Press Alt + R to read the document text or Alt + P to download or print.
This document contains no pages.
HomeMy WebLinkAboutEVALUATION REPORT-1=1 -n4u11UJ d1J11 I 4+ D
juaw:pedaa 5u1P!Waad
IN
610Z 6 0 Ndf
(13AI3331i
��TRINITYJ ERD
TABLE lE: WOOD DEGKS-NEW CINSTRUOT,110,N I RER
EAR= FF OR
SYSTEM TYPED: PRELIMINARILY ATTACHED IN5U-W. IO , MECHANICALLY
ATTACHED BASE SHEET, BONDED ROOF COVER
0Systeres
Insulation Layers)
Base Sheet
Roof Cover (Note 15)
MDP
No.
Deck (Note 1)
Type
Attach
Type Fasten
Attach
Base Ply
Cap Ply
(Psf)
JASP�KAMAF
ueo oR Taea-MPueo
BW PLv:
Elastobase, Elastobase P,
OMG Flat Bottom Plates (square) with
Min. 19/32-
One or more
Prelim.
Polyglass G2 Base, CertainTeed
Roofgrip #14, Dekfast Hex (aka, Dekfast PLT-
12-inch o.c. in 4-inch lap and 12-
(Optional) BP -AA,
SBS-AA, SBS-
W-56
inch plywood
layers, any
Attached
Glasbase, Firestone MB Base,
with Dekfast or Trufast 3"
inch o.c. in two (2), equally spaced,
SBS-AA, SBS-TA or
TA, APP-TA
-52.5
combination
JM Perma-Ply 28, Tamko Glass
wit#14h
Metal Insulation Plate with Trufast HD
Metal In
staggered center rows
APP-TA
Base or GAFGLAS #75
Min. 19/32-
One or more
Prelim.
OMG Flat Bottom Plates (square) with
12-inch o.c. in 4-inch lap and 12-
(Optional) BP -AA,
SBS-AA, SBS-
W-57
inch plywood
layers, any
Attached
Elastobase or Elastobase P
Roofgrip #12
inch o.c. in two (2), equally spaced,
SBS-AA, SBS-TA or
TA, APP-TA
-60.0
combination
staggered center rows
APP-TA
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Min. 15/32-
One or more
Prelim.
Polyglass G2 Base, Elastobase,
Dekfast #14, OMG 3" Round Metal Plate
10-inch o.c. in 4-inch lap and 10-
(Optional) BP -AA,
SBS-AA, SBS-
W-58
inch plywood
layers, any
Attached
Elastobase P
with OMG HD, OMG Flat Bottom Plate
inch o.c. in three (3), equally
SBS-AA, SBS-TA or
TA, APP-TA
-75.0
combination
(Accutrac) with Roofgrip #14 or Trufast 3"
spaced, staggered center rows
APP-TA
Metal Insulation Plate with Trufast HD.
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Min. 15/32-
One or more
Prelim.
Dekfast #14, OMG 3" Round Metal Plate
10-inch o.c. in 4-inch lap and 10-
W 59
inch plywood
layers, any
Attached
Polyglass APP Base
with OMG HD, OMG Flat Bottom Plate
inch o.c. in three (3), equally
(Optional) APP-TA
APP-TA
-75.0
combination
(Accutrac) with Roofgrip #14 or Trufast 3"
spaced, staggered center rows
Metal Insulation Plate with Trufast HD.
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Min. 15/32-
—One or more
-_
Prelim.
Polyglass G2 Base, Elastobase,
Dekfast #14, OMG 3" Round Metal Plate
9-inch o.c. in 4-inch lap and 9-inch
(Optional) BP -AA,
SBS-AA, SBS-
W-60
inch plywood
layers, any
Attached
Elastobase P
with OMG HD, OMG Flat Bottom Plate
o.c. in four (4), equally spaced,
SBS-AA, SBS-TA or
TA, APP-TA
-90.0
combination
(Accutrac) with Roofgrip #14 or Trufast 3"
staggered center rows
APP-TA
Metal Insulation Plate with-Trufast HD.
