NOTICE OF ACCEPTANCE •(NOMN,:_qGy► r,tac aNn ni i nar,oner'n i 'miamiaade.aov/economy
Nichiha USA, Inc'
ARE SU AJEC:T •i 0 AW ,01RIECYIONsCONCFALED FASTENERS OR ATTACHMENT
I�EQUIREI) U�' :�fJ IPdw['EC1�Fi; `>•fluT
6465 E. Johns Crossing ARE THE RESPONSIBILITY OF THE
Johns Creek, GA 30097 MAY BE NUESSAU IPd ONCH TO CONTRACTOR OF RECORD
SCOPE: COMPLY WITH ALI. AJQTJ1J0A1I"10 d - 61
This NOA is being issued under the applicable, rules and regulations governing the use of construction
materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER
Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority
Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right
to have this product or material tested for quality assurance purposes. If this product or material fails to
perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may
immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER
reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control
Section that this product or material fails to meet the requirements.of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building
Code, including the High•Velaeity Huriicane Zone.
DESCRIPTION: NiehiProduetsTM Fiber -Cement Siccing
APPROVAL DOCUMENT: Drawing No. ITS N1090403, titled "NichiBoard & EcoPlank' , sheets 1 and 2
of 2 and Drawing.No. ITS N2090403( titled "NichiPanel", sheets I and 2 of 2, both dated 03/16/2069,
prepared by Nichiha USA, Inc, signed and sealed by Carl D. Fussner, P.E. on 07/10/2014, beating the Miami -
Dade County Product Control revision stamp with the Notice of Acceptance number and expiration date by
the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear,a permanent, label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade' County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been
no change in the applicable building code negatively affecting the performance of this product.
TERIVIINATION of this NOA will occur after the expiration date or if there has been a revision or change
in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of
any product, for sales, advertising or any other put -poses shall automatically terminate this NOA. Failure to
comply with any section of this NOA shall be cause for termination and removal of NOA.
ADvE,RTJSEMENT: The NOA number;preceded by the words Miami -Dade County, Florida, and followed
by the expiration date maybe displayed in advertising literature. If any portion of the NOA is displayed, then
it shall be done in its- entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its
distributors, and shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 09-0511.01 and consists of this page 1 and evidence pages E-I and E-
2, as well as approval document mentioned above.
The submitted documentation was reviewed by Carlos M. Utrera, P.E.
NOA No. 14-0715.03
l Expiration Date: July 22, 2019
Approval Date: January 29, 2015
d Vk g Page 1
1 dFe LZ; its
Nichiha USA, Inc.
I
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
I
A. DRAWINGS
1. Drawing No. ITS N1090403,1itled "NichiBoard & EcoPlank", sheets 1 and 2 of 2 and
Drawing No. ITS N2090403; titled "NichiPanel", sheets 1 and 2 of 2, both dated
03/16/2009, prepared by Nicl iha USA, Inc, signed and sealed by Carl D. Fussner, P.E.
on 07/101/2014. 1
B. TESTS "Submitted wider NOA # 09-0511.01
1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of NichiProducts Fiber -
Cement Panels, prepared by Intertek Testing Services NA LTD, Report No.
3145127COQ-004A, dated 08/07108, signed and sealed by Rick Curkeet, P.E.
2. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
2) Large Missile Impact Test per. FBC, TAS 201-94
3) Cyclic Wind Pressure Loading per FBC, TAS 203-94
along with marked -up drawings and installation diagram of NichiBoards and
EcoPlanks, prepared by Intertek Testing Services NA LTD, Report No.
3145127COQ-004B, dated 10/24/08, signed and sealed by Rick Curkeet, P.E.
3. Test report on Standard Specification for Flat Non -Asbestos Fiber -Cement Sheets of
NichiProducts Fiber -Cement Panels, per ASTM Cl 186-07, prepared by Intertek
Testing Services NA LTD, Report No. 3145123 COQ-005, dated 05/20/08, with a
revision dated 02/02/09; signed and sealed by Rick Curkeet, P.E.
