Loading...
HomeMy WebLinkAboutGENERATOR16/20/22 W RECEIVED JAN 2 4 2018 ST. Lucie Crn rnfv. PPrmittinn GENERAC fM910 BY Ist Lucie Cwty t1 �jhM1 [. J . r.i 1:1 �1 ti1z-J INCLUDES: • True Power'' Electrical Technology • Two Line LCD Multilingual Digital EvolutionT" Controller (English/Spanish/ French/Portuguese) GUARDIAN® SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models 006459-0, 006461-0, 006462-0 (Steel - Bisque) - 16 kW 60 Hz - Model 006721-0 (Aluminum - Gray) - 16 MAI 60 Hz Models 006729-0, 006730-0 (Steel - Bisque) - 20 kW 60 Hz Models 006551-0, 006552-0 (Aluminum - Gray) - 22 kW 60 Hz Two Transfer Switch Options Available: 100 Amp Pre -Wired Switch or ST.LUCIE COUNTY 200 Amp Smart Switch. PLAN REVIEW See Page 4 for Details. • Electronic Governor BLDG:_� • External Main Circuit Breaker, System S Maintenance Interval LED Indicator§LEC• • GFCI Duplex Outlet DATE: • Sound Attenuated Enclosure PLUMB. • Flexible Fuel Line Connector DATE:_� MECH:_._� • Composite Mounting Pad DATE: • Natural Gas or LP Gas Operation • 5 Year Limited Warranty • Capability to be installed within 18" (457 mm) of a building* c us QUIFF••. LISTED Note: CUL certification only applies to unbundled units and units packaged with pre -wired switches. Units packaged with the Smart Switch are UL certified in the USA only. *Only if located away from doors, windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. of GENERAL'S success in "IMPROVING POWER BY DESIGN." But it This state-of-the-art power maximizing regulation system is standard on doesn't stop there. Total commitment to component testing, reliability all Generac models. It provides optimized FAST RESPONSE to changing testing, environmental testing, destruction and life testing, plus testing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by to applicable CSA, NEMA, EGSA, and other standards, allows you to electronically torque -matching the surge loads to the engine. Digital choose GENERAC POWER SYSTEMS with the confidence that these voltage regulation at ±1 %. systems will provide superior performance. O TRUE POWER" ELECTRICAL TECHNOLOGY: Superior harmonics O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer and sine wave form produce less than 5% Total Harmonic Distortion for network provides parts and service know-how for the entire unit, from the utility quality power. This allows confident operation of sensitive electronic engine to the smallest electronic component. equipment and micro -chip based appliances, such as variable speed HVAC systems. O GENERAC TRANSFER SWITCHES. Long life and reliability are O TEST CRITERIA: synonymous with GENERAC POWER SYSTEMS. One reason for this PROTOTYPE TESTED v NEMA MG1-22 EVALUATION confidence is that the GENERAC product line includes its own transfer SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY systems and controls for total system compatibility. GENERAC® GENERAC® 16/20/22 kW features and benefits Engine • Generac (OHVI) design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma moly rings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • Quiet -Test" Greatly reduces sound output and fuel consumption during bi-weekly exercise, compared to other brands. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. -Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. -Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featuring up to a 2 year/200 hour oil change interval. -Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. -High temperature shutdown Prevents damage due to overheating. Generator -Revolving field Allows for a smaller, light weight unit that operates 25% more efficientlyban a revolving armature generator. -Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. -Displaced phase excitation Maximizes motor starting capability. -Automatic voltage regulation Regulates the output voltage to ±1% prevents damaging voltage spikes., • UL 2200 listed For your safety. Transfer Switch • Fully automatic Transfers your vital