Product Evaluation Report
GULP COAST SUPPLY & MANUFACTURING, LLC.
26 Ga. GulfRibTm Roof Panel over 15132" Plywood
Florida Product Approval #11651.22 R3
Florida Building Code 2017
/Per Rule 61 G20-3
Method: 1 -D
Category: Roofing
ategory: Metal Roofing
:e Method: 61 G20-3.0050)(d)
NON HVHZ
RECEIVED
JAN 2 9 2018
ST. Lucle Cdungy, Pormitting
i7 is , ti
I�.
E•r
,�
Ls
Product Manufacturer:
Gulf/Coast Supply & Manufacturing, LLC.
14429 SW 2nd Place, Suite G30 �`''�""`�''
Newberry, FL 32669 %` OP - r' � N, , -
. S%
Engineer Evaluator:
Dan Kuhn, P.E. #75519
Florida Evaluation ANE ID: 10743
J Validator:
Locke Bowden, P.E. #49704
9450 Alysbury Place
Montgomery, AL 36117
Contents:
Evaluation Report Pages 1 - 5
FL# 11651.22 R3.00TOBER
TM
Compliance Statement:
Product Description:
Panel Material/Standards:
.... , GuIfCoaft
SUPPLY & MANUFACTURING
The product as described in this report has demonstrated compliance with the
Florida Building Code 2017, Sections 1504.3.2.
GulfRibT"^, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage,
through fastenediroof panel over minimum 15/32" Plywood Decking. Non
Structural application.
Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to
Florida Building/Code 2017 Section 1507.4.3.
Paint Finish Optional
Yield Strength' Min. 80.Oksi
Corrosion Resistance: Panel Material shall comply with Florida Building
Code 2017, Section 1507.4.3.
Panel Dimension(s): Thickness: j 0.018" Minimum
Width: i 36" Coverage
Rib Height;' 3/a" Major Rib at 9" O.C.
Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal
1/4" minimum penetration through plywood.
Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4
Substrate Description: Minimum15/a2" thick, APA Rated plywood over supports at maximum 24" O.C.
Design of plywood and plywood supports are outside the scope of this
evaluation. Must be designed in accordance w/ Florida Building Code 2017.
Design Uplift Pressures:
FL# 11651.22 R3 • OCTOBER 5. 2017
Table"A"
,Ma Ix muol'� Ta i fit besign Pressure
69.2,-S � p fMH N
159 2y5 psf
Fastener Pattern
911-9"-9"-9"
6.5"-2.5"-6.5"-
2.5"6.5"-2.5 "-6.5"
Faste `n`er f'aitern Spaun1g
24" O.C.
12" O..C.
De'sign Pressure includes a Safety Factor = 2.0.
GuIfC®ast
SUPPLY & MANUFACTURING
TM
Code Compliance: The product described herein has demonstrated compliance with the
Florida Building CodeI2017, Sections 1504.3.2.
Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load
requirements of the Florida Building Code 2017, as relates to Rule 61G20-3.
Performance Standards: The product described herein has demonstrated compliance with:
• UL 580-06 - Test for Uplift Resistance of Roof Assemblies
• UL 11897-12 - Uplift Test for Roof Covering Systems.
Reference Data: 1. UL 580-94 / 1897-98 Uplift Test
Force Engi leering & Testing, Inc. (FBC Organization # TST-5328)
Report No7117-0062T-07A, B, Dated 02/19/2007
2. Certificate of Independence
By Dan K hn, P.E. (FL# 75519) @ Kuhn Engineering, LLC
(FBC Org i nization # ANE ID: 10743)
Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard.
2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test
Quality Assurance Entity: The manufacturer has established compliance of roof panel products in
accordance with!the Florida Building Code and Rule 61G20-3.005(3) for
manufacturing finder a quality assurance program audited by an approved quality
assurance entity.
i
Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including
Section 1507.4:2 and in accordance with Manufacturers recommendations. For
slopes less than 3:12, lap sealant must be used in the panel side laps.
i
Installation: Install per Manufacturer's recommended details.