4. Test report on Surface Burning Characteristics of NichiPanel Fiber -Cement Panels,
per ASTM E84-08, prepared by Inteitek Testing Services NA LTD, Report No.
3145123COQ-006,. dated 06/25/08, with a revision dated 04/03/09, signed and sealed
by Rick Curkeet, P.E.
5. Test report on Standard Test Method for Behavior of Materials in a Vertical Tube
Furnace at 750°C of Nichiha M series unprimed cernentitious; per ASTM E136-99,
prepared by Intertek Testing Services NA LTD, Report No. 3105885COQ-002, dated
10/26/06, with a revision dated 03/30/09, signed and sealed by Rick Curkeet, P.E.
• ,t�t�Z2i aptS
Carlos M. Utrera, P.E.
Product, Control Exaininer
NOA N6.14-0715.03
.Expiration Date: July 22, 2019
Approval Date: January 29, 2015
•E-1
Nichiha'USA, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
C. CALCULATIONS
1. Anchor calculations prepared by Progressive Engineering, Inc., dated
10/22/2014,,signed and sealed by Carl D. Fussner, P.E.
"Submitted under NOA # 09-0511.0I "
2. Anchor analyses prepared by Category 5 Engineering Services, Inc., dated
04/0312000, signed and sealed by Emma T. Mellinger, P.E.
D. QUALITY ASSURANCE
1. Miami -Dade Department of Regulatory and Economic Resources (RER)
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENTS
1. Drawing No. ITS N1090403 and ITS N2090403 statements of code conformance to
2610 FBC issued by Nichiha USA, Inc, dated 03/16/2009, signed and sealed by Carl
D. Fussner, P.E: on 07/10/2014.
2. Statement letter of no financial interest issued by Progressive Engineering, Inc., dated
07/10/2014, signed and sealed by Carl D. Fussner, P.E.
• OI�2� ilZofs
Carlos M. Utrera, P.E,
Product Control Examiner
NOA No.14-0715.03
Expiration Date: July 12, 2019
Approval Date: January 29, 2015
E -2
8" N
o/c Sp
(TY'
t
o/c S
(T;
12" Pai
0
1a
12" Panels Shown
51/4" Panels Shown
•
i1 . • •
. •
•
•.� •
•
■N
0.
��wwwww�w���■
1
o
nwwwww•vlw�u
������I�I/a��oww�s.+�o
w�so
nww�wso
I���I�I��/w•ww�wo
•�owww�
o ww���o
�*
n�-1-1
onoo
aw��•www�owww��o
������I�ia�o�cawow�o
11�1�1
�ow�w.o��n�n•�o
II�1�l
wwooawwwwrn��o
nwwww���uanoo�r�0000e
ur�c�a-u•wwww.t�
IOI�I
uwww��.'-'-'-1
Qw•ww�n�wwo
awooroa�n
!
�w�wle
1
cwwrwwci�o•.ww�owwww•urw�o�w�cw�-1-1-1
IMIMw•wo_wwwo•o�oow�o
srw�w�n�wC�o�o
��
o wwwwwcw�w�
IaIAI
o�
u wwwwwc�ww�
u r n
oww�o�
o
'mil®l®1
�a�ewwww•I�nww�l�e
,�.r.l..._I_I
ego-c�.�eae
o�wwww�
IOlOI^o
uwww�cw��u�>-wo
�I�lsliil•■�1
—OOnO00U
w�
�I�Ie1�1
•,�e���wo�www�nwwwwwn�e
w�oww�o��oo�o
o
o
o
o w�cr•w�
o ��
a iwww�[�•w�
I���I
g
o ww�o-�
o w�w•c�ww■
o.�+•w�
n wwwwr ��
n www�o�
e
c�srw�u�w•c�w�cwra�+�oww�t
ImlOI�
nv�W��1�Ir1�1�1
ww�•o��wo�o
l
I�Ir
�cw�w�
•w��ow�ewwww�nao�so
o •�:swl�
a rwwwwaww�
o ��
• .
