Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOF1/3/2018 Florida. Building Code Online •usPnesOsBO CANNA ' f� ► 1 1 . • . 1 �U �y BCIS Home I Log In I user Registration I Hot Topics I Submit Su c'e,tat3'&yFva N P�ublicatlon� Map' I Links I •Search d.bor Product Approval Eckba USER: Public User Product Approval Menu > Product or Application Search > Application List > Application Detail FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence FL11651-R3 Revision 2017 Approved O RECEIVED JAN 2 3 2018 ST, Lucle County, Permitting Gulf Coast Supply & Manufacturing, LLC. 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352)498-0778 flvalidation@yahoo.com Ray Bowen 7 flvalidation@yahoo m=co'vo7 0P David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Roofing Metal Roofing Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Daniel S. Kuhn PE-75510 Keystone Certifications, Inc. 04/12/2024 Locke Bowden ❑d Validation Checklist - Hardcopy Received FL11651 R3 COI Cert of Independence 2017-10-09.odf Referenced Standard and Year (of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL1897 2012 https://floridabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDgsQFc5Kp/p2frrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnA°/p3d%3d 1/5 1/3/2018 Florida Building Code Online _ UL 580 �,� 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page [— 10 FL # I Model, Number or Name 11651.1 0.032" Aluminum 5V Crimp Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 Limits of Use Approved for use in. HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @ 12" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.2 1 0.032" Aluminum Gulf Lok Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.3 1 1" 24ga. Gulf Snap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--131.OPS Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.4 1 1" 24ga. VersaLoc Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.5 1 1" VersaLoc .032" Aluminum Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A 0 to Page I / 2 0 40 Description Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail- sioned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 1 R3 0325vCrimo 15- 32Plywood NonHVHZ-sioned.odf Created by Independent Third Party: Yes Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 2 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 2 R3 032GulfLok 16 15- 32Plvwood NonHVHZ-sioned.odf Created by Independent Third Party: Yes 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 3 R3 1 24GuifSnao 17 15- 32Plywood HVHZ-sioned.pdf Created by Independent Third Party: Yes 1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.5 15- 32Plywood HVHZ-signed.pdf Created by Independent Third Party: Yes 1" Versal-oc min .032" Aluminum over 15/32" Plywood Installation Instructions FL11651_ R3 II FL11651 5 R3 Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 hfps://fioridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnA%3d%3d 2/6 1/3/2018 Design Pressure: +N/A/ -Si', SF Other: -63.3 psf @ 24" o.c, ciip spacing. -101.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.6 1 1.5" 24ga. Gulf Snap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers detals. For use in HVHZ Zones. 11651.7 1 1.5" 24ga. VersaLoc Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.8 12" 24ga. MegaLoc Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Florida Building Code Online Created by Indepe, Third Parry: Yes Evaluation Reports FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc SR 16 15-32Plywood HVHZ-signed.pdf Created by Independent Third Party: Yes 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail- sioned.Ddf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnaD 16 15- 32Plvwood HVHZ-signed.pdf Created by Independent Third Party: Yes 1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15- 32Plvwood HVHZ-signed.pdf Created by Independent Third Party: Yes Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail- signed.Ddf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 15- 32Plvwood NonHVHZ-signed.odf Created by Independent Third Party: Yes 111651.9 124 Ga. Gulf Lok I Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-96.7PSF Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8" fastener spacing. -161 psf @ 5-1/8" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 9 R3 24GulfLok 16 15- 32Plvwood NonHVHZ-signed.Ddf Created by Independent Third Party: Yes 11651.10 124 Ga. Gulf Seam I Min ns over 1 2if tam 16" Wide ide Roof Panel over 1x4 Wood Purlin Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.SPSF Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail- signed.Ddf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 IS- 32Plvwood NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.11 24 Ga. Gulf Seam I oMin 24 Ga. I ver 15/32" GulfPlywood Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c, clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15- 32Plvwood NonHVHZ-signed.pdf Created by Independent Third Party: Yes hftps:llfloridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnA%3d%3d 3/5 1/3/2018 �� Florida Building Code Online 11651.12 26� ;iV Crimp Min 26 Ga. 5V Crin W Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail - signed.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ Evaluation Reports 6" o.c. fastener spacing. Install per manufacturers details. For FL11651 R3 AE FL11651 12 R3 265vCrimp 15- use in HVHZ Zones. 32Plywood HVHZ-sioned.pdf Created by Independent Third Party: Yes 11651.13 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail - signed.