Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
MANNED' FORM R405-2017 �BY ude County FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING C Florida Department of Business and Professional Regulation - Residential A �RUC TI�ON Project Name: SLAY RESIDENCE Builder Name: TREFELNER CONSTRUCTION Street: 120 BERGER ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34945 Permit Number: Owner: BEAU AND KATIE SLAY Jurisdiction: Design Location: FL, Fort Pierce County:: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1997.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1997.30 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 10. Ceiling Types (1855.0 sqft.) Insulation Area 5. Is this a worst case? No a. Roof Deck (Unvented) R=20.0 1855.00 ft2 6. Conditioned floor area above grade (ft2) 1855 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 ;.a. Windows(318.0 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 140 a. U-Factor: Dbl, U=0.32 300.00 ft2 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.28 18.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.23 a. Central Unit 29.4 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: ' Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.221 14. Hot water systems a. Electric Cap: 40 gallons 8. Floor Types (1855.0 sqft.) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 1855.00 ft2 b. Conservation features b. N/A R= ft2 None c. WA R= ft2 15. Credits None Total Proposed Modified Loads: 63.21 Glass/Floor Area: 0.171 PASS Total Baseline Loads: 68.04 I hereby certify that the plans and specifications covered by Review of the plans and I'kYE ST.q?� this calculation are in compliance with the Florida Energy specifications covered by.this Code. calculation indicates compliance PREPARE B with the Florida Energy Code. rrnrr''%-� - =f' :��� �� : Before construction is completed DATE. - this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as is in compliance Florida Statutes. 7ed, C with the Florida Energy de. OWNER/AG NT `' BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (11402.4.1.2). 1/24/2018 11:14 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software File COPY Page 1 of 6 Ft7RM R405-9017 • PROJECT Title: SLAY RESIDENCE Bedrooms: 3 Address Type: Street Address Building Types User Conditioned Area: 1855 Lot # Owner Name: BEAU AND KATIE SLAY Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: TREFELNER CONSTRUCTI Rotate Angle: 0 Street: 120 BERGER ROAD Permit Office: ST LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, 34945 New/Epsting: New (From Plans) Comment: CLIMATE V Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1855 17437 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 276 2594.4 No 0 1 1 Yes Yes Yes 2 M BATH 102 958.8 No 0 1 Yes Yes Yes 3• M WIC 54 507.6 No 0 1 Yes Yes Yes 4 LAUNDRY 112 1052.8 No 0 1 Yes Yes Yes 5. POWDER ROOM 42 394.8 No 0 1 Yes Yes Yes 6 HALLWAY 68 639.2 No 0 1 Yes Yes Yes 7 KITCHEN 180 1692 Yes 0 1 Yes Yes Yes 8 PANTRY 70 658 No 0 1 Yes Yes Yes 9 DINING ROOM 182 1710.8 No 0 1 Yes Yes Yes 10 FOYER 63 592.2 No 0 1 Yes Yes Yes 11 LIVING ROOM 225 2115 No 0 1 Yes Yes Yes 12 CLST 3 14 131.6 No 0 1 Yes Yes Yes 13 BEDROOM 3 168 1579.2 No 0 1 1 Yes Yes Yes 14 BATH 3 50 470 No 0 1 Yes Yes Yes 15 BATH 2 50 470 No 0 1 Yes Yes Yes 16 BEDROOM 2 139 1306.6 No 0 1 1 Yes Yes Yes 17 CLST 2 18 169.2 No 0 1 Yes Yes Yes 18 HALL 42 394.8 No 0 1 Yes Yes Yes 1/24/2018 11:14 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 FLOORS- # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 40 ft 0 276 ftz 1 0 0 2 Slab -On -Grade Edge Insulation M BATH 12 ft 0 102 ft2 ____ 1 0 0 3 Slab -On -Grade Edge Insulation M W IC 1 ft 0 54 ft2 _-__ 1 0 0 4 Slab -On -Grade Edge Insulation LAUNDRY 20 ft 0 112 ft2 ____ 1 0 0 5 Slab -On -Grade Edge Insulation POWDER ROOM 7 ft 0 42 ft2 ____ 1 0 0 6 Slab -On -Grade Edge Insulation HALLWAY 1 ft 0 68 ft2 1 0 0 7 Slab -On -Grade Edge Insulation KITCHEN 12 ft 0 180 ft2 1 0 0 8 Slab -On -Grade Edge Insulation PANTRY 7 ft 0 70 ft2 __-_ 1 0 0 9 Slab -On -Grade Edge Insulation DINING ROOM 18 ft 0 182 ft2 ____ 1 0 0 10SIab-On-Grade Edge Insulation FOYER 7 ft 0 63 ft2 1 0 0 11SIab-On-Grade Edge Insulation LIVING ROOM 15 ft 0 225 ft2 ____ 1 0 0 12SIab-On-Grade Edge Insulation CLST 3 9 ft 0 14 ft2 ____ 1 0 0 13SIab-On-Grade Edge Insulation BEDROOM 3 26 ft 0 168 ft2 ____ 1 0 0 14SIab-On-Grade Edge Insulation BATH 3 5 ft 0 50 ft2 ____ 1 0 0 15SIab-On-Grade Edge Insulation BATH 2 5 ft 0 50 ft2 ____ 1 0 0 16SIab-On-Grade Edge Insulation BEDROOM 2 24 ft 0 139 ft2 1 0 0 17SIab-On-Grade Edge Insulation CLST 2 7 ft 0 18 ftz 1 0 0 18SIab-On-Grade Edge Insulation HALL 1 ft 0 42 ft2 ____ 1 0 0 ROOF J Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Metal 2075 ft2 0 ft2 Light 0.6 No 0.9 No 20 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1855 ft2 N N 1/24/2018 11:14 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 , ' CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 ' Under Attic (Unvented) MASTER BEDRO 20 Blown 276 ft2 0.1 Wood 2 Under Attic (Unvented) M BATH 20 Blown 102 ft2 0.1 Wood 3 Under Attic (Unvented) M WIC 20 Blown 54ft2 0.1 Wood 4 Under Attic (Unvented) LAUNDRY 20 Blown 112 ft2 0.1 Wood 5 Under Attic (Unvented) POWDER ROOM 20 Blown 42 ft2 0.1 Wood 6 Under Attic (Unvented) HALLWAY 20 Blown 68 ft2 0.1 Wood 7 Under Attic (Unvented) KITCHEN 20 Blown 180 ft2 0.1 Wood 8 Under Attic (Unvented) PANTRY 20 Blown 70 ft2 0.1 Wood 9 Under Attic (Unvented) DINING ROOM 20 Blown 182ft2 0.1 Wood 10 Under Attic (Unvented) FOYER 20 Blown 63ft2 0.1 Wood 11 Under Attic (Unvented) LIVING ROOM 20 Blown 225 ft2 0.1 Wood 12 Under Attic (Unvented) CLST 3 20 Blown 14 ft2 0.1 Wood 13 Under Attic (Unvented) BEDROOM 3 20 Blown 168 ft2 0.1 Wood 14 Under Attic (Unvented) BATH 3 20 Blown 50 ft2 0.1 Wood 15 Under Attic (Unvented) BATH 2 20 Blown 50 ft2 0.1 Wood 16 Under Attic (Unvented) BEDROOM 2 20 Blown 139 ft2 0.1 Wood 17 Under Attic (Unvented) CLST 2 20 Blown 18 ft2 0.1 Wood 18 Under Attic (Unvented) HALL 20 Blown 42 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 N Exterior Concrete Block - Ext InstFAASTER BE 4.1 15 0 9 4 140.0 ft2 0 0 0.6 0 2 E Exterior Concrete Block - Ext InsWASTER BE 4.1 17 0 9 4 158.7 ft2 0 0 0.6 0 3 S Exterior Concrete Block - Ext InsLWIASTER BE 4.1 8 0 9 4 74.7 ft2 0 0 0.6 0 4 N Exterior Concrete Block - Ext Insul M BATH 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 5 N Exterior Concrete Block - Ext InsuILAUNDRY 4.1 10 0 9 4 93.3 ft2 0 0 0.6 0 6 W Exterior Concrete Block - Ext InsuILAUNDRY 4.1 10 0 9 4 93.3 ft2 0 0 0.6 0 7 W Exterior Concrete Block - Ext InsUPOW DER R 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 8 E Exterior Concrete Block - Ext Insul KITCHEN 4.1 12 0 9 4 112.0 ft2 0 0 0.6 0 9 W Exterior Concrete Block - Ext Insul PANTRY 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 10 S Exterior Concrete Block - Ext InstOINING ROO 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 11 W Exterior Concrete Block - Ext InsiDINING ROO 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 12 W Exterior Concrete Block - Ext Insul FOYER 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 13 E Exterior Concrete Block - Ext Insd11VING ROO 4.1 15 0 9 4 140.0 ft2 0 0 0.6 0 _ 14 N Exterior Concrete Block- Ext Insul CLST 3 4.1 7 0 9 4 65.3 ft2 0 0 0.6 0 15 E Exterior Concrete Block - Ext Insul CLST 3 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 16 N Exterior Concrete Block - Ext InsiBEDROOM 3 4.1 1 0 9 4 9.3 ft2 0 0 0.6 0 17 E Exterior Concrete Block - Ext InsiBEDROOM 3 4.1 11 0 9 4 102.7 ft2 0 0 0.6 0 18 S Exterior Concrete Block - Ext Ins8EDROOM 3 4.1 14 0 9 4 130.7 ft2 0 0 0.6 0 19 S Exterior Concrete Block - Ext Insul BATH 3 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 20 S Exterior Concrete Block - Ext Insul BATH 2 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 _ 21 S Exterior Concrete Block - Ext InstSEDROOM 2 4.1 13 0 9 4 121.3 ft2 0 0 0.6 0 22 W Exterior Concrete Block - Ext InsMEDROOM 2 4.1 11 0 9 4 102.7 ft2 0 0 0.6 0 1/24/201811:14 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 23 N Exterior Concrete Block - Ext Insul CLST 2 4.1 5 0 9 4 46.7 ft2 0 0 0.6 0 24 W Exterior Concrete Block - Ext Insul CLST 2 4.1 2 0 9 4 18.7 ft2 0 0 0.6 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated LAUNDRY None .39 3 8 24 ft2 2 W Insulated FOYER None .39 3 8 24 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang • V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 E 2 Vinyl Low-E Double Yes 0.32 0.22 N 45.0 ft2 2 ft 0 in 1 ft 4 in None None 2 S 3 Vinyl Low-E Double Yes 0.32 0.22 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None 3 N 4 Vinyl Low-E Double Yes 0.28 0.23 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 4 W 7 Vinyl Low-E Double Yes 0.32 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 5 E 8 Vinyl Low-E Double Yes 0.32 0.22 N 24.0 ft2 2 ft 0 in 1 ft 4 in None None 6 W 11 Vinyl Low-E Double Yes 0.32 0.22 N 45.0 ft2 2 ft 0 in 1 ft 4 in None None 7 W 12 Vinyl Low-E Double Yes 0.32 0.22 N 16.0 ft2 2 ft 0 in 1 ft 4 in None None 8 E 13 Vinyl Low-E Double Yes 0.32 0.22 N 45.0 ft2 2 ft 0 in 1 ft 4 in None None 9 E 13 Vinyl Low-E Double Yes 0.32 0.22 N 40.0 ft2 2 ft 0 in 1 ft 4 in None None T 10 E 17 Vinyl Low-E Double Yes 0.32 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None 11 S 19 Vinyl Low-E Double Yes 0.28 0.23 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None 12 S 20 Vinyl Low-E Double Yes 0.28 0.23 N 6.0 ft2 2 ft 0 in 1 ft 4 in None None ' 13 W 22 Vinyl Low-E Double Yes 0.32 0.22 N 15.