•
. - ..
I���
u �on�n
•
11�1�1�1�1
�
www�•a�,1-1
�II�■Irll��1■f�■■1
�
o yes
i1�1�1�1�1
o wwvw�
o w•�s•�
n w�wo_�w
o
o
o
a w•wwt_
o ��
o �s
o w�ow�
e rw.v�
a wrs�•
-1
o �+�
r1-1
o ��
o
o wwww.�o�
n o+o
ww�s�
a �wo•�
DESCRIPTION and SPECIFICATION NichiBoard &
EcoPlank lap siding material is a non -asbestos fiber cement
product tested in accordance with ASTM C-1185 & ASTM
C-1186 Type A meeting the requirements of the 2010 Florida
Building Code (HVHZ). Planks are available in a variety of
widths within the maximum and minimum dimensions
specified below.
Plank Dimensions
Width
Length
Thickness
5 %4" Min.
12'
%s
12" Max.
'12'
is"
Design Pressure Rating -125 psf
LIMITATIONS.
All installation shall be done in accordance
- - - with this -Notice -of Acceptance, the
manufacturer's lnstallation reoomrriendations,---
and the applicable sections of the 2010
• o/c Spacing
Florida Building Code including High Velocity
Hurricane Zone where Required.
(Typ•)
2. Wood studs and plywood sheathing
supporting NichiBoard and EcoPlank siding
shall conform to the 2010 Florida Building
Code (including the HVHZ where required),
and the requirements of this Notice of
Acceptance (See Note Sheet 2).
544" Panel Height
3. Siding installed as specified herein shall be
classified as Large Missile Imp;,andM§Wjita'�ii
(TYP•)
e4 ODUCB Florida Q��': IDFUsi-If e
A0"V"l4ED p3q : No 71907 ;•
14" Overlap
(TYp.)
I nisei .1•radtwt CasualS '4 �• •�
�� STATE OF
0 Ft
ITS N10B0403 ft.
102 Ed NichiBoard & EcoPlank
0 Fiber Cement Siding
Vw-: Mach 1s.
NICHIHA USA, INC. JUL 1-0 2014
6465 E. Johns Crossing, Johns Creek. GA. 3M7
NICH160ARD & ECOPLANK SIDING INSTALLATION
The. planks shall be applied horrzontally commencing from the
bottom course of the wall.
• Each successive course shall overlap the prior course by 1 Y".
• Any- vertical joints shall be over framing members, with
�----- - �---�
fasteners either side of the joint..
• The planks shall be installed over %" APA rated exterior -grade
1
plywood. (SG = 0.50 min:) supported by 2" x 4" minimum wood
—NlchiSoard or EcoPlank Siding
studs spaced a maximum of 1 V D.C.
weather-Resisant Banter
. The: siding shall be fastened through -over -lapping planks with
ad x 2 Y" common Nan @
8d x 2 Yx" -long common: nails over wood studs.
5 %" o%vertically, Vo/c
V A'row of fasteners shall be placed in the overlap of each
Horizontally. Y4" Min.,
course, spaced 8" o/c in the horizontal direction.
2" Max. Edge Distance.
• Successive rows of fasteners shall be spaced not more than 5
o/c. (Planks greater than 6 $/" in width shall require an
Y8 Plywood Sheathing
additional row of fasteners in the center of the plank).
Fastened to Studs per2010
A distance of between %" and Z' from the edges shall always
Florida Building Code
be'observed.
PLYWOOD' SHEATHING--N_ OTE
Nichi6oard and EcoPlank Fiber -Cement Lap Siding is designed
NlchlBoard or EcoPlank Siding to be:installed.to plywood sheathing. Such plywood shall be %"
Weather-ResisantBarrier (5-ply) minimum, APA rated, sheathing, Structural 1 grade, with a
Bd x 2YeCommon Nail @ specified specific gravity of 0.50 or greater (e.g. Douglas
5 %" o/overficany, V oic
Horizontally. %" Min., Fir. -Larch or Southern Pine). Use of other grade plywood:shall
2" Max. Edge Distance. require a site -specific fastener design for the siding attachment,
signed and sealed ,by a Florida Registered Professional
Engineer:
%- Plywood Sheathing
Fastened to Studs per 2010
Florida Buildino Code
Such.plywocd sheathing shall be supported by framing
2" x Studs
@16"ok—
(TYP.)
