HomeMy WebLinkAbout0512-0637 INSPECTION RESULTS FORM 8-18-0608/17/2006 09:04 77256 WEINTRAUB ORG. PAGE 02
SCE E
tiF ivarZaLy IV
AUG1S2
:PHONE #:772-807-9335 FAX #: 772-343-0585
D ,
ST LUCIE COUNTY
•PRJVATE PR0VIDER INS.PECTIO.NRESULTS FOR,
ATT: BILL LOGSDON 772-462-6443
DATE OF YNSPECTION: I AR �
DATE Off' REQUEST: � ���A��
NAME OF HOME )BUILDER: a�rrx�q�K� C ,__ SUBDMSJON.7-71:7 1Z &A L
PERMIT #: SLC - wiffilL4_111 CONFIRM #: (4 a
ADDRESS OF INSPECTION: �b 5 i S us I
RESULTS: 1 i
o 'lease CIRCLE each type of permit.-
SEWER CONNECTION
PLUMBING ROUGH -IN
TEMPORY TOILETICULVERT
FOOTING/FOUNDATION
SLAB
TERMITE SPRAY (CHECK AT FOOTER)
EVER GROUND
TIER BEAM
BOND BEAM
COLUMNS
STRUCTURAL UP -LIFT
WINDOW BOOR SUCKS
ROOF SHEATHING
WALL SHEATHING
STRAPPING
MULLION
0
1
1
2
2
2
2
3
3
3
4
4
4
4
4
5
425
420
427
110
115
121
103
125
128
118
145
133
134
135
137
127'
ROOF DRY -IN FLASHING
5
136
ELECTRIC ROUGH
5
239
A1C ROUGH
5
351
PLUMBING TOP -OUT
5
424
FRAMING
5
140
(OR USE) FRAME ALL 6 860
WINbOW ATTACHMENT 5 148
WALL INSULATION 6 141
ROOF FINAL 6 167
PRE -POWER (30 DAY)
7
260
ADDRESS FINAL
7
800
WIRE LATH
7
139
HURRICANE PANELS ( SHUTTERS)
8
172
BUILDINGIDRIVEWAY
8
$04
LANDSCAPEITREES 8
FINAL 8
COMMERCIAL (ADDITIONAL INSPECTION
NEEDED)
ALARM SYSTEM ROUGH
GAS ROUGH
FIRE WALL
IRRIGATION SYSTEM
FINAL ELECTRIC
FINAL MECHANICAL
FINAL PLUMBING
• •••••-•----FINAL-ALARM SYSTEM _.... _.—_.._
HANDICAP RESTROOMS
GAS FINAL
***NOTES.
808
999
241
490
179
456
280
380
480
-261
165
493
*CUT OFF TIME FOR FOLLOWING
)DAYINSPECTIOM I'S 4: 00 pm
08/17/2006 09:04 77256C"'=1
TWO Work lnspecti on 124597 �
WEINTRAUB ORG.
r`
PAGE 03
Page l o•F 3
WEH�..
................... .
Windows/Door
Bucks/Wall
Sheathing
[fD=924597] R�
,,:���::r;;l;�r:,•::�ar.m,r14;�'i;,..,.,._„��.����r�eiir�:.,• :ao�;)°II II; ."°I11'a'il'r•: ^�ia:n:nC�'j'!:°,�
Zdhil 1 I u11�ll l lia I4 ,I'I'k":`:.i;li
Re -inspection
Date: 8116/2006
Inspector: Redden, Dwain
Client: Indian River National Barr Time of Inspection;
Caller Name: JIM Location
Phone: Lot: 0
Subdivision: St. Lucie County
Project No.: 05001 Address: 8351 S. U.S_ #1
Billing Group No.: 0026
WOM
Purchase Orders
from Lot: none from Lot -Specific: none from Inspection: Prefix: V
Permit No. 05-120637 Confirmation No: 626
Model:
Elevation: FoundationType: Unknown
Reference Number:
Overall Results
Completed on 8/16/2006 1:02:53 PM
Pass Fail
n . u
Accepted Reinspect Required
as
Noted Item #(s) of Failed Itern(s)
htin-//69 15 179 1 ail/WPhgkPri/TnsnertnrTNTHF.oiTiice/weh-,ked4itrn-ItnCmuiEditIO.asD 8/17/2006
08/17/2006 09:04 772561` -JEI WEINTRAUB ORG. PAGE_ 04
TWO Work inspection 12455i`. �` Page 2 of 3
d
Inspection Punchllst: 10 Items
1. Deady for Inspection
Refer to
Item DEescription Off Pass Fail NlA Comments
FT]Required Documents On Site.
Building configuration matches approved plan
2. Buildina
Item Description Off
® Window & door installation
I � I Design speed specifications (PSF) (f
F761r=mergenay egress CJ
Pass
C�)
Fail
NIA
®
C=
Refer to
Comments
❑
0
❑
L�]Vedfy tempered labeling
Glass black installation
=Verify termite treatment (Borg/care) C.")
❑
=
=
General Comments
MID MORNING BATHROOM WINDOWS AND FRONT ENTRY NOT INSTALLED. SUPT. DID NOT
KNOW EXACTLY WHAT TIME INSTALLERS WOULD ARRIVE.
No Field Sketch