Dekfast Hex (aka, Dekfast PLT-H-2-7/8) with
Min. 15/32-
One or more
Prelim.
Dekfast #14, OMG 3" Round Metal Plate
9-inch o.c. in 4-inch lap and 9-inch
W-61
inch plywood
layers, any
Attached
Polyglass APP Base
with OMG HD, OMG Flat Bottom Plate
o.c. in four (4), equally spaced,
(Optional) APP-TA
APP-TA
-90.0--
combination
(Accutrac) with Roofgrip #14 or Trufast 3"
staggered center rows
Metal Insulation Plate with Trufast HD.
Min. 15/32-
One or more
Prelim.
Trufast #12 DP or Trufast #14 HD with
6-inch o.c. at 4-inch lap and 6-inch
(Optional) BP -AA
W 62
inch plywood
layers, any
Attached
Elastobase, Elastobase P
Trufast 3" Metal Insulation Plates
o.c. in three (3), equally spaced,
or SBS-AA
SBS-AA
-90.0
combination
staggered center rows
Min. 15/32-
One or more
Prelim.
OMG #12 Standard Roofgrip or OMG #14
6-inch o.c. at 4-inch lap and 6-inch
(Optional) BP -AA,
SBS-AA, SBS-
W-63
inch plywood
layers, any
Attached
Elastobase, Elastobase P
Heavy Duty with OMG 3" Round Metal
o.c. in three (3), equally spaced,
SBS-AA, SBS-TA,
TA or APP-TA
-90.0
combination
Plates or OMG Flat Bottom Metal Plates
staggered center rows
APP-TA
Min. 15/32-
One or more
Prelim.
OMG #12 Standard Roofgrip or OMG #14
6-inch o.c. at 4-inch lap and 6-inch
W-64
inch plywood
layers, any
Attached
Polyglass APP Base
Heavy Duty with OMG 3" Round Metal
o.c. in three (3), equally spaced,
(Optional) APP-TA
APP-TA
-90.0
combination
I
I
Plates or OMG Flat Bottom Metal Plates
staggered center rows
Min. 15/32-
One or more
Prelim.
Trufast #12 DP or Trufast #14 HD with
6-inch o.c. at 4-inch lap and 5-inch
(Optional) BP -AA
W-65
inch plywood
layers, any
Attached
Elastobase, Elastobase P
Trufast 3" Metal Insulation Plates
o.c. in five (5), equally spaced,
or SBS-AA
SBS-AA
120.0
combination
staggered center rows
Exterior Research and Design, U.C. d/b/a Trinity I ERD
Certificate of Authorization #9503
Prepared by: Robert Nieminen, PE-59166
6T" EDITION (2017) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (570) 384-1230
Evaluation Report P9290.02.08-1120 for FL1654-R22
Revision 20: 09/12/2017
Appendix 1, Page 14 of 58
71-
a + .,t.._ a-arr �. -fr ,_ tom. - - •F_� _. _ x - -.. - _. - T .a_ _ ,\ Y '. lam _ _ „n ,n
- a .. ss. a u �. b=+�. .� . � a .i'a�' , - - .�...;- ns'�¢Sa ♦-_fi_.c.-� . - -._ •`E _.--
_. �-_• . s.._+Ma. y.._._ ft . 1 , , ,- ter... _ -••_ .. .. _ - 2 _ � -
..yam
... .. �-y._-,� � ..`—.. •. a. a n. ....♦ �4�: 1t _ - r.. ... �. �Ft.'1.z .._ .. sue. .e .\ ... Y _� __
- - a r .. - . •.�M- . - ' -+fib _ . _ a ♦ -.. .i s -. y-:s4. - 'p�
y-. - _ -.�. .. a < wii• � - i � aF .e-y- .�, .y � �-. ..� - r .�.��{~ -^^ ,ya*G�,:^+w >"�4:i4,iKi*' „
Jataylorroofing.com Mail - Fwd:
Page 3 of 7
JAN 0 9 2019
Permitting Department
St. Lucie County, FL
https://mail.google.comlmaillull/?ui=2&ik=b4be75227f&jsver=BlwOsCQX 4s.en.&cbl=... 6/29/2018
Jataylorroofing.com Mail - Fwd:
Page 4 of 7
https://mail.google.com/mail/u/l/?ui=2&ik=b4be75227f&jsver=B1wOsCQX 4s.en.&cbl=... 6/29/2018
S.•'.Iy'.'4�e.