electrical loads to the energized source of power. -Pre-wired, color -coded conduits Ensures the easiest, trouble -free installation. (Pre -wired switches only) • DPM Technology Digital Power Management Technology allows for the smart control of two air conditioners without any additional (Smart Switch only) items. -Remote mounting Mounts near your existing distribution panel for simple, low-cost installation. Evolution'" Controls -Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, at -a -glance status indication in any condition. -Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences -Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 60% dropout, 80% pick-up,; of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately 1 minute. • Programmable exerciser Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week: Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. -Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. -Electronic governor Maintains constant 60 Hz frequency. Unit -SAE weather protective enclosure Sound attenuated enclosure ensures quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel for security. Lift -out front for easy access to all routine maintenance items. Electrostatically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. -Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building.* Installation System •1 ft (305 mm) flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. -Composite mounting pad Eliminates the need to pour a concrete pad unless required by local municipalities. 16/20/22 kW GENERAC® specifications Generator 006459-0, 006461.0, 006462- 006729-0, 006730.0, 006551-0, 006552-0 Model 0, 006721.0 (16 kW) (20 kW) (22 kW) � a-�pior-� x•r�m�mr �m�c �, %rdiL' ,/ y%�..r,"��rr ."'.�'//'�fi���""" ��z�i. ,i�'"y^,ri���v r - . ;�, �/' ���,..,rm�r r..�7�rs °-RatedijlaximGm Continuous Power Ga�acHy�'� ,w�„p� .=�,-�,,, �i~i 000_C�attsx� �� �e f, ••20 000 Wags" �� 22 OOO:Waftsy , Rated Maximum Continuous Power Capacity (NG) 16,000 Watts' 18,000 Watts' 19,500 Watts' ,.m..,_. it .. i , ,,, Odij/ >. car r-r In r .� rr,-.•^r .,�. .f..�z Rated Maximum Continuous Load Current— 240 Volts (LP/NG) 66.6/66.6 83.3/75 / 91.6/81.3 ': otai•Hafmoilfe-D��/,y�b/�///�i : ��� �/ %���"���„,�"'�j",;a Lass l a SY���i/ �, �y/�,,;t_SS nth 5%,f �/!'A� y.i;.;,��tess;thah,5• ,� Main Line Circuit Breaker 65 Amp 90 Amp 100 Amp .�w/i.,y,,.�.eSr�G_���4w'��.,�....��,�u,�,r...�.<..»..�..�_,.,.:.;,%�',�.,;.aa' ,.,«/�,.../��✓,;,���"u�✓,.�..' _¢w.�.0-.w._:�»,.,_. ,�m✓„,.:,�5 Number of Rotor Poles 2 2 2 Power Factor 1.0 1.0 1.0 Unit Weight (Ib/kg) 513/232.7 (Steel); 516/234.1 526/238.6 448/203.2 (Aluminum) Sound output in dB(A) at 23 It (7 m) with generator operating at normal load" 66 66 67 Exercise duration 5 min 5 min 5 min Engine �°��Y1?B'oL�����'a���,�/i'/� /i��/%��,u%/ ✓�� � R���Qi��a�� ENERAG OJiV1;��,.��6u°w:l� .��iGENEtiAC OHVI V�!����a Number of Cylinders 2 2 2 �...,,-r. 7'—^'',.z�r,,� ,�:�' �✓i ,,: r'r' ,;'"�r ;�"..�/ '"'�irrs^ ;^,-� �. r..cl ,h 9..^r nr^-� .-%/ Q1 pi�cemen,] / � ,, ,�7i✓,��:��/. ,�Oc %����/ s�./��da,��,:.,. ��/,� � �2 ;CC w/� ' i �% .%/�99�CC�,�i /_ /�///%� �l! re, „k✓ ,r�ii 99$:CC!��..��ro:. Cylinder Block Aluminum w/ Cast Iron Sleeve ,r .nr�rg � �� �^ //�';�/;�-%% i� ��. ,,,, ;f"�"r�%r/,���.,'",r, ;. �"/,'r 9,r/rr�rir'r. �o s^i ,9i ,</i r ,i „��� :rrmn„� �°// 70 s rRe-ii r�r � EIveA!langemer�# y a/ /�% y, 0yerheadGalve�'r�OverheadUae erg rwuerheadVaiVe Ignition System Solid-state w/ Magneto Solid-state w/ Magneto Solid-state w/ Magneto Compression Ratio 9.5:1 9.5:1 9.5:1 � 7 m--��-.�� �-�-�j,'�^z--°� �-�-'ter,--� � �-- �--�—�-- �-•----~yr'�--- ax S�a����i//��i�i✓�,.�.'�i�,:��"`e//�ri�//�.< �`���'G��.✓�r�<,���/12V�A���G��n�%/�d/��2Ur�c.�r�cv��;,a.�ie�,y��,1�af;:�,�,.u.�W� Oil Capacity Including Filter Approx.1.9 g1/1.8 L Approx.1.9 gV1.8 L Approx.1.9 gV1.8 L �O�elat �z.��y�/��. /�is.�! ,_�%°a_� •.,,,��' /re �./o./ . ,//�_F_�_v�� _ /;ii,�,'��6B�ryyf r. z� ,.�i/y %� �� i i °',�/��mt)B ,.X'S. !://�..