Loading...
HomeMy WebLinkAboutSOIL NUCLEAR GAUGE0 0 Port St. Lucie d FBPE CA#4930 N 607 NW Commodity Cove N Port St. Lucie, FL 34986 0 Phone: 772-924-3575 1 Fax: 772-924-3580 N r9 co O N 00 N N O E 0 L LL SCANNED Soil Nuclear Gauge client: By RECEIVED 11cleCOW* Project: Report Date: 3/28/2018 David Green / Amanda Green 18-5200.00 MAR 2 ,�18 Test Method: ASTM D 6938 143 Dusk Way 143 Dusk Way Fort Pierce, FL 34981 Fort Pierce, FL Permitting Department St. Lucie County Test# Retest Of Test Date ProctorlD Method Soil Classification Optimum Moisture (%) Maximum Dry Density (pcf) In Place Moisture (%) In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. (%) Remark 1 3/26118 P-1 N/A 10.0 110.0 10.0 105.0 12 95 95 / 105 Pass 2 3/26/18 P-1 N/A 10.0 110.0 8.9 106.2 12 97 95 / 105 Pass estl formation .. . . .. ,.. Test # Test Location Elevation Reference Gauge Make / Model / SN / Calibrated Field Technician 1 Below Slab Grade: Eastside Room Addition, E Section 0-1 Troxler 13440 127976 / Smith, Johnnie 2 Below Slab Grade: Eastside Room Addition, W Section 0 1 Troxler / 3440 / 27976 / Smith, Johnnie emarkS "COmrii@ntS'` Pass: Tests results comply with specifications Tests are "Direct Transmission' (Method A) unless probe depth is noted as 'Backscatter'. Gauge calibration data on file with the testing agency. PERMIT # 18-02-0329 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. \\�tt1111111///// �tCENgF' . 632 8 03128/20:18 _= 4JDent, P.E. • ill ; PrIon a T TE,�OFe� G ��C[ 8 State'gf'yt+AL ,11111111W Digitally signed printed Copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1 Soil Nuclear Gauge Client:. Project: Report Date: 3/28/2018 David Green / Amanda Green 18-5200.00 Test Method: ASTM D 6938 143 Dusk Way 143 Dusk Way Port St. Lucie Fort Pierce, FL 34981 Fort Pierce, FL FBPE CA # 4930 607 NW Commodity Cove Port St. Lucie, FL 34986 Phone: 772-924-3575 1 Fax: 772-924-3580 Test Results Test # Retest Of Test Date Proctor ID Method Soil Classification Optimum Moisture N Maximum Dry Density (pcf) In Place Moisture N In Place Dry Density (pcf) Probe Depth (in) Percent Compaction Min/Max Comp. N Remark 1 3/26/18 P-1 N/A 10.0 110.0 10.0 105.0 12 95 951105 Pass 2 3/26/18 P-1 N/A 10.0 110.0 8.9 106.2 12 97 951105 Pass Test Information Test # Test Location Elevation Reference Gauge Make I Model / SN / Calibrated Field Technician 1 Below Slab Grade: Eastside Room Addition, E Section 0-1 Troxler / 3440 / 27976 / Smith, Johnnie 2 Below Slab Grade: Eastside Room Addition, W Section 0-1 Troxler / 3440 / 27976 / Smith, Johnnie Remarks Comments Pass: Tests results comply with specifications Tests are "Direct Transmission" (Method A) unless probe depth is noted as "Backscatter". Gauge calibration data on file with the testing agency. PERMIT �8-OZ-Q329 Test Reports shall not be reproduced, except in full, without the written approval of GFA International Inc. ��111111►//I 9." 632 803/28/20:18 — JD Kent, P.E. TATE OF Pr�11 .' *as)� ... 0' -, 9/ Stater Digitally signed printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Page 1 of 1