Loading...
HomeMy WebLinkAboutLETTERArch itecto" -n" ic Inc City of Fort Pierce Building Department 100SUSHwy 1 Fort Pierce, FL January 7, 2019 RE: Cataldo Residence 675 SE Hidden River Drive, SLC SCANNED BY St Lucie County Permit # 1801-0542 To Whom It My Concern: i Please be advised that Architectonic Inc. has reviewed the permit inspections, photos and here by certify that the following has been done in accordance with the Florida Building Code and Florida Product Approval (FL# 1654.1) I *Re -roof Flat roof 400 sq. ft. *Tapered insulation preliminary attached Poly Glass, Elasto base mechanically fastened into wood deck using Dekfast screws and plates @ 9" O.C. in 4" lap and 9" O.C. in four equally spaced staggered center rows. (1) ply Polyglass Torch applied smooth modified, (1) ply Polyglass Torch applied granulated Modified (white). *60 day cure time *2 coats Gaco Waterproofing System installed over entire roof. *50 year Manufacture's material warranty, ixec JAN 4 9 2019 Department permittic e nty, f - St. Lu 806 Delaware Avenue Tel: 772 460 7751 www.architectonicinc.com Fort Pierce, Florida 34950 Fax: 772 460 4244 FL Reg #AA26003348 1 of 1