HomeMy WebLinkAboutPRODUCT APPROVAL PANEL WALLS SIDINGrF•
.l
BCIS Home Log In ; User Registration 4 Hot Topics Submit Surcharge Slats & Facts
E 'Crti�^U{f
'¢
Product Approval
6 ' USER: Public User
i
Product Approval Menu > Product or Application
Search > Application List > Application Detail
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
Product Manufacturer
Address/Phone/Email
r
Authorized Signature
I
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Publications FBC Staff BCIS Site Map : Links Search
ST. LUCI irnrr� , ry pT r PI►SIO�i
REVIEW Ei) FOR COS^ - E W
REVIEWED B
DATE 3/6
PLANS ANIS PERMIT MUST BE KEPT ON JOB
OR NO INSPECTION WILL BE MADE.
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT TO ANY CORRECTIONS
Style Crest Inc.
REQUIRED BY FIELD INSPECTORS THAT
600 Hagerty Drive
MAY BE NECENAAY
Fremont, OH 43420
Fremont,
IN ORDER TO
(419) 333-5835
CQMY WITH A" APMABLE
lewi s. pope@stylecrest. net
CODES.
Lewis Pope
lewis.pope@stylecrest.net
Lewis Pope
600 Hagerty Drive
Fremont, OH 43420
(419) 333-5835
lewis.pope@stylecrest.net
Lewis Pope
600 Hagerty Dr
Fremont, OH 43420
lewis.pope@poly-foam.com
=PanelWalls
CONCE► o FASZI ERS ORPTACHWE-N-1S
ARE THE RESPOHSIB UyOF THE
CONi VOR OFRECOM
Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Eric J. Tompos P.E.
Evaluation Report
Florida License PE-63511
Quality Assurance Entity Architectural Testing, Inc., an Intertek company
Quality Assurance Contract Expiration Date 12/31/2020
Validated By William R. Heiden III, P.E.
Validation Checklist - Hardcopy Received
Certificate of Independence FL12231 R4 COI EJT COI.pdf
Referenced Standard and Year (of Standard) Standard Year
ASITM D3679 2011 •
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
v..,,STC062..717 32 Equiva..lgnce Qf $tandards_2Q17,10_
Q6,pdf
Sections from the Code
FILF Copy
0
.t
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Ill Method 1 Option D
10/11/2017
11/21/2017
11/28/2017
02/13/2018
.FL 41: S , ,, ; r z ,; `a 1 i I,Moclel, Number or Namel
122311}! {! ?,` ' : ° ' Fairfield, Alpine Ridge and Rid
;Vinyl Siding
. .t -' i •i,, � 1,;''.,, i_lmits,-ofUse;: .+jl.,`!
•Approved for,.use in HVHZ: No
{ , f ?• i l ! ?' ' Approverd'for useioufside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-59
Other: Design pressure varies based on the installatior
6,w j" � method.t PI'ease.refer-to the evaluation report for the 1 c
: , ,,r:.•
d"eslgn pressure based on the installation.
.•+ ••, n t 11 J 0
.l r, f`,r•ri•, �11 r12231,2`, Y1.' g Harbour Crest, Spiegel Grove,
/ Addison Heights, and Sawmill
' y.I:"a`1rf! . � :! { li i,.•� •_,i;ti y4! Siding
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact•Resisth'r& fro
,? D,esfgn.Preesurec +N/A/-74
fi.11ri N' I Other: Design pressure varies based on the installation
if ,method+';Plea's`e;refer to the evaluation report for the pro
i?} I:•�i{ J�l 'd'esigri pressure based on the installation.
