Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGILE CO,:,�' Y V. ,4 By �. U., S# Lucie County I BCIS Nome I Log In Ur Registration ( I Hot Topics Submit Surcharge Stats & Facts i Publications I FBC Staff i BCIS Site Map Florida 9 Product�Approval P _ � rUSER: Public User 3 Application List > Application Detail 1 THESE PLANS A'ND ALL PROPOSED WORK Product Approval Menu > Product or AppliCation Searrh > I ARE SSUQJECT TO ANY CORRECTIONS > FL # . Application Type FL17022-R7 Revision � � REQUIRED BY FIELD INSPECTORS THAT Code Version 2017 �; NECESSARY Vl fit -,MAY BE, NECESSARY IN 022E d TO.;:r'':, Application Status Approved C.OM LVMTiHA L' 4PPLICA�, CODES." Comments 08/18/2017v. date reapply 08/21/17 Archived ❑ ' Product Manufacturer i Extreme Metal Fabricators, LLC CONCEALED FASTENERS OR ATTACHMENTS Drive Address/Phone/Email 2160 SW Poma Palm City, 341 (772)872-8034i ARE THE RESPONSIBILITY OF THE flvalidation@yalhoo.com CONTRACTOR OF RECORD Richard McKuhen Authorized Signature fivalidation@ya hoo.com Technical Representative Richard McKuhen 2160 SW Poma Drive / ! O 0 Address/Phone/Email Palm City, FL 34990 (772)872-8034 ST LUCIE COUNTY richard@er�fab.net BUILDING DIVISION REVIEWED 4' FOR COM Quality Assurance Representative REVIEWED BY Address/Phone/Email DATE ! PLANS AND PER IT Category Roofing/ MUST BE KEPT ON JOB OR Subcategory Metal Roofing NO INSPECTION WILL BE MADE EvaluaI tion Report from a Florida Registered Architect or a Licensed - Compliance Method Florida Professional Engineer L Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed 1 LOCKE BOWDEN the Evaluation Report Florida License PE149704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. E Validation Checklist - Hardcopy Received Certificate of Independence �FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odF Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Compliant with Florida Building Code 2017 (6th ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. Yield strength: 50 ksi min.; Attached to m Deck w/ min. 0.42 specific gravity with scr Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Palm City, FL 34990 W7.4.2 .15/32" plywood or Wood us. 24" Coverage Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16:' min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1i 1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Slope: Shall be in compliance with FBC Sec. rt 1507.1.1 Fastener attachment specifications above install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o�c._ 16".o.c.. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" ox. 12" o.c. 12" O.C. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report 03893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/19/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standaid UL 1897-1*Design pressure margin of safety 2:1 irrrrr . C D. rJOv Locke Bowden, P.E. does not have, not will acquire a financialjint iq a Jfcc? W; m?Vacturing or distributing products under this evaluation. I ' Locke Bowden, P.E. is not owned, operated, or controlled by pay coApar(Vpmb63WtureP, or distributing products under this report. IS J FL17022.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed. 2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm'values are outside this.report. 6. Support framing in compliance w/FBC 2017 61' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. 761" or greater Plywood, or Wood plank Nm I C4(opy 14" 12" 31rr I {}rPMNAL STR#AiYr3FtS I Panel Profile Nominal 12" Nominal 12" o.c. O.C. Fasten 9 —xi -1 /2" Min. or #10 X 1-1/2" Min. per -fable "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or -Wood plank