0 SEER:16.00 kBtu/hr Efficiency 17.4 COP:1.00 Cap: 2 gallons EF: 0.95 CF, Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 3/20/2018 2:51 PM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 Pro ect Summary Job: - wrightsoft® Date: Feb 08, 2018 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@40L.COM Prowect Information For: DAVID GREEN ADDITION 143 DUSK WAY, FT. PIERCE, FL v �� •n 1j31 ...1 R1L' Design • • Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily.range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 23241 Btuh Structure 22198 Btuh Ducts 6125 Bt6h Ducts 8703 Btuh Central vent (67 cfm) 2068 Btuh Central vent (67 cfm) 1108 Btuh Outside air Outside air Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 31433 Btuh Use manufacturer's data n Rate/swing multiplier Equipment load 0.95 30408 Btuh Infiltration sensible Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3406 Btuh Ducts 2723 Btuh Central vent (67 cfm) 2807 Btuh Area Heatingg Cooling Outside air �ft3) 1760 1760 Equipment latent load 8936 Btuh Volumee 15840 15840 Air changes/hour 0.38 0.20 Equipment total load 39345 Btuh Equiv. AVF (cfm) 100 53 Req. total capacity at 0.70 SHR 3.6 ton Heating Equipment Summary Cooling Equipment Summary Make Make Lennox Trade Trade MERIT Model Cond 14ACX-041-230* AHRI ref Coil CBX27UH-048-230*++TDR AHRI ref 3869097 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating Input 5.1 kW Sensible cooling 27300 Btuh Heating output 17448 Btuh Latent cooling 11700 Btuh Temperature rise 12 OF Total cooling 39000 Btuh Actual air flow 1300 cfm Actual air flow 1300 cfm Air flow factor 0.044 cfm/Btuh Air flow factor 0.042 cfm/Btuh Static pressure 0.08 in H2O Static pressure 0.08 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. C WI'1 I7t50ft® 2018-Feb-09 07:47:55 9 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 �� C:\Users\Quick Calcs%Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N - wrightsofta Right-M Worksheet Job: Entire House Date: Feb 08, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 216.0 ft 9.0 ft d 1760.0 ft2 FAMILY ROOM 52.0 ft 9.0 ft heat/cool 20.0 x 16.0 ft 320.0 ftz Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft� Area (ft� or perimeter (ft) Load (Btuh) Area (ft� or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 '1�J ! G- 13A-flocs - 4A5-2om_- 13A-4ocs 1A-c1om 4A5-2om 4A5-2om 4A5-2om 11 DO - _ n.-- _-- -- 13A-0ocs 4A5-2orn _ 13A-4ocs 1A-c1om 1A-clomd 16X19-Oad 22A tpl- _ 0143 __ 0.770 0.143 1.270 0.770 0.770 0.770 -_ - 0.390 0 143 _-0 770 0.143 1.270 1.270 0.408 -n �n_ a a a a a _ e- s ' ;s_ w w w - „_ ~' 4.00 �21.56 4.00 35.56 21.56 21.56 21.56 10.92 4.00 _.__21.56 4.00 35.56 35.56 1.59 27:69 2 55 _ 19.31. 2.55 91.12 45.10 19.31 25.28 _11_31 2.55 _ 19.31, 2.55 91.12 91.12 1.49 0,00 __'_- 432 ---_20- 540 24 15 15 14 21 ­7412 0: 451 0 1 15 11 21 µ1650 ,__-_431 1807 853 323 323 293 _----_229 � 1610 647 1903 853 1451 -..__1290 507 _5981, " 1049 . _�-386 1149 2187 677 290 344 ^_ _ 238 1023 __ 579 1210 2187 3718 ;. 2419 476 _ 0 -_ --1-4-4 1 20 180 0 15 15 14 _-_-0 144 ---:IQ,_ 0 0 0 0 _ Q 320 _______ 320 124 ___` 0 136 0 1 15 11 _-T_ 0 114 30 0 0 0 320 _ --52 --_ 431. 546 0 323 323 293 -_-__0 456 -_647 0 0 0 507 ----L44Q ___386 347 0 677 290 344 _-..----_-,0 - 290 579 0 0 0 476 - _._-0 ---_- _- w _ wI - _ ' - 432 _____�30 540 24 41 -- - , 4tff '_-.--30 475 0 0 �--G C F _ _ 320 __ _1760_ 440. 320 __216 - Q 989 6 c) AED excursion 818 -128 Envelope loss/gain 20154 18748 5464 3576 12 a) Infiltration b) Room ventilation 3087 0 870 0 743 0 210 0 13 Internal gains: Occupants @ 230 Appliances/other 6 1380 1200 2 460 0 Subtotal (lines 6 to 13) 23241 22198 6208 4246 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 26% 39% 0 0 0 23241 6125 0 0 0 22198 8703 20% 15% 0 0 0 6208 1265 0 0 0 4246 629 Total room load Air required (cfm) 29365 1300 30901 1300 7473 331 4875 205 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wriglltsOft' 2018-Feb-09 07:47:55 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 1 ACC" C:\Users\Quick Calcs\Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N -�- wrightsoftm Right-J® Worksheet Job: Entire House Date: Feb 08, 2018 By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@4OL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area EXISTING HOUSE 164.0 ft 9.0 ft heat/cool 1.0 x 1440.0 ft 1440.0 ft2 Ty Construction number U-value (13tuh/ft2-°F) Or HTM (13tuh/ft2) Area (ft2) or perimeter (ft) Load (13tuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 _! - 13A oCs _4A5-2om.__-___�� 13A-4ocs 1A-clom 4A5-2om 4A5-2om 4A5-2om 11D0 13A-4ocs 4A5.2om--- _ 13A-4ocs 1A-clom 1A-clomd Y- - 0 143 `._0 770 0.143 1.270 0.770 0.770 0.770 0_390 --0.143 _-_0.7.70 0.143 1.270 1.270 n _-n a a a a a a • s _.s- w w w 4.00 4.00 35.56 21.56 21.56 21.56 10.92 4.00 -21 56 4.00 35.56 35.56 2.55 2.55 91.12 45.10 19.31 25.28 _ 11.31 2:55- 19 31- 2.55 91.12 288 360 24 0 0 0 21_ _-__. 288 ____Q 540 24 41 1153 ___ 733 802 2187 0 0 0 __-._ 733 ____ 0 1210 2187 3718 ^ - 315 0 0 0 0 ___ 21 V'288 ,-- Q 475 0 0 1261 853 0 0 0 _ 229 - 71153 .- ' 0 1903 853 1451 W _ - �-G �238 _ -- -- -- - -- - ---- - _ --_ -� - ,-- W, L��G C _y C _ 6B_30ad _ � 16X19-0ad _ _ - 0.032 _ 0.408 _ _ _- _ .� _0.90 1.59 `27.159 _91.12 _ 1.68. 1.49 0.00 _ -__.1440 0 _}.1440 _1440 0 _ _164. ^ 1290 _ _ 0 _ 4541. - __2419 _ _ 0 6 c) AED excursion 946 Envelope loss/gain 14689 15172 12 a) Infiltration b) Room ventilation 2344 0 661 0 13 Internal gains: Occupants @ 230 Appliances/other 4 920 1200 Subtotal (lines 6 to 13) 17033 17953 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 29% 45% 0 0 0 17033 4860 0 0 0 17953 8074 Total room load Air required (cfm) 21893 %91 26027 1095 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoft• 2018-Feb-09 07:47:55 Right -Suite® Universal 2017 17.0.14 RSU08101 Page 2 ACZ5N C:\Users\Quick Calcs\Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N Duct System Summary Job: wrightsoft® Date: Feb 08, 2018 Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@_AOL.COM Project• • For: DAVID GREEN ADDITION 143 DUSK WAY, FT. PIERCE, FL Heating Cooling External static pressure 0.08 in H2O 0.08 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.08 in H2O 0.08 in H2O Supply / return available pressure 0.040 / 0.040 in H2O 0.040 / 0.040 in H2O Lowest friction rate 0.074 in/100ft 0.074 in/100ft Actual air flow 1300 cfm 1300 cfm Total effective length (TEL) 107 ft Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln (ft) Ln (ft) Trunk EXISTING HOUSE-F c 26027 969 1095 0 0 Ox 0 VIFx 0 0 FAMILY ROOM h 3736 165 103 0.074 7.0 Ox 0 VIFx 17.4 90.0 st1 FAMILY ROOM -A h 3736 165 103 0.075 7.0 Ox 0 VIFx 16.2 90.0 st1 Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 331 205 0.074 606 10.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mat[ Trunk rb2 Ox 0 1300 1300 0 0 0 0 Ox 0 VIFx k wri htsoft® 2018-Feb-09 07:47:55 �, 9 Right -Suite® Universal 2017 17.0.14 RSU08101 page 1 ACCA C:\Users\Quick Calcs\Documents\GREEN, DAVID.rup Calc = MJ8 Front Door faces: N