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000418 2034.3 111.68 210.03 .3052 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 27 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split SEER: 16 29.4 kBtu/hr 882 cfm 0.8 1 sys#1 • 1/24/2018 11:14 AM EnergyGaugeB USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 6 FORM R40.5-2017 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Exterior 0.98 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS V — Supply — — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 140 ft2 Attic 14 ft2 Default Leakage Attic (Default) c(Default) c 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Cooling Jan Feb Mar Apr May Jun Jul AugSep Oct Nov Dec Heat Jan Feb Mar Apr May Jun Jul Auge Oct Nov Dec Venting Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (W D) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Heating (W D) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 . 1/24/2018 11:14 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 6 of 6 2017 -AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: SLAY RESIDENCE Builder Name: TREFELNER CONSTRUCTION Street: 120 BERGER ROAD Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE, FL, 34945 Permit Number: Owner: BEAU AND KATIE SLAY Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. . requirements Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with the The insulation in any dropped ceiling/soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls shall The junction of the top plate and the top of exterior walls shall be sealed. be insulated by completely filling the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered floors) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind bh)Ina and wirin . Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Electrical/phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover plates and walls or ceilings. a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1/24/201811:15 AM EnergyGauge® USA - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017- ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 93 The lower the EnergyPerformance Index, the more efficient the home. 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conddioned floor area (ft2) .7. Windows- Description a. U-Factor: Dbl, U=0.32 SHGC: SHGC=0.22 b. U-Factor: Dbl, U=0.28 SHGC: SHGC=0.23 c. U-Factor: N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 120 BERGER ROAD, FORT PIERCE, FL, 34945 New (From Plans) 9. Wall Types Single-family a. Concrete Block - Ext Insul, Exterior b. N/A 1 c. N/A 3 d. N/A 10. Ceiling Types No a. Roof Deck (Unvented) 1855 b. N/A Area c. N/A 300.00 ft2 11. Ducts a. Sup: Attic, Ret: Attic, AH: Attic 18.00 ft2 12. Cooling systems ft2 a. Central Unit ft2 2.000 ft. 0.221 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 1856.00 ft2 b. N/A R= ft2 c. N/A R= ft2 13. Heating systems a. Electric Strip Heat 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card Will be completed based on installed Code compliant f res. Builder Signature: Date: /� Address of New Hom Z p � iGig* i ig City/FL Zip: ;i A 30ys Insulation Area R=4.1 1997.30 f:2 R= ft2 R= ftz R= ft2 Insulation Area R=20.0 1855.00 ft2 R= ft2 R= ft2 R ft2 6 140 kBtu/hr Efficiency 29.4 SEER:16.00 kBtu/hr Efficiency 27.0 COP:1.00 Cap: 40 gallons EF: 0.98 None *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupport@energygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 1/24/2018 11:14 AM EnergyGauge@) USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 ect Su mmary umma Job: -�- wrightso'ft� � � Date: Jan 24, 2018 Entire House By: QUICK CALCS, INC. ° 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@!AOL.COM Project• • For: SLAY RESIDENCE, TREFELNER CONSTRUCTION 120 BERGER ROAD, FORT PIERCE, FL 34945 Notes: Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 23018 Btuh Structure 22395 Btuh Ducts 4693 Btuh Ducts 0 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 27711 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 21275 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3402 Btuh Ducts 1769 Btuh Heating Cooling Central vent 0 cfm) 0 Btuh Area (ft2) 1855 1855 Equipment latent load 5172 Btuh Volume (ft3) 17252 17252 Air changes✓hour 0.38 0.20 Equipment total load 26446 Btuh Equiv. AVF (cfm) 109 58 Req. total capacity at 0.70 SHR 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR4031 L1 AHRI ref Coil TEM6AOC36H31++TDR AHRI ref 7567544 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 