�t MiTek' RE: 1325607 - Site Information: Customer Info: PIA -Joey Alkire Lot/Block: .. Address: 143 Dusky Way City: Fort Pierce Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. Project Name: 1325607 Model: Green Addition Subdivision: .. State: Florida MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: State: General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 160 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 9 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. I Seal# Truss Name I Date 1 IT13090216IT01 1/30/18 12 I T13090217 I T02 1 1/30/18 13 I T13090218 I T03 1 1130/18 1 14 I T13090219 j T04 1 1/30/18 1 15 1 T13090220 1 V01 1 1 /30/18 1 16 1 T1 30902211 V02 1 1 /30/18 J 17 1 T13090222 1 V03 1 1/30/18 18 1 T13090223 1 VO4 1 1 /30/18 19 _ 1 T13090224 1 V05 1 1 /30/18 1 The truss drawing(s) referenced above have been prepared by MiTek USA, Inc. under my direct supervision based on the parameters provided by Builders FirstSource - Plant City. Truss Design Engineer's Name: Albani, Thomas My license renewal date for the state of Florida is February 28, 2019. IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek's customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. i .�% , A �� C • S • 9iji �i 0 9380 0% STAT OF •:�44/ 00 AL►��ol ,11111► Thomas A. Marl PE No.39380 Mrrek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 Albani, Thomas 1 of 1 Job Truss Truss Type Oty Ply T13090216 1326607 T01 GABLE 1 1 Job Reference (optional) Builders FirstSource, Plant City, FL 33566 10-0-0 , 13-3-9 46 = 8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Jan 30 09:33:57 2018 3-3-9 6.8-7 2-0-0 ' Scale=1:38.8 3x6 - 5x8 = 3x6 Plate Offsets MY)-- [2:0-3-14,0-1-8], [6:0-3-14,0-1-8], [8:0-4-0,0-3-4] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.72 Vert(LL) -0.17 6-8 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.74 Vert(CT) -0.37 6-8 >648 240 BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(CT) 0.04 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-SH Weight: 991b FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 3-11-8 oc purlins. BOT CHORD 2x4 SP No.1 BOT CHORD Rigid ceiling directly applied or 5-10-15 oc bracing. WEBS 2x4 SP No.2 OTHERS 2x4 SP No.2 REACTIONS. (lb/size) 2=848/0-3-8, 6=848/0-3-8 Max Horz 2=-73(LC 17) Max Uplift 2=-458(LC 8), 6= 458(LC 9) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1538/1310, 3-4=-1193/999, 4-5— 1193/999, 5-6=-1538/1310 BOT CHORD 2-8=-1069/1404, 6-8=-1096/1404 WEBS 4-8=-476/629, 5-8= 381/511, 3-8=-381/512 NOTES- (9) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any, other members. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 458 lb uplift at joint 2 and 458 lb uplift at joint 6. 9) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Alban[ PE No.39360 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 A WARNING • Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE M11--7473 rev, 10/032015 BEFORE USE. Design valid for use only with MiTek® connectors. fits design Is based only upon parameters shown, and Is for an Individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall bdiding design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek` Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, dellvery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Cdtetla, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Insfltute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type r. , Qty Ply T13090217 1325607 T02 Common. 3 1 Job Reference (optional) Builders FirstSource, Plant City, FL 33566 8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Jan 30 09:33:58 2018 Page 1 I D:bLvnVevTcFU HsW TxbgSrc2zxOb9-9MI79eUxD7gw1 IhOTI MKBmbpRXy7yfFJSaGneOzgCaN 2-0-0 6-8-7 10-0-0 13-3-9 20-0-0 22-0-0 2-0-0 .6-8-7 3-3-9 3-3-9 6-8-7 2-0-0 4x6 = 01 3x6 sxe 5x8 = LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ` BCDL 10.0 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TP12014 REACTIONS. (lb/size) 2=848/0-3-8, 6=848/0-3-8 Max Horz 2=-73(LC 13) Max Uplift 2=-458(LC 8), 6=-458(LC 9) Scale = 1:38.8 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TC 0.72 Vert(LL) -0.17 6-8 >999 360 MT20 244/190 BC 0.74 Vert(CT) -0.37 6-8 >647 240 WE, 0.24 Horz(CT) 0.04 , 6 n/a n/a Matrix-SH Weight: 84 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing, directly applied or 3-11-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 5-10-15 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1538/1310, 3-4=-1193/1000, 4-5=-1193/999, 5-6=-1538/1309 BOT CHORD 2-8=-1069/1404, 6-8=-1096/1404 WEBS 4-8=-475/629, 5-8= 381/511, 3-8=-381/511 NOTES- (6) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 458 lb uplift at joint 2 and 458 lb uplift at joint 6. 6) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 A WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev, 10/03,2015 BEFORE USF_ Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Addiflonal temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the 6904 Parke East Blvd. fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSIITPI I Quality Criteria, DSB-89 and BCSI Building Component Tampa, FL 33610 Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Mexandrla, VA 22314, Job Truss Truss Type City Ply ti T13090218 1325607 T03 GABLE 1 1 Job Reference (optional) BWItlers FlrstSource, Plant Glty, FL 33566 8.130 S Sep 15 201 / MI I eK Inaustrles, Inc. I ue Jan 30 u9:33:b9 z018 Page 1 ID:bLvnVevTcFU HsW TxbgSre2zxOb9-dYsVMzVZ_QyneSGC1?tZg_83exRSh84ShEOLASzgCaM -2-0-0 10-0.0 20-0-0 22-0-0 2-0-0 10-0-0 10-0-0 N �1 4x6 = 3x4 = 18 17 16 15 14 13 12 3x4 = 5x6 = Scale=1:38.8 N Im 0 20-0-0 20-0-0 Plate Offsets (X,Y)-- 12:0-2-0,Ed el, 110:0-2-0,Edge], j15:0-3-0,0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.44 Vert(LL) -0.02 11 n/r ' 120 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.16 Vert(CT) -0.02 11 n/r 120 BCLL 0.0 Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 10 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-SH Weight: 88lb FT=.20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.2 Press. Treated BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2x4 SP No.3 REACTIONS. All bearings 20-0-0. (lb) - Max Harz 2=-73(LC 13) Max Uplift All uplift 100 lb or less at joint(s) 16, 17, 14, 13 except 2=-228(LC 8), 18=-126(LC 12), 12=-126(LC 13), 10=-239(LC 9) Max Grav All reactions 250 lb or less at joint(s) 15, 16, 17, 18, 14, 13, 12 except 2=270(LC 1), 10=270(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- (11) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.0psf; h=12ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C.Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) All plates are 2x4 MT20 unless otherwise indicated. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-0-0 oc. 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 8) ` This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) Lumber designated with a "P" is pressure -treated with preservatives. Plate lateral resistance values have been reduced 20% where used in this lumber. Plates should be protected from corrosion per the recommendation of the treatment company. Borate or other suitable treatment may be used if it does not corrode the plates. If ACQ, CBA, or CA-B treated lumber is used, improved corrosion protection is required, and G185 galvanized plates may be used with this design. Incising factors have not been considered for this design. Building designer to verify suitability of this product for its Intended use. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 16, 17, 14, 13 except Gt=lb) 2=228, 18=126, 12=126, 10=239. 11) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building Is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Albani PE No.39360 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 A WARNING - Verify design paremeters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE 11411.7473 rev. 10/03MIS BEFORE USE. ° Design valid for use only with Mffek® connectors. This design Is based only upon parameters shown, and Is for on Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall building design. Bracing indicated Is 10 prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSE-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available.from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type A city Ply T13090219 1325607 T04 Scissor 8 1 Job Reference (optional) Builders FirstSource, Plant City, FL 33566 8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Jan 30 09:34:00 2018 Page 1 ID:bLvnVevTcFUHsWTxbgSrc2zxOb9-5lQtZJWClk4eGcrPbjOoDBh61 LcIQVPcvuluivzgCaL 2-0-0 7-3-15 10-0-0 12-8-1 20-0-0 22-0-0 2-0-0 7-3-15 2-8-1 2-8-1 7-3-15 2-0-0 4x6 = 1.5x8 STP= 2.00 12 4x6 = — 4x6 10-0-0 10-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) -0.28 6-8 >826 360 TCDL 7.0 Lumber DOL 1.25 BC 0.79 Vert(CT) -0.62 6-8 >374 240 BCLL 0.0 * Rep Stress Incr YES WB 0.45 Horz(CT) 0.19 6 n/a n/a BCDL 10.0 Code FBC2017/I-PI2014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.1 WEBS 2x4 SP No.3 REACTIONS. (lb/size) 2=844/0-8-0, 6=844/0-8-0 Max Horz 2=73(LC 12) Max Uplift 2=-465(LC 8), 6=-465(LC 9) FORCES. (Ib) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-2483/2004, 3-4=-2012/1517, 4-5=-2013/1521, 5-6=-2483/2034 BOT CHORD 2-8=-1741/2326, 6-8=-1792/2326 WEBS 4-8=-859/1188, 5-8=-457/635, 3-8=-457/638 Scale = 1:39.4 PLATES GRIP MT20 244/190 Weight: 79 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 4-5-6 oc bracing. NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2, 6 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=465, 6=465. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any, particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." . Thomas A. Albani PE No.39360 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MIP7473 rev. 10/03/2015 BEFORE USE Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component. not � a truss system. Before use, the building designer must vedfy the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and muss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandria, VA22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13090220 1325607 Vol Valley 1 1 'Job Reference (optional) Builders FirstSource, Plant City, FL 33566 8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Jan 30 09:34:00 2018 Page 1 ID:bLvnVevTcFUHsW TxbgSrc2zxOb9-51QtZJWClk4eGcrPbjOoDBhKULnjOeTcvuluivzgCaL 2-0-0 _ 4-0-0 2-0-0 2-0-0 Scale =1:7.4 4.00 Fl2 2x4 -�-- 2x4 0- 2 4-0-0 0-0- 2 3-11-4 Plate Offsets (X Y)-- [2:0-2-0 Edge] LOADING (psf) SPACING- 2-0-0 CSL DEFL. in (loc) Well Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TO 0.05 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.09 Vert(CT) n/a n/a 999 BOLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-P Weight: 9 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc puffins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (lb/size) 1=7813-10-8, 3=78/3-10-8 Max Horz 1=7(LC 12) Max Uplift 1=-33(LC 8), 3=-33(LC 9) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing- 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0•tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at Joint(s) 1, 3. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 A WARNING - VerW design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE MII--7473 rev. 1010312015 BEFORE USE. ' Design valld for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent tracing MiTek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Mexandrla, VA 22314. Tampa, FL 33610 Job Truss Truss Type city Ply • T13090221 1325607 V02 Valley 1 1 , Job Reference (optional) Builders Firs[Source, Piani GIry, FL 33566 a. I3v b Jep I v Gv I I IVII I eM IIIUWII Ieb, II— I uu val I ov vu.—v I — 10 raye I ID:bLvnVevTcFUHsWTxbgSrc2zxOb9-Zx_FnfxgW2CVulQb9Qv1 mPDUB16j92al8YVRELzgCaK 4-0-0 B-0-0 4-0-0 4-0-0 Scale = 1:14.6 V 0 0 2 2x4 4.00 12 4 46 = 2x4 11 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.12 Vert(LL) n/a n/a 999 TCDL 7.0 Lumber DOL 1.25 BC 0.17 Vert(CT) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(CT) 0.00 • 3 rVa n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-SH LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 1=96/7-10-8, 3=96/7-10-8, 4=262/7-10-8 Max Harz 1=-19(LC 17) Max Uplift 1=-49(LC 8), 3= 51(LC 13), 4=-95(LC 8) Max Grav 1=100(LC 23), 3=100(LC 24), 4=262(LC 1), FORCES. (lb) -Max. Comp./Max. Teri. -All forces 250 (lb) or less except when shown. 2x4 PLATES GRIP - MT20 244/190 Weight: 22 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3, 4. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 ® WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE MIh7473 rev. 1010312015 BEFORE USE. ° Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek° Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Informanon available from Truss Plate Institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13090222 1325607 V03 Valley 1 1 Job Reference (optional) Builders FirstSource, Plant City, FL 33566 6-0-0 8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Jan 30 09:34:02 2018 Page 1 I D:bLvnVevTcFUHsW TxbgSrc2zxOb9-27Yd_?YSHLKMVv_ni8QGlcmb_90iuVIuNCE?nnzgCaJ Scale=1:19.0 46 = a �o 0 4 3x4 % 2x4 I) 3x4 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.30 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.44 Vert(CT) n/a n/a 999 BCLL 0.0 ' Rep Stress incr YES WB 0.11 Horz(CT) 0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix-SH Weight: 36 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.3 BOT CHORD OTHERS 2x4 SP No.3 REACTIONS. (lb/size) 1=158/11-10-8, 3=158/11-10-8, 4=433/11-10-8 Max Harz 1=-31(LC 17) Max Uplift 1=-81(LC 8), 3=-84(LC 13), 4=-157(LC 8) Max Grav 1=165(LC 23), 3=165(LC 24), 4=433(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-4=-273/361 Structural wood sheathing directly applied or 6-0-0 oc purlins. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; VUlt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3 except (jt=lb) 4=157. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Alban! PE No.39380 M!Tek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 ® WARNING- Verity design parameters and READ NOTES ON THIS AND INCLUDED MIIEK REFERANCE PAGE AM-7473 rev. 10/032015 BEFORE USE Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not � a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication. storage, delivery, erection and bracing of trusses and truss systems, seeANSI/wiI Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate institute, 218 N. Lee Street, Suite 312, Alexandria, VA 22314. Tampa, FL 33610 Job Truss Truss Type Qty Ply T13090223 1325607 VO4 Valley 1 1 Job Reference (optional) Builders FirstSource, Plant City, FL 33566 8.13o s bep lb 2u1 i MI Tek Industries, Inc. I ue uan su ua:34:03 2ui a rage I ID:bLvnVevTcFUHsWTxbgSrc2zxOb9-W K60CLY42fSD73Z_GrxVrgJn4Yovdya2cs_YJEzgCal 5-9-8 8-0-0 10-2-8 16-0-0 5-9-8 2-2-8 2-2-8 5-9-8 a 0 0 3x4 = 3x4 % 7 6 3x4 2x4 11 2x4 11 Scale=1:25.5 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/fP12014 CSL TC 0.22 BC 0.19 WB 0.11 Matrix-SH DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/defl L/d n/a n/a 999 n/a n/a 999 0.00 5 n/a n/a PLATES GRIP MT20 244/190 Weight: 50lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puffins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 15-10-8. (lb) - Max Horz 1— 43(LC 17) Max Uplift All uplift 100 lb or less atjoint(s) 1, 5 except 7=-187(LC 12), 6=-186(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=367(LC 23), 6=367(LC 24) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. WEBS 2-7=-254/355, 4-6= 254/355 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=12,4mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(?) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s)1, 5 except (jt=lb) 7=187, 6=1.86. 7) 'This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." Thomas A. Alban! PE No.39360 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 ® WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERANCE PAGE Mll-7473 rev. f0IMO15 BEFORE USE ' Design valid for use only with MlTek8 connectors. This design is based only upon parameters shown, and Is for an Individual building component not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bracing Indicated Is to buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek° prevent Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSI/TPII Quality Criteria, DSB-89 and BCSI Building Component 6904.Parke East Blvd. Tampa, FL 33610 Safety Information available from Truss Plate institute, 218 N. Lee Street Suite 312, Alexandria, VA 22314. Job Truss Truss Type . Oty Ply T13090224 1325607 V05 Valley 1 1 Job Reference (optional) Builders FirstSource, Plant City, FL 33566 8.130 s Sep 15 2017 MiTek Industries, Inc. Tue Jan 30 09:34:03 2018 Page 1 I D:bLvnVevTcFUHs W TxbgSrc2zxOb9-W K60CLY42fSD73Z_GrxVrgJm EYmOdyM2cs_YJ EzgCal 5-9-8 10-0-0 14-2-8 20.0-0 5-9-8 4-2-8 4-2-8 5-9-8 Scale: 3/8"=1' Y 0 a 4x6 = 3x4 8 7 6 3x4 2x4 11 5x6 = 2x4 11 03112 15-9-8 14-2-8 20-0-0 0- -12 5-8-12 8-5-0 5-9-8 Plate Offsets (X,Y)-- [7:0-3-0,0-3-01 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.27 Vert(LL) n/a n/a 999 MT20 244/190 TCDL 7.0 'Lumber DOL 1.25 BC 0.28 Vert(CT) n/a n/a 999 BCLL 0.0 Rep Stress Incr YES WB 0.12 Horz(CT) 0.00 5 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix-SH Weight: 66lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pullins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 REACTIONS. All bearings 19-10-8. (lb) - Max Harz 1=55(LC 16) Max Uplift All uplift 100 lb or less atjoint(s) 1, 5, 7 except 8=-225(LC 12), 6— 225(LC 13) Max Grav All reactions 250 lb or less at joint(s) 1, 5 except 7=261(LC 1), 8=404(LC 23), 6=404(LC 24) FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-8=-289/401, 4-6= 289/401 NOTES- (7) 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=3.Opsf; h=12ft; Cat. II; Exp C; Encl., GCpi=0.18; MW FRS (envelope) and C-C Exterior(2) zone;C-C for members and forces & MW FRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Gable requires continuous bottom chord bearing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide. Will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 5, 7 except (jt=1b) 8=225, 6=225. 7) "This manufactured product is designed as an individual building component. The suitability and use of this component for any particular building is the responsibility of the building designer per ANSI TPI 1 as referenced by the building code." ti Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: January 30,2018 A WARNING- Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEKREFERANCE PAGE Mll-7473 rev. t e/ll3/2l1/5 BEFORE USE. Design valid for use only with MITekO connectors. Pis design is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, The building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent buckling of lndlvidual truss web and/or chord members only. Additional temporary and permanent bracing MiTek" Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, seeANSi/TPI I Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 218 N. Lee Street, Suite 312. Alexandrla, VA 22314. Tampa, FL 33610 Symbols PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. Dimensions are in ft-in-sixteenths. J�Apply plates to both sides of truss and fully embed teeth. 0-'/19, For 4 x 2 orientation, locate plates 0-1hd' from outside edge of truss. This symbol indicates the required direction of slots in connector plates. "Plate location details available in MiTek 20/20 software or upon request. PLATE SIZE The first dimension is the plate 4 x 4 width measured perpendicular to slots. Second dimension is the length parallel to slots. LATERAL BRACING LOCATION I N, Indicated by symbol shown and/or by text in the bracing section of the output. Use T or I bracing if indicated. Indicates location where bearings (supports) occur. Icons vary but reaction section indicates joint number where bearings occur. Min size shown is for crushing only. Industry Standards: ANSI/TPI1: National Design Specification for Metal Plate Connected Wood Truss Construction.. DSB-89: Design Standard for Bracing. BCSI: Building Component Safety Information, Guide to Good Practice for Handling, Installing & Bracing of Metal Plate ' Connected Wood Trusses. Numbering System 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) I 2 3 TOP CHORDS 0 c O U a- OO JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. PRODUCT CODE APPROVALS ICC-ES Reports: ESR-1311, ESR-1352, ESR1988 ER-3907, ESR-2362, ESR-1397, ESR-3282 ® General Safety Notes Failure to Follow Could Cause Property Damage or Personal Injury 1. Additional stability bracing for truss system, e.g. diagonal or X-bracing, is always required. See BCSI. 2. Truss bracing must be designed by an engineer. For wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I Q bracing should be considered. c O 3. Never exceed the design loading shown and never = U stack materials on inadequately braced trusses. , d O 4. Provide copies of this truss design to the building designer, erection supervisor, property owner and all other interested parties. 5. Cut members to bear tightly against each other. 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint locations are regulated by ANSI/TPI 1, 7. Design assumes trusses will be suitably protected from the environment in accord with ANSI/TPI 1. 8. Unless otherwise noted, moisture content of lumber shall not exceed 1 W. at time of fabrication. 9. Unless expressly noted, this design is not applicable for use with fire retardant, preservative treated, or green lumber. 10. Comber is a non-structural consideration and is the responsibility of truss fabricator. General practice is to camber for dead load deflection. 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that Trusses are designed for wind loads in the plane of the specified. truss unless otherwise shown. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. Lumber design values are in accordance with ANSI/TPI 1 section 6.3 These truss designs rely on lumber values established by others. © 2012 MiTek® All Rights Reserved MiTek Engineering Reference Sheet: Mll-7473 rev. 10/03/2015 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior approval of an engineer. 17. Install and load vertically unless Indicated otherwise. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. 19. Review all portions of this design (front back words and pictures) before use. Reviewing pictures alone is not sufficient. 20. Design assumes manufacture in accordance with ANSI/TPI 1 Quality Criteria.