Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLESCi I BCIS Home ( Log In { user Registration 1, Hot Topics i Submit Surcharge I Stats & Facts ; Publications 1 FBC Staff j BCIS Site Mal fid3 x � , RECEIVED r H Product c U rov i�\� :USER: PubllcUs T JAN 2 9 2018 Product Approval Menu > Product or Application Search > Apolication Lis; > Application Deta ST. Lucie County, Permitting 01,175 ° �caa 7 FL # FL. 106 4-R13 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Owens Corning Address/Phone/Email One Owens Corning. Parkway Toledo, OH 43659 (740) 404-7829 greg.keeler@owenscorning.com Authorized Signature Greg Keeler greg.keeler@owenscorning.com Technical Representative Mel 5ancrant Address/Phone/Email 1 Owens Corning PKWY Toledo, OH 43659 (419) 376-8360 mel.sancrant@owenscornig.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or i Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J.M. Nleminen Evaluation Report Florida Ucense PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 05/16/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence FL10674 R13 COI 2017 01 COI Nieminen.pdf Referenced Standard and Year (of Standard) Standard YM ASTM D3161 201 ASTM D3462 201 ASTM D7158 201 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Method 1 Option D 10/10/2017 10/11/2017 10/15/2017 12/12/2017 FL # I Model, Number or Name Description 10674.1 Owens Corning Asphalt Roofing 3-tab, 4-tab, 5-tab, laminated, starter and hip Shingles and Starters Limits of Use Approved for use in HVHZ: No, Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: N/A Other: Refer to ER, Section 5. installation Instructions FL10674 R13 II 2017 10 FINAL ER OC A' SHINGLES FL10674-R13.Ddf Verified By: Robert J. M. Nleminen PE - 5916, Created by Independent Third Party: Yes Evaluation Reports FL10674 R13 AE 2017 10 FINAL ER OC A SHINGLES F1_10674- 1R 3.Ddf Created by Independent Third Party: Yes Contact :: �2601 Blair Stone Road Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyrioht 2007-2013 State of Florida,:: Privacy Statement :: Accessibility Statement :: Rel Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, mail to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *PL 455.275(i), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an emai one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wi: address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee un please click tjgr. Product Approval Accepts: Li yt Card TRINITY I ERD EVALUATION REPORT Owens Corning One Owens Corning Parkway Toledo, OH 43659 (740) 404-7829 EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT #13 OXFORD, CT 06478 (203)262-9245 Evaluation Report 037940.02.12-118 FL10674-R13 Date of Issuance: 02/06/2012 Revision 8: 10/09/2017 SCOPE: This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code 'and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Owens Corning Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity IERD Evaluated" may be displayed In advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or Its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 10/09/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial Interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD Is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial Interest in any other entity Involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. qTRINITYltRD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: Owens Corning Asphalt Roof Shingles, as produced by Owens Corning, have demonstrated compliance with the following sections of the 6eh Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ; ASTM D7158 2011 3. REFERENCES: Entity Examination Reference Date UL LLC (CER9626) Physicals & Wind Resistance 1 File R2453, Vol. 3 02/15/2007 UL LLC (CER9626) Physicals & Wind Resistance 20120516-R2453 05/16/2012 UL LLC (TST9628) Physical Properties 06CA20263 04/18/2006 UL LLC (TST9628) Wind Resistance 11CA34308 02/18/2012 UL LLC (TST9628) Physicals & Wind Resistance 4786093137 02/01/2014 UL LLC (TST9628) Wind Resistance 4786126532 02/10/2014 UL LLC (TST9628) Physical Properties Classification letter 02/13/2014 UL LLC (TST9628) Physical Properties Classification letter 10/02/2015 Miami -Dade (CER3592) FBC HVHZ Compliance Various NOAs Various UL LLC (QUA9625) Quality Control Service Confirmation Exp. 05/16/2020 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Classic and Supreme" are fiberglass reinforced, 3-tab asphalt roof shingles. 4.1.2 Berkshire are fiberglass reinforced, 4-tab asphalt roof shingles. 4.1.3 Devonshire"" are fiberglass reinforced, 5-tab asphalt roof shingles. 4.1.4 Duration", TruDefinition* Duration, Duration" Premium Cool, TruDefinition" Duration* Designer Color Collection, TruDefinition"Oakridge, Oakridge and WeatherGuard* HP are fiberglass reinforced, laminated asphalt roof shingles. 4.2 Hip & Ridee Shingles: 4.2.1 Berkshire Hip & Ridge Shingles, High Ridge, WeatherGuard" HP Hip & Ridge Shingles, ProEdge Hip & Ridge Shingles and DuraRidgelm Hip & Ridge Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. 4.3 Accessory Starter Strips: 4.3.1 Starter Strip Shingle, Starter Strip Plus and Starter Shingle Roll are starter strips for asphalt roof shingles. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 Certificate of Authorization #9503 6TM EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 2 of 8 , " rTRINI Y I ER® 5.4 Wind Classification: 5.4.1 All Owens Corning asphalt shingles noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905,2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd = 150 mph ';(Vast = 194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 All Owens Corning hip & ridge shingles, Starter Strip Shingle and Starter Strip Plus noted herein are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (Vast =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D71SB applies to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.4.4 Refer to Owens Corning published information on wind resistance and installation limitations. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Underlayment: i 6.1.1 Underlayment shall be acceptable to Owens Corning and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3,1507.2.4 or R905.2.3. 6_2 6.2.1 6.2.2 6.2.4 6.2.5 Asphalt Shingles: Installation of asphalt shingles shall comply with the Owens Corning current published Instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Berkshire shingles require minimum five(S) nails per shingle. ➢ WeatherGuard HP shingles require minimum six (6) nails per shingle. ➢ Devonshire'" shingles require minimum six (6