Loading...
HomeMy WebLinkAboutELEVATION CERTIFICATE 9-19-18SCANNED _ i `U:S. ;DEPARTMENT OF HOMELANf 11RITY BY i' OMB No. 1660-0Od8 Federal ,'emergency Management Agt. 16,-- ' St Lucie (e®UC1�/ Expiration Date: November 30, 2018 National Flood Insurance Program ELEVATION CERTIFICATE Important: Follow the instructions on pages 1-9. Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner. ' SECTION A — PROPERTY INFORMATION FOR INSURANCE COMPANY USE Al. Building Owner's Name Policy Number. MICHIELSEN A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Company NAIC Number: Box No. 1044 NETTLES BLVD. City State ZIP Code JENSEN BEACH FLORIDA 34957 A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.) LOT 1044, NETTLES ISLAND PROJECT SECTION 2 A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL A5. Latitude/Longitude: Lat. 27°17'04.1" Long. 80*13'28 4" Horizontal Datum- ❑ NAD 1927 ® NAD 1983 A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance. A7. Building Diagram Number 1 B A8. For a building with a crawlspace or enclosure(s): a) Square footage of crawlspace or enclosure(s) N/A sq ft b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade N/A c) Total net area of flood openings in A8.b N/A sq in d) Engineered flood openings? ❑ Yes ® No A9. For a building with an attached garage: a) Square footage of attached garage 180 sq ft b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 2 c) Total net area of flood openings in A9.b 3440 sq in d) Engineered flood openings? ® Yes ❑ No SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION B1. NFIP Community Name & Community Number B2. County Name B3. State UNINCORP'120285 ST. LUCIE FLORIDA B4. Map/Panel B5. Suffix B6. FIRM Index B7. FIRM Panel B8. Flood B9. Base Flood Elevation(s) Number Date Effective/ Zone(s) (Zone AO, use Base Flood Depth) Z Revised Date DZ' IZ A B10. Indicate the source of the Base Flood Elevation (BFE).data or base flood depth entered in Item 139: ❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source: B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ® NAVD 1988 - ❑ Other/Source: B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No Designation Date: NIA ❑ CBRS ❑ OPA FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6 • -ELEV TIONf CERTIFICATE OMB No. 1660-0008 Expiration Date: November 30 2016— IMPORTANT: In these spaces, copy the corresponding information from Section A. FOR INSURANCE COMPANY USE Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No. Policy Number. 1044 NETTLES BLVD. City State ZIP Code Company NAIC Number JENSEN BEACH FLORIDA 34957 SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED) C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction *A new Elevation Certificate will be required when construction of the building is complete. C2. Elevations — Zones Al A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, AR/A, AR/AE, AR/A1 A30, AR/AH, AR/AO. Complete Items C2.a—h below according to the building diagram specked in Item A7. In Puerto Rico only, enter meters Benchmark Utilized: 94 77 A04 FLDT Vertical Datum: NAVD 1988 Indicate elevation datum used for the elevations in items a) through h) below. ❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source: Datum used for building elevations must be the same as that used for the BFE. Check the measurement used. a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 7.0 ® feet ❑ meters b) Top of the next higher floor N/A ❑ feet ❑ meters c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters d) Attached garage (top of slab) 4•8 ® feet ❑ meters e) Lowest elevation of machinery or equipment servicing the building 7.0 ® feet ❑ meters (Describe type of equipment and location in Comments) 4.4 f) Lowest adjacent (finished) grade next to building (LAG) ® feet ❑ meters g) Highest adjacent (finished) grade next to building (HAG) 4.7 ® feet ❑ meters h) Lowest adjacent grade at lowest elevation of deck or stairs, including 4 7 ® feet ❑ meters structural support SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information. I certify that the information on this Certificate represents my best efforts to interpret the data available. l understand that any false statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001. Were latitude and longitude in Section A provided by alicensed land surveyor? ®Yes ❑ No ® Check here if attachments. Certfier's Name License Number 1320-94-01-FINAL EARLE R. STARKEY 004459 Title PROFESSIONAL LAND SURVEYOR Company Name ACCURIGHT LAND SURVEYING INC. Address 1501 DECKER AVENUE #419 09/19/2018 City State ZIP Code STUART FLORIDA 34994 RLS #4459 nature Date Telephone_ Ext. 09/19/2018 772-286-7694 attachments Copy all pages of ertificate and all for 111community official, (2) insurance agenticompany, and (3) building owner. Comments (including type of equipment and location, per C2(e), if applicable) A-9 (A D) THE GARAGE IS A 3 SIDED CARPORT WITH 1 FLOOD FLAP MODEL #FFWF05 220 SQ. FT. THE REST OF THE OPENING AREA WAS CALCULATED BY USING THE LENGTH TIMES 12" UP OFTHE CARPORT OPENING. C2-E IS THE BOTTOM OF THE ELECTRIC METER BOX. FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6 Building Photographs See Instructions for Item A6_ For Insurance Company Use: Building Street Address (inducting Apt., tlnik Suite, anWor W. No.) or P.O. Route and Box No. Porky Number 1044 NETTLES BLVD. City State ZIP Code Ea�r�perh►twtcntu JENSEN BEACH FLORIDA 34957 If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to the instructions for Item A6. Identify all photographs with: date taken; "Front View' and "Rear Vieve; and, if required, "Right Side View".and .and "Left Side View:" If submitting more photographs than will fit on this page, use the Continuation Page, following. FRONT 09/19/2018 REAR 09/19/2018 r � f ¢ WidXX�,p WN Tom-+-� ,1 w 5f „al.;.. "Sl.�-s.• jx v 1 �p pu ' C _ >•,` "�' f +IN. .t v`3 r ) t d y�d le „p q{ ,Ji�7y1 fin 4 Y J! 4 ^c bxT a� t le 1wl 3 k 5 - t f i , C j J'p 4 1 i k N bier :rp , k ! t E (gil�: �.I• SIDE 09/17/2018 DIVISION: 08 00 00--OPENINGS SECTION: 08 95 43—VENTSJFOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS®, LLC POST OFFICE BOX 1003 ISLE OF PALMS, SOUTH CAROLINA 29451 EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; F-FNF05 ICC ICC ICC ( )�R)S *491 a(4EC PMG6LISTED Look for the trusted marks of Con€ormityl "2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" \1. ■sue man A Subsidiary of WEtwor ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not cs" specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a t recommendation for its use. There is no warranty by ICC Evaluation Service LLC, express or implied, as r"Ec goes to anv f nding or other matter in this report, or as to any product covered by the report. Ate+"' l eu, Coovright 0 2017 ]CC Evaluation Service, LLC. All rights reserved. ICC-ES Evaluation Report ESR-3560 Reissued September 2017 This report is subject to renewal September 2018 wwwJcc-es.orct J (800) 423-6687 1 (562) 699-0543 A Subsidiary of the lntemaiional Code Council® DIVISION: 08 00 00—OPENINGS Section: 08 95 43—Vents/Foundation Flood Vents REPORT HOLDER: FLOOD FLAPSe, LLC POST OFFICE BOX 1003 ISLE OF PALMS, SOUTH CAROLINA 29451 (843)881.0190 www.fioodflans.com infoDfloodllaas.com EVALUATION SUBJECT: FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05 1.0 EVALUATION SCOPE Compliance with the following codes: ■ 2015, 2012 and 2009 Intenlatlonal Building Code® (IBC) ■ 2015, 2012 and 2009 Intemaganal Residential Codee (1RC) Properties evaluated: ■ Physical operation ■ Water flow ■ Weathering 2.0 USES Flood Flaps® automatic flood vents are used to provide for the equalization of hydrostatic flood forces on exterior wails Certain models also allow natural ventilation. 3.0 DESCRIPTION 3.1 General: Flood Flaps® automatic flood vents are engineered mechanically operated flood vents (FVs) that automatically allow flood waters to enter and exit enclosed areas. The FVs are constructed of ABS plastic which serves as the FVs housing, and a front grill that contains an anodized metal screen Imbedded In polypropylene plastic. On contact with rising flood water, the grill will disengage from its secured position, allowing flood water and debris to flow through in either direction. The FVs are available in two series as described in Section 3.3. The sealed series models contain two rubber flaps that close the FV to the passage of air when using with