Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL PANEL WALLS SIDINGrF• .l BCIS Home Log In ; User Registration 4 Hot Topics Submit Surcharge Slats & Facts E 'Crti�^U{f '¢ Product Approval 6 ' USER: Public User i Product Approval Menu > Product or Application Search > Application List > Application Detail Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email r Authorized Signature I Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Publications FBC Staff BCIS Site Map : Links Search ST. LUCI irnrr� , ry pT r PI►SIO�i REVIEW Ei) FOR COS^ - E W REVIEWED B DATE 3/6 PLANS ANIS PERMIT MUST BE KEPT ON JOB OR NO INSPECTION WILL BE MADE. THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS Style Crest Inc. REQUIRED BY FIELD INSPECTORS THAT 600 Hagerty Drive MAY BE NECENAAY Fremont, OH 43420 Fremont, IN ORDER TO (419) 333-5835 CQMY WITH A" APMABLE lewi s. pope@stylecrest. net CODES. Lewis Pope lewis.pope@stylecrest.net Lewis Pope 600 Hagerty Drive Fremont, OH 43420 (419) 333-5835 lewis.pope@stylecrest.net Lewis Pope 600 Hagerty Dr Fremont, OH 43420 lewis.pope@poly-foam.com =PanelWalls CONCE► o FASZI ERS ORPTACHWE-N-1S ARE THE RESPOHSIB UyOF THE CONi VOR OFRECOM Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Eric J. Tompos P.E. Evaluation Report Florida License PE-63511 Quality Assurance Entity Architectural Testing, Inc., an Intertek company Quality Assurance Contract Expiration Date 12/31/2020 Validated By William R. Heiden III, P.E. Validation Checklist - Hardcopy Received Certificate of Independence FL12231 R4 COI EJT COI.pdf Referenced Standard and Year (of Standard) Standard Year ASITM D3679 2011 • Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect v..,,STC062..717 32 Equiva..lgnce Qf $tandards_2Q17,10_ Q6,pdf Sections from the Code FILF Copy 0 .t Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Ill Method 1 Option D 10/11/2017 11/21/2017 11/28/2017 02/13/2018 .FL 41: S , ,, ; r z ,; `a 1 i I,Moclel, Number or Namel 122311}! {! ?,` ' : ° ' Fairfield, Alpine Ridge and Rid ;Vinyl Siding . .t -' i •i,, � 1,;''.,, i_lmits,-ofUse;: .+jl.,`! •Approved for,.use in HVHZ: No { , f ?• i l ! ?' ' Approverd'for useioufside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-59 Other: Design pressure varies based on the installatior 6,w j" � method.t PI'ease.refer-to the evaluation report for the 1 c : , ,,r:.• d"eslgn pressure based on the installation. .•+ ••, n t 11 J 0 .l r, f`,r•ri•, �11 r12231,2`, Y1.' g Harbour Crest, Spiegel Grove, / Addison Heights, and Sawmill ' y.I:"a`1rf! . � :! { li i,.•� •_,i;ti y4! Siding Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact•Resisth'r& fro ,? D,esfgn.Preesurec +N/A/-74 fi.11ri N' I Other: Design pressure varies based on the installation if ,method+';Plea's`e;refer to the evaluation report for the pro i?} I:•�i{ J�l 'd'esigri pressure based on the installation. ,.✓,.��• „ i Alt."�ri=' �rl.iat'i•1l ,I Description D4, DL4, D5 and DL5 Configurations Installation Instructions FL12231._,R4 _II.__Installation.Instructions_Attachment Details 2017,-10 06,pdf FL1223.1R4..._II,._Vinyl_Siding_ Installation.-Manual-2017..pdf Verified By: NTA, Inc. Created by Independent Third Party: Yes Evaluation Reports FL12231 R4 AE Evaluation Report STC111111-8 2017-10- 06:pAf Created by Independent Third Party: Yes D4, DL4, DL4.5, D5, DL5 and T3.33 Configurations Installation Instructions FL1223.1R4_11Installation Instructions Attachment,_Qetails 2017-10 06 pdf FL1223,1,._R4,. I1.,_Vinyl.-Siding,-Installation,-Manual_ �2017,.pdf Verified By: NTA, Inc. Created by Independent Third Party: Yes Evaluation Reports FL12231__R4.._AE.._Evaluation Report STCllil_1.1_-8_,2017_10= 06,p_df Created by Independent Third Party: Yes 12231.3 Oak Harbor, Bristol Bay and Town'D4, Square Vinyl Siding DL4, DL4.5, D5, DL5 Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL12231..R4_11-Installatipn,-Instructions_AttaGhment Details Approved for use outside HVHZ: Yes Z017 10 Q6_pd[ Impact Resistant: No FL12251,R411._Vinyl_-Siding.