HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFFL #
FL20378-RI
THESE' PLANTS AND ALL PROP05-50 laVOR'Iv
Application Type
Revision
' Code Version
2017
ARSE. SUBJECT TO ANY Gil;?PIEC; 7 INN
Application Status
Approved
REQUIRED BY FIELD INSPECTORS I fi:;I
irIXY B NECCS "Ifs ORDER TO
Comments
❑
GGF�i7Ef ��/iThl ALL APPLIvk 3LE CGilES.
Archived
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
Flvalidation@yahoo.com
Authorized Signature
Richard McKuhen
flvalidation@yahoo.com17
4 - 0.50
Representative
Richard McKuhen
v
Address/Phone/Email
2160 SW Poma Drive
ST. LUCIE COUNTY
Palm City, FL 34990
BUILDING DIVISION
(772) 872-8034
REVIEWED
rchard@emfab.net
FOR COMPLIANCE
REVIEWED BY
Quality Assurance Representative
DATE o2D
Address/Phone/Email
PLANS AND PE}' IT
MUST BE KEPT OITJOB OR
Category
Roofing
NO INSPECTION WILL BE MADE
Subcategory
Metal Roofing
Compliance Method
Evaluation Report from a
Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report i
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
EZ Validation Checklist - Hardcopy Received
Certificate of Independence FL20378 R1 COI FL 20378.1 NAILSTRIP 1.0 .032 ALUM sss.odf
Referenced Standard and Year (of Standard) Standard Year
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
h4: //www. floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEV XQwtDqua%2flMZ 8n5 C... 2/5/2018
Florida Building Code Online
Page 2 of 3
Product Approval Method
Method 1 Option D
Date Submitted 08/18/2017
Date Validated 12/18/2017�
Date Pending FBC Approval 10/17/2017 Py
Date Approved 12/19/2017 S
Summary of Products
FL # Model, Number or Name Description
20378.1 01 - "1" Nailstrip" 0.032" Aluminum Standing Seam roof panel, 12" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378 R1 II FL 20378.1 NAILSTRIP 1 032
Approved for use outside HVHZ: Yes ALUM sss.odf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378 R1 AE FL 20378.1 NAILSTRIP 1.0 .032
instructions. ALUM sss.odf
Created by Independent Third Party: Yes
20378.2 02 - "1" Nailstrip" 26-gauge Steel Standing Seam roof panel, 16" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners and adhesive.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FI..20378 R1 TI FI- 20378.2. Extreme Metal Fabricators
Approved for use outside HVHZ: Yes 26GA NAIL STRIP 1.0.odf
Impact Resistant: No Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and Evaluation Reports
Conditions of Use. Refer to manufacturer's installation FL20378 R1 AE FL 20378.2 Extreme Metal Fabricators
instructions. 26GA NAIL STRIP 1.0.odf
Created by Independent Third Party: Yes
20378.3 03 - "1.. 5 Snap Lock" 0.032" Aluminum Standing Seam roof panel, 18" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378 R1 II FL 20378.3 SNAP LOCK ALUM 1.75-ssr.odf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FI-20378 RI AE FL 20378.3 SNAP LOCK ALUM 1.75-ssr.odf
Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes
instructions.
20378.4
04 - "1.75" Snap Lock"
24-gauge Steel Standing Seam roof panel, 18" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 R1 II FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378 RI AE FL 20378.4 1.75 SNAP LOCK 24GA-
ssr.odf
Conditions of Use. Refer to manufacturer's installation
instructions.
Created by Independent Third Party: Yes
20378.5
05 "Rib Panel"
29-gauge Steel exposed fastener roof panel, 36" wide,
mechanically attached to 15/32" plywood or Wood Deck with
fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 R1 II FL 20378.5 RIB 29GA ssr.odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Limitations and
FL20378 RI AE FL 20378.5 RIB 29GA ssr.odf
Conditions of Use. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
http://www.floridabuilding.org/pr/Pr,�app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5 C... 2/5/2018
Florida Building Code Onli : e:, Page 3 of 3
26-gauge Steel exposed fastener roof panel, 24" wide,
mechanically attached to 15/32" Plywood or Wood Deck
w/fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 R1 II FL 20378.6 5V Crimp sss.Ddf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for Method 1 and Method
FI-20378 R1 AE FL 20378.6 5V Crimp sss.Ddf
2 fastening. Limitations and Conditions of Use. Refer to
Created by Independent Third Party: Yes
manufacturer's installation instructions.
20378.7 107 - "1.5 Standing Seam"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer's Installation
instructions.
20378.8 108 - "Nordman Tile"
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for Limitations and
Conditions of Use. Refer to manufacturer's installation
instructions.
24-gauge Steel Standing Seam roof panel, 16" wide,
mechanically attached to 15/32" plywood or Wood Deck with
panel clips, fasteners and adhesive
Installation Instructions
FL20378 R1 II FL 20378.7 JM STANDING SEAM ssr.pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL20378 R1 AE FL 20378.7 JM STANDING SEAM ssr.pdf
Created by Independent Third Party: Yes
24-gauge Steel metal roof tile panel mechanically attached
to 15/32" plywood or Wood Deck with fasteners
Installation Instructions
FL20378 R1 II FL 20378.8 NORDMAN TILE 24GA ssr.pdF
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL20378 R1 AE FL 20378.8 NORDMAN TILE 24GA ssr.pdf
Created by Independent Third Party: Yes
20378.9
09 - "Nordman Tile"
24-gauge Steel metal roof tile panel mechanically attached
to Steel Deck with fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL20378 R1 II FL 20378.9 Nordman Tile Details-ssr.pdf
Verified By: James L. Buckner, P.E. @ CBUCK
Approved for use outside HVHZ: Yes
Impact Resistant: No
Engineering P.E. #31242
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Limitations and
Evaluation Reports
Conditions of Use. Refer to manufacturer's installation
FL20378 R1 AE FL 20378.E Nordman Tile Dct�lls ssr.Af
Created by Independent Third Party: Yes
instructions.
20378.10 10 - "Nordman Tile" 0.032" Aluminum metal roof tile panel mechanically attached
to 15/32" plywood or Wood Deck with fasteners.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL20378 R1 II FL 20378.10 NORD TILT .032 ALUM-ssr.pdf
Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A Evaluation Reports
Other: Refer to evaluation report for Limitations and FI-20378 R1 AE FL 20378.1.0 NORD TII.:f .032 ALUM -
Conditions of Use. Refer to manufacturer's installation 51;r L( f
instructions. Created by Independent Third Party: Yes
Back Next
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida Is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emalls provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
® k M
Creditf
Sate
sGCui ilymu-mim
http://www.floridabuilding.org/pr/P _app_dtl.aspx?param=wGEVXQwtDqua%2flMZ8n5C... 2/5/2018
1.
2160 SW Poma Drive
Palm City, Fl. 34990
872-8034
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec.1507.4.3
Yield strength: 40ksi Steel Attached to min.15/32" plywood or Wood Deck w/ min.
Attached 24" 0.42 specific gravity with screws. 24" Coverage
Coverage Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1506,1507
Fastener for Method 1 Attachment # 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16" thru wood decking
Fastener for Method 2 Attachment # 9-15 x 1" Hex Head w/EPDM Bonded Steel Washer
to penetrate 3/16" thru 15/32"min. plywood deck or 5/8" into wood plank
Underlayment: To be compliant with FBC Sec.1507.1.1
C COPY
.fl....c :.n
Slope: Shall be in compliance with FBC Sec. 1507.
Install Details: Table A Allowable Loads METHOD 1 METHOD 2 FASTENER PLACEMENT
DESIGN, PRESSURE* -85 PSF 114.25 PSF METHOD i IN RIa PEAKS
I. ROW SPACING 12" O.C. 12" O.C. , METHOD 2IN PANEL FLATS_
FASTENER SPACING 12" O.C. 12" O.C. *SEE INSTALLDRAWINGS
FASTENER SIZE: _. _ _ #9 - #9
*ALLOWABLE DESIGN PRESSURE MARGIN OF 2 T01
Reference Data: HURRICANE TEST LAB #TST ID: 1527
TAS 125-03 Test # 0223-0307-01; METHOD 1 (UL 1897-041)
TAS-125-03 Test # 0223-0517-06, METHOD 2
EQUIVALENCY UL 1897-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD DESIGN PRESSURE SAFETY MARIGIN 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a financial interest in any company mal
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer,
report.
0%111 OF
ONIM
Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017
61h ed., with referenced documents submitted.
Limitations:
1. Underlayment to be compliance with current Florida Building Code 2017 6t' ed-Section 1507.1.1
2. Products are compliant for State of Florida product approval per Rule 61G20-3
3. Compliance Method: 1-1)
4. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
5. All support framing compliant w/ Florida Building Code 2017, Chapters 22 for Steel, 23 for Wood and 16 for
Structural Loading. Design of support and attachment to the framing is outside the scope of this evaluation.
6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for "project specific approval' by local
authorities, authorized by the code, and is the responsibility of others.
7. This report does not imply warranty, installation, recommended product use outside of this report.
gr-1 rc —
\--.-'Deck:
15=' or greater Plyo*W,;Or
- wood plank
-15/32" or greaterPly►aood, or
- Wood plank