n.c.
Mvr .
,J
Y;
t<
t
f•
1
L
� li)
_r.� ��' �';,:•�'3`1ylk 8; iWli r'Cr`- mot, �..,
- •� fi' p l � i 1 f t ��i r hq r i �f�i-.�T fl � �\s
� U rr�lr r a. � u y �,•`
artment.
rmitting Dep . , /•� �4 ;�� x fr
r J1
St.=Lucie/ nty,
1 h ,
• t I P.+Q� � _ '
OWN
t. %` SSA #�3ki7sA Sig►�� _ - _ r I rfi.
:era.
GDP WIMIMOMMIMMI
aa�r�Agoa,
-, ,,, ..' ,5 �� ... - '�, �• \� ©a's�®ate;- �'� - - r ! '.�
Ohl
? • OAAAA® i� p 1 �j'/
i OA��I@9L��.
` i V 1� ®aAer�_
Click hero to return to the main PelTnits page.
Permit:1801-0542
Permit Status: Expired
Job Description: REROOF FLAT PORTION ON 2ND FLOOR: TEAR OFF ROOF ROOFING. INSTALL NEW PLYWOOD DECK ON FLAT ROOF. INSTALL NEW POLYGLASS 3-
PLY MODIFIED BrrUMENI, TAPERED FLAT ROOF SYSTEM (4 SQ) W-58
To pay a rehlspection fee, please click ggyjm link for each fee due. You may use Visa, Mastercard, Discover Card,
or echeck to pay the fee using the Govteller gateway.
To schedule an inspection, please select Request for each inspection you would like to schedule. Inspections must be scheduled in the order of the Priority listed below. An inspection will
not schedule until all inspections with a lower Priority number show an "Approved" status and ALL reinspection fees have been PAID.
To add a note for the Inspector for scheduled inspections, please select Add Note • enter note in Inspection Notes textbox below, and click Update link for each inspection you would lik
to add a note for.
If you are unable to schedule an inspection or require any assistance, please contact the Building Division at (772) 462-2172.
Type
Cart# Status Penult Type
Name
Company
Phone Fax Cell
Contractor
23018 Active I ROOF - MODIFIED BITUMEN
KYLE WHITE
3 A TAYLOR ROOFING INC
(772) 4664M
Request
Add Note
Pay Fee
Fee
Cade
Status
Priority
Data Scheduled
Date Inspected
Insp. ID
Comments
Inspection Notes
REQUEST:INSULATION,DRY-
Add Note .
Pay Fee
134 - ROOF
SHEATHING
Cancelled by
Contractor/Customer
1
5/11/2018
5/11/2018
237
IN 9 PROGRESS
INSPECTIONS ALSO —Web
5/10/2018 4:23:08 PM.
162 - ROOF
AFFIDAVIT -
Add Note
I Pay Fee
- TURN
Approved
1
6/20/2018
6/20/2018
0
INTO
OFFICE
1) WITHDRAW TEST WAS
NOT SUBMITTED, PLEASE
SUBMIT WITHDRAW
TEST ([A] 107.2.1), 2)
908 -
ARC HTTECT'S LETTER
Add Note
Pay Fee
DEFERRED
SUBMITTAL
Disapproved
1
4/18/2018
4/17/2018
111
CODE REFERENCE DOES
NOT REFLECT BITUMEN
- OFFICE
ROOF SYSTEMS ([A] '
107.2.1), 3) PROTECT
SITE DOES NOT MEET
THE DEFINITION OF
EXPOSURE B (R901.2.1.4)
REINSPECfION.
