HomeMy WebLinkAboutELEVATION CERTIFICATE 9-19-18SCANNED _
i
`U:S. ;DEPARTMENT OF HOMELANf 11RITY BY i' OMB No. 1660-0Od8
Federal ,'emergency Management Agt. 16,-- ' St Lucie (e®UC1�/ Expiration Date: November 30, 2018
National Flood Insurance Program
ELEVATION CERTIFICATE
Important: Follow the instructions on pages 1-9.
Copy all pages of this Elevation Certificate and all attachments for (1) community official, (2) insurance agent/company, and (3) building owner.
' SECTION A — PROPERTY INFORMATION
FOR INSURANCE COMPANY USE
Al. Building Owner's Name
Policy Number.
MICHIELSEN
A2. Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and
Company NAIC Number:
Box No.
1044 NETTLES BLVD.
City State ZIP Code
JENSEN BEACH FLORIDA 34957
A3. Property Description (Lot and Block Numbers, Tax Parcel Number, Legal Description, etc.)
LOT 1044, NETTLES ISLAND PROJECT SECTION 2
A4. Building Use (e.g., Residential, Non -Residential, Addition, Accessory, etc.) RESIDENTIAL
A5. Latitude/Longitude: Lat. 27°17'04.1" Long. 80*13'28 4" Horizontal Datum- ❑ NAD 1927 ® NAD 1983
A6. Attach at least 2 photographs of the building if the Certificate is being used to obtain flood insurance.
A7. Building Diagram Number 1 B
A8. For a building with a crawlspace or enclosure(s):
a) Square footage of crawlspace or enclosure(s) N/A sq ft
b) Number of permanent flood openings in the crawlspace or enclosure(s) within 1.0 foot above adjacent grade N/A
c) Total net area of flood openings in A8.b N/A sq in
d) Engineered flood openings? ❑ Yes ® No
A9. For a building with an attached garage:
a) Square footage of attached garage 180 sq ft
b) Number of permanent flood openings in the attached garage within 1.0 foot above adjacent grade 2
c) Total net area of flood openings in A9.b 3440 sq in
d) Engineered flood openings? ® Yes ❑ No
SECTION B — FLOOD INSURANCE RATE MAP (FIRM) INFORMATION
B1. NFIP Community Name & Community Number
B2. County Name
B3. State
UNINCORP'120285
ST. LUCIE
FLORIDA
B4. Map/Panel
B5. Suffix
B6. FIRM Index
B7. FIRM Panel
B8. Flood
B9. Base Flood Elevation(s)
Number
Date
Effective/
Zone(s)
(Zone AO, use Base Flood Depth)
Z
Revised Date
DZ' IZ
A
B10. Indicate the source of the Base Flood Elevation (BFE).data or base flood depth entered in Item 139:
❑ FIS Profile ® FIRM ❑ Community Determined ❑ Other/Source:
B11. Indicate elevation datum used for BFE in Item 139: ❑ NGVD 1929 ® NAVD 1988 - ❑ Other/Source:
B12. Is the building located in a Coastal Barrier Resources System (CBRS) area or Otherwise Protected Area (OPA)? ❑ Yes ® No
Designation Date: NIA ❑ CBRS ❑ OPA
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 1 of 6
• -ELEV TIONf CERTIFICATE
OMB No. 1660-0008
Expiration Date: November 30 2016—
IMPORTANT: In these spaces, copy the corresponding information from Section A.
FOR INSURANCE COMPANY USE
Building Street Address (including Apt., Unit, Suite, and/or Bldg. No.) or P.O. Route and Box No.
Policy Number.
1044 NETTLES BLVD.
City State ZIP Code
Company NAIC Number
JENSEN BEACH FLORIDA 34957
SECTION C — BUILDING ELEVATION INFORMATION (SURVEY REQUIRED)
C1. Building elevations are based on: ❑ Construction Drawings* ❑ Building Under Construction* ® Finished Construction
*A new Elevation Certificate will be required when construction of the building is complete.