-In s..tallatio..n-Manual_-2017,,_pdf Design Pressure: +N/A/-59 Verified By: NTA, Inc. Other: Design pressure varies based on the installation Created by Independent Third Party: Yes method. Please refer to the evaluation report for the proper Evaluation Reports design pressure based on the installation. FL12231,_,_R4„_AE.,._E.Evaluation Report STC111111-8,_2017=10 06 pdf Created by Independent Third Party: Yes 12231.4 Pro Pride I DL4.5 Configurations Limits of Use Installation Instructions Approved for use in HVHZ: No FL_12231,_,R4_ 11_..lnstallation_Instructio_ns_Attachment._Details Approved for use outside HVHZ: Yes 2017,-1.0 06.pdf Impact Resistant: No Vinyl_Siding.-Insta.11aton,-Manual_-,2017,.pdf Design Pressure: +N/A/-76 Verified By: NTA, Inc. Other: Design pressure varies based on the installation Created by Independent Third Party: Yes method. Please refer to the evaluation report for the proper Evaluation Reports design pressure based on the installation. FL1223.1R4.._AE_E_v_aluation Report,STClilll_1.. 8.2017-10= 06_pdf Created by Independent Third Party: Yes 12231.5 Prospan Premium, Dura Span and T4, DS Configurations Pioneer Vinyl Siding Limits of Use Installation Instructions Approved for use in HVHZ: No I EL12231 R4 II Installation Instructions Attachment Details 20A7-10-06.pA Approved fo,r use outside HVHZ: Yes Impact Resistant: No FL12231 R4 II Vinyl-Siding-Installa ion-Manual_2017.pdf Verified By: NTA, Inc. Design Pressure: +N/A/-37 Other: Design pressure varies based on the installation Created by Independent Third Party: Yes method. Please refer to the evaluation report for the proper Evaluation Reports design pressure based on the installation. F...L.1.2231_„R4_A.E__.E.va.luation_R.eport STGl.l..l._1..1.1 8._2017.=10_, 06,pdf Created by Independent Third Party: Yes 12231.E : _ t.i Select Series Beaded Siding and Beaded 6.5 Configuration Lexington Series Beaded Vinyl Siding W I� Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-74 Other: Design pressure varies based on the installation method. Please refer to the evaluation report for the proper design pressure based on the installation. Installation Instructions F112231_,_R4 „II„_Installation_Instructions_Attachmgnt Details 2017_ 10-06,pdf FL12231_R4 JUL, HManuali2017.pdf Verified By: NTA, Inc. Created by Independent Third Party: Yes Evaluation Reports FL12231.,_R4__AE„_Eva.luatio n„Report STCl, l l l,l i,_8, 2017-10 06 P. Created by Independent Third Party: Yes 12231.7 Select Series Board and Batten and Lexington Series Board and Batten Vinyl Siding Board and Batten Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL12231. R4_ IIInstallation,_Instructions_Attochment Details Approved for use outside HVHZ: Yes 2017-10 06.pdf Impact Resistant: No FL1223.1 _R4 II.,_Vinyl_$id jag.-Installation_Man_u..al_2017,.pdf Design Pressure: +N/A/-50 Verified By: NTA, Inc. Other: Design pressure varies based on the installation Created by' Independent Third Party: Yes method. Please refer to the evaluation report for the proper Evaluation Reports design pressure based on the installation. FL12231_R4._AE._Evaluation,_Repgrt_SIC111,111_a 2017-1Q 06.pdf Created by Independent Third Party: Yes 12231.8 Timbermill D4, S7 Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL12231 R4 II Installation Ingrugtionq Attachment Details 2017-10-06.pdf Approved for use outside HVHZ: Yes Impact Resistant: No FL12231 R4 II Vinvl_Siding-Installation=Manual-Installation Design Pressure: +N/A/-72 Verified By: NTA, Inc. Other: Design pressure