HomeMy WebLinkAboutGENERATORSCANNED av L ie Coo* RECEIVED JAN 31 2018 I— GENERAL' 16/20/22 kW - Permfthin� I GUARDIAN° SERIES Residential Standby Generators Air-Cooled Gas Engine NONE__, INCLUDES: • True Power'"' Electrical Technology Standby Power Rating • Models G007036-0 G007037-0 (Aluminum - Bisque) -16 kW 60 Hz • Two Line LCD Multilingual Digital Evolution'"" Controller (English/Spanish/ i Model G007035-0 (Aluminum - Bisque) -16 kW 60 Hz French/Portuguese) Models G007039-0, G007038-0 (Aluminum - Bisque) - 20 kW 60 Hz TwT f S h O t' A 'I bl Models G007043-1, G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz ro ans er wltc p Ions val a U. 100 Amp, 16 Circuit Switch or ST.LUCIE COUNTY 200 Amp Service Rated Smart Switch. PLAN REVIEW . See Page 4 for Details. Electronic Governor BLDG: Status &Maintenance IntervaliC.Indicators iTE.System 4 Sound Attenuated Enclosure PLUMB: Flexible Fuel Line Connector DATE: Direct -To -Dirt Composite Mounting PaCMECH: DATE • Natural Gas or LP Gas Operation cvus Q 1 • 5 Year Limited WarrantyLISTED v Note: CUL certification only applies to unbundled units and units packaged with • Capability to be installed within 18" (457 mm) the limiUSA onlyt switches. Units packaged with the Smart Switch are UL certified in of a building* *only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Farce engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER- ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5% Total Harmonic Distortion for utility quality power. This allows confident operation of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 %. SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are N1 PROTOTYPE TESTED J NEMA MGi-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILITY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. w GENERAC �t'•3ss ��y�"4�,� .. PROMISE * * Llnk `TOYEP �•e �4RNA� u * &dli M W USA using domes He and &,.I nWits. 16/20/22 kW GENERAC® ` features and benefits a Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid constructidn and added durability provide long engine life. • Electronic ignition/spark advance These features cpmbine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. . • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damagy due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes mot' starting capability. • Automatic voltage regulation Regulates the o�tput voltage to ±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. , , :tv w Transfer Switch (if applicable) • Fully automatic • NEMA 3R • Remote mounting Transfers your Can be installe� Mounts near your v tal electrical loads to.the energized'soufce°of power. inside or outside for maximum.flexibility. existing distribution, panel for simple;aow-cast installation. Evolution'" Controls _ 1• ;t, • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance, status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly mo`1'itors utility voltage, setpoints 65% dropout, 80% pick-up, of standard voltage. • Generator voltage sensing Constantly morjitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified deale . • Engine warm-up Ensures engine( is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week. All�o offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge' to the battery only when needed at varying rates depending on outdoor air temperature. Compatible wit lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains con itant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged ley lacking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied #extured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical ((grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an eIasy, eye appealing installation, as close as 18" away from a building. Installation System • 1 ft (305 mm) flexible fuel line connector Absorbs any enerator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex latti a design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life 16/20/22 kW GENERAL° specifications Generator Made[ 13007035-0, G007036-0, 0007038-0, G007039-0 0007042-1, 0007043-1 G007037-0 (16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity (LP) 16,000 Watts' 20,000 Watts' 22,000 Rated Maximum Continuous Power Capacity (NG) 16,000 Watts` 18,000 Watts' 19,500 Rated Voltage 240 240 240 Rated Maximum Continuous Load Current-240 Volts (LPMG) 66.6/66.6 83.3/75 91.6/81.3 Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Pales 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement (not included) 12 Volts, Group 26R 540 CCA Minimum or Group 35AGM 650 COA Minimum Unit Weight (lb/kg) 406/186 448/203 466/211 Dimensions (L x W x H) in/mm 48 