C2. Elevations — Zones Al A30, AE, AH, A (with BFE), VE, V1 V30, V (with BFE), AR, AR/A, AR/AE, AR/A1 A30, AR/AH, AR/AO.
Complete Items C2.a—h below according to the building diagram specked in Item A7. In Puerto Rico only, enter meters
Benchmark Utilized: 94 77 A04 FLDT Vertical Datum: NAVD 1988
Indicate elevation datum used for the elevations in items a) through h) below.
❑ NGVD 1929 ® NAVD 1988 ❑ Other/Source:
Datum used for building elevations must be the same as that used for the BFE.
Check the measurement used.
a) Top of bottom floor (including basement, crawlspace, or enclosure floor) 7.0 ® feet ❑ meters
b) Top of the next higher floor N/A ❑ feet ❑ meters
c) Bottom of the lowest horizontal structural member (V Zones only) N/A ❑ feet ❑ meters
d) Attached garage (top of slab) 4•8 ® feet ❑ meters
e) Lowest elevation of machinery or equipment servicing the building 7.0 ® feet ❑ meters
(Describe type of equipment and location in Comments)
4.4
f) Lowest adjacent (finished) grade next to building (LAG) ® feet ❑ meters
g) Highest adjacent (finished) grade next to building (HAG) 4.7 ® feet ❑ meters
h) Lowest adjacent grade at lowest elevation of deck or stairs, including 4 7 ® feet ❑ meters
structural support
SECTION D — SURVEYOR, ENGINEER, OR ARCHITECT CERTIFICATION
This certification is to be signed and sealed by a land surveyor, engineer, or architect authorized by law to certify elevation information.
I certify that the information on this Certificate represents my best efforts to interpret the data available. l understand that any false
statement may be punishable by fine or imprisonment under 18 U.S. Code, Section 1001.
Were latitude and longitude in Section A provided by alicensed land surveyor? ®Yes ❑ No ® Check here if attachments.
Certfier's Name License Number
1320-94-01-FINAL
EARLE R. STARKEY 004459
Title
PROFESSIONAL LAND SURVEYOR
Company Name
ACCURIGHT LAND SURVEYING INC.
Address
1501 DECKER AVENUE #419
09/19/2018
City State ZIP Code
STUART
FLORIDA 34994
RLS #4459
nature Date Telephone_ Ext.
09/19/2018 772-286-7694
attachments
Copy all pages of ertificate and all for 111community official, (2) insurance agenticompany, and (3) building owner.
Comments (including type of equipment and location, per C2(e), if applicable)
A-9 (A D) THE GARAGE IS A 3 SIDED CARPORT WITH 1 FLOOD FLAP MODEL #FFWF05 220 SQ. FT. THE REST OF
THE OPENING AREA WAS CALCULATED BY USING THE LENGTH TIMES 12" UP OFTHE CARPORT OPENING.
C2-E IS THE BOTTOM OF THE ELECTRIC METER BOX.
FEMA Form 086-0-33 (7/15) Replaces all previous editions. Form Page 2 of 6
Building Photographs
See Instructions for Item A6_
For Insurance Company Use:
Building Street Address (inducting Apt., tlnik Suite, anWor W. No.) or P.O. Route and Box No. Porky Number
1044 NETTLES BLVD.
City State ZIP Code Ea�r�perh►twtcntu
JENSEN BEACH FLORIDA 34957
If using the Elevation Certificate to obtain NFIP flood insurance, affix at least two building photographs below according to
the instructions for Item A6. Identify all photographs with: date taken; "Front View' and "Rear Vieve; and, if required, "Right
Side View".and .and "Left Side View:" If submitting more photographs than will fit on this page, use the Continuation Page,
following. FRONT 09/19/2018 REAR 09/19/2018
r � f
¢ WidXX�,p
WN
Tom-+-� ,1 w 5f „al.;.. "Sl.�-s.•
jx
v
1 �p
pu
' C _
>•,` "�'
f
+IN. .t
v`3 r )
t d y�d le „p q{ ,Ji�7y1 fin 4 Y J!