�m,,�.� eW a�i...�//..::��v.✓//6 �..a.L.rw,<-.." �G..yoe.%:�i Fuel Consumption Natural Gas fta/hr (ma/hr) 1/2 Load 193 (5.47) 205 (5.8) 184 (5.21) Full Load 312 (8.83) 308 (8.72) 281 (7.96) Liquid Propane ft3/hr (gal/hr) [I/hr] 1/2 Load 72.4 (1.99) [7.53] 75.6 (2.08) [7.87] 83 (2,16) [8.16] Full Load 130 (3.57) f13.531 140 (3.85) [14.571 127 (3.68) [13.9( Controls Mode Buttons: Auto Automatic Start on Utility failure. 7 day exerciser. /x,d� „';'�yr �i �r �i ���c"'a �.y� �;7 i, , ;,�/,i/ /^" /,: r.7 ,r/"""vr . ��///�Fi'r era ..,, .'r�7r r„r�v.,o , . ,,,-,�'¢rr� v ,.., r':rrrrw�i.,,,m.,�;.,m'-,�r„^:a• im•--' . x Off Stops unit. Power is removed. Control and charger still operate. Engine Run Hours Indication Standard Pi mm�abie slarf delayiatw6 2StO sends�.� ��, 5}ndarprdgramr bolo bdealeroai „ Utility Voltage Loss/Return to Utility Adjustable (Brownout Setting) From 140-171 V/190-216 V RurVAlafm/Maintenance Logs 50 Events Each Starter Lock -out Starter cannot re-engage until 5 sec after engine has stopped. Charger Fault/Missing AC Warning Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Safety Fused/Fuse Problem Protection Standard Overcrank/Overspeed (@ 72 H2)/rpm Sense Loss Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard "GommO L'�E e(nal F Glt Ca 96d1 j %%, �% �"�"'y/"v��'y",/rn�` '�;?�„�r //r"'�,��"— � ,/Fr�/r7��jj^noy �� �r'�^ m-�.� y y-nx�� r ��-�v�-�^;—�- -m✓ s u4w,....»..u_� ,.[� � 1.�,.»'S�:,Siw.,,�.- .1,�,_,.�a...,..z�L_��_.._�.s..w,,....�._��...✓c�w„ G,.,.?cv/u�.,.L_,w�:o:<zv:�..,,standarlt,:✓.���,�. �,✓.r .��.�..M�u�ttsuda:• :. Field Upgradable Firmware Standard "Sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may be higher depending on installation parameters. Rating definitions- Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, IS03046 and DIN6271). ' Maximum wattage and currentare subject to and limited by such factors as fuel Btu/megajoule content, ambient temperature, altitude, engine power and condition, etc. Maximum power decreases about 3.5 percent for each 1,000 feet (304.8 meters) above sea level; and also will decrease about 1 percent for each 6 °C (10 `F) above 16 `C (60 T). 16/20/22 kW Pre -wired Features available on Steel 16 kW models only • Electrically operated, mechanically -held contacts for fast, positive connections. • Rated for all classes of load, 100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA 1 (indoor rated) enclosure is standard on the pre -wired switch. • Pre -wired 30 foot (9.1 meter) whip to connect to the provided 5 foot pre - wired whip and external connection box. • Pre -wired 2 foot (0.61 meter) whip, color coded to connect into the existing electrical panel. Dimensions GENERAC® switch options Model 006461-0 (16 kW) Current Rating (Amps) 100 Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 60% Exercise weekly for 12 minutes* Standard �A//r%%//�% RUCLtSied.�,6//u ll :<« Total of Pre -wired Circuits 16 No. 15A120V 5 No. 20 A 120 V 5 No. 20 A 240 V 1 No. 30 A 240 V - No. 40 A 240 V 1 No 50 A 240 V 1 l;l CUI�i ���a4�ErCP otE�d o y r i �r�j.,yyA �Gi�t18 RM$ $�i1lmEtrlCdl iyj/rr✓///�� �� r� %� �� �/Y�i � �i ° i/ Oi ✓,s /i i✓/ ✓ - �Y �is�� � a9 9� �/�:�/,y rid .�// �a G// r /� r /ice /�,...Yv,.�v�a��i�..,/��,��r/.G,,,u�...✓.✓�,,,,�,� r.�,,,,,.� „<J�,��,ra� � u.�,r�,:.,, .� ✓c „Ar..� *Function of Evolution Controller Mechanical Dimensions Height Width Depth H1 H2 W1 W2 in 23.5 1 26.4 8.3 12.6 6.3 mm 597 1 671.7 211 320.7 159.6 Wire Ranges Conductor Lug Neutral Lug Ground Lug 2/0 - #14 2/0 - #14 2%0 - #14 Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages two air conditioner loads with no additional hardware. • Up to four more large (120/240 VAC) loads can be managed when used in conjunction with Power Management Modules (PMM**). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load,100% equipment rated, both inductive and resistive. • 2 pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • NEMA/UL 313 aluminum outdoor enclosure. • Main contacts are silver plated or silver alloy to resist welding and sticking. **Note: PMM starter kit is required prior to using the modules. Dimensions 200 Amps 120/240, ie Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 27.24 30.0 11.4 1 13.5 7.09 mm 1 692.0 762.4 289.0 1 343.0 180.0 Model 006462-0 (16 kW)/006729-0 (20 kW)/006551-0 (22 kW) Current Rating (Amps) 200 6Vol�a9,„�R�ttng,N.,��)yx�F✓ �„�,,�,u�.u_�.._��::r'�'>�2&�a�-:�...���� �,,:;,, Utility Voltage Monitor (Fixed)* -Pick-up 80% -Dropout 60% Exercise weekly for 12 minutes' Standard ,—��� ��,,'Standard ' :�,✓,�.�� , Enclosure Type NEMAIUL 3R _ Lug Range - 250 MCM - #6 *Function of Evolution Controller w1 x y 'Xm y y y „y HI C ! 0/ 0,' t DEPTH t Wp GENERAC" 16/20/22 kW available accessories Poduct Desctiptton i / Generac's Mobile Link allows you to check the status of your generator from anywhere that you have 006463-1 Mobile Link" access to an Internet connection from a PC or with any smart device. You will even be notified when a change in the generator's status occurs via e-mail or text message. 005819-0 26R Wet Cell Battery Every standby generator requires a battery to start the system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact®). If the temperature regularly falls below 32 °F (0 °C), a cold weather kit is required to maintain optimal 006212-0 Cold Weather Kit battery and oil temperatures. Kit consists of a battery warmer and oil filter heater with built-in thermostats. 005621-0 Auxiliary Transfer Switch Contact The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical Kit load you may not need. Not compatible with 50 amp pre -wired switches. 005839-0 - Bisque Fascia Base Wrap Kit* The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers 005666-0 - Gray (Standard on 22 kW) a sleek, contoured appearance as well as offering protection from rodents and insects by covering the lifting holes located in the base. 005703-0 - Bisque If the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect 005704-0 - Gray 1 Paint Kit* from future corrosion. The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. 006484-0 -16 kW Generac's scheduled maintenance kits provide all the hardware necessary to perform complete 006485-0 - 20 & 22 kW Scheduled Maintenance Kit routine maintenance on a Generac automatic standby generator. Completely wireless and battery powered, Generac's wireless remote monitor provides you with 006664-0 Wireless Remote Monitor instant status information without ever leaving the house. Not compatible with CorePower or EcoGen systems. The PMM Starter Kit consists of a 24 VAC, field installed transformer that enables the use of the 24 006199-0 PMM Starter Kit VAC Power Management Modules (PMMs)and one PMM. The standard controller (without starter kit) can control two HVAC loads with no additional hardware. Not compatible with pre -wired switches. Power Management Module (50 Power Management Modules are used in conjunction with the Smart Switch to increase its power 006186-0 Amps) management capabilities. It gives the Smart Switch additional power management flexibility not found I in any other transfer switch. Not compatible with pre -wired switches. Note: PMM Starter Kit required. * Note: Bisque kits are used in conjunction with steel enclosures. Gray kits are used in conjunction with aluminum enclosures. dimensions & UPCs Dimensions shown are approximate. Refer to installation manual for erect dimensions. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES Lzb.a m1 LEFT SIDE VIEW GENERAC' 1218 mm [47.9 In] 117771 5" / �%� %e y 1226 mm [48.3 In] FRONT VIEW Model UPC 006459-0 696471064599 0064610 696471064612 006721-0 696471067217 006729-0 696471067293 006730-0 696471067309 006551-0 696471065510 006552-0 696471065527 006462-0 1 696471064629 Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com 02014 Generac Power Systems, Inc. All rights reserved. All specifications are subject to change without notice. Bulletin OK8458-D Printed in U.S.A. 06/19/14