varies based on the installation Created by Independent Third Party: Yes method. Please refer to the evaluation report for the proper Evaluation Reports design pressure based on the installation. FL12231,__R4__AE__Eva.l_nation_Repor[,STC.1..11.1.1.18._20170= Q6_pdf Created by Independent Third Party: Yes 12231.9 Timbermill Log Cabin Panel Siding Cabin Board (S6.5) Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL12231_R4_II„_Installation„Instructions Attachment Details• Approved for use outside HVHZ: Yes 2077-10-06.D_cJf Impact Resistant: No Design Pressure: +N/A/-100 FL12231 R4 II Vinyl_Sidino-Installation-Manual-2017.Ddf Verified By: NTA, Inc. Other: Design pressure varies based on the installation Created by Independent Third Party: Yes method. Please refer to the evaluation report for the proper Evaluation Reports design pressure based on the installation. FL12231 R4 AE Evaluation Report STCi11111-8 2017-10- 06.odf Created by Independent Third Party: Yes 12231.10 Timbermill Vertical Siding D5 Configuration Limits of Use Installation Instructions Approved for use in HVHZ: No FL12231R4_II.„_Installation _Instructions Attachment Details Approved for use outside HVHZ: Yes 2017-10fi,,pd ,,-Of Impact Resistant: No FL12231 R4_II_,Vinyl-Siding_Installation_-Manual_201df Design Pressure: +N/A/-57 Verified By: NTA, Inc. Other: 10" oc into OSB sheathing Created by Independent Third Party: Yes Evaluation Reports FL12231 R4 AE Evaluation Report $TC111111-8 2017=10_ 06_pdf Created by Independent Third Party: Yes Back Next Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. 'Pursuant to Section 455.275 (1). Florida.Statutes, effective October 1, 2012, licensees licensed under Chapter 455. F.S. must provide the Department with an emailaddress if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F•S., please click here . Product Approval Accepts: el Safe 0 Installation U ns: Attachment Details able Pressures'-Z I Allowable Pressure12 (psf) Additional Product Typical Product Name Names Profile Thickness Nails' Staples' (in.) 16" oc 12" oc 8" oc 16" oc 8" oc Pro Pride -- DLI4.5 I 0.038 76 144 69 79, 160 D5 49 psf, 12" oc into OSB DuraSpan Prospan Premium sheathing ___ ___ (vertical application) Pioneer 0.040 37 psf, 12" oc into OSB I T4 sheathing — Alpine Ridge or D4, DL4 I 120 --- 170 78 --- Fairfield Ridgeview 0.044 ID5, DL5 59 -- 122 59 --- Select Series Lexington Series Beaded 0.044 74 --- --- --- — Beaded Siding 6.5 Select Series Board Lexington Series Board and and Batten Board and Batten I Batten 0.048 50 -- --- 45 --- Spiegel Grove or D4, DL4, Harbour Crest Addison Heights or DL4.5, D5, 0.040 .74 --- 174 108 --- Sawmill I DL5, T3.33 1654 D4, DL4 120 --- 170 78 --- Oak Harbor Bristol Bay or 0.042 DL4.5, IDS, Town Square DL5 59 122 59 Timbermill Log Cabin Cabin Panel --- Board 0.042 100 — -- --- --- (S6.5) D4 100 -- --- --- -- Timbermill --- 0.042 S7 72 --- 132 --- -- Timbermill D5 0.042 57 psf, 10" oc into OSB (vertical application) sheathing Allowaoie pressure aeterminea in accordance D,, = P, /(0.36 x 1.5) • where P, is the avers 1 z Allowable pressure applies to the siding only. I the structural framing must be designed in acco ' Refer to Section 5.4 for fastener requirements 4 Second value is for Double Stapled at 16" oc. 1 with ASTM D3679-11. Accordingly, allowable test pressures were calculated using the following equation: ge static test pressure. -he strength of the structural sheathing, framing, and the withdrawal strength of the specified connectors in 'dance with accepted engineering practice by a registered design professional. and referenced test reports for additional details of installation. ``````ltJIIIfIT0 G, II N ;�lL`,•• Ci E IVS AD % NTA, Inc., 305 N Oakland Ave ` !.``�__ • V �•.