x 25 x 29/1218 x 638 x 732 Sound output in dB(A) at 23 ft (7 m) with generator operating at normal load" 66 66 67 5 min 5 min Engine Type of Engine GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/ Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magn`eto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1� Starter 12 Vdc 12 Vdc 12 Vdc Oil Capacity Including Filter Approx.1.9 gV1.8 L Approx.1.9 qt/1.8 L Approx.1.9 gU1.8 L� Operating rpm 3,600 3,600 3,600 Natural Gas ft3/hr (m3/hr) 1/2 Load 218 (6.17) 204 (5.78) 228 (6.46) Full Load 309 (8.75) 301 (8.52) 327 (9.26) Liquid Propane ft3/hr (gal/hr) [I/hr] 1/2 Load 91.6 (2.52) [9.53] 86 (2.37) [8.991 92 (2.53) [9.57] Full Load 106.8 (2.94) [11.111 129.6 (3,56) [13_48] 142 (3.90) [14_77] Note: Fuel pipe must be sized for full load. Required fuel pressure to generator fuel inlet at all load ranges - 3.5-7° water column (7-13 mm mercury) far natural gas,10-12" water column (19-22 mm mercury) for LP gas. For Btu content, multiply ft3/hr x 2500 (LP) or f0kr x 1000 (NG). For Megajoule content, multiply m3/hr x 93.15 (LP) or m3/hr x 37.26 (NG) Controls 2-1-ine Plain Text Multilingual LCD Display Simple user interface for ease of operation. Mode Buttons:Auto Automatic Start on Utility failure. 7 day exerciser. Manual Start with starter control, unit stays on. If utility fails, transfer to load takes place. Off Stops unit. Power is removed. Control and charger still operate. Ready to Run/Maintenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500 seconds Standard (programmable by dealer only) Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning Standard Run/Alarm/Maintenance Logs 50 Events Each Engine Start Sequence Cyclic cranking: 16 sec on, 7 rest (90 sec maximum duration). rStarter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Automatic Low Oil Pressure/High Oil Temperature Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator maybe higher depending on installation parameters. Rating definitions -Standby. Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (AlI ratings in accordance with BS5514, IS03046 and DIN6271). *Maximum kilovolt amps and current are subject to and limited by such factors as fuel Btu/megajdule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.6 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 °F) above 16 °C (60 °F) 16/20/22 kW Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included, • Electrically operated, mechanically -held contacts for fa connections • Rated for all classes of load,100% equipment rated, b( resistive. • 2-pale, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both capper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist u • NEMA/UL 3R aluminum outdoor enclosure allows for it mounting flexibility. • Multi listed for use with 1" standard, tandem, GFCI and Siemens, Murray, Eaton and Square D for the most fle) tive install. Dimensions Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 GENERAC® switch options Model G007036-0 (16kW) No. of Poles 2 t, positive Current Rating (Amps) 100 Voltage Rating (VAC) 120/240,10 Utility Voltage Monitor (Fixed)* h inductive and -Pick-up 80% -Dropout 65% Return to Utility* approx.15 sec Exercises bi-weekly for 5 minutes*t Standard JULListed Standard Total Circuits Available 24 dding and Sticking. Tandem Breaker Capabilities 8 tandems IOOr Or OUtd00f Circuit Breaker Protected Available RMS Symmetrical Fault Current @ 250 Volts 10,000 4FCI breakers from *Function of Evolution Controller ble and cost effec- Exercise can be set to weekly or monthly Wire Ranges Conductor Lug Neutral Lug I Ground Lug 1/0 - #14 2/0 - #14 1 2/0-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standan • Intelligently manages up to four air conditioner loads witl hardware. • Up to four more large (240 VAC) loads can be managed conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast • Rated for all classes of load,100% equipment rated, botl tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist we • NEMA/UL 3R aluminum outdoor enclosure allows for ind ing flexibility. Dimensions 200 Amps 120/240,10 Open Transition Service Rated Height Width H1 H2 W1 W2 Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 343.0 175.4 DEPrH Model G007037-0 (16 kW)/6007039-0 (20 kW)/ (DPM). 