Underlayment Shall comply with Florida Building Code 2017 section 1507.1.1.
I
I
I
FL# 11651.22 R3 • OCTOBER 5, 2017
i.IRIOA... , Gulfc6dft
SUPPLY & MANUFACTURING
Roof Panel Fire Classification: Fire classification is nqt part of this acceptance.
Shear Diaphragm: Shear Diaphragm values are outside the scope of this report.
Design Procedure:
FL# 11651.22 R3 •OCTOBER 5.2017
For roofs within the
at a minimum meet
the parameters liste,
for each project in a
using allowable stre
notbe exceeded. n
Hurricane Zone. Ref
product in High Velc
arameters listed on the load table, fastening pattern must
lose listed for the applicable wind zone. For all roofs outside
on the load table, design wind loads shall be determined
:ordance with FBC 2017 Section 1609 or ASCE 7-10
design. The maximum fastener spacing listed herein shall
evaluation report is not applicable in High Velocity
to current NOA or HVHZ evaluation report for use of this
itv Hurricane Zone.
Gulf C&zift
SUPPLY & MANUFACTURING
ENGINEER LOAD TABLE: 26 Ga. GulfRibTM Panel over 15/32" Plywood
Bu(dti�gshaving a R of ears Height s 20 -0"; R of
510 e: 2"/12°
- 12" 12°' Gable orHiP Roof; Wind Speeds 12aQ-
184mph E, pos C R s Categ, tyy !l=nctOsed Building,
based
on Fl r►c1a Bclif'cling Code 2017.
,fe
120
130
140 150
160
170
180
WAND
FASTENER
SUBSTRATE
SPEED
(MIN.
Penetration)
(MIN. 15/32")
ON CENTER
ON CENTER
ON CENTER ON CENTER
ON CENTER
ON CENTER
ON CENTER
SPACING
SPACING
SPACING SPACING
I
SPACING
SPACING
SPACING
ZONE'1#g
15X+l.5"
P{ytNvod
24". TYPE 1
24", iYPE 1
24", TYPE 4 24". TYPE 1
4". TYPE 1
24", i YPE 1
24", iYPE 1
ZONE 2
#9-15x1.5"
Plywood
24", TYPE 1
29% TYPE 1
24% TYPE 1 24% TYPE 1
24", TYPE 1
24% TYPE 1
2V, TYPE 2
z 2dNE 3
#9-15it7 5"
Plywood
Z4", PE 1
ZA", TYPE
24", TYPE 7 12', i YPE i
12", TYPE 2
12". TYPE 2
12", f YP 2
y
1.) PANEL :DES`CRIPTION: GULFRIBTm, MIN. 26 GA., GRADE 80, 36"COVERAGE, 3/4" TALL.
2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL
3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C. FASTENER SPACING TYPE I FASTENER PATTERN, 159.25
PSF 0 12" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING.
4.) PLYWOOD DECKING: MIN. 1%2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017.
5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS.
6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7I 10 (KD = 0:85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING
CODE 2017.
um onnc
�Vlvr < ZONES -
------ '
J
\\ \ RIDGE
---------
��///i/ ZONE \\\ \\ I
-------------------
Note: Dimension (a) is defined as 10% of the minimum width of the building or
40% of the mean height of the roof, whichever is smaller, however, (a) cannot be
a less than either 4e/d of the minimum width of the building or 3 feet.
TYPE 1 FASTENER PATTERN
ZONE 2 GABLE ROOF TaT
—J—-----------------�a
I I
I I
RIDGE
----- -------------- - -a
-------------------------+ a
ZONE 1—
I
-------------------- I
"ZONE 3 '-EAVE
FL# 11651.22 R3 •OCTOBER 5, 2017
At
Cont. Tape Seal for use on Slopes less than
#9-15 x 1.1/2' w/Sealer Washer @ 241 O.C. Max
Cont. Tape Seal for use on Slopes less than
#9-15 x 1.1/2' w/Sealer Washer @ 12' O.C. Max.