4 ^c bxT a�
t le 1wl 3
k
5
- t
f i
, C j J'p 4 1 i
k
N
bier :rp , k ! t E (gil�: �.I•
SIDE 09/17/2018
DIVISION: 08 00 00--OPENINGS
SECTION: 08 95 43—VENTSJFOUNDATION FLOOD VENTS
REPORT HOLDER:
FLOOD FLAPS®, LLC
POST OFFICE BOX 1003
ISLE OF PALMS, SOUTH CAROLINA 29451
EVALUATION SUBJECT:
FLOOD FLAPS® AUTOMATIC FLOOD VENTS:
MODELS FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; F-FNF05
ICC ICC ICC
( )�R)S
*491 a(4EC
PMG6LISTED
Look for the trusted marks of Con€ormityl
"2014 Recipient of Prestigious Western States Seismic Policy Council
(WSSPC) Award in Excellence"
\1.
■sue
man
A Subsidiary of WEtwor
ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not cs"
specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a t
recommendation for its use. There is no warranty by ICC Evaluation Service LLC, express or implied, as
r"Ec goes
to anv f nding or other matter in this report, or as to any product covered by the report. Ate+"' l eu,
Coovright 0 2017 ]CC Evaluation Service, LLC. All rights reserved.
ICC-ES Evaluation Report ESR-3560
Reissued September 2017
This report is subject to renewal September 2018
wwwJcc-es.orct J (800) 423-6687 1 (562) 699-0543 A Subsidiary of the lntemaiional Code Council®
DIVISION: 08 00 00—OPENINGS
Section: 08 95 43—Vents/Foundation Flood Vents
REPORT HOLDER:
FLOOD FLAPSe, LLC
POST OFFICE BOX 1003
ISLE OF PALMS, SOUTH CAROLINA 29451
(843)881.0190
www.fioodflans.com
infoDfloodllaas.com
EVALUATION SUBJECT:
FLOOD FLAPS® AUTOMATIC FLOOD VENTS: MODELS
FFWF12; FFNF12; FFWF08; FFNF08; FFWF05; FFNF05
1.0 EVALUATION SCOPE
Compliance with the following codes:
■ 2015, 2012 and 2009 Intenlatlonal Building Code® (IBC)
■ 2015, 2012 and 2009 Intemaganal Residential Codee
(1RC)
Properties evaluated:
■ Physical operation
■ Water flow
■ Weathering
2.0 USES
Flood Flaps® automatic flood vents are used to provide for
the equalization of hydrostatic flood forces on exterior
wails Certain models also allow natural ventilation.
3.0 DESCRIPTION
3.1 General:
Flood Flaps® automatic flood vents are engineered
mechanically operated flood vents (FVs) that automatically
allow flood waters to enter and exit enclosed areas. The
FVs are constructed of ABS plastic which serves as the
FVs housing, and a front grill that contains an anodized
metal screen Imbedded In polypropylene plastic. On
contact with rising flood water, the grill will disengage from
its secured position, allowing flood water and debris to flow
through in either direction. The FVs are available in two
series as described in Section 3.3.
The sealed series models contain two rubber flaps that
close the FV to the passage of air when using with
conditioned areas or sealed crawl spaces. In the same
manner as the grill, the two rubber flaps are pushed open
by water pressure, allowing water and debris to flow
through the FV in either direction. See Figure 1 for an
illustration of the Flood Flaps® automatic FV.
3.2 Engineered Opening:
The Flood Flaps® automatic FVs comply with the design
principle noted in Sections 2.7Z.2 and 2.7.3 of ASCEISEI
24-14 (Section 2.6.2.2 of ASCE/SE124-05 (2012 and 2009
IBC and IRC)] for a rate of rise and fall of 5 feet per hour
(0.423 mm/s). In order to comply with the engineered
opening requirement of ASCEISEI 24, Flood Flaps®
automatic FVs must be installed in accordance with
Section 4.0.
3.3 Flood Vent Series Models:
Flood Flap? automatic FVs are available in two series
with multiple models and sizes as described in Table 1.
