Loading...
HomeMy WebLinkAboutSEWAGE CONSTRUCTION INSPECTION & APPROVALOCANUV ED T118 BY �t Lucie Count APPLICATION #:AP1325754r � t.. • STATE' OF FLORIDA PERMIT 'fr..56-SF-1818738 F�. DEPARTMENT OF HEALTH DOCUMENT #:F11208207 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM DATE PAID:02128�2018 CONSTRUCTION INSPECTION AND FINAL APPROVAL WE FEE PAID:" 25.00 RECEIPT #:56-PI.D-3489288 APPLICANT: Katrina & Lawrence Slay AGENT; James Trefelner PROPERTY ADDRESS:120 Berger Rd Fort Pierce, FL 34945 LOT: 3 and-4 BLOCK: 2 SUBDIVISION; ID#I 2305-5014015400-0 CHECKED [X] ITEMS ARE NOT IN'COMPLIANCE,WITH ,STATUTE OR A= AND'MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01.] TANK SIZE [1] 1090.00 ['23 ( ] ['271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polyethylene ! I (28] DITCHES 56 FT [ ) [031 OUTLET DEVICE [ ], [291 PRIVATE WELLS 100 FT [ ] [04] MULTI -CHAMBERED [ L-Ij N J [ J [301 PUBLIC,WELLS FT [ ] [05] OUTLET FILTER Polylok•PL-68 [ ] [31] IRRIGATION WELLS FT [ ] [0.6] LEGEND 1. 70-143=11DC3 2. [ ] [.32] POTABLE WATER 57 FT' [ ] (071 WATERTIGHT [ ] [33] BUILDING FOUNDATIONS 5 FT' [ ] [08.] LEVEL [ ] [341 PROPERTY LINES 27 FT [ J [0.91 DEPTH TO 'LID [ ] [35.] OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1_] 509.4 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ J [371, SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 5.00 2. [ J [38]' SLOPES. [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 09/17/2018 [ ] [14] DRAINLINE SLOPE [ ] [15.1 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [16] ELEVATION [ ABOVE / BELOW ]BM •4.00 [ .] [40] UNOBSTRUCTED AREA [ ] [•17] SYSTEM LOCATION [ ] [411, .STORMWATER RUNOFF [ ] '[T8] DOSING PUMPS [ ] [42]. ALARMS' [ ] [19] AGGREGATE SI•'LE [ ] [43,1 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE.EXCESSIVE FINES [ '] [44] BUILDING, AREA [ ] [21] AGGREGATE DEPTH [ ] [451 LOCATION,CONFORMS'WITH" SITE PLAN I ;] [46] FINAL SITE GRADING FILL /EXCAVATION MATERIAL [ '] [47-] CONTRACTOR MICHAEL..W STUHR (ASHTO [ ] [221 FILL. AMOUNT. [ ] [48] OTHER INFILTRATOR QuickPlus E036 LP [ ] [231 FILL TEXTURE [ 1 [24] EXCAVATION DEPTH ABANDONMENT [ ] [25.1 AREA REPLACED [ ] [49] TANK PUMPED [ ) [261 REPLACEMENT,MATERIAL ( J [501 TANK CRUSHED 6 FILLED Comments: Comments are, on page 2. St. Lucie CHD DATE: 07/06/2018 CONSTRUCTION [ APPROVED DISAPPROVED J ° Environmental Speolall II Brian J Ingram (ENVIRONMENTAL HEALTH) FINAL SYSTEM [ APPROVED / DISAPPROVED ]:-'^'�'`'Y St. LUCIe CHI) DATE: 09/17/2018 Environmental Supervisor I Dianna S May (Florida, Department'of Heal (Explanation of Violations on following page) DH 401:6,. 08./09 (Obsoletes all previous ed'i.tions�which may riot be used) Page 2 of 3 Incorporated: 64E-6.003, FAC EH Database v. 1.0.1 AP1325754 EID1310730 jb ' f I STATE OF FLORIDA DEPARTMENT OF HEALTH; '�qQ ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM ,y CONSTRUCTION 'INSPECTION AND FINAL APPROVAL Violation Number Comment its APPLICATION' #: AN 3257.54 'PERMIT, # 56-SF•-1818738 DocumENT #: FI1•20820'7 DATE PAID:02I28/201.8 FEE, PAID:25•.00 RECEIPT #:5&PID-348928.$ The system is sized for 3 bedroo"ms with a' maximum occupancy. of 6 persons (2 per bedroom), for a°total estimated flow. of 300 gpd. New ST, outlet filter, and 5x9 DF`lnstalled. No violations, system ok to cover, Contactor notified by phone. Needs•final' inspection formound system and final site grading. Well inspected at constructioninspection. Final inspection for final site grading and mound T,systern satisfactory. No>violations observed. Emailed to contractor and building department. DH 4016;'08/0.9 (Obsolete.s all previ;ous.edit:ons whsgh may not, be used) Incorporated: 64E-6..003, FAC' Page.2 of 3 E14 Oatabise v 1.0.1 AP-1325754 ElD1$ IU73S'