0007043-0 (22 kW) No. of Poles 2' no additional Current Rating (Amps) 200 VoltageAating (VAC) 120/240,10 hen used in Utility Voltage Monitor (Fixed)* -Pick-up i 80% -Dropout 65% clean connections. Return to Utility* approx.13 sec inductive and rests- Exercises bi-weekly for 5 minutes* Standard UL Listed Standard Enclosure Type NEMA/UL 3R Circuit Breaker Protected 22,000 - Lug Range 250 MCM - #6 ling and sticking. or or outdoor mount- Function of Evolution Controller Exercise can be set to weekly or monthly DEPTH GENERAC 16/20/22 kW available accessories Model # Product Description The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon- G007005-0 Wi-Fi LP Fuel Level Monitor Boring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected powerfailure. Status alerts are available through a free application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change in the generator's status occurs. Available in the U.S. only. G005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). G007101 0 Battery Pad Warmer The pad warmer rests underthe battery. Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil filter. Recommended for use if the temperature regularly falls below 0°F. Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load G005621-0 Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0 - Bisque (Standard on 22 kW) sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from G005703-0 - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities. It provides additional power management flexibility not found in any other power management system. dimensions & PCs Dimensions shown are approximate. Refer to installation manual for exact dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. n5A tit LEFT'SIDE VIEW 148A M FRONT VIEW Model UPC G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 G007038-0 696471070385 G007039-0 696471070392 G007042-0 696471070422 G007043-0 696471070439 GENE RAC® Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02017 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Part No.10000000194-F 5/3/17 Mode! Goo6873.0 DESCRIPTION LIM Gerterac's Smart Power Management System Is designed to optimize the performance of a standby generator. the system can consist Smart Management Modules (SMM}, tlniike other toad management systems that depend on another control device, the c n modules Osumi Individual ndvi3 ual aware and operate autonomously. actually Frequency Is the true measure of generator engine performance and dons not need to factor In increased ambient temperatures, elevation changes or threshold, fuel type. The lladalM Monitor t the frquency (Hz) of the power being produced by generac's standby generators and It It talcs below a certain threshold, the module will automatically follow a pother management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-0 or be set In a NO Out only mode for loads that 111st Slmpiy do not need to tun In an outage, therefore reducing the necessary size of the generator for a more cost effective solution. BRIM MG6F8CAT10A93 - Power Supply Source ............ . Supported Voltages...................................:.................................................................................•.................I............. .... ......_............. ... Contactor Coll Voltage.:....................................................... ....•.".,..,.......................... .... .................................. ............ ...,................240 VAC {from Une Input) or Coil VA lnNSh.. •. ....... ........................ ............................................................................. .„.............I.... ................240 VAC CoilVA Sealed..........................................................................................................................• �........................ ......,..............240YAC Poles.....................•............................................................. ...„+.................. ...................... .......................................................•..............................................................................,............................,....,........ S:2 ResrsU�e Amps .......................... ....... ... . F/LlnducUveAmps.......... ..............•.....................................•..............,..................,.,......................I.................�......... - ,.. 2 Looked ctivaAmps..............................•................................................,.....................................................,.....................•_........ .................,........... .....,......,..60 10 Looked ..........•................... ................_.............. .... 40 Enclosure Rating ............... ................................................•.........•.............•........ . . Yes ...,... ,.... ............................."