FL11651-R3x
Revision
2017
Approved
Al
Gulf Coast Supply & Manufacturing, LLC.
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352)498-0778
info@gulfcoastsupply.com
Ray Bowen
info@gulfcoastsupply.com
David Eng
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
info@gulfcoastsupply.com
David Eng L
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
david.eng@gulfcoastsupply.com
ST. LUCIE COUNTY
BUILDING DIVISION
REVIEWED
FOR COMPLI
REVIEWED BY
DATE
PLANS AND PER T
MUST BE KEPT ON B OR
NO INSPECTION WIL BE MADE
f+ g
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden
Wj Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
FL11651 R3 COI CertofIndeoendence 2017-10-09.odf
Standard
Year
FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL1897
2012
UL 580
2006
https://www.floridabuilding. org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgsQFc5K%2f Tr... 2/9/2018
Florida Building Code Online
Page 2 of 3
Equivalence of Product Standa
Certified By
Sections from the Code
v
Product Approval Method
Method 1 Option D
!�
Date Submitted
10/10/2017
Date Validated
10/12/2017
Date Pending FBC Approval
10/17/2017
Date Approved
12/12/2017
Summary of Products
Go to Page F-1 `b I Cl Page 2 / 2
FL #
Model, Number or Name
Description
11651.21
26 Ga. GulfRlb
Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 21 R3 Metal Roof Panel Detail -
sioned.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-164.2PSF
Created by Independent Third Party: Yes
Other:-109.25 psf @ 24" o.c. fastener spacing.
Evaluation Reports
-164.25 psf @ 12" fastener spacing. Install per
FL11651 R3 AE FL11651 21 R3 26GulfRib 1x4 15-
32Plywood Non HVHZ-siioned.pdf
manufacturer's details. Not for use in HVHZ Zones
Created by Independent Third Party: Yes
i
1165 2F 26 Ga. GUIfkib
Min 26 Ga. GulfRib over 15/32" Plywood
emits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 22 R3 Metal Roof Panel Detail -
signed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
D Si 1 P e sure / /- 9.2PSF
Other: -b9.25 psf @ 24" o.c. astener spacing.
Created by Independent Third Party: Yes
Evaluation Reports
- 15f ng. Install per
FL11651 R3 AE FL11651 22 R3 26GulfRib 15-
manufacturer's details. Not for use in HVHZ Zones
32Plvwood NonHVHZ-sioned.odf
Created by Independent Third Party: Yes
11651.23
26 Ga. GulfRib
Min 26 Ga. GulfRib over 15/32" Plywood
Limits of Use 1
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 11 FL11651 23 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-159.2PSF
Other: -71.75 psf @ 24" o.c. fastener spacing.
Created by Independent Third Party: Yes
Evaluation Reports
-159.25 psf @ 12" fastener spacing. Install per
FL11651 R3 AE FL11651 23 R3 26GuIfRib 15-
manufacturer's details. For use in HVHZ Zones
32Plvwood HVHZ-sioned.ndf
Created by Independent Third Party: Yes
11651.24
26 Ga. GulfRib
,Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 II FL11651 24 R3 Metal Roof Panel Detail -
sioned.ndf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-164.2PSF
Other:-106.75 psf @ 24" o.c. fastener spacing.
Created by Independent Third Party: Yes
Evaluation Reports
-164.25 psf @ 12" fastener spacing. Install per
FL11651 R3 AE FL11651 24 R3 26GulfRib 1x4 15-
manufacturer's details. For use in HVHZ Zones
32Plywood HVHZ-sinned Ddf
Created by Independent Third Party: Yes
11651.25
29 Ga. GulfRib
Min 29 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 25 R3 Metal Roof Panel Detail -
Approved for use outside HVHZ: Yes
sinned.odf
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -76.75 psf @ 24" o.c. fastener spacing.
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
-123.5 psf @ 24" fastener spacing. Install per
FL11651 R3 AE FL11651 25 R3 29GulfRib 1x4 15-
manufacturer's details. Not for use in HVHZ Zones
32Plywood NonHVHZ-sioned pdf
Created by Independent Third Party: Yes
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f Tr... 2/9/2018
Florida Building Code Online
Page 3 of 3
11651.26
29 Ga. GulfRib
Min 29 Ga. GulfRib over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No`
FL11651 R3 II FL11651 26 R3 Metal Roof Panel Detail -
sianed.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A 1
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-146.OP�SF
Created by Independent Third Party: Yes
Other: -71.75 psf @ 24" D.C. fastener spacing.
-146.0 psf @ 12" fastener spacing. Install per
Evaluation Reports
FL11651 R3 AE FL11651 26 R3 29GUlfRib IS -
manufacturer's details. Not for use in HVHZ Zones
32Plvwood NonHVHZ-sioned.Ddf
Created by Independent Third Party: Yes
,
11651.27
29 Ga. Gulfftb
Min 29 Ga. GulfRib over 1x4 Wood Purlins over 7/16" O.S.B.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 II FL11651 27 R3 Metal Roof Panel Detail -
sic ned.pdf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-101.OPSF
1
Created by Independent Third Party: Yes
Other: -101.0 psf @ 24" D.C. fastener spacing. Install
Evaluation Reports
per manufacturer's details. Not for use 'n HVHZ Zones
FL11651 R3 AE FL11651 27 R3 29GulfRib 1x4 NonHVHZ-
syned. df
1
Created by Independent Third Party: Yes
,
11651.28
29 Ga. GUIfRib 1
Min 29 Ga. GulfRib over 7/16" O.S.B.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No I
FL11651 R3 II FL11651 28 R3 Metal Roof Panel Detail -
sioned.odf
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Verified By: Dan Kuhn, P.E. 75519
Design Pressure: +N/A/-116.OPSF
Created by Independent Third Party: Yes
Other: -22.66 psf @ 24" D.C. fastener spacing.
-116.0 psf @ 6" fastener spacing. Install pert
Evaluation Reports
FL11651 R3 AE FL11651 28 R3 29GulfRib 7-160SB NonHVHZ-
sianed.odf
manufacturer's details. Not for use in HVHZ Zones
1
Created by Independent Third Party: Yes
Go to Page = 0
Back Next
Contact Us ::
The State of Florida is an AA/EEO employer. C4[
4211 d Page2/20 0
Phone: 850-487-1824
:: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Instead, contact the office by phone, or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to
Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If
they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
10 ® e�h�kM
'1 Credit. Card
Safe
https://www.floridabuilding. org/pr/pr_app_dtl.aspx?paratn=wGEVXQwtDgsQFc5K%2frr... 2/9/2018