8.0 kW Sensible cooling 20580 Btuh Heating output 27258 Btuh Latent cooling 8820 Btuh Temperature rise 25 OF Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.035 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.81 Calculations approved by AC CA to meet all requirements of Manual J 8th Ed. wrightsoft° 2018-Jan-24 11:1 Right -Suite® Universal 2017 17.0.08 RSU08101 MCA E:\Documnets\Wrightsoft FNAC\SLAY RESIDENCE.rup Cale = MJ8 Front Door faces: W Paagege 1 �d- wrightsoft° Right-M Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIE tANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Entire House 214.0 ft 9.3 ft 1855.0 ft2 MASTER BEDROOM 40.0 ft 9.3 ft heat/cool 1.0 x 276.0 ft 276.0 ft2 Ty Construction number U-value (Btuh/ft{°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 ]�, 13A flocs glazv -- - 2 zing, clr low-e 11D0 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e glazing -clr low-e 13A-4ocs _ 2 glazing, clr low-e .2 glazing, clr IoW- ___ 13A4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11DO - - --- - 16A30md�_-_ - 0.143 0.280 0.390 0.143 0.320 0.320 0.320 0 143 0.280 _ __'_0.320 0.143 0.320 0.320 0.390 --- - ,. •=0,032 __ 1.358 n n n - 4.00 7.84 10.92 2,19 9.02 10.34 ^' 465 6 24 - - 435 0 24 -- -1742 47 262 1446 215 941 358 1654 94 -___.358 1662 672 143 --- - 262 __. - 1682 8137 �952 54 248 790 587 2599 1008 9C 4 108 _-- 376 908 1856 403 248 - - - 4455 0 v 140 0 158 0 45 -___ 0 74 0 - - 40 0 0 0 -- - - 0 276 --- 140 0 113 0 3 0 - 54 0 --- 40 0 0 0 0 - 559 0 0 247 0 1114 -0 75 0 ._ - 376 0 0 0 0 _0 a a a e _ _. s s -s_ w w w w - ..- _ - � 4.00 8.96 8.96 8.96 4.00 7.84 __8.96. 4.00 8.96 8.96 10.92 _ - 0_90 _- 38.02, 2.19 24.45 24.75 25.20 2.19 9.02 _ 9.41 2.19 24.75 25.20 10.34 , - 2.24 aw 530 24 105 _ 40 - 465 12 4d 361 4 15 _4_____ ' 413 24 _.. __SO 415 11 1 ---- 24 - 1855 -_Y- 214 453 0 403 0 138 0 ___ - 358 0 0 0 - 0 __ �P47 __- 1521 ���-_ _ V)/ _T 530 75 16 - 24 _w -_ 1865 1855 t��-GGp -- - _ - - - 276 __ 276 40 _- 6 c)AED excursion 0 -277 Envelope loss/gain 19656 15197 3679 2460 12 a) Infiltration b) Room ventilation 3362 0 948 0 628 0 177 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 6250 0 0 1500 Subtotal (lines 6 to 13) 23018 22395 4307 4137 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 120% 0% 0 0 0 23018 4693 0 0 0 22395 0 20% 0%1 0 0 6 4313 879 0 0 14 4151 0 11 Total room load Air required (cfm) 27711 9801 22395 980 5193 1841 4151 182 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. AA- wrightsOfrt, 2018-Jan-24 1 Right -Suite® Universal 2017 17.0.08 RSU08101 Page ae 1 E:\Documnets\WrightsoftHVACkSLAYRESIDENCE.rup Calc = MJ8 Front Door faces: W g + wrightsoft- Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM Job: Date: Jan 24, 2018 By: 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area M BATH 12.0 ft 9.3 ft heat/cool 1.0 x 102.0 ft 102.0 ft2 M WIC 0 ft 9.3 ft heat/cool 6.0 x 9.0 ft 54.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 -G l-D 13A4ocs ----- -- 2 glazing, clr low- , 11 D0 13A4ocs 2 glazing, clr low-e 2 glazing, cir low-e 13 cir low-e g 9 2 glazing, clr_low-e.-_ 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11D0 22 tPh- - --- - -- - - - 106 0 0 R 423 47 0 0 0 0 _-_--__. 0 ______O 0 0 0 0 - 456 - - - 231 54 0 0 0 0 _. __ 0 ____0 0 0 0 __. -__ 0 - - 0 - -_ O 0 0 0 0 0 - _ 0 +l0 0 0 0 _. 6 - -54 - _ ----0 0 0 _-- - _- 6 0 0 0 0 0 - _ .,.-0 0 0 0 0 _- 0 -- - 0 .------ O 0 0 0 0 0 -- - --0 0 0 0 0 0 - - - -0 -- 0.143 0.280 0:390 0.143 0.320 0.320 0.143 280 _` 0,320 0.143 0.320 0.320 0.390 - 1.358 -n n n a a a _ - s ,-s_ w w w w_ - _ 4.00 7.84 10.92 -2.19 9.02 10.34 ---- 1f 2 6 0 4.00 8.96 8.96 _ 4.60 8.96 4.00 8.96 8.96 10_92 38.02 2.19 24.45 24.75 22.10 -_ 9.41 2.19 24.75 25.20 10.34 --" _ 0.00 0 0 0 -_---._ ` 0 _ 0 0 0 0 _ _ 0 �-- ------ 102 0 0 0 - 0 ____-__-0 0 0 0 - _. 0 - - �2 0 0 0 ' - -�6 0 0 0 0 0 - - - --0 f--G L G F - 6 c)AED excursion -36 -8 Envelope loss/gain 1018 478 48 113 12 a) Infiltration b) Room ventilation 189 0 53 0 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 0 Subtotal (lines 6 to 13) 1206 531 48 113 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 1 20% 0% 0 0 0 1206 246 0 0 0 531 0 20% 0% 0 0 9 57 12 0 0 20 134 0 Total room load Air required (cfm) 1452 51 531 23 69 2 134 6 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. A ZK " WrightsOft' RightSuite@ Universal 2017 17.0.08 RSU08101 2018-Jan-24 1Pa0e 2 E:\Documnets%Wrightsoft HVACISLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W 9 -�- wrightsoft- Right-M Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name EWsed wall Room height Room dimensions Room area LAUNDRY 20.0 ft 9.3 ft heat/cool 1.0 x 112.0 ft 112.0 ft2 POWDER ROOM 7.0 ft 9.3 ft heat/cool 7.0 x 6.0 ft 42.0 ft2 Ty Construction number U-value (Btuh/W�-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P/S Heat Cool 6 11 - G 13A ocs' -- -!