Loading...
HomeMy WebLinkAboutPRODUCT INFORMATIONS.Olar' • • Sol tEdge Single Phase lnverters For: Nor:th�America t SE3000A-US / SE3800A-US / SE500'OA-US / SE6000A-US / SE760OA-US / SE1000.OA�US / SE1140OA-US HL a 5 . 1 5 f [` ` i The.b,est choice for SolarEdge eln:abled systems ! .Integrated arclauIt protection (Type 1) for NEC 2011690 11 compliance Superior efficiency (98%)' small, lightweight and easy to.install on provided bracket { — Built in�module Ievel:monitoririg ? Internet connection fihrough:Ethernet or Wireless Outdoor• and intloor'installation r Fixed' -voltage inverter�DC/AGconVer§,ion only:- ._Pre assembled. Safety Svvrtch:.for faster•mstallai�on .,, ' :Optional revenue grade data'ANSI;C12`1 USA - GERMANY - ITALY -:PRANCE -JAPAN - CHINA - AUSTRALIA -THE NETHERLANDS - ISRAEL, www.solaredge.us Solar Sing' lePhase.-Inverters forNorth America SE3000A-US-/.SE380OA"US:/:SE5000A=US / SE6000A-US SE7.60OA-US /:SEIOOOOA-.US / SE1140OA7US -P r Z1t:0UUUA-U2k 1--ZIL1 UUA7 .,btlqUUUA-�,Vb,'l�,btll4uuiv-,u j:, IaUUWWO,�?l -DUUUA 0 L!b .:sm: !�OUTP!IjT' w.' o: � Nominal AC Power Outp . Ut 3000 3800 5000 6000 7600 9980.9 208V 11400 VA ...........I ................... .. ........... I ... ... .... ... ........ ................ . 10000#�?!q\( . ......... . .......... Max. AC Power.Output 4.150 - 5400 @ 208V 6000 8350 , 6 208V, 1 �dg6 12000. VA ...................................... ............... ....... I ...... . ........... ............... 1095@ P.Q.Wy.: ................. ........... AC Output Voltage, M in.-Nom.:M ax.(1) V ................... ................ ............... ........ I ....... ................ ................ . AC Output Voltage MinAom.-Max.(1.) v 211 - 240 - 264 Vac ... I .. ............................... AC nuency.MinAom.-Mzix.(1) ..... ...... ........................ ................ ............. .......................... ....... ...... ................ 5.9.3 - 60 - 605:(vvith HI country setting'57 -:60.- 60.5)' ...... .... ... ... z Max. Continuous Output Current 12.5 16 ! 24 208V 2S: 32 1 ................. 47.5 ........... A .... .... I ...................... ..... .. .............. .. ................ ......... 4 .... ................. ..... F6 ............. - I ..................... ................................................................... .................................................... A Utility Monitoring:, Islanding Protection, Country. Configurable Thresholds Yes ... Yes Recommended Max. DC Powee(2j I I ............ 3750 .... ............ 4750 L ............ 6250 7500 9500 I .......... I .......... ........ ....... 12400 .......... a ...... 14250 .............. W .......... ..Trans!?n�r. yqffquqAl:d ....... ..................................................... As ............................................................. ..M�.x. ........... Input Voltage............... 