• Nappanee, Indiana 46550 �/ Engineering COA No. 8463 NO 63511 These documents are applicable only to me elements and I oadingcmeria specifically provided herein. These documents shall not be construed in any way to specify, certify or design any aspects of the budding not cunbuned _ herein. Specified design criteria are based solely an information prowded by the client and must be venfied and approved by me local authority haying •� A�.rr junsdin.n. NTA. Ine, is not responsible for fabricationf or ere— It is suspected that mesa documents nave been modified. subStiNled or altered ' S E OF •; ut any way, contact NTA, Inc. at (574) 773-7975 to obtain a file copy. • 10109117 e1 1. The product illustrated satisfies the requirements for the Florida Building Code Sixth Edition (2017) NOT including HVHZ. 2. The installation drawings depicted are in accordance with the Florida Building Code and the manufacture's installation requirements. 3. The products must be installed over a minimum 7/16" wood structural panel sheathing (Plywood or OSB) with an approved weather resistive barrier placed under the siding 4. Flashing must be installed as necessary at all openings, penetrations or abutments of dissimilar materials as required by the Building Code. 5. Wood framing installations are assumed to be 2X S-P-F (G= 0.42) or denser. For installation into wood framing use 1-1/2" long 11 Gauge roofing nails or 7/16" X 1-1/2" long X 16 gauge staples 6. The fastener must be able to penetrate not less that % inch into the framing or furring. A 1/16 to 1/32-inch space shall be between the fastener head (nail or staple) and the face of the vinyl nailing hem, so as not to restrict movement due to expansion and contraction. 7. Corrosive resistant fasteners shall be used Q-�C''� C•E•N s O k No 663511 :• * s E OF : •_ ••• 10/09/17 P •• Is,' ••.....•• ' NAI L NTA, Inc., 305 N Oakland Ave Nappanee, Indiana 46550 Engineering COA No. 8463 These documents are applicable only to me elements and loading crdena specifically provided herein. These documents shall not be construed in any way to specify, certify or design any aspects of me building not contained herein Spenfied design criteria are based solely on information provided by the diem and must be verified and approved by the local authority having ryrisaic,on, NTA, Inc. is not responsible for fabrication or erection. If it is suspected mail these documents have been madified, substituted or altered in any way, contact NTA, Inc. at (574) 773-7975 to obtain a file copy. Wall Width WallIlelght - B 11111111//j� :�••..0 E N4' *�• No63511 ST E OF i� •'. 10109117 P,•• < O *,"11 1 1 1 1 1 1 W SPF woo0 FRAMING SPF WOOD FRAMING \ t 6' oc (Trn.3 is- Oc (TYP.) —\ 7/18' SHEATHING —` (PLYWOOD OR OS8) — _.................. .......................... —_-- MOISTURE BARRIER ---_-----..."............. 7/16" SHEATHING _— -- (PLYWOOD OR OSB) MOISTURE BARRIER VINYL SIDING -- VINYL SIDING FASTENERS —� -- (SEE NOTE 5 do CHART ON PAGE 1) NTA, Inc., 305 N Oakland Ave Nappanee, Indiana 46550 Engineering COA No. 8463 These documents are applicable only to ate elements and loading criteria specifically prowded herein. These documents shall not be canItIved in any way to specify, certify or design any aspects of the building not contained herein. Specified design criteria are based solely an information provided by the client and must be verified and approved by the local authority having jurisdiction. MA. Inc is not responsible for fabrication or erection. If it is suspected that these documents have been modified, substituted or altered in any way, contact NTA, Inc. at (574) 773-7975 to obtain a file copy. DOW REVISIONS '0p" SECTION B-8 STYLE CREST. INC. .ob KIM., mex i76r101ff am VINYL SIDING rec PKIRLmw OK4M S raneurnn MMZ is