......NEMASR A. Model GOON780 ON ((Nmm) H� H2 6.77/168.8 2.8WO Wi W2 7.OBf179.4 4.72n20 Depth (Wmmj 8.7/94 we�g� ��gn�teg� zoe�osa � sidpong welght.pbs/tdlos) 2A4n.11 � UPC Code 6S6alaffirm 8MM Controls (located OP-NERAG' NEW Dimensions and UPC W1 i D9 o I' iehind the never of the module) f' B C + cBoGN4LOAo cotuaE9T>3D LEDRASMi9=LOADSN p1iWRIfY LGoxaur ED e LOAD an LWF[A98SS=3oMINLOOKOUr 3 7 GENERATOR i.EDkYAA SS- GENLOADLOOKMAr �"�' LED OFKaHOMODULEPOTNEK O 0 i' 0 LOOKOUT 7ESL DISABLED r Pdodg ml (A) — sets module priorily, Lockoul 8rVw (8) — Roy" load kom operating when system is operaling under generdw power. Teel DuUon (C) — Disables conlaclar ouipul for a specified Ume. LED (b) _ PmNdes module slelus v ith easy vlaMrig through the eztemel vierdng window totaled In the upper rigid comer of the module. Generac Power Systems, Inc. o so w29290 HWY. 59, Waukesha,V153189 a genermoxom ©2016 e020F40f 481erns,lao. Aldghlsreserved. All speoit7oOnsamoubjeAtoMania iul imdnolm SWteht MIGON OM0119 Site Selection and Preparation �vcbon 3: Site Selection and Preparation sit® seiectlon O� gft(1.52m) 3 ft (0.91 m) (DF R-gure 2-9. Installation Clearances [D Description Comments A Top of generator — t3 Front and end clearance Minimum clear distances cannot Include shrubs, bushes, or trees. C Rear clearance 98 in. 08.7 cm) minlmum cl®amnce per NFPA testing, labeling, and llsung, unless state Or local codes dlciate otherwise. D Windows and openings No operable windows, doors, or openings in the wall are permitted within 6 ft (1.62 m) from any point of the generator. E Ddsong wail One -hour fire rated walls allow closer'placement of the generator set. Confirm before Installation. F Removable.fence Removable fence panels for servicing cannot be placed less than 3 R (0.91 m) In front ofthe generator. G Overhead clearance Eft (1.62 m) minimum distance from any structure, overhang; or projections from the wall. DO NOT instals under wooden decks or structures unless this distance Is maintained. Installalion Guidelines For 60 Hz Air -Cooled Generators 11 Site Selection and Preparation Install the generator set, In Its ,protective enclosure, outdoors where adequate cooling and ventlMing air is always available (.== a,::a ;), Consfd8r these factors: The installation of the generator must comply strictly with 1CC 1FGC, NFPA 37; NFPA 54, NFPA 68, and NFPA 70 standards. ° install the unit where air inlet an6 outlet openings Will not become obstructed by leaves, grass, snow, etc, if prevailing winds wit! cause blowing, or drlffing, consider using a windbreak to protect the unit. Install the generator on high growl levels will not rise and endanger it. I - not operate in orbe subjected to st Allow suffclent room on all sides o for maintenance and servicing: Tht; Installed In accordance' with any l, national codes fbr MINITIUM dfsfancl structures. ° Clearance from the -ends and front of must be 3 ft (0.91 m). This inch bushes, and trees, 'Clearance .from tH generator must be a minimum of 1a . Clearance at the top should be a mill (1,62 m) from any structure, projections from the wall, oy DO NOT Install under wooden decks c unless there is at least 5 ft (1.62 m) c above the generator install the unit Where rain gutter down e ruts-oti, landscape irrigation, water sp, SUMP pump discharge does not flood i spray the enclosure, 'Including any air int openings. ° Install the unit where services .will not b or obstructed, Including concealed,. and or covered services such as electrical, fu, air conditioning, or Irrigation. This cot warranty coverage. ° Where strong prevailing winds blovr fi direction, face the generator air inlet ope the prevailing winds. Install the generator as close as possible tc supply to reduce the length of.plping. REM THAT LAWS OR CODES MAY REGUL.K, DISTANEE ANp LOCATION, In the absi local codes regarding placement or clearal recommend following these guidelines: - Install the generator as close as possible i transfer switch. REIVISMBER THAT LAWs CODES MAY REGULATE THE DISTANCE LOCATION. 12 I where water his unit should iding water. the generator unit must be cal, state, or is from other ie generator les shrubs, back of the (467 mm), rum of 5 ft raang, or structures clearance ours, roof skiers, or e unit or or outlet Affected ground, phone, I affect m one ings to The generator must be installed on a level sur. face. The.generator must be level within a 0.5 in (13 mm) all around. — The generator is typically placed on pea gravel, compacted soil, crushed stone, or a concrete Pad- Check local codes to see What.type Is required. If a concrete pad is required, all appli- cable codes should, be followed, .Installation Guidelines for StationaryrAlr-Cooled Generators NFPA 37 Is the The National Flee Protection Association's standard for the lnstallatlon and use of stationary combustion engines. Its requirements limit the spacing of an enclosed generator set from ;a structure or Wali NFPA 37, Section 4,1,4, Engines Located Outdoors' Engines, and their weatherproof housings, it pro that are (retailed outdoorsv)ded, shall be located at least 5 ft (1.52 m) from openings In walls and at (east-8 ft (1.62 m) from structures having combustible Walls. 