� 2 glazing, cir low-e _11D0-0.390 13AAocs 2 glazing, clr low-e - 2 glazing, clr low-e 2 glazinq._clr lower --_, 13AAocs 2 glazing, cir low-e 2 glazing, cir IoW_e__ 13AAocs 2 glazing, cir low-e 2 glazing, clr low-e 11D0 _ �___� _ 16A 30.md -_ 0 143 0.280 0.143 0.320 0.320 _ __--0 320 0143 0.280 _0.320 0.143 0.320 0.320 _---0.390 _- ; 0 032 n n n _ -e a a _e_- s s __a_,. w w w _ w ___ - 4.00 7.84 10r92 4.00' 8.96 8.96 8.96 -4.00 7.84 _____8.96. 4.00 8.96 8.96 ._ 10.92 w_ 0_90 -- 2.19 9.02 10.34 _ 2.19 24.45 24.75 25.20 2.19 0.02 _--9.41: 2.19 24.75 25.20 -10.34 _ _ 2.24 -----93 0 :._..___ 24 _ 0 0 0 0 _ 0 0 _ ._.-0 93 0 0 --- --- __ • 112 -- ` 69 0 __•., 24 0 0 0 _ _ _ 0 _ 0 0 .------0 93 0 0 Q _u _112 ' - 276 0 ___ 2(2 0 0 0 _0 0 0 _ - _ 0 372 0 0 _- . - -0 -� 100 J 1161 0 248 - 0 0 0 0 _ _ 0 0 _ 0 203 0 0 -- - 0 _ 25.1 --- 6 0 _-_ _ 0 p0 0 0 0 _�0 0 ' -- 0 0 __.._._ 0 0 0 0 0 0 0 50 1 0 -'-0 0 __ - 0 0 0 0 0 0 201 134 0 9 -- --'-'-0 0 w.-- 0 0 0 0 _.-_. .0 0 110 371 0 o VVVVVVjjjj��//// -_ _ _ V+1 ��GGp 65 15 0 ----� 42 - ---- _ _42 7 - �- 38 266----0 _ �_94 6 c)AED excursion -90 151 Envelope loss/gain 1772 763 639 726 12 a) Infiltration b) Room ventilation 314 0 89 0 110 0 31 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 500 0 0 0 Subtotal (lines 6 to 13) 2086 1352 749 757 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 6 2092 426 0 0 14 1365 0 20% 0% 0 0 6 755 154 0 0 14 771 0 Total room load Air required (cfm) 2518 89 1365 601 1 132 908 771 34 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. '0flwrightsoft• Right -Suite® Universal 2017 17.0.08 RSU08101 2018Jan-Jan11g Page 3 E:%Documnets%W6ghtsoft HVAC\SLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W -�- wrightsoft, Right-J® Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIEtANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772.466-6796 Email: QUICKCALCS ,AOL.COM 1 2 3 4 5 Room name EVosed wall Room height Room dimensions Room area HALLWAY 0 ft 9.3 ft heat/cool 1.0 x 68.0 ft 68.0 ft2 KITCHEN 12.0 ft 9.3 ft heat/cool 12.0 x 15.0 ft 180.0 ft2 Ty Construction number U-value (Btuh/ft2-°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ftz) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A�ocs 2 glazing, clr'low=e 1100 _ ' 13AAocs� - - 2 glazing, clr low-e 2 glazing, clr low-e 2 glazmg,_clr low e_.. 13A-4ocs 2 glazing, clr low-e 2.glazm9, clr lower_ 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 0143 0.280 0.390 n n '_ n 4.00 7:84 10.92 2.19 9.02 ' 10.34 0_--. 0 ' ' 0 - ~y 0 0 0 0 0 ^w0 0 0 0 0 _ .0 0 ' 0 -- - 0 0 0 0 0 __,--0 0 0 0 0 __ T__ 0 ----_9 0 0 0 --- 351 215 0 _-_ 0 _, 0 0 .__- _0. 0 0 0 --- � �__-161 --- - 456 -0- 0 _ _ 0 - - 192 587 0 ------- -0 0 0 0 0 0 --_-_- 3 403 - - ____.0 �- ------ 0 0 0 - ---- 0 0 0 0 0 0 _ _-- 0 0 0 0 ___61 _1i- - - --0 0 0 0 -- 0 0 0 ______0 0 0 ______0 0 0 0 _ -.._0 152 - -- 0 0 0 -~ 112 24 0 ____0_ 0 0 _,_-0 0 0 0 -_ --_0 _^__ 18 _ 180 0 0 ' 0 - 88 2 0 ___ 0 0 0 _ 0 0 0 0 8 _ 180 yyW _ 0.143 0.320 0.320 0 320 ^- 0143 0.280 , "-0 320 0.143 0.320 0.320 0.390 a a a a s s -sue w w w w 4.00 8.96 8.96 8.96 4.00 7.84 _ _ 8 98 4.00 8.96 8.96 10_92 - 2.19 24.45 24.75 25 20 219 9.02 ___ 9.41 2.19 24.75 25.20 _._10_f4 _.____ 2.24 ---0.00 -_ T _ --- __ 0.90 r__ 68 .____-_88 F 22ktph - -- - - _0.032 - - _ 1.358 - _e _ 38.02 �_. ---- --12 6 c)AED excursion -10 -110 Envelope loss/gain 61 143 1183 1071 12 a) Infiltration b) Room ventilation 0 0 0 0 189 0 53 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 1200 Subtotal (lines 6 to 13) 61 143 1372 2324 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 -61 0 0 0 0 -143 0 0 20% 0% 0 0 13 1385 282 0 0 31 2355 0 Total room load Air required (cfm) 0 0 0 0 1667 59 2355 103 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. A t A - wrightSOft' 2018Jan-24 1 Right -Suite® Universal 2017 17.0.08 RSU08101 Page ae 4 E:\Documnets\WdghtsoftHVAC\SLAYRESIDENCE.rup Calc = MJ8 Front Door faces: W g -�- wrightsoft. Right-l® Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS ,AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area PANTRY 7.0 ft 9.3 ft heat/cool 7.0 x 10.0 ft 70.0 ft2 DINING ROOM 18.0 ft 9.3 ft heat/cool 13.0 x 14.0 ft 182.0 ft2 Ty Construction number Ll-value (Btuhlft2-°F) Or HTM (Btuh/ft2) Area (ft) or perimeter (ft) Load (Btuh) Area (ft-) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-4ocs ` - - 2 glazing, clr low-e 13A�ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazinq,_clr low-e 13A-46cs 2 glazing, clr low-e .2 glazing,-clr lower;_- 13AAocs 2 glazing, cir low-e 2 glazing, clr low-e 11D0_ -- -------- "- ;0143 0.280 0390 - 0.143 0.320 0.320 _ 0.320 ;�. 