500 .......... Vdc Voltage: ... .. ....... 3 25 @ 20 8V 850 @ 240 V: ................ ............... c Max. input Current(l) ............ 9.5., I 1 3 I [",­­­­ 3 4. 5 ---- A dc .. ........................ ..... ... .... Max. input ShortCircuit Current: ....... I ........................... ........... ... 4.5 ............. I ............. ......... A.dc.... verse-PolarltV protection e.. ; ............ ;.? ..................... ........ .......................................................... Yes ....... .......... ........................... I a ... ..�ro.und.-Fau!t. Isolation Detection ...... .... t I 600ka Sensitivity ............ .......................... .... ........... _Maximum Inverter Efficiency. ..................................... ...... ...... ...... ?� ....... CEC Weighted:Efficiency 97.5 97.5 @ 208V . 97:5 97:5 ................. ................. 97.@'208V 97.5 % . ........... ......... . ..... ......... .. ................ 4�-q .. .. .................. ........... Nighttime r Consumption < 2.5 <'4 W LADDITIONA,L FEATURES,— Supported Communidation Interfaces ......................................... ................. .................. RS485, RS23.2l Ethernet, ZigBee:(optional)' ................................................................................... . ......... Revenue Grade; Data,:ANSI C121 .................................... ........... ............. ;; ............... Q0,tionaI(')' ................................................ ................ ......... ....... ........... Rapid Shutdown - NEC 2014 690;12 Functionality:enAbled I when SolarEdge rapi&shutdown kit is installed(') STANDARD COMPLIANCE, SafetyUL1741 ............. I,UL1699BI UL1998 , CSA 22.2 ................................................... ............................ ............ Grid Connection Standards. ........................... ...................... IEEE1547. ......... ... 111.1 ...... ................ ............ I ........... ............. Emissions 'FCC t)artlS class B INSTALLATION SPECIFICATIONS AC.o.utpyt.conduit size AWG .range .. 3/.4"..mi.h.imum./..167.6..AW.G ..................... 3/4".m.in.imu.m./..8.-3 A ./.................... .............. input conduit:size /# of strings 3/4" minimum / 1-2 strings 16-6 AWG ............ 3/4" minimum 1-2 strings 14-6 AWG ..................... ...... ................ .............. .......... ...................................................... Dimensions with Safety Switch 30:5 x x 12.5 x, 7.5 / 30.5 x 12.5 x 10.5 / 775 x 315 x 260: JI)xWnp) .................................. .775.x.315.x172 ....... 775 x 315 x 191 ........................ ­ ........ I ...................................................... Weight.with a.f.e.t. v .S.w...i.tc..h..., .......... 1...23.2...I 54;7:/ 24.7 ....... ;............................. . 88.4/40.1 ........ ..........5..1..2.. Cooling ........................... ..................... Natural Convection ........................... ........... . ................... Fans. ............. ........ ............................ ..... I ......... ................ ........................... ... ....................... - < 5.0 ...Noise I Min. -Max. Operating Temperature -,13 to +140 -25 to +60 (-40 to +60 ....................... version.available(61) .3?Rgq ..................... I ........... .. I ............................. .................................................. I .......................... ProtectionRating ....... .................. .............................. N E.M.A.3 R ......................................... .............. ('� For other regional ease contact SolarEdge support., Limited to 125% for locations where the. yearly y average high . temperature is above:7.7'F/25*C and io 145Y for locations where It Is below 77*F/25'C. For detailed Information;refer to p://www,solaredge.us/files/�i3dfs/inverter do oversIzInL guldexcIf A higher current source may be used; the Inverter will limit Its input current to the values stated. (4k Revenue grade inverter P/N: SExxxxA.US000NNR2- Rapid shutdown kit P/N: SE1000-RSD-SI -40 version.P/N::SExxxxA-USQQ0NNlU4 GENERAL NOTES: 1. THE FOLLOWING DOCUMENTS DO NOT PERMIT CONTRACTOR TO INSTALL THIS SYSTEM AGAINST ANY LOCAL, MUNICIPAL, OR INTERNATIONALLY RECOGNIZED BUILDING / ELECTRICAL CODE. THE PURPOSE OF THESE DOCUMENTS IS TO PROVIDE AUTHORITIES HAVING JURISDICTION AND UTILITIES A METHOD FOR INSPECTION. 2. THE FOLLOWING DOCUMENTS ARE PROPERTY OF MAXIMO SOLAR INDUSTRIES. ALL DESIGNS AND INFORMATION CONTAINED WITHING THE DRAWINGS ARE ONLY FOR THE SPECIFIED PROJECT AND SHALL NOT BE USED FOR ANY OTHER MEANS. USE OF THE DRAWINGS FOR ANY OTHER PURPOSE IS PROHIBITED WITHOUT EXPRESSED WRITTEN CONSENT OF MAXIMO SOLAR INDUSTRIES. 3. IN THE EVENT: OF A DISCREPANCY IN QUANTITY OR SIZE OF CONDUIT, WIRE, EQUIPMENT, CIRCUIT BREAKERS, GROUND FAULT PROTECTION SYSTEM, ETC. (ALL MATERIAL),: DEPICTED ON THE DOCUMENTS OR SPECIFICATIONS, THE INSTALATION CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING AND INSTALLING ALL MATERIAL AND SERVICE EQUIPMENT IN, COMPLIANCE WITH ALL REGULATIONS, LAWS, ORDINANCES, OR AHJ. 4. IN THE EVENT OF CONFLICTING REGULATIONS, LAWS OR ORDINANCES, THE MOST RESTRICTIVE SHALL PREVAIL. 5. ALL ELECTRICAL- MATERIALS AND EQUIPMENT SHALL BE NEW AND LISTED BY RECOGNIZED ELECTRICAL TESTING LABORATORY. 6. AN INVERTER OR AC. MODULE IN AN INTERACTIVE SOLAR PV SYSTEM SHALL AUTOMATICALLY BE -ENERGIZE IT'S OUTPUT TO THE CONNECTED ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK UPON LOSS. OF. VOLTAGE IN THAT SYSTEM AND SHALL REMAIN IN THAT STATE UNTIL THE ELECTRICAL PRODUCTION AND DISTRIBUTION NETWORK VOLTAGE HAS BEEN RESTORED PER NEC 690.61 7. ALL SPECIFIED WIRING IS BASED ON COPPER SPECIFICATIONS. 8. THE CONTRACTOR SHALL VERIFY ALL CONTROLLING FILED DIMENSIONS BEFORE ORDERING OR FABRICANTING ANY MATERIAL. 9. SEEPROVIDED SPEC -SHEETS FOR ADDITIONAL EQUIPMENT SPECIFICATIONS. 10. PER FLORIDA STATUE 377.705 I, LUIS BARRETO WITH PE # 82006 AN ENGINEER PURSUANT TO CHAPTER 471, CERTIFIED THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. ABBREVIATIONS:.' A: AMPERES AC: ALTERNATING CURRENT AHJ: AUTHORITY HAVING JURISDICTION AWG: AMERICAN WIRE GAUGE CEC: CALIFORNIA ELECTRIC CODE CU: COPPERDC:DIRECT CURRENT DIA: DIAMETER GEC: GROUNDING ELECTRODE. CONDUCTOR IMP: MAXIMUM POWER CURRENT ISC: SHORT CIRCUIT CURRENT KW: KILO -WATTS MIN: MINIMUM NEC: NATIONAL ELECTRIC CODE NTS. NOT TO SCALE OC: OFF CENTER P: POLE- PTC: PV USA TESTING CONDITIONS PV: PHOTOVOLTAIC RR: ROOF RAFTERS TC: STANDARD TESTING CONDITIONS UL: UNDERWRITER'S LABORATORY V: VOLTS. VMP: MAXIMUM POWER VOLTAGE VOC: OPEN CIRCUIT VOLTAGE W: WATTS INDEX: CP-1 COVER PAGE WITH PROJECT LOCATION AND PROPERTY LAYOUT SP-1 SITE PLAN SD-1 STRUCTURAL DETAIL E-1 PHOTOVOLTAIC SYSTEM STRING DIAGRAM WITH ELECTRICAL SPECS. E-2 ONE -LINE ELECTRICAL DIAGRAM PLOT PLAN OF ROOF SCALE:17/256" = V-O" ,g�frf Rr� ;t PROJECT LOCATION MAP SCALE: NTS. SCALE: NTS. RECEIVED JAN 2 '3 2018 LE,I ucw c?wnxy, Permitting CHECKED BY: REVISED DATE: REVISED: 1. 2. - N/A — WA ---. . 3. N/A 4.--`--wA _ -- -- 5. — WA r INSTALLATION CONTRACTOR: ® SOLAR INDUSTRIES MAXIMO SOLAR INDUSTRIES PHONE:407-930-2030 EMAIL: FLORIDA@MAXIMOSOLAR.COM WEB: WWW.MA)aMOSOLAR.COM ENGINEER: ENG.LUIS BARRETO- .7350 FUTURES DR, #15 ORLANDO, FL, PHONE:407-446-5256 EMAIL: LBARRETO@MAXIMOSOLAR.COM I � '•L\CE�s �20% =� 'L �R I ....... . • \ \5�.,`�. 4.85 KW (UC) - 5.0 KW (AC) PV UTILITY INTERACTIVE SYSTEM WILLIAM FORRESTER. 2848 EAGLE'S NEST WAY, PORT ST. LUCIE, FL 34952 AHJ; FLORIDA POWER AND LIGHT CO PROJECT NUMBER: N10 SHEET TITLE: COVER PAGE WITH PROJECT LOCATION AND PROPERTY LAYOUT PROJECT SHEET: CP-1 t� NOTES: 1. PV EQUIPMENT SHALL BE INSTALLED IN ACCORDANCE WITH NEC 690 AND POSTED WITH APPLICABLE WARNINGS, SIGNAGE & PLAQUES PER NEC 705-10, 690-17, & 705.10 2. UTILITY HAS 24-HR UNRESTRICTED ACCESS TO ALL PHOTOVOLTAIC SYSTEM COMPONENTS LOCATED AT THE SERVICE ENTRANCE. 3. CIRCUITS SHALL BE IDENTIFIED AT POINTS OF TERMINATION, CONNECTION, AND SPLICE POINTS PER NEC 690.4(B)(2) 4. CONDUCTORS EXPOSED TO SUNLIGHT SHALL BE LISTED AS SUNLIGHT RESISTANT PER NEC 300.6(C)(1), 310.8(D) 5. CONDUCTORS EXPOSED TO WET LOCATIONS SHALL BE SUITABLE FOR USE IN WET LOCATIONS PER NEG 310.8(C) 6. WORKING CLEARANCES AROUND THE EXISTING AND NEW ELECTRICAL EQUIPMENT WILL BE MAINTAINED IN ACCORDANCE WITH NEC 110.26 7. TALL INSTALLATION PRACTICES SHALL BE IN ACCORDANCE WITH 2O17 FLORIDA BUILDING CODE (6th Edition) , 2.014 FLORIDA FIRE PREVENTION CODE AND 2014 NATIONAL ELECTRICAL CODE (NEC). - ARRAY: MODULES: (17) HYUNDAI SOLAR RG-SERIES MONO; 285 WATTS MODULE INVERTER: (1) SOLAREDGE SE5000H-US INVERTER (5,000 WATTS). ROOF: COMPOSITE SHINGLES, 4.4/12 PITCH MOUNTING METHOD: FLUSH MOUNTED AT 20° DEG RACKING: IRONRIDGE RX 100 RAIL SYSTEM ARRAY AZIMUTH: ARRAY #1: (17) MODULES AT 270° ARRAY #2: (--) MODULES AT —° ARRAY #3: (----) MODULES AT =° ARRAY #4: (---) MODULES AT —° PV SYSTEM EQUIPMENT WALL (PLAN VIEW) EQUIPMENT WALL ARRAY (ON ROOF) (ADJACENT TO UTILITY METER) -77­7 ------------ rr A C D E A (EXISTING) ALL -IN -ONE UTILITY METER AND 200A MAIN SERVICE PANEL WITH A 200 MAIN CIRCUIT BREAKER. (INTER -CONNECTION POINT AT LOAD SIDE WITH (1) 2P-30A CIRCUIT BREAKER) B C NEW (1) SOLAREDGE SE5000H-US INVERTER (5,000 WATTS) 240 VAC, NEMA TYPE 3R, UL 1741, IEEE 1547 D (NEW) CODE APPROVED CONDUIT (RUN THROUGH ATTIC, 10' BELOW:SHEATHING) rE (NEW).PV SYSTEM SOLAR DECK Photovoltaic Comhirier/Enclosure (NEMA 311, UL 1741) (AT ARRAY- UNDER MODULE) CHECKED BY: REVISED DATE: 1. N/A 2. -- WA — — 3. N/A --- — - 4.— N/A 5. + WA — INSTALLATION CONTRACTOR: Ar7'i MiAXIMO SOLAR INDUSTRIES MAXIMO SOLAR INDUSTRIES PHONE:407-930-2030 EMAIL: FLORIDA@MAXIMOSOLAR.COM WEB: WWW.MAAMOSOLAR.COM ENGINEER: l ENG. LOIS BARRETO .7350 FUTURES DR, #15 ORLANDO, FL PHONE:407-446-5256 EMAIL: LBARRETO@MAXIMOSOLAR.COM \CE/VS ' ^ o2006 . STA7`E OF �01 '..40117P PV PROJECT INFORMATION: 4.85 KW (DC) - 5.0 KW (AC) . PV UTILITY INTERACTIVE SYSTEM WILLIAM FORRESTER 2848 EAGLE'S NEST WAY, PORT ST. LUCIE; FL 34952 AHJ: FLORIDA POWER AND LIGHT CO PROJECT NUMBER: F410 A SHEET TITLE: SITE PLAN. BACKS PROJECTSHEET: ;ALE: Custom SP-1 HARDWARE DETAIL SCALE: NTS. IRONRIDGE FLASHFOOT2 (FRONT VIEW) IRONMDGE END CLAMP ' I I I I - �-IRONRIDGE xR 1 W RAIL IRONRIDGE _ FLASHF0072 IRONRIDGE FLASHF00T2 (3D VIEW) . - O a HARDWARE DETAIL CLAMPS SCALE: NTS. DETAIL, END CLAMP FRONT IRONRIDGE STOPPER SLEEVE DETAIL, MID CLAMP FRONT :ONRIDGE UNIVERSAL FASTENING INUECT PV M- FRAME � IRONRIDGE RAIL I IRONRIDGE XR 100 RAIL <, IRONRIDGE XR 100 RAIL I SOLAR MODULE: MECHANICAL DATA: HYUNDAI SOLAR RG-SERIES MONO, 285 WATTS MODULE MODULE SPECIFICATIONS: MODULE SQUARE FOOTAGE: MODULE WEIGHT PER. SQUARE FOOT. SOLAR ARRAY: MECHANICAL DATA MODULES MODULE DEAD LOAD: ARRAY SQ.FT: ARRAY DEAD LOAD (RACKING INCLUDED): DEAD LOAD PER ATTACHMENT POINT: ARRAY DEAD LOAD WILL NOT EXCEED: ARRAY DEAD LOAD: CONNECTOR TYPE:. ATTACHMENT POINTS: NOTES 64.57" x 39.29" x 1.38', 41.20 LBS 17.61 SQ.FT 2.33 LBS (17) MODULES 674.90 LBS 306.85 SOFT 790.84 LBS 26.0 LBS 4.0 LB/SQ.FT 2.52 LB/SQ.FT 5116" X 3.5" S.S. LAG SCREW (2.5" MIN. EMBEDMENT) (34) TOTAL 1. VERIFY ALL MEASUREMENTS AND CHALK INSTALLATION AREA PRIOR TO DRILLING PILOT HOLES. 2. DRILL 3/16' PILOT HOLE PRIOR TO SECURING LAG BOLT 3. LAG BOLT SHALL BE LOCATED IN THE MIDDLE THIRD OF THE STRUCTURAL MEMBER 4. SECURE LAG BOLTS FLUSH TO STRUCTURAL MEMBERS FOLLOWING MANUFACTURES SPECIFIED TORQUE STRENGTHS. 5. SEAL CONNECTION POINTS WITH ROOF GRADE GEOCEL SEALANT. 6. FOLLOW MANUFACTURE'S RECOMMENDATIONS REGARDING RAIL SPLICE POINTS FOR THERMAL EXPANSION CONSIDERATION. MODULE DETAIL SCALE: NTS. (D)1.38°� (VV) 39.29'�' ELEVATION DETAIL SCALE: NTS. QUICKMOUNT PV E-MOUNT 5/16" X 3.5" S.S. LAG SCREW 2.5" MIN. EMBEDMENT- SEAL PENETRATION WITH GEOCEL BASED ROOF SEALANT IRONRIDGE END / MID -CLAMP COMPOSITE SHINGLES ROOF 9 RACKING MOUNT SCALE: Custom CHECKED BY: REVISED DATE: REVISED: — -- 1. N/A- 2. - — NIA 3. N/A 4. — N/A -- — 5 — N/A -- -- (INSTALLATION CONTRACTOR: 4 A .MAXIMO . SpLAR INDUSTRIES MAXIMO SOLAR INDUSTRIES PHONE:407-930-2030 ENTAIL: FLORIDA@MA)OMOSOLAR.COM WEB: WWW.MA)aMOSOLAR.COM ENGINEER: ENG.LUIS BARRETO 7350 FUTURES DR, #15 ORLANDO, FL. PHONE:407446-5256 ENTAIL: LBARRETO@MAXIMOSOLAR.COM BA -�CEN`sc No 8200S = STq E i per` L.O p OTC •\ <Q. ' I �'r `✓ �'J 1 1 4.85 KW (DC) - 5.0 KW (AC) PV UTILITY INTERACTIVE SYSTEM WILLIAM FORRESTER 2848 EAGLE'S NEST WAY, PORT ST. LUCIE, FL 34952 AHJ: FLORIDA POWER AND LIGHT CO PROJECT NUMBER: F410 SHEET TITLE: STRUCTURAL DETAILS PROJECT SHEET: S-1 SOLAR MODULE: ELECTRICAL DATA HYUNDAI SOLAR RG-SERIES MONO, 285 WATTS MODULE SPECIFICATIONS AT STC MAXIMUM POWER VOLTAGE (Vmp): 31.80V MAXIMUM POWER CURRENT (Imp): 8.90A OPEN CIRCUIT VOLTAGE (Vac): 38.70V SHORT CIRCUIT CURRENT (Isc): 9.50A SERIES FUSE RATING: 15A Voc TEMPERATURE COEFFICIENT: -0.300A/C° WEIGHT: 41.20 LBS DIMENSION: 39.29" x 64.57" x 1.38" STC= 25°0,1000W/Mz,1.5 AIR MASS SOLAR INVERTER: ELECTRICAL DATA SIZE: MFR: - MODEL CERTIFICATION: MAX INPUT VOLTAGE: NOMINAL DC INPUT VOLTAGE: MAX INPUT CURRENT (Imp): MAX INPUT CURRENT (Isc): MAX OUTPUT CURRENT (Imax): MAX CONTINUOUS POWER: CEC WEIGHTED EFFICIENCY: WEIGHT: DIMENSION: PROTECTION RATING: 5,000 WATTS (AC) SOLAREDGE HD -WAVE SE5000H-US UL 1741, IEEE 1547 480 VDC 380 VDC 13.5 ADC @ 240 45 ADC 21A @ 240V 5,000 W 99% 25.1 LBS 450mm x 370mm x 174mm NEMA 3R NOTES 1. ALL EQUIPMENT SHALL BE INSTALLED AND LABELED IN ACCORDANCE WITH THE NEC AND ALL APPLICABLE REQUIREMENTS OF THE SERVING ELECTRIC UTILITY COMPANY AND OF THE LOCAL AUTHORITY HAVING JURISDICTION. 2. BI-DIRECTIONAL UTILITY METER INSTALLED BY UTILITY COMPANY (AS REQUIRED). 3. LABEL BREAKER 'PHOTOVOLTAIC ELECTRIC POWER SOURCE PER NEC 705.10, AND "BREAKERS ARE SUITABLE FOR BACKFEED" PER NEC 705.12 (D)(5). LABEL WITH THE MAXIMUM AC OUTPUT OPERATING CURRENT AND THE OPERATING VOLTAGE. 4. LABEL "PHOTOVOLTAIC SYSTEM UTILITY DISCONNECT SWITCH". SWITCH COVER TO BE LOCKED AT ALLTIMES. SWITCH TO BE VISUAL OPEN AND ACCESSIBLE PER UTILITY REQUIREMENTS AND CONFORM TO NEC 705.22. 5. LABEL "PHOTOVOLTAIC ARRAY DC DISCONNECT DEVICE #/6" PER NEC 690.14 (C)(2). LABEL WITH OPERATING CURRENT, - OPERATING VOLTAGE, MAXIMUM SYSTEM VOLTAGE, AND SHORT CIRCUIT CURRENT PER NEC 690.53. SWITCH TO BE LOCKED PER NEC 690.7 (D). 6. LABEL "PHOTOVOLTAIC SYSTEM METER". METER ENCLOSURE AND SOCKET PROVIDED AND INSTALLED BY CUSTOMER. METER PROVIDED BY CUSTOMER. 7. PROVIDE WARNING SIGN PER NEC 690.17 READING "WARNING -ELECTRICAL SHOCK HAZARD -DO NOT TOUCH TERMINALS -TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED IN THE OFF POSITION." 8. LABELWARNING INVERTER OUTPUT CONNECTION. DO NOT RELOCATE THIS OVERCURRENT DEVICE" AND LOCATE BREAKER AT OPPOSITE END OF THE BUS FROM MAIN BREAKER LOCATION PER NEC 705.12(D)(7). 9. LABEL "WARNING, ELECTRIC SHOCK HAZARD. THE DC CONDUCTORS OF THIS PHOTOVOLTAIC SYSTEM ARE UNGROUNDED AND MAY BE ENERGIZED." PER NEC 690.35(F) 10. LABELWARNING, ELECTRICAL SHOCK HAZARD IF GROUND FAULT IS INDICATED, NORMALLY GROUNDED CONDUCTORS MAY BE UNGROUNDED AND ENERGIZED." PER NEC 690.5 (C) 11. ALL CONDUITS SHALL BE USED WITHIN BUILDING PER NEC 690.13(E). 10. PER FLORIDA STATUE 377.7051. LUIS BARRETO WITH PE # 82006 AN ENGINEER PURSUANT TO CHAPTER 471, CERTIFIED THAT THE PV ELECTRICAL SYSTEM AND ELECTRICAL COMPONENTS ARE DESIGNED AND APPROVED USING THE STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. 11. LABEL "DEDICATED PHOTOVOLTAIC SYSTEM COMBINER PANEL" AND "DO NOT ADD: LOADS TO THIS PANEL". 12. ALL INSTALLATION PRACTICES SHALL BE IN ACCORDANCE WITH: 12.1. 2014 NATIONAL ELECTRICAL CODE 12.2. 2017 FLORIDA BUILDING CODE (SIXTH EDITION) 12.3.. 2014 FLORIDA FIRE PREVENTION CODE 12.4. 2014 FLORIDA PLUMBING CODE 12.5. 2014 FLORIDA MECHANICAL CODE 12.6. 2014 FLORIDA FUEL GAS CODE 12.7. 2014 FLORIDA EXISTING BUILDING CODE 12.8. 2014 FLORIDA ENERGY CONSERVATION CODE 12.9. ANY LOCAL AMENDMENTS PV SYSTEM: SIZE AND EQUIPMENTS 4.85 KW (DC) - 5.0 KW (AC) (17) HYUNDAI SOLAR RG-SERIES MONO, 285 WATTS MODULE (1) SOLAREDGE SE5000H-US INVERTER (5,000 WATTS) PV SYSTEM: STRINGS CIRCUITS DISTRIBUTION: STRING #1 17 HYUNDAI SOLAR RG-SERIES MONO, 285 WATTS MODULE PV SYSTEM: BRANCH CIRCUITS DEMONSTRATION CHECKED BY: REVISED DATE: REVISED: 1. N/A 2. N/A -- 4. - N/A ----- 5. N/A INSTALLATION CONTRACTOR: MAXIMO:, SOLAR INOUSTRIES MAXIMO SOLAR INDUSTRIES PHONE:407-93D-2030 EMAIL: FLORIDA@MAXIMOSOLAR.COM WEB: WWW.MA)CMOSOLAR.COM ENGINEER: ENG. LUIS BARRETO 7350 FUTURES DR, #15 ORLANDO, FL. PHONE:407-446-5256 EMAIL: LAARRETO@MAXIMOSOLAR.COM (------till "ITIFrr��ry ---- c�S.�TO I� L No.82006 y l STATE OF i f 1.Jr-� PV PROJECT INFORMATION: 4.85.KW (DC) - 5.0 KW (AC) PV UTILITY INTERACTIVE SYSTEM WILLIAM FORRESTER 2848 EAGLE'S NEST WAY, PORT ST. LUCIE, FL 34952 AHJ: FLORIDA POWER AND LIGHT CO PROJECT NUMBER: F410 SHEET TITLE: SYSTEM STRING DIAGRAM WITH ELECTRICAL SPECS. PROJECT SHEET: E-1 WIRE STRING #1- PV SOURCE CIRCUIT: V V v V (17)HYUNDAI SOLAR RG-SERIES MONO 285 WATTS MODULE Voc MAX 38.70 VDC + �ff + �ff � � � � � � Isc = 9.50 AMPS SOLAREDGE SINGLE PHASE STOREDGE INVERTER-SE5000H-US as 0 0 L0000 240 VAC (10 FT RUN) (2) #6 AWG THWN-2 CU (L1, L2) (1) #6 AWG THWN-2 CU (NEUTRAL) (1) #6 AWG THWN-2 CU (GROUND) 1' CODE APPROVED CONDUIT RUN (RUN ALONG EQUIPMENT WALL) SAFETY LABELING WARNING 0 WARNING m PV SYSTEM AC DISCONNECT Q WARNING Q PHOTOVOLTAIC SYSTEM • D PHOTOVOLTAIC ELECTRIC SHOCK HAZARD. ELECTRIC SHOCK HAZARD. RATED AC OUTPUT CURRENT:30AMPS INVERTER OUTPUT CONNECTION: SHUTDOWN�� DO NOT IF A GROUND FAULT IS INDICATED. NORMAL OPERATION VOLTAGE 120/240 VOLTS DO NOT RELOCATE THIS OVERCURRENT DEVICE WITH RAPID • • TERMINALS ON BOTH LINE AND NORMALLY GROUNDED CONDUCTORS 690.54 690.56(C) fi90.31(G)(3) LOAD SIDES MAY BE ENERGIZED MAY BE UNDERGROUND AND ENERGIZED 70512(D)(2)(3)(b) (Required at location roved h [Not require R panelboard Is rated not less than sum of ampere lR approved y �1 (Marked on jimdion/ccmbiner bores and conduit every 101 IN THE OPEN POSITION. 690.5(C) ) ratings of all overcunent devices supplying Iq 690.17(E) (Normally already present on listed invaders) Nit --------------� 90906[afb; (Only required for underground systems] [Not requite it panelboard is rated not fens Dun sum of ampere ratings of 91 overnment devices supplying itj INTER -CONNECTION POINT (LOAD SIDE) EXCLUSIVE 2PS0A CB TO PV Voc MAXIMUM CALCULATION: 40.1 (1 + (1 °C - 251C)(-.30%/C°) = Voc MAX 40.1 (1.07) = 42.91 AT 1 °C (ASHRAE) TEMPERATURE MINIMUM: -40'C TEMPERATURE MAXIMUM: 65 °C •ASHRAE CONDUCTOR COLORING: (DC) POSITIVE: BLACK NEGATIVE: RED GROUND: GREEN/BARE CONDUCTOR COLORING: (AC) L1: BLACK L2: RED N: WHITE GROUND: GREEN NOTE: ONLY CONDUCTORS LARGER THAN #6 ARE ALLOWED TO RE -IDENTIFICATION. CONDUCTORS #6 OR SMALLER WIRE SIZE SHALL ABIDE BY CHART ABOVE. (EXISTING) 120/240 VAC,1 (EXISTING) MAIN SERVICE PANEL UTIUTYMETER L O (DE -RATED) / 200A l L MAIN BREAKER J_j G (EXISTING) SYSTEM GROUND: LIFER 120/240 VAC, 1(P UTILITY GRID VOLTAGE DROP CALCULATION V drop% = VOLTAGE DROP (volts) (%) I op= OPERATING CURRENT (amps) L = LENGTH OF CIRCUIT (0) V op = OPERATING VOLTAGE (volts) Iopx2xL _ x 1000 fVkftk8 Vop x100 (1)14 BRANCH CIRCUIT (PORTRAIT) V-DROP PER ENPHASE V-DROP GUIDE = 0,57% J-BOX TO PVSUBSYSTEM LOAD CENTER V drop% = 20Ax2x65' x 12 1000 fVkft 240V x 100 =1.3% PV SUB -SYSTEM LOAD CENTER TO INTERCONNECTION 20Ax2x10' x 12 V drop% = 1000 fVkft 240V x 100 = 0.2% PV SYSTEM WORST CASE V-DROP (LONGEST SYSTEM RUNS) 1.5% CHECKED BY: REVISED DATE: REVISED: I • 1 WA 2. WA3. NIA N/A ---- -- 5. WA r INSTALLATION CONTRACTOR: MAXIMO SDLAR INDUSTRIES MAXIMO SOLAR INDUSTRIES PHONE:407-930-2030 EMAIL: FLORIDA@MAXIMOSOLAR.COM WEB: WWW.MAXIMOSOLAR.COM i ENGINEER: ENG.LUIS BARRETO 7350 FUTURES DR, #15 ORLANDO, FL PHONE: 407-446-5256 EMAIL: LBARRETO@MAXIMOSOLAR,COM — -- — ——++—,11nu luenyyy — — — — — I " o I �� \�J �\C�'- I No 82006 _ srarE of _ PV PROJECT INFORMATION: 4.1J0 KW ILA.;) -b.0 KW (AL;) PV UTILITY INTERACTIVE SYSTEM WILLIAM FORRESTER 2848 EAGLE'S NEST WAY, PORT ST. LUCIE; FL 34952 AHJ: FLORIDA POWER AND LIGHT CO PROJECT NUMBER: F410 SHEET TITLE: ONE -LINE ELECTRICAL DIAGRAM PROJECT SHEET: E-2