'A minimum separation shall not be required where the following conditions exist; 1 • The adjacent wall of the structure has a fire resistance rating of at feast one hour. 2. The weatherproof .enclosure is constructed of noncombustible materials and if has demonstrated that a Tire Withln the enclosure will not Ignite combustible materials outside the enclosure. AnnexA — Explanatory Material A4• 1.4 (2) Means of demonstrating co means of full scale fire test orby calculat n pro a are by Because of the limited spaces that area e1uy available for nstai[atlon, it has become apparent that exception (2) would be beneficial ;for many residential and commercial Installations, iMfh that in mind, the manufacturer contracted with an -independent testing laboratory to run full scale fire tests to assure that the enclosure will not Ignite combustible materials outside the enclosure. AIOTE: Southwest Research Institute testing approves �a fuel 18 in (457 mm) 'Insta!latlon minimum from structure Ni3ER C). southwest Research institute is a THE natlonally recognized third party testing and listing ce a agency, e, we The criteria was to determine the worat;ease fire scenario the within the generator and to determine. the Ignitability of RR items outside the engine enclosure at varlous distances. AND The enclosure is constructed of non-combustible h, aterials, and the results and conclusions from the Wependent testing lab Indicated that ,any fire within the lnstailaifon Guidelines For en ia� o�rr.,,,�.,., .,_.. _ generator enclosure would not pose any ignition risk to nearby combustibles or structures, with or without Tire servioe personnel response. wR� +uors s l$o e� � eM� WM7RDaft c�rac F offlm, = F/gure 32. Southwest Research Institute Niarking Based on this testing and the requirements of iYFPA 37, Sec 4.1.4. the guidelines for installation of the generators listed above are changed to 18 In (467 mm) from the back side of the generator to a stationary wall or building (C). For adequate maintenance and all low clearance, the area above the generator should be at feast 5 ft (1.62 m) with a minimum of $ ft (0.91 m) at the front and ends Of the enclosure. This Includes trees, shrubs, and bushes. Vegetation not In compliance with 'hese clearance parameters could obstruct air flaw in addition, exhaust fumes from the generator could inhibit plant growth. See S and the Installation drawing within the owner's manual for details. Automatic start-up. Disconnect uiil(fy pourer and render unit Inoperable before working on unit. Failure to do so will result in death or serious Injury. (000191) Asphyxiation. Running englnes produce, carbon monggoxide, a Colorless, odorless a oided,s6nouwiilreszlI Inodeath orserious , ous Injury. (000103) NOTE: If the generatorls not.set to OFF, It can crank and start as soon as the battery cables are connected. if the Utility power supply is not turned cA sparking can occur at the battery posts and cause an explosion. Site Selection and Preparation Site Preparation ° Locate the mounting area as close as possible t the transfer switch and fuel supply. Leave adequate room arourid the area for servic( access (check local code), and place high enougt to keep rising water from reaching the generator. ° Choose an open space that will provide adequate and unobstructed airflow, Place the unit so air vents won't become clogged with leaves, grass, snow, or debris. Verify .that exhaust fumes will not enter any building through eaves, windows, ventilation fans, or other air Intakes,(see Select the type of base, such Qs --but not limited to—Oompacted $oH, gravel, or concrete, as desired or as required by local laws or codes. Verify your local requirements before selecting. Material Sufficient for Level Installation ° Prepare a rectangular area approximately 5 In (127 mm) deep (A) and approximately B In (152 mm) longer and wider (B) than the footprint of the generator. Verify that the surface where the generator will be mounted is compacted, leveled, and will not erode over time. A concrete pad can be Poured- If desired or required. Figure 3-3. Compacted Sol] or Gravel pad NOTE.' If a concrete pad Is required, follow all applicable federal, state, or local codes. • ,-vi vv nz rw-vooieq Generators 13