PLEASE PROVIDE
WITHDRAWAL
RESISTANCE TEST
908 -
REVIEWED BY A DESIGN
PROFESSIONAL (PER
Add Note
Pay Fee
SUBMITTAL
Accept w as no
1
4/27/2018
4/26/2018
111
PAGE 2, NOTE 11 of
OFFICE
FOLYGLASS PRODUCT
APPROVAL FL1654-R22).
NEW ROOF DECK
INSTALLED, TEST
I
REQUIRED FOR
t
EXISTING DECKS*
Add Note
Pay Fee
134 -ROOF
Cancelled by
1
6/18/2018
6/18/2018
39
Rqst Insulation, Drying I f
Progress Inspections— -- Web
SHEATHING
Contractor/(usto m�
6/15/2018 327:01 PM.
In progress Inspection. A
lot of rotten material.
Rqst Insulation, dryln t
Add Note
Pay Fee
134 - ROOF
SHEATHING
Partial Approval
1
6/19/2018
6/19/2018
237
Roof framing members
and plywood being
progress Inspection also --
Web 6/18/2018,4:30:42
replaced as needed.
PM.
Contractor to submit
Photos as Well
RQST
Add Note
Pay Fee
134 - ROOF
SHEATHING
Approved
1
6/20/2018
6/20/2018
eb
INSPECTION— Web
6/20/201B 9:35:25 AN.
TAPERED INSULATION
roof was finished without
other inspections being
done 110.1 FBC roof Is
holding water and does
Final Inspection requested__
Add Note
Pay Fee
141- INSULATION
Disapproved
2
6/22/2018
6/22/2018
39
nothave 7�: a
Web 6/21/2018 2:43:12
railing on roof must be
PM.
reinstalled before final
Inspection 312.1 rbe
separate permit required
' with engineering
Add Note
Pay Fee
141 -fD11.1
2
1
/26/2018
'
237
RENSPECfION. I do not
Final Inspection requested:
—"—
INSU
;• ••
Imaw If drainage Issue is
No
-Web 10/25/2018 8:01:32
AM.
E
I
1Ithe
--
'
:%`
resolved. answer at
door. Inspector Smyth'Rr..
said a permit and raiing
E
��
I
must completed before
Final Inspector. Thla has
n
not been dorhe. Photosfprovided
for dry In plates
JAN p 9
2019
and screw attachment
Nabs have been left
exposed In verbal
flashing at one door.
mit
9 Tim
in D
I
These need to be sealed
or replaced wrth screws
t. Lucie
r
lnf-t/ 01
n
1`
and neoprene washers.
"71 I L- I
i
%
FtlLYU3.1
'
Final Inspection for roof
requested,drainageIssue
-
Conoracinr/Cus4omer lled by
hberesolved. Please
as
Add Note
pay pee
INS
INSULATION
Contractio
1 2
10/30/2018
10/30/2018
237
REINSPEMON.
call Ryan 772-260-7S92 to
i
diswssr railing done by
home owner.— Web
t
10/29/2018 2:30:16 PM.
-
Need engineer Is for
Final Inspection requested —
Add Note
Pay Fee
INSULATION
INS
Disapproved
2
12/20/2018
12/20/2018
39
fni
Insulation roof Is Bnished
Web 12/19/2018 4:06:55
PM.
Add Note
Pay Fee
141 -
INSULATION
2
RL7NSPECIION.- .
136 - ROOF
Add Note
Pay Fee
DRY-INMN
3
BASE SHEET
TAB
149 -
Add Note
Pay Fee
PROGRESS
4
IF NEEDED 80.5E PLY
INSPECTION
Add Note
Pay Fee
O
S
PLY
I99959FE
................................. I .....................
Anothe�;PerrnLt:
RFrV'T11fVV%
Per
c