0143 0.280 __0 320 0.143 0.320 0.320 _--0.390 1.358 nn n n 'e . a a e s s" _-, s_ w w w _w - 4.00 7.84 1092 _ .`-4.00 8.96 8.96 8.96 4 00 7.84 _8.96. 4.00 8.96 8.96 -_ 10.92 --38.02 9.02 10.34 - 2.19 24.45 24.75 25 20 219 9.02 _:9.41; 2.19 24.75 25.20 _ 10.34 2.2E .__ 0.00 0 0 -- -_ ----0 0 0 _ 0 ! -10 0 -_ T-0 65 0 0 - _-- 9 _ 70 -. - 70 0 0 - - - 0 0 0 0 0 0 0 0 0 0 _ D 0 261 0 0 Y -_ 0 _- _63 - _266 0 _._ _._ 0 0 0 0 0 0 _._ _ .__0 0 0 0 0 0 _.-__--0 0 0 0 0 0 -__ _._ 0 0 0 0 0 0 __ -_ __- 0 0 0 _ . 0 102 0 __ - Q 166 1114 0 __0 _ _ 408 - - -0 VVVVVV►►►���////// 6 MO 0 __-,_0 65 0 0 0 _70 -- - - 7 - - -0 .0 -_0 142 0 0 0 � , 157 _--_.-.--0 _ _ 47 0 - Q 121 45 0 0 w182 - -182 � 47 0 -___,0 76 3 0 _- 0 182 -- --18 ___-� 186 0 --Q 304 403 0 _-_ _Q � 163 --- 684 6 c) AED excursion -33 450 Envelope loss/gain 590 266 1741 2239 12 a) Infiltration b) Room ventilation 110 0 31 0 283 0 80 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 200 0 0 0 Subtotal (lines 6 to 13) 700 497 2024 2319 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 16 715 146 0 0 37 534 0 20% 0% 0 0 6 2029 414 0 0 14 2332 0 Total room load Air required (cfm) 861 30 534 23 2443 86 2332 102 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 41 ACZA500 Page wrightSOft' Right -Suite® Universal 2017 17.0.08 RSU08101 2018-Jan-24 11:age 5 E:\Documnets\Wrightsoft HVAC\SLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W - - wrightsoft. Right-J® Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 2 3 4 5 Room name E)posed wall Room height Room dimensions Room area FOYER 7.0 ft 9.3 ft heat/cool 7.0 x 9.0 ft 63.0 ft2 LIVING ROOM 15.0 ft 9.3 ft heat/cool 15.0 x 15.0 ft 225.0 ft2 Ty Construction number U-value (Btuh/ft1L°F) Or HTM (Btuh/ft2) Area (ft2) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 4.00 7.84 10.92 -4.00 8.96 8.96 _-_8.96 4.00 7.84 _ 6;96 4.96 8.96 8.96 10.92 _-„_ 38.02 2.19 9.02 __ _10.34 2.19 24.45 24.75 __- 25,20 2.19 9.02 ,. _ 9.4$ 24.75 4.75 25.20 10.34 __ OAO 0 0 0 - -- 0 0 0 0 0 0 _ _._ 0 65 0 16 24 _---, 63 D 0 : 0 -- - 0 0 0 -_ _ -nQ 0 0 �- __-_._w0 25 0 1 24 0 0 -- - 0 0 0 0 0 0 0 _-, _ _0 101 0 143 _ 262 0- 0 - - -- 9 0 0 0 . Q 0 0 __- --- 55 0 403 248.__..-,___0 0 0 --- 140 0 45 -----90 0 0 - --.__0 0 0 0 -----= 225 0 : 0 -- 4 55 0 3 -- - -2 0 .0 f 0 0 --- 218 0 403 � 0 0 - __- 0 0 0 0 �._ 0 0 0 --- - 0 119 0 1114 --- 1008 0 0 ----0- 0 0 0 _ _..__0 13A�ocs 2 glazing, clrlow-e 11D0 _ _ _ 13A4ocsM- - 2 glazing, clr low-e 2 glazing, clr low-e _2 glazinp,_clr low-e__._ 13A-0ocs 2 glazing, clr low-e cir low-e„_ 13AAocs 2 glazing, clr low-e 2 glazing, clr low-e 11D0 16A30md__ 2? tph------- - 0,143 0.280 0.390 _ -0.143 0.320 0.320 0.320 0.143 0.280 _-,_0.320 0.320 0.320 0.320 . 0.390 --1.358 n 'n n a a a e_ s s ._ w w w w ...�--- -111�VV///�����//// - __-- _ :.2.glazing, _ Vy .--_.--.0 0 0 0 _ 0 I{��_-_-_GGp -_ __._ -C. F,--- _------7 _-__-- 266 �--- -0 .- 15 __- 5700 6 c)AED excursion 73 12 Envelope loss/gain 829 920 1752 2757 12 a) Infiltration b) Room ventilation 110 0 31 0 236 0 66 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 1100 0 0 0 Subtotal (lines 6 to 13) 939 2051 1987 2824 14 15 Less extemal load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 207 1145 234 0 0 75 2127 0 20% 0% 0 0 11 1998 407 0 0 25 2849 0 Total room load Air required (cfm) 1379 49 2127 93 2405 851 2849 125 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. AC�A WritOft ghs' 2018Jan-24 11: Right -Suite® Universal 2017 17.0.08 RSU08101 Page age 6 E:\Documnets\Wrightsoft HVAC\SLAY RESIDENCE.rup Calc = MJB Front Door faces: W wrightsoft. Right-J® Worksheet Job: Entire House Date: Jan 24, 201E By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCS AOL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area CLST 3 9.0 ft 9.3 ft heat/cool 2.0 x 7.0 ft 14.0 ftz BEDROOM 3 26.0 ft 9.3 ft heat/cool 1.0 x 168:0 ft 168.0 ft2 Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft2) Area (ft-) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A4ocs 2 glazing, clr low-e 13A-40cs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazing dr low-e� _ 13A flocs 2 glazing, clr lower :2 glazing. clr_low_e_ 13A-0ocs 2 glazing, clr lower 2 glazing, cir low-e 11D0 0143 0.280 0.143 0.320 0.320 -_ _ 0.320 0 143 0.280 ,.1-0 320 0. 0.320320 0.320 --- 0.390 n n _m a a a a s ' s _ s_ w w w w - -4.00 7.84 10.92 4.00 8.96 8.96 8.96 4.00 7.84 _ _8.96. 4. 8.9696 8.96 10.92 2.19 9.02 __ 10.34___ 2.19 24.45 24.75 25.20 0. 2.10 9:02 _ 9.4.1 2.7 24.75 25.20 _ 10.34 __2.24 9.00 . - -' 65 0 ___0.._ 19 0 0 -Y 0 0 0 0 _ --. 85 0 _.___0_-----___0..___-_ 19 0 0 0 Y 0 0 _ -__-0 0 0 0 - - 0 ._ __ 14 .-__-_ 6 261 0 74 0 0 0 _ _ 0 0 ---__ -0 0 0 0 ._�._.-0 -- __ 13 _._ - ----•- 142 0 0 41 0 0 _ _0 0 0 _ _ _.-__0 0 0 0 . -- - 0 - �. 31_ 9 0 ___ 0 102 0 15 0_ 130 0 9 0 0 87 0 1 0 37 0 0 - 350 0 134 __ _ 0 521 0 ---= 0 0 0 0 20 0 ____ 0 191 0 371 0, V// I(I-GAG _ -G -__ 130 0 -- -__'_0 0 0 0 - 0 - -16.8 285 _ 0 0 0 0 -- -- 0 376 _I-=G_ y! _ _ 0 0 0 -- .._. Q - _-_ 14 14 ____O 0 0 0 0 a 168 -_ F•_-- - --- 16A-30md0.90 -22Atph____-._ _�_ -0 1b1 :L:� _� 38.02 _ �•_ __-__ 6 c)AED excursion -16 -92 Envelope loss/gain 690 199 2182 1151 12 a) Infiltration b) Room ventilation 141 0 40 0 408 0 115 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 0 0 600 Subtotal (lines 6 to 13) 831 238 2590 1867 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 -831 0 0 0 0 -238 0 0 20% 0% 0 0 835 3425 698 0 0 247 2113 0 Total room load Air required (cfm) 0 0 0 01 1 1146 4123 2113 92 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. �� wfTiginit50ft' RightSuite® Universal 2017 17.0.08 RSU08101 2018-Jan-24 1Page 7 EADocumnetslWrightsoft HVAC\SLAY RES]DENCE.rup Calc = MJ8 Front Door faces: W 9 -�- wrightsoft: Right-J® Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772.466-6796 Email: QUICKCALCS ,AOL.COM 1 2 3 4 5 Room name Fposed wall Room height Room dimensions Room area BATH 3 5.0 ft 9.3 ft heat/cool 10.0 x 5.0 ft 50.0 ftz BATH 2 5.0 ft 9.3 ft heat/cool 10.0 x 5.0 ft 50.0 ft' Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft�) Area (ft2) or perimeter (ft) Load (Btuh) Area (W) or perimeter (ft) Load (Btuh) Heat Cool Gross . N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 V+/ -- IL-GD _ - - - ------- 13A-0ocs -" 2 glazing, clr low-e 11DO 13A-4ocs J 2 glazing, cir low-e 2 glazing, cir low-e 2_ol - _q,_clr low_ e_--- 13A-4ocs 2 glazing, clr low-e ?.glazing, clr low_-e_-_ 13A4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11D0 - _.- --_ __. 16A 30md _ _ _ 0.280 0:280 _ 0.390 0.143 0.320 0.320 --_0.320 0.143 0.280 -__ 0.320 0.143 0.320 0.320 .. 0.390 0.032 --_ n � n n _...._ 4.84 7.84 -__ 2.02 9.02 10.34 __..---_ ^ 0 0 _ 0 - 0- 0 0 _-.-_•-_0 47 , 6 _- _. _ - -0 0 0 0 _0 --- _,-56 - ---- 50 _ "----- 0 0 _ _ . 0 0 0 0 ..>_ ___...0 41 6 ----0 0 0 0 _ 0 . 50 - -5 ---- - 0 "A -- ---•0 0 0 0 9 -- ---- 0 0 - --0 0 0 0 0 89 54 _ _A 0 0 0 -_ 0 _112 - ----0 -r- - 0 0 --------0 0 0 0 __.._ 47 6 _0 0 0 0 _ 0 - _56 50. ---- - - - 0 0 .----0 0 0 0 _.. _-0 41 6 __0 0 0 0 - - - -- 0 0 .--- ---0. 0 0 0 --_-_-. 4 162 47 _.___, 0- 0 0 0 - -- 0 0 _ _.---_-0- 0 0 0 .---_---_4 89 54 ___-_-0 0 0 0 _ ` 0 (--G _ e- a a -e s s __s_ w w w _ w _ - _ _ _ _ _10.92 - 4.00 8.96 8.96 _-- 8,96 4.00 7.84 -8.9.6. 4.00 8.96 8.96 10_92 0.90 . ^ 38_02 - -- 2.19 24.45 24.75 -_-_25.20 2.19 9.02 --_ 9..41. 2.19 24.75 25.20 _ 10.34 '_-" 2_24 0.00 - ._- 162 47 ________ 0 0 0 0 _ 0 _0 __45 ---190 _ . C-- _0 - -- 5 _. _ -_0 1.358 6 c)AED excursion -33 33 Envelope loss/gain 444 222 444 222 12 a) Infiltration b) Room ventilation 79 0 22 0 79 0 22 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 250 0 0 250 Subtotal (lines 6 to 13) 523 494 523 494 14 15 Less e)demal load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 6 529 108 0 0 14 508 0 20% 0% 0 0 6 529 108 0 0 14 508 0 Total room load Air required (cfm) 636 23 111 22 636 23 508 22 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. 'Fk wrightsOft' 2018-Jan-24 11:00:41 RightSuite® Universal 2017 17.0.08 RSU08101 �� E:\Documnets\Wrightsoft HVAC\SLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W Page 8 wrightsoft: Right-J® Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 STLUCIEi-ANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fax 772466-6796 Email: QUICKCALCSa,\OL.COM 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area BEDROOM 2 24.0 ft 9.3 ft heat/cool 1.0 x 139.0 ft 139.0 ft' CLST 2 7.0 ft 9.3 ft heat/cool 2.0 x 9.0 ft 18.0 ft' Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft') Area (ft') or perimeter (ft) Load (Btuh) Area (ft') or perimeter (ft) Load (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A46cs y.- .2 glazing, clr lower .- 11D0 13A- ocs 2 glazing, clr low-e 2 glazing, clr low-e 2 glazmq,_clr low-e.-_ 13A�ocs - 2 glazing, clr low-e :2 glazing,_giraow e. 13A-4ocs 2 glazing, clr low-e 2 glazing, clr low-e 11 D0 0.143 0.280 0.390 0.143 0.320 0.320 - _ 0.320 0143 0.280 - _0 320 0.143 0.320 0.320 0 390 -' 0 032 n n n a a a e- s - s -s._ w w w _ w_ _-~ 4.00 7.84 10.92 4.00 8.96 8.96 8.96 4.00 784 _8,96 4.00 8.96 8.96 10.92 �_-0.90 ' -2.19 9.02 10.34 2.19 24.45 24.75 25.20 2.19 9.02 _9.41 2.19 24.75 25.20 10_34 _ 2.24 - ___ .0 0 0 0 0 0 __._ _ , _0 484 0 _ __-_ -0 350 134 0 _ _0 - -_ 125 .