Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFFILE COPY,---.,, [ sGANNED BY �#�s s�`.�5 � •. ��6r ���-3f �� �i a SLucie C00Y*Hi t timauoifakf2 i W-o !CIS Home Log In User Registration It HotTopics submitSurrharge � Stats&Facts 1 Publications I FBCStaff BCISSiteMap I Unks 1� Search dR0?Gfr7 r P Product Approval USER: public User Product Approval Menu > Product or Application Search > FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative ! Address/Phone/Email I i r Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence list > Application Detail RECEIVED Revision• 2017 BAN 2 3 2018 Approved ST. Lucie County, Permitting 08/18/2017v.date reapply 08/21/17 THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS Extreme Metal Fabricators, LLC REQUIRED BY FIELD INSPECTORS THAT 2160 SW Poma Drive Palm City, FL 34990 r vw`. MAY BE NECESSARY IN ORDER TO � �:, (772) 872-8034 �a CO fivalidation@yahoo.com ®i��9�°�. �h L 1' XIluAn �/UES°�' Richard McKuhen fivalidation@yahoo.com Richard McKuhen . mw � % 2160 SW Poma Drive ST, LUCIE COUNTY Palm City, FL 34990 BUILDING DIVISION (772) 872-8034 REVIEWED rchard@emfab.net FOR COMPL09E REVIEWED BY DATE 02-02 /Q e PLANS AND PER MUST BE KEPT ON OB OR Roofjng NO INSPECTION WIL BE MADE Met' .:^"• al• Roofin. gc Evaluation Report from a Florida Registered Architect or a licensed Florida Professional Engineer L Evaluation Report - Hardcopy Received LOCKE BOWDEN PE-49704 Keystone Certifications, Inc. 04/22/2024 Zachary R. Priest, P.E. El Validation Checklist - Hardcopy Received FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.odf Referenced Standard and Year (of Standard) Standard TAS 125 UL 1897 UL 580 Equivalence of Product Standards Certified By Sections from the Code Year 2003 2012 2006 Compliant with Florida Building Code Compliant with Florida Product Appr( Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Yield strength: 50 ksi min.; Deck w/ min. 0.42 specific I Rib Height 3/8" Corrosion Resistant Compliant: FBC Fastener 1(Method 1 Attachment):� 3/16" min. thru deck or 5/8" embec requirements) ' Palm City, FL 34990 7 (61 ed.) Rule # 61G20-3 I FBC Sec.1507.4.2 :hed to min.15/32" plywood or Wood y with screws. 24" Coverage Sec.1S07.4.3 #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate Iment into wood plank. (*or sufficient length to meet Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlavment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A Allowable Loads METHOD 1 METHOD 2 METHOD 3 METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING 16" o.c. 16" o.c. 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) 12" o.c. 12" o.c. 12" o.c. 12" o.c. FASTENER SIZE 1 #9 #10 #10 #10 Reference Data: ARCHITECT6RAL TESTING, INC. TST ID#: 1527 UL 580-06 & 1897-041 Test Report DM893.01-450-18 05/02/14 Test Report F3366.01-450-18 12/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is, equivalent to test standard UL 1897-1fi *Design pressure margin of safety 2.1 Locke Bowden, P.E. does not have, not will acquire a financial int Pq a cq pq�►m Ow . under this evaluation. • Locke Bowden, P.E. is not owned, operated, or controlled by a fy colApar1llpmbi1a 4;tures, or di report. '/• `"1 ANAL ��• +�' or distributing products products under this r i ._1% v\ FL17O22.1 5V Crimp (26GA S Limitations: 1. Underlayment to be compliance with current Florida Buildil 2. Minimum slope to be compliant with Florida Building Code 3. Products are compliant for State of Florida product approv 4. Engineering analysis for "project specific approval by local 5. Fire classification is not part of this acceptance. Shear dial 6. Support framing in compliance w/FBC 2017 6th ed., Chapt Structural Loading. 7. This report does not imply warranty, installation, recomme 1), 24" Wide Roof Panel - Details Code (FBC)2017 6th ed. )17 61h ed., and per with Manufacturer's installation -reference. per Rule 61G20-3. Compliance Method: 1-D ithorities w/jurisdiction is allowed by other registered engineers. ragm values are outside this report. 22 for Steel, Chapter 23 for Wood and Chapter 16 for product use outside of this report. 15132" or greater Plywood, or Wood plank FILE COPY _247- 3t8 {ir�'I'iCYB1.ALS'YRIFTtL1�S Nominal 12" O.C. Panel Profile Nominal 12" O.C. Fasten 9 -xi -1 /2" Min. or #10 X 1-1/2" Min. per 'Table "A' Hex Washer Head Screw Spaced 12 o.c. across the Panel Width Panel Refer to Table "A" for Spacing Along Panel Overlap Length Deck-15/32" or greater Plywood, or -Wood plank