,.✓,.��• „ i Alt."�ri='
�rl.iat'i•1l ,I
Description
D4, DL4, D5 and DL5 Configurations
Installation Instructions
FL12231._,R4 _II.__Installation.Instructions_Attachment Details
2017,-10 06,pdf
FL1223.1R4..._II,._Vinyl_Siding_ Installation.-Manual-2017..pdf
Verified By: NTA, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL12231 R4 AE Evaluation Report STC111111-8 2017-10-
06:pAf
Created by Independent Third Party: Yes
D4, DL4, DL4.5, D5, DL5 and T3.33 Configurations
Installation Instructions
FL1223.1R4_11Installation Instructions Attachment,_Qetails
2017-10 06 pdf
FL1223,1,._R4,. I1.,_Vinyl.-Siding,-Installation,-Manual_ �2017,.pdf
Verified By: NTA, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL12231__R4.._AE.._Evaluation Report STCllil_1.1_-8_,2017_10=
06,p_df
Created by Independent Third Party: Yes
12231.3
Oak Harbor, Bristol Bay and Town'D4,
Square Vinyl Siding
DL4, DL4.5, D5, DL5 Configurations
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12231..R4_11-Installatipn,-Instructions_AttaGhment Details
Approved for use outside HVHZ: Yes
Z017 10 Q6_pd[
Impact Resistant: No
FL12251,R411._Vinyl_-Siding.-In s..tallatio..n-Manual_-2017,,_pdf
Design Pressure: +N/A/-59
Verified By: NTA, Inc.
Other: Design pressure varies based on the installation
Created by Independent Third Party: Yes
method. Please refer to the evaluation report for the proper
Evaluation Reports
design pressure based on the installation.
FL12231,_,_R4„_AE.,._E.Evaluation Report STC111111-8,_2017=10
06 pdf
Created by Independent Third Party: Yes
12231.4 Pro Pride I
DL4.5 Configurations
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL_12231,_,R4_ 11_..lnstallation_Instructio_ns_Attachment._Details
Approved for use outside HVHZ: Yes
2017,-1.0 06.pdf
Impact Resistant: No
Vinyl_Siding.-Insta.11aton,-Manual_-,2017,.pdf
Design Pressure: +N/A/-76
Verified By: NTA, Inc.
Other: Design pressure varies based on the installation
Created by Independent Third Party: Yes
method. Please refer to the evaluation report for the proper
Evaluation Reports
design pressure based on the installation.
FL1223.1R4.._AE_E_v_aluation Report,STClilll_1.. 8.2017-10=
06_pdf
Created by Independent Third Party: Yes
12231.5
Prospan Premium, Dura Span and
T4, DS Configurations
Pioneer Vinyl Siding
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
I EL12231 R4 II Installation Instructions Attachment Details
20A7-10-06.pA
Approved fo,r use outside HVHZ: Yes
Impact Resistant: No
FL12231 R4 II Vinyl-Siding-Installa ion-Manual_2017.pdf
Verified By: NTA, Inc.
Design Pressure: +N/A/-37
Other: Design pressure varies based on the installation
Created by Independent Third Party: Yes
method. Please refer to the evaluation report for the proper
Evaluation Reports
design pressure based on the installation.
F...L.1.2231_„R4_A.E__.E.va.luation_R.eport STGl.l..l._1..1.1 8._2017.=10_,
06,pdf
Created by Independent Third Party: Yes
12231.E : _ t.i Select Series Beaded Siding and Beaded 6.5 Configuration
Lexington Series Beaded Vinyl Siding
W
I�
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/-74
Other: Design pressure varies based on the installation
method. Please refer to the evaluation report for the proper
design pressure based on the installation.
Installation Instructions
F112231_,_R4 „II„_Installation_Instructions_Attachmgnt Details
2017_ 10-06,pdf
FL12231_R4 JUL, HManuali2017.pdf
Verified By: NTA, Inc.
Created by Independent Third Party: Yes
Evaluation Reports
FL12231.,_R4__AE„_Eva.luatio n„Report STCl, l l l,l i,_8, 2017-10
06 P.
Created by Independent Third Party: Yes
12231.7
Select Series Board and Batten and
Lexington Series Board and Batten
Vinyl Siding
Board and Batten Configuration
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12231. R4_ IIInstallation,_Instructions_Attochment Details
Approved for use outside HVHZ: Yes
2017-10 06.pdf
Impact Resistant: No
FL1223.1 _R4 II.,_Vinyl_$id jag.-Installation_Man_u..al_2017,.pdf
Design Pressure: +N/A/-50
Verified By: NTA, Inc.
Other: Design pressure varies based on the installation
Created by' Independent Third Party: Yes
method. Please refer to the evaluation report for the proper
Evaluation Reports
design pressure based on the installation.
