HomeMy WebLinkAboutWIND SPEED BY LOCATION_;Search Results for Map �iIN�CY Page 1 of 1 -� BY 0 ASCE 7 Windspeed ASCE 7 "Ground Snow Load Related Resources Sponsors About ATC Contact Search Results Query Date: Mon Jan 08 2018 Latitude: 27.3098 Longitude:-60.2999 ASCE 7-10 Wlndspeeds (3sec peak gust in mph*): Risk Category 1:148 Risk Category 11:160 Risk Category III -IV: 172 MRI" 10-Year. 88 MRI" 25-Year: 107 MRr' 50 Year. 120 MRI" 100-Year: 131 ASCE 7-05 Windspeed: 141 (3-sec peak gust in mph) ASCE 7-93 Windspeed: 100 (fastest mile in mph) 'Miles perhour -'Mean Recurrence Interval Users should consuR with local building officials to determine If there are commun8y-specific wind spx0 requirements that govern. aPrint Your results .4 EBSIT WINDSPEED WE DISCLAIMER While the Information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the windspeed report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or othbr licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the windspeed report provided by this website. Users of the Information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitudellongitude location in the Windspeed load report Sponsored by the ATC Endowment Fund - Abrified Technoloov Council - 201 Redwood Shores Parkway, Suite 240 - Redwood City, California 94085 - (650) 5954542 .e htlp://windspeed.atcouncil.org/mdex.php?option=corn content&viev�article&id=10&dec=... 1/8/2018 CONTRACTOR: King Carter Aluminum„"" DESIGN CRITERIA: Applicable Codes Regulations and Standards 1. The 6th Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Altnninum, and Chapter 23 Wood 2. AA ASM 35 and AA ADMI Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association. and the AAF Guide to Aluminum Construction in High Wind Areas. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 - 2. Dead Load 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5: Risk Category1. 3.2. Basic Wind Speed, Figure 1609.3(3), State of Florida Debris Region & Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed VULT = 150 MPH, VASD - 116MPH 3.3. Exposure Category, Section 1609.4.3: ExposureB 3.4. Screen Enclosure Section 2002.4 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 1- Patio Cover: Non -Habitable, Unconditioned Scope of Work• Replacement of carport only . Does not include analysis of remaining existing structure. Roof Type 1. Roof Type: MONOSLOPE 2. Roof Material: 3" a 49" x 0.024" Elite 2000 Composite Panel, 1.0 N density foam. Florida Product Approval Number FL 7561-R4. Foundatioa Design Existing slab No additional concrete footing or slab is required to resist the loads imposed upon the existing slab by the proposed construction if the existing slab is a minimum of 4" thick and in sound condition, free from structural cracking, spalling, or other deterioration. Specifications The following specifications are applicable to this project 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 T5 Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Suncoast Aluminum Engineering, LLC. 3. Screen Material: Design based on 18/14 or 20/20 Better View. Any other material must be approved 4. Fasteners are required to be corrosion resistant, minimum SAE Grade 2 or better zinc plated to ASTM B633, or coated stainless steel series "300", or uncoated stainless steel series "400".. 5. All Self Mating Beam Sections are to be stitched with either 914 screws 6" from ends and 24" center to center or Al2 screws 6" from ends and 12" center to center. 6. Door location shall be determined by contractor in the field 7. Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: L Portland Cement Type 1,- ASTM C 150 iL Aggregates - Large Aggregate 3/4" max - ASTM C 33 HL Air entraining +/- l% - ASTM C 260 iv. Water reducing agent - ASTM C 494 v. Clean Potable water vL Other admixtures not permitted In . Metal accessories shall conform to: L Reinforcing Bars - ASTM A615, grade 60 E Welded wire fabric - ASTM Al85 c. Concrete slump at discharge chute not less than 3" or more than 5". Water added after batching is not permitted d Prepare and place concrete per American Concrete Institute Manual of Standard Practice, Parts 1, 2, and 3 including hot weather recommendations. e. Moist cure or polyethylene curing permitted f Prior to placing concrete, treat the entire subsurface area for termites in compliance with the FBC. g. Concrete shall be placed over a polyethylene vapor barrier. h. All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 8. All lumber and plywood shall have grade marks and treatment identification and Shall conform to the following: a. Framing lu nber shall be minimum no. 2 southern yellow pine and have a maximum moisture content of 15%. b. Pressure treatments shall be osmosalts, osmose k-33, womansalts or celcure, as recommended for the use condition. Pressure treated lumber shall be impregnated with a cca salt treatment in accordance with fs. tt-w-571 and bear the American Wood Preservatives Institute quality mark 1p-2. c. Wall Sheathing: APA rated Sheathing• thickness as indicated, Exposure 1. d Aluminum members that are uncoated shall be separated from PT lumber by 301E felt paper, 10 mil polyethylene sheet or equivalent material. 9. Contractor shall provide Florida Product Approval information as to the exact window being utilized for this project, including manufacturers specifications, and installation methods for anchoring the submitted windows to Aluminum members and specific sizes as indicated on A-1. 10. Contractor shall provide any additional backing and anchors as required by the window manufacturers recommended procedures. 11. All glass panels within 24" of a door opening shall be of tempered glass per FBC-R308.4 12. All flashing and weatherproofing shall be provided by the contractor. 13. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND E"71URE HAVE BEEN DETERMINED, `JG THE ADVANCED TECHNOLOGY COUNCIL'S WEBSTTE AND GOGGLE EARTH. .,ONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBILITY OF THE CONTRACTOR OF RECORD I 9'-4" I 3X3XO.093 POST EXISTING1 CARPORT- 3X3XO.093 POST 7'-9" _ T Of I ELITE 2000 COMPOSITE PANEL: (FPA:FL7561-R4) 150MPH/EXP B 3"x48"xO.024" (1.0# DENSITY FOAM) MAX SPAN: q-q = 12'-9" THESE PLANS AND ALL PROPOSED WORT: ARE SUOJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSMY IN ORDER TO COMPLY WITH ALL APPt,I044 OOIDESt 7'-0" 2X3 END BEAM 7'-0" ST. LUCIE COUNTY BUILDING DIVISION RKV1C-WE FOR COM PL REVIEWED BY DATE 2-1, PLANS AND PERE4IT MUST BE KEPT ON JOB OR 1`=0 INSPECTION WILL SE MADE 7'-0" 4'-0" - 2X4SMB 4TH WALL 3"X48"XO.024" �I )# DENSITY FOAM )MPOSITE PANEL EXISTING A-2 EDGE BEAM 2X3 KNEE BRACE(TYP) 3X3XO.093 POST 7'-0" - 7'-0" 19,-0" - 3X3XO.093 POST 7'-0" 4'-0" 3"X48"X0.024" COMPOSITE PANEL 4'-0" �- 9'-4" I 1'-0" x L R Y E Q Z3 ❑ W Li 0 a d W r CC LL Z ro W m O �� m Q m J m LLI t1 = O LU z p Z ^2z <Z Z == O:3 W F- d cc LL ZUo J Q � m _ og Z $m N � rim m cs g N Y aW W , C, a, O W In C in rd W lZu UZ��Ilp C9 �3^- U :3Z o Z Mu (n W o W Z EXISTING DRAWN BY WOOD FRAME GD SHED DATE DRAWN 01/11/18 REVISION 11 QLUNIINUM MEMBERS DEMNSI(` HOLLOW SECTIONS 2 x 2: 2" x 2" x 0.046" 2 x 3: 2" x 3" x 0.050" 2 x 4: 2" x 4" x 0.050" 2 x 5: 2" x 5" x 0.050" OPEN BACK SECTIONS 1x2: 1"x2"x0.040" 1x3: 1"x3"x0.045" SNAP SECTIONS 2 x 2 Snap: 2" x 2" x 0.045" 2 x 3 Snap: 2" x 3" x 0.050" 2 x 4 Snap: 2" x 4" x 0.045" SELF MATING (SMB) 2 x 4 SMB: 2" x 4" x 0.044" x 0.100" 2 x 5 SMB: 2" x 5" x 0.050" x 0.100" 2x6SMB: 2" x 6" x 0.050" x 0. 120" 2x7SMB: 2" x T'x 0.05T'x 0. 120" 2 x 8 SUB: 2" x 8" x 0.072" x 0.124" 2x9 SUB: 2" x 9" x 0.072" x 0. 124" 2 x 10 SMB: 2" x 10" x 0.092" x 0.398" NDNIMUM FASTENER EDGE DISTANCE:1/2" MINIMUM FASTENER SPACING: 3/4" CONCRETE SCREW ANCHOR: SIMPSON TITEN HD OR EQUIVALENT SHEET METAL SCREWS (SMS): ITW / BUILDEX OR EQUIVALENT #14 x 4 7/8" SMS W/ 1 1/2" DIA. NEOPRENE FACED WASHER @ 8" O.C. 3" x 0.062" ALUM RECEIVING CHANNEL W/ #10 x 3/4" TOP AND BOTTOM AS END CAP EXISTING EDGE BEAM 3" x 3" x 0.093" COMPOSITE PANEL 1 1/2" x 2118" x 1 1 /2" x 0.092" x 3" LONG ALUM RECEIVING CHANNEL W/ (3) #14 x 3/4" SMS EACH SIDE OF BEAM & (2) 3/8" DIA. THRU BOLTS INTO POST S-1 COMPOSITE ROOF TO POST A CORNER CONNECTION A_2 SCALE: NTS (2) 3/8" DIX CONCRETE SCREWANCHORS (W CONC. EMBED) x 3" x 0.093" INTERNAL/EXTERNAL 3" x 3" x 1/8" EXTRUDED POST BASE W/ (2) 3/B" DIA. THRU BOLTS B 3" x 3" POST TO CONCRETE CONNECTION DETAIL A-2 SCALE: NTS #14 x 4 7/8" SMS W/ 1 1/2' FACED W 3" F rS-2 COMP. ROOF TO POST 4TH WALL DETAIL A_2 SCALE: NTS 3" x 0.06', RECEIVING Cl W/ #10 x 3/4" T BOTTOM AS E Q �r :z O Q_ #14 x 4 7/8" SMS W/ �- I U -4-0 O H Z '- o .1 1/2" DIX NEOPRENE FACED WASHER@8"O.C. i) N'. Z d' . N ; (n ykE'n•"^�'' •...•••' PROk 366ULSEAL COMPOSITE PANEL S COMPOSITE ROOF TO POST CONNECTION A-2 SCALE: NTS #14 x 4 7/8" SMS W/ 1 1/2" DIA. NEOPRENE FACED WASHER @ B" O.C. 3"COMPOSITE ROOF PANEL 2"x3"x0.059' I = END BEAM 1 1/2" x 21/8" xl 1/2" x 0.062" ALUM RECEIVING CHANNEL W/ (3) #12 x 3/4" SMS EACH SIDE OF BEAM & (2) 3/8" DIA THRU BOLTS INTO THE POST 2" x 4" S-3 NOMP. ROOF TO CORNER POST 4TH WALL DETAIL A_2 SCALE: NTS 0 Ov LLI Ld L' a a Lr LLI z I cn 1 m LL O Z W W °° 2 c" Q m J m 2 LLI a L Z a W 0 W �Z az C7 0= Zwu F = Lu I=- LL LL a r% Z .� U J Vr Q Z o$ z m 00 V1 � ��,�5 LU W TT S Q R O LLl V Q N N Z Z �� 9 W Z g 2 L/Y � W m W 0. Lu . Q my F. J m" o�co0 co � a m�CLU- GD DATE DRAWN 01/11/18 REVISION A SHEET NO: A-2