6" Max.
o1c Spacing--
iryp•)
F-
6" Max.
o/c Spacing
(TYp•)
s� 48" Panel Width �48" Panel Width
—
x
...........
..
c
c
a
a
a
a
rcs
DESCRIPTION and SPECIFICATION
NichiPanel siding material is a non -asbestos
fiber cement product tested in accordance
With ASTM CA 185 & ASTM C-1186 Type A
meeting the requirements of the -2010
Florida Building Code (HVHZ). Panels are
available in four -foot widths within the
maximum and minimum dimensions
specified below.
Plank Dimensions
Width
Lencth
Thickness
48"
B'
is
48"
10,
vie
48"
12'
616"
Design Pressure Rating -104 psf
LIMITATIONS
1. All installation shall be done in accordance
with this Noticeof Acceptance, the
manufacturer's installation
recommendations; and -the -applicable_
sections ofthe2010 Florida Building Code
including High Velocity Hurricane Zone
where Required.
2. Wood studs and plywood. sheathing
supporting NichiPanel siding shall conform
to the 2010 Florida Building Code
(including the HVHZ where required), and
the requirements of this Notice of
Acceptance (See Note Sheet 2).
3. Siding installed as specified herein shall b`��111511iii1t8011
{classified as Large Missile Impact ��� O FUSS,
;.f
PItZ�l2lrYfSED ���` Q�`: ••••� 'S,
E N
0mroying Frith the
DO&nCO& No 71907
Aooe�tenoe No ! a7JSA�
ID DW
miiwhwe pYO&W Central : 0: STATE OF
�e S� r E���`�
NichiPanel NICHIHA USA, INC.
Fiber CementSiding 6465 E. Johns Crossing, Johns Crook, GA.30097
JUL 10 Z014
Q. 0 A :o
_.J
NICHIBOARD &.ECOPLANK SIDING INSTALLATION
• The planks,shall:be applied vertically, avoiding horizontal
joints.
• The planks shall be installed over %" APA.rated
exterior grade plywood (SG = 0.50 min.) supported by
2'W4' minimum'wood studs spaced a maximum of 16" o.c.
• Fasteners shall be placed at 6" o/c in the vertical direction
and 6"o/c.in the horizontal direction.
• A distance of between %a" and 3" from the edges shall
always 1%6 observed:
PLYWOOD. SHEATHING NOTE
NichiPanel Fiber-Cemenf:Siding is designed to be.installed:to
_plywood sheathing. Such plywood shall be 8" (5-ply) minimum,
APA rated sheathing; Structural-1-grade; with a=specified --- — — —
specific gravity of 0.50 or greater (e.g: Douglas Fir -Larch or
Southern Pine). Use of other grade plywood shall require a.
site -specific fastenerdesign for the siding.attachment, signed
and:sealed by a Florida. Registered Professional Engineer.
Such plywood sheathing "shall be supported by framing
.consisting of 2" x 4" minimum wood studs, ,or 2" x 611,18ga metal
studs, each at 16"'o/c. Plywood shall be attached to the framing
studs in, accordance with"the 2010 Florida Building Code (High
Velocity Hurricane Zone). Op11uuri'toe -
TRODUCFREVISSED ���` iD 1FU.
as ith wOWflor do �� Q.�.••'" :s41AWOMM= IN* �✓s
Qq -No 71.907'
.
Pmdice r'a�
�-:P . STATE QIF
--- 144lV[V .f
NichiPanel NICHIHA USA, INC. JUL 1 02014
Fiber Cement Siding *5�E. Johns Crossing. Johns Creok, G, WOW
Much as. zoos