FL12231_R4._AE._Evaluation,_Repgrt_SIC111,111_a 2017-1Q
06.pdf
Created by Independent Third Party: Yes
12231.8
Timbermill
D4, S7 Configuration
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12231 R4 II Installation Ingrugtionq Attachment Details
2017-10-06.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
FL12231 R4 II Vinvl_Siding-Installation=Manual-Installation
Design Pressure: +N/A/-72
Verified By: NTA, Inc.
Other: Design pressure varies based on the installation
Created by Independent Third Party: Yes
method. Please refer to the evaluation report for the proper
Evaluation Reports
design pressure based on the installation.
FL12231,__R4__AE__Eva.l_nation_Repor[,STC.1..11.1.1.18._20170=
Q6_pdf
Created by Independent Third Party: Yes
12231.9
Timbermill Log Cabin Panel Siding
Cabin Board (S6.5) Configuration
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12231_R4_II„_Installation„Instructions Attachment Details•
Approved for use outside HVHZ: Yes
2077-10-06.D_cJf
Impact Resistant: No
Design Pressure: +N/A/-100
FL12231 R4 II Vinyl_Sidino-Installation-Manual-2017.Ddf
Verified By: NTA, Inc.
Other: Design pressure varies based on the installation
Created by Independent Third Party: Yes
method. Please refer to the evaluation report for the proper
Evaluation Reports
design pressure based on the installation.
FL12231 R4 AE Evaluation Report STCi11111-8 2017-10-
06.odf
Created by Independent Third Party: Yes
12231.10
Timbermill Vertical Siding
D5 Configuration
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL12231R4_II.„_Installation _Instructions Attachment Details
Approved for use outside HVHZ: Yes
2017-10fi,,pd ,,-Of
Impact Resistant: No
FL12231 R4_II_,Vinyl-Siding_Installation_-Manual_201df
Design Pressure: +N/A/-57
Verified By: NTA, Inc.
Other: 10" oc into OSB sheathing
Created by Independent Third Party: Yes
Evaluation Reports
FL12231 R4 AE Evaluation Report $TC111111-8 2017=10_
06_pdf
Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic
mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275
(1). Florida.Statutes, effective October 1, 2012, licensees licensed under Chapter 455. F.S. must provide the Department with an emailaddress if they have one. The
emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address,
please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F•S., please
click here .
Product Approval Accepts:
el
Safe
0
Installation
U
ns: Attachment Details
able Pressures'-Z
I
Allowable Pressure12 (psf)
Additional Product
Typical
Product Name
Names
Profile
Thickness
Nails'
Staples'
(in.)
16" oc
12" oc
8" oc
16" oc
8" oc
Pro Pride
--
DLI4.5
I
0.038
76
144
69 79,
160
D5
49 psf, 12" oc into OSB
DuraSpan
Prospan Premium
sheathing
___
___
(vertical application)
Pioneer
0.040
37 psf, 12" oc into OSB
I T4
sheathing
—
Alpine Ridge or
D4, DL4
I
120
---
170
78
---
Fairfield
Ridgeview
0.044
ID5, DL5
59
--
122
59
---
Select Series
Lexington Series
Beaded
0.044
74
---
---
---
—
Beaded Siding
6.5
Select Series Board
Lexington Series
Board and
and Batten
Board and Batten
I Batten
0.048
50
--
---
45
---
Spiegel Grove or
D4, DL4,
Harbour Crest
Addison Heights or
DL4.5, D5,
0.040
.74
---
174
108
---
Sawmill I
DL5, T3.33
1654
D4, DL4
120
---
170
78
---
Oak Harbor
Bristol Bay or
0.042
DL4.5, IDS,
Town Square
DL5
59
122
59
Timbermill Log
Cabin
Cabin Panel
---
Board
0.042
100
—
--
---
---
(S6.5)
D4
100
--
---
---
--
Timbermill
---
0.042
S7
72
---
132
---
--
Timbermill
D5
0.042
57 psf, 10" oc into OSB
(vertical application)
sheathing
Allowaoie pressure aeterminea in accordance
D,, = P, /(0.36 x 1.5) • where P, is the avers
1
z Allowable pressure applies to the siding only. I
the structural framing must be designed in acco
' Refer to Section 5.4 for fastener requirements
4 Second value is for Double Stapled at 16" oc.
1 with ASTM D3679-11. Accordingly, allowable test pressures were calculated using the following equation:
ge static test pressure.
-he strength of the structural sheathing, framing, and the withdrawal strength of the specified connectors in
'dance with accepted engineering practice by a registered design professional.
and referenced test reports for additional details of installation.
``````ltJIIIfIT0
G, II N
;�lL`,•• Ci E IVS AD % NTA, Inc., 305 N Oakland Ave
` !.``�__ • V �•.• Nappanee, Indiana 46550
�/ Engineering COA No. 8463
NO 63511 These documents are applicable only to me elements and I oadingcmeria
specifically provided herein. These documents shall not be construed in any
way to specify, certify or design any aspects of the budding not cunbuned
_ herein. Specified design criteria are based solely an information prowded by
the client and must be venfied and approved by me local authority haying
•� A�.rr junsdin.n. NTA. Ine, is not responsible for fabricationf or ere— It is
suspected that mesa documents nave been modified. subStiNled or altered
' S E OF •; ut any way, contact NTA, Inc. at (574) 773-7975 to obtain a file copy.
• 10109117
e1
1. The product illustrated satisfies the requirements for the Florida Building Code Sixth Edition (2017) NOT including
HVHZ.
2. The installation drawings depicted are in accordance with the Florida Building Code and the manufacture's
installation requirements.
3. The products must be installed over a minimum 7/16" wood structural panel sheathing (Plywood or OSB) with an
approved weather resistive barrier placed under the siding
4. Flashing must be installed as necessary at all openings, penetrations or abutments of dissimilar materials as
required by the Building Code.
5. Wood framing installations are assumed to be 2X S-P-F (G= 0.42) or denser. For installation into wood framing use
1-1/2" long 11 Gauge roofing nails or 7/16" X 1-1/2" long X 16 gauge staples
6. The fastener must be able to penetrate not less that % inch into the framing or furring. A 1/16 to 1/32-inch space
shall be between the fastener head (nail or staple) and the face of the vinyl nailing hem, so as not to restrict
movement due to expansion and contraction.
7. Corrosive resistant fasteners shall be used
Q-�C''� C•E•N s O
k No 663511 :• *
s E OF : •_
••• 10/09/17 P ••
Is,' ••.....•• '
NAI L
NTA, Inc., 305 N Oakland Ave
Nappanee, Indiana 46550
Engineering COA No. 8463
These documents are applicable only to me elements and loading crdena
specifically provided herein. These documents shall not be construed in any
way to specify, certify or design any aspects of me building not contained
herein Spenfied design criteria are based solely on information provided by
the diem and must be verified and approved by the local authority having
ryrisaic,on, NTA, Inc. is not responsible for fabrication or erection. If it is
suspected mail these documents have been madified, substituted or altered
in any way, contact NTA, Inc. at (574) 773-7975 to obtain a file copy.
Wall Width
WallIlelght -
B
11111111//j�
:�••..0 E N4'
*�• No63511
ST E OF
i� •'. 10109117 P,••
< O
*,"11 1 1 1 1 1 1 W
SPF woo0 FRAMING SPF WOOD FRAMING \
t 6' oc (Trn.3 is- Oc (TYP.) —\
7/18' SHEATHING —`
(PLYWOOD OR OS8)
— _..................
..........................
—_-- MOISTURE BARRIER
---_-----..."............. 7/16" SHEATHING
_— -- (PLYWOOD OR OSB)
MOISTURE BARRIER VINYL SIDING --
VINYL SIDING
FASTENERS —�
-- (SEE NOTE 5 do
CHART ON PAGE 1)
NTA, Inc., 305 N Oakland Ave
Nappanee, Indiana 46550
Engineering COA No. 8463
These documents are applicable only to ate elements and loading criteria
specifically prowded herein. These documents shall not be canItIved in any
way to specify, certify or design any aspects of the building not contained
herein. Specified design criteria are based solely an information provided by
the client and must be verified and approved by the local authority having
jurisdiction. MA. Inc is not responsible for fabrication or erection. If it is
suspected that these documents have been modified, substituted or altered
in any way, contact NTA, Inc. at (574) 773-7975 to obtain a file copy.
DOW
REVISIONS '0p"
SECTION B-8
STYLE CREST. INC.
.ob KIM., mex
i76r101ff am
VINYL SIDING
rec PKIRLmw OK4M S
raneurnn MMZ
is