__ ,-___0 0 0 0 0 0 _ _0 265 0 191 371 0 0 311 ----- 47 0 0 0 0 0 ..___ . - _0 0 0 ---0 19 0 0 0 : - ' 18 �' 47 0 0 0 0 0 _ - 0 0 0 - ---0 19 0 0 _ 0 u^ _ 18 - - 186 0 0 0 0 0 __ _ _._ 0 0 0 74 0 0 �_Y 0 -_ 16 002 0 0 0 0 0 _ -__ _0 0 0 41 0 0 0. ' -'-0 0 ,.. 0 0 0 0 __ _._ -_ 0 121 0 _ - -- _- 0 102 15 0 v - 0 _.- _139 '--,- 0 0 0 0 0 0 _ 0 121 0 --0 87 1 0 0 � 139 �D T--G -- _ y! iI--CGI _ _� _ _ 6 c)AED excursion 70 -13 Envelope loss/gain 2005 1208 543 169 12 a) Infiltration b) Room ventilation 377 0 106 0 110 0 31 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 650 0 0 0 Subtotal (lines 6 to 13) 2382 1965 653 200 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 1 20% 0% 0 0 458 2840 579 0 0 152 2117 0 20% 0%1 0 0 -653 0 0 0 0 -200 0 0 Total room load Air required (cfm) 3419 121 2117 93 0 0 0 0 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. -Fk wrightsoft' 2018-Jan-24 11:00:41 C Page 9 51 Right -Suite® Universal 2017 17.0.08 RSU08101 E:\Documnets\WrightsoftWAC\SLAYRESIDENCE.rup Calc = MJ8 Front Door faces: W - wrightsoft° Right-J® Worksheet Job: Entire House Date: Jan 24, 2018 By: QUICK CALCS, INC. 317 ST LUCIE1-ANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS a(JAOL.COM 1 2 3 4 5 Room name E)gwed wall Room height Room dimensions Room area HALL 0 ft 9.3 ft heaticool 3.0 x 14.0 ft 42.0 ftz Ty Construction number U-value (Btuh/ft;°F) Or HTM (Btuh/ft�) Area (ft-) or perimeter (ft) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 11 13A-- 2 glazing, clr low-e 11D0 ,_ 13AAocs 2 glazing, clr lower 2 glazing, clr low-e 2 glazinq,_clr low-e---- 13A-4ocs 2 glazing, clr low- 2 glazing, clr.low e__ 13A flocs 2 glazing, clr low-e 2 glazing, clr low-e 11DO 16AOmd. _ _ „ f 22Mtph 0:280 _ _ 0.390 0.3200.320 0.320 --.---.-0.320 --Y 0143 0.280 __ -0.320 0. 0.320320 0.320 __ 0.390 y 0.032_ �_ 0 0 0 0 0 0 _ -0 .----- 0 _Y_0 0 0 0 _ _0 42 0 0 0 0 0 0 _ -._0 0 __. °_- 0 0 0 0 0 -0--- 0 0 0 0 0 0 ____0 0 0 0 0 0 0 0 0 0 0 0 -______0 0 0 0 0� 'n, n 7.84 10.92 9:02 10.34 l-D V)/ a a a _e_ ' s s ,s_ w w w w � 4..19 8.9696 8.96 8.96 4.00 7.84 _ 8.96 4.9 8.96 6 8.96 10.92 _090 __ 38.02 24.45 24.75 _ 25.20 _ - 2.19 ' 9.02 __ . 9.41 2. 24.7575 25.20 10.34 ._ -2 24 I;(-�-CG - G G_ �- - F _ �_0 _.T 42-- 6 c)AED excursion -6 Envelope loss/gain 38 88 12 a) Infiltration b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 Appliances/other 0 0 0 Subtotal (lines 6 to 13) 38 88 14 15 Less external load Less transfer Redistribution Subtotal Duct loads 20% 0% 0 0 -38 0 0 0 0 -88 0 0 Total room load Air required (cfm) 0 0 0 0 -7 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -Fk- wright50ft' 2018-Jan-24 11:00:41 RightSuite® Universal 2017 17.0.08 RSU08101 .A E:\Documnets\Wrightsoft HVAC\SLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W Page 10 4 r1A 0 -- wrightsoft" Duct System Summary Entire House QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM For. SLAY RESIDENCE, TREFELNER CONSTRUCTION 120 BERGER ROAD, FORT PIERCE, FL 34945 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm Job: Date: Jan 24, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm 204 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 636 23 22 1.000 5.0 Ox 0 VIFx 40.4 135.0 st3 BATH 3 h 636 23 22 1.000 5.0 Ox 0 VIFx 48.2 155.0 st4 BEDROOM 2 h 3419 121 93 1.000 7.0 Ox0 VIFx 39.1 135.0 st3 BEDROOM 3 h 4123 146 92 1.000 7.0 Ox0 VIFx 48.7 155.0 st4 DINING ROOM c 2332 86 102 1.000 7.0 Ox0 VIFx 14.2 115.0 st2 FOYER c 2127 49 93 1.000 7.0 Ox0 VIFx 40.7 135.0 st3 KITCHEN c 2355 59 103 1.000 7.0 Ox 0 VIFx 15.2 115.0 SO LAUNDRY h 2518 89 60 1.000 6.0 Ox0 VIFx 12.6 115.0 st2 LIVING ROOM c 2849 85 125 1.000 7.0 Ox 0 VIFx 47.2 155.0 st4 M BATH h 1452 51 23 1.000 5.0 Ox0 VIFx 13.1 115.0 st1 Mwlc c 134 2 6 1.000 4.0 Ox0 VIFx 9.2 115.0 SO MASTER BEDROOM h 2596 92 91 1.000 7.0 Ox0 VIFx 16.4 115.0 st1 MASTER BEDROOM -A h 2596 92 91 1.000 7.0 Ox0 VIFx 12.1 115.0 st1 PANTRY h 861 30 23 1.000 5.0 Ox0 VIFx 8.5 115.0 st2 POWDER ROOM c 771 32 34 1.000 5.0 Ox0 VIFx 9.8 115.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Peak AVF 296 314 1.000 710 9.0 0 x 0 VinlFlx st4 Peak AVF 253 239 1.000 574 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 446 447 1.000 678 11.0 0 x 0 VinlFlx st2 st2 Peak AVF 684 666 1.000 870 12.0 0 x 0 VinlFlx -A:. * wrightsoft® Right -Suite® Universal 2017 17.0.08 RSU08101 ' 'EADocumnetslWrightsoft HVAC\SLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W 2018-Jan-24 11:00:42 Page 1 Name Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rbl Ox 0 980 980 0 0 0 0 Ox 0 VIFx wri htsoft° 2018-Jan-2411:00:42 9 Right -Suite® Universal 2017 17.0.08 RSU08101 Page 2 ZtA E:1Documnets\Wrightsoft WAMSLAY RESIDENCE.rup Calc = MJ8 Front Door faces: W