Loading...
HomeMy WebLinkAboutEVALUATION REPORTQ d .NNE-_ BY 1� 82 Lucie ftnK CBUCK Engineering Sppcic5ftj Structural Jrdl Englnpertnq CBUCK, Inc. Certificate ofAuthorization #8064 ST. LUCIE COUNTY BUILDIN- DIVISI Evaluation Report RETf1mvd., F2EVlE11i ED n col RECEIVED "Ultra HT Wind & Water Sea �� DATE - ZZ / Roof Underlayment PLANS) AN i�BBMIT JAN 16 2MB rrtu �' �� K9PT' ON JOB OF?Manufacturer' Mr? IN�;P@I�I� 5T. Lucie County, MFM Building Products Corp. 57-5 Orange streex THESE PLANS AND ALL PRnPn-qFD W081'; Coshocton, Ohio 43812 ARE Sl1i IECT T q ilk.1,1(;17Pr*(J10NS (740) 622-2645 RFOLIIREi)'VFI�I I7IPJbI' �7(.1(3;; TiIt�T for MAY BE l'lk0ES8k,`)Y IN OPLIPR TO Florida Product Approval C01APV' Vi'Thl Ali, APKX40 f ODES, #FL11842.3R4 Florida Building Code 6th Edition (2017) CONCFALED FASTENERS 08 ATTACHMENTS Method: 1- D ARE THE RESPONSIBILITY OF THE Category: Roofing CONTRACTOR OF RECORD Sub - Category: Underlayment Product: Description: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 17-131-UHT-ER (Revises 15-115-UHT-ER, FL21842.5 R3) Date: 07/09/17 Contents: Evaluation Report Pages 1— 5 "Ultra HT Wind & Water SeaITI" Self -Adhered Underlayment Facsimile of digital copy signed by James L Buckner, P.E. Electronically signed and sealed documents shall comply with the provisions of FAC Rule 61G15-23. * ' • No 31242 .•' �% * � 0= �T, STATE OF 2017.08.2814.49:18-04'00' CBUCK, Inc. dba CBUCK Engineering Phone: (561) 491-9927 • Email: cbuckCd)cbuckinc.net • Website: www.cbuckinc.net Business:1374 Community Dr., Jupiter, FL 33458 • Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062 ff C'e P `? f i CBUCK Engineering Speclaft j Structural Engineering Manufacturer: MFM Building Products Corp. 525 Orange Street Coshocton, Ohio 43812 (740) 622-2645 www.mfmbo.com Product Name: "Ultra HT Wind & Water SeaITM" Product Category: Roofing FL #: FL 11842.3 R4 Date: 07/09/17 Report No.: 17-131-UHT-ER Page 2 of 5 CBUCK, Inc. Certificate of Authorization #8064 Product Sub -Category Underlayment Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d) Product Description: "Ultra HT Wind & Water SeaITM" is self -adhering membrane composed of a white, non -slip cross -laminated polymer film, laminated to a rubberized asphalt adhesive with a split release liner designed for use as a roof underlayment in high temperature conditions. Product Material / Material Type: Styrene Butadiene Styrene (SBS) Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition (2017), Chapter 15. Product Dimension(s) Roll Size: 36 in. x 67 ft. rolls Thickness: 45 mils (nominal) Substrate(s): "Ultra HT Wind & Water SeaITM" has been evaluated for application to the following substrates (Design of support is outside the scope of this evaluation): • Plywood • Dens Deck Installation: General Installation Instructions: "Ultra HT Wind & Water SeaITM" shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. FL #: FL 11842.3 R4 Date: 07/09/17 CBUCK Engineering Page Repoct No.: 3 of 51-UHT-ER SpeclaltLJ Structural EriginsPring CBUCK, Inc. Certificate of Authorization #8064 Performance Standards: The product described herein has demonstrated compliance with: • ASTM D 1970-15a — Specification Self -adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roof Underlayment for Ice Dam Prorealon Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed standards in ASTM D 1970-15a standard version adopted by the Florida Building Code 6+th Edition (2017) for use as evaluated in this report. Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report Scope: This product has been evaluated in compliance with the building envelope requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Product Limitations and • Deck shall be in compliance with applicable building code. Conditions of Use: • Minimum slope shall be 2:12 or greater. • Installation is limited to use with approved roof coverings that are mechanically fastened through the underlayment and is attached to the sheathing or rafters. • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. General Limitations and • SCODe of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under `Optional Statewide Approval'. • Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. • This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is part of the Florida Building Commission approval for the listed code related criteria. This report by James Buckner, P.E. and CBUCK Engineering is FL #: FL 11842.3 R4 Date: 07/09/17 g Page Report No.: 4 of 51-UHT-ER CBUCK Engineerin Specialtiy Structural EriQlneering CBUCK, Inc. Certificate of Authorization #8064 not a design certification of code compliance construction submittal documentation, per FBC section 107, for any individual structure, site specific or permit design. • Design of support system is outside the scope of this report. • Fire Classification is outside the scope of Rule 611320-3, and is therefore not included in this evaluation. • This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof .panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited -by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). Referenced Data: 1. ASTM D 1970-01 Test By PRI Construction Materials Technologies, Inc. (FBC Organization ID# TST 1556) Report No. MFM-039-02-01, Date: 8/15/13 2. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK'Engineermg (FBC Organization # ANE 1916) 3. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) MFM Building Products Corp. Licensee #335 4. Certification of Independence By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) FL M FL 11842.3 R4 Date: 07/09/17 17-13 CSUCIK Engineering Repo: No.5 of 51-UHT-ER Specialty Structural Engineering CBUCK, Inc. Certificate of Authorization u8064 '1MFM Building Products Corp. Ultra HT Wind lip Water Seal Self -Adhered Roofing, Underlaymer General Installation Instructions: • Product to be applied directly to a clean dry surface. • Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer. • Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into place onto roof deck. • Adhesive is pressure -activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or rubber roller to seams and overlap. • Overlap end laps a minimum of 6". Side laps must be a minimum of 3". • Store product in the carton in a dry place until ready to use. Keep product out of direct sunlight. • Apply membrane only in fair weather when the air, surface and membrane are at a minimum temperature of: 50° F • Not to be applied over active solvents or sealants, EPDM rubber or products containing silicone. • Do not expose product to direct sunlight for more than 60 days. "Ultra HT Wind & Water Seal"' shall be installed in accordance with the attached installation method and in compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Limitations and Conditions of Use listed in this Evaluation Report. Refer to installation details at the end of this report. Refer to manufacturer's installation instructions as a supplemental guide for attachment. Product Illustrations ±*ULTRA►, HT WIND & WATER SEAL'