The sealed series models, designated FFWF, include two
rubber flaps for the prevention of air flow. The multi-
purpose series, designated FFNF, omits the rubber flaps.
3A Natural Ventilation:
Flood Flaps® automatic FV models FFNF12, FFNF08,
FFNF05, and FFNF02 have metal screens with 1/4 inch by
1/4 inch (6 mm by 6 mm) openings and provide 37 square
inches (0.02 m) of net free opening to supply natural
ventilation for under -floor ventilation. Flood Flaps®
automatic FV models FFWF12, FFWF08, and FFWF05
have not been evaluated for use as openings for under-
floor ventilation.
4.0 DESIGN AND INSTALLATION
Flood Flapse automatic FVs are designed to be Installed
into walls of existing or new construction. Installation of
the FVs must be In accordance with the manufacturer's
instructions, the applicable code and this report. Flood
Flaps® automatic FVs can be installed in wood, masonry
and concrete walls up to a thickness of 12 inches
(305 mm). In order to comply with the engineered opening
design principle noted in Sections 2.7.2.2 and 2.7.3 of
ASCE/SEI 24-14 [Section 2.62.2 of ASCE/SEI 24-05
(2012 and 2009 IBC and IRC)], the Flood Flaps® FVs must
be installed as follows:
■ With a minimum of two openings on different sides of
each enclosed area.
ICC-a &4juation Reporls are not to be comirued 04 representing owhelks or any other attributes not spectficwAyoddmted, nor are they to be construed
as on endorsement olthe subject ofthe report or a recommendationfor its use There is na warranty by !CC Evaluation Service, LLC, express or tmptled as a \�
to anyjurdtngorother rrmuer to this report or as to mry product covered by the report. a
rnnvenhi m 2017 ICC Evaluation service. LLC. All rights reserved. Page 1 of 3
N.With,a minimum - of one R _ - every 220 square
feet.(20 m2) of enclosed area.
■ Below the base flood elevation.
IN With the bottom of the FV located a maximum of
12 inches (305 mm) above grade.
5.0 CONDITIONS OF USE
The Flood Flaps® automatic flood vents described in this
report comply with, or are suitable alternatives to what is
specifled in, those codes listed in Section 1.0 of this report,
subject to the following conditions:
5.1 The Flood Flapse automatic FVs must be installed in
accordance with this report, the applicable code and
the manufacturer's installation instructions. In the
event of a conflict, the instructions in this report
govern.
5.2 The Flood F, ° automatic FVs must not be used in
place of " brG6eway ' walls" in coastal high hazard
areas, but are permitted for use in conjunction with
breakaway watts in other areas.
6.0 EVIDENCE SUBMITTED
Data in accordance with the ICC-ES Acceptance Criteria
for Mechanically Operated Flood Vents (AC364), dated
August 2015.
7.0 IDENTIFICATION
The Flood Flaps® models recognized in this report are
identified by a label bearing the manufacturer's name,
the model number, and the evaluation report number
(ESR 3560).
TABLE 1--FLOOD FLAP AUTOMATIC FLOOD VENT MODEL SIZES
MODEL
NUMBER
MODEL
DESIGNATION
ROUGH OPENING
(Width X Height)
(inches)
VENT SIZE
(W X H X D)
(inches)
ENCLOSED AREA
COVERAGE
(fe)
NET FREE AREA
OPENING'
Cn�
FFWF12
Sealed Series
16 x e
1 fl. X 711, X 12
22D
NA
FFNF12
Multi -Purpose
16 x 8
15 /a X r14 X 12
220
37
FFWFD8
Sealed Series
16 x 8
1571. x & x 8
220
NA
FFNFD8
Multi -Purpose
16 x 8
15 /a x /a x 6
220
37 ;
FFWF05
Seated Series
16 x 8
15 /a x /4 x 5
220
NA
b.ultiVtipiasi3
For 3I:1 inch = 25A mm;1 = MGM m
'For under floor ventilation only.