conditioned areas or sealed crawl spaces. In the same manner as the grill, the two rubber flaps are pushed open by water pressure, allowing water and debris to flow through the FV in either direction. See Figure 1 for an illustration of the Flood Flaps® automatic FV. 3.2 Engineered Opening: The Flood Flaps® automatic FVs comply with the design principle noted in Sections 2.7Z.2 and 2.7.3 of ASCEISEI 24-14 (Section 2.6.2.2 of ASCE/SE124-05 (2012 and 2009 IBC and IRC)] for a rate of rise and fall of 5 feet per hour (0.423 mm/s). In order to comply with the engineered opening requirement of ASCEISEI 24, Flood Flaps® automatic FVs must be installed in accordance with Section 4.0. 3.3 Flood Vent Series Models: Flood Flap? automatic FVs are available in two series with multiple models and sizes as described in Table 1. The sealed series models, designated FFWF, include two rubber flaps for the prevention of air flow. The multi- purpose series, designated FFNF, omits the rubber flaps. 3A Natural Ventilation: Flood Flaps® automatic FV models FFNF12, FFNF08, FFNF05, and FFNF02 have metal screens with 1/4 inch by 1/4 inch (6 mm by 6 mm) openings and provide 37 square inches (0.02 m) of net free opening to supply natural ventilation for under -floor ventilation. Flood Flaps® automatic FV models FFWF12, FFWF08, and FFWF05 have not been evaluated for use as openings for under- floor ventilation. 4.0 DESIGN AND INSTALLATION Flood Flapse automatic FVs are designed to be Installed into walls of existing or new construction. Installation of the FVs must be In accordance with the manufacturer's instructions, the applicable code and this report. Flood Flaps® automatic FVs can be installed in wood, masonry and concrete walls up to a thickness of 12 inches (305 mm). In order to comply with the engineered opening design principle noted in Sections 2.7.2.2 and 2.7.3 of ASCE/SEI 24-14 [Section 2.62.2 of ASCE/SEI 24-05 (2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must be installed as follows: ■ With a minimum of two openings on different sides of each enclosed area. ICC-a &4juation Reporls are not to be comirued 04 representing owhelks or any other attributes not spectficwAyoddmted, nor are they to be construed as on endorsement olthe subject ofthe report or a recommendationfor its use There is na warranty by !CC Evaluation Service, LLC, express or tmptled as a \� to anyjurdtngorother rrmuer to this report or as to mry product covered by the report. a rnnvenhi m 2017 ICC Evaluation service. LLC. All rights reserved. Page 1 of 3 N.With,a minimum - of one R _ - every 220 square feet.(20 m2) of enclosed area. ■ Below the base flood elevation. IN With the bottom of the FV located a maximum of 12 inches (305 mm) above grade. 5.0 CONDITIONS OF USE The Flood Flaps® automatic flood vents described in this report comply with, or are suitable alternatives to what is specifled in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The Flood Flapse automatic FVs must be installed in accordance with this report, the applicable code and the manufacturer's installation instructions. In the event of a conflict, the instructions in this report govern. 5.2 The Flood F, ° automatic FVs must not be used in place of " brG6eway ' walls" in coastal high hazard areas, but are permitted for use in conjunction with breakaway watts in other areas. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Mechanically Operated Flood Vents (AC364), dated August 2015. 7.0 IDENTIFICATION The Flood Flaps® models recognized in this report are identified by a label bearing the manufacturer's name, the model number, and the evaluation report number (ESR 3560). TABLE 1--FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES MODEL NUMBER MODEL DESIGNATION ROUGH OPENING (Width X Height) (inches) VENT SIZE (W X H X D) (inches) ENCLOSED AREA COVERAGE (fe) NET FREE AREA OPENING' Cn� FFWF12 Sealed Series 16 x e 1 fl. X 711, X 12 22D NA FFNF12 Multi -Purpose 16 x 8 15 /a X r14 X 12 220 37 FFWFD8 Sealed Series 16 x 8 1571. x & x 8 220 NA FFNFD8 Multi -Purpose 16 x 8 15 /a x /a x 6 220 37 ; FFWF05 Seated Series 16 x 8 15 /a x /4 x 5 220 NA b.ultiVtipiasi3 For 3I:1 inch = 25A mm;1 = MGM m 'For under floor ventilation only.