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-131.PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ Evaluation Reports 16" o.c. fastener pattern. Install per manufacturers details. FL11651 R3 AE FL11651 13 R3 265vCrimp 15- 32Plywood NonHVHZ-sioned.pdf Not for use in HVHZ Zones, Created by Independent Third Party: Yes 11651.14 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail - sioned.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-156.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ Evaluation Reports 6" o.c. fastener spacing. Install per manufacturers details. For FL11651 R3 AE FL11651 14 R3 265vCrimo 1x4 15- 32Plvwood NonHVHZ-sioned.pdf use in HVHZ Zones. Created by Independent Third Party: Yes 11651.15 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail - signed.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-161.OPSF Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf Evaluation Reports @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing. FL11651 R3 AE FL11651 15 R3 26GuifLok 16 15- 32Plvwood HVHZ-sioned.pdf Install per manufacturers details. For use in HVHZ Zones. Created by Independent Third Party: Yes 11651.16 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail - sioned.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-63.5PSF Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf Evaluation Reports @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener FL11651 R3 AE FL11651 16 R3 26GuifLok 16 15- 32Plywood NonHVHZ-signed.ndf spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.17 26 Ga. GulfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail - sioned.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf @ Evaluation Reports 12" o.c. fastener pattern. Install per manufacturer details. Not FL11651 R3 AE FL11651 17 R3 26GulfPBR 15- for use in HVHZ 32Plvwood NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.18 126 Ga. GulfPBR I Min 26 Plywood GulfPBR Roof Panel over ix4 Wood Purlins over Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf @ 12" fastener spacing. Install per manufacturer's details. For use in HVHZ Zones Installation Instructions FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 18 R3 26GulfPBR 1x4 15- https://floridabuilding.org/prlpr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d 4/5 1/3/2018 Florida Building Code Online 32Plvwood HVHZ-5i J.pdf Created by Indepe..._i,Third Party: Yes 11651.19 26 Ga. GulfPBR Min 26 Ga. GulfPBR over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail - signed.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @ Evaluation Reports 12" o.c. fastener spacing. Install per manufacturer's details. FL11651 R3 AE FL11651 19 R3 26GulfPBR 15- For use in HVHZ Zones. 32Plvwood HVHZ-signed.pdf Created by Independent Third Party: Yes 11651.20 26 Ga. GUIfPBR Min 26 Ga. GUIfPBR over lx4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail - sioned.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 20 R3 26GulfPBR lx4 15- 32Plvwood NonHVHZ-sioned.odf use in HVHZ Zones Created by Independent Third Party: Yes Go to Page " 0 Back Next (110 0 Pagel/ 20 0 Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an WEED employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Appp-roovpa�l Accepts: ® ® roLi eCheck M Credit Card Safe https://floddabuilding.org/pr/pr_app_,Otl.aspx?param=wGE\rXOwtDgsQFc5K%2ffrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfinrnA°/gad%3d 5/5 Aom"o x I IrW010'\di® Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC. 26 Ga. SV Crimp Roof Panel over 15132" Plywood Florida Product Approval #11651.13 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 ��•P x11EL S, k'�,,� Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# 11651.13 R3 - OCTOBER 5, 2017 V. * • No. 7551.9 :��• STATE OF - OR IV ''�s; 0NA L ENS0/05/�0� Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/3z" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/8" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures: FL# 11651.13 R3 e OCTOBER 5, 2017 Table "A" Maximum Total Uplift Design Pressure 94.25 psf 131.0 psf Fastener Pattern 12"-12" 9.5"-2"-9.5" Fastener Pattern Spacing 16" O.C. 16" O.C. Design Pressure includes a Safety Factor = 2.0. Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0053T 05 & 117-0331 T-08 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL# 11651.13 R3 • OCTOBER 5, 2017 /\ z2'a i` ■ Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.13 R3 • OCTOBER 5, 2017 ENGINEER LOAD TABLE: 26 Ga. 5VCrimp Roof Panel over 15/32" Plywood Buildings having a Roof Mean Heights 20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof; Wind Speeds 120- 180mph, Exposure C, Risk Category II, Enclosed Building, based on Florida Building Code 2017. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. 1/4' Penetration) (MIN.15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #9-15X1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 ZONE 2 #9-15X1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 ZONE 3 #9-15X1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 2 16" TYPE 2 1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. 2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN. A" PENETRATION. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN. 15h2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. wD Dnnc LVIYC L ZONE 3 r ----------------- RIDGE ZONE ----------- - - - - - - Note: Dimension (a) is defined as 10% of the minimum width of the building or 1:1fa 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be less than either 4% of the minimum width of the building or 3 feet. ZONE 2 GABLE ROOF —J—------------------1a I I I I RIDGE ----- --------------� �a — — — — — — — — — a ZONE 1 ---------------------- "ZONE 3 `EAVF FL# 11651.13 R3 9 OCTOBER 5, 2017 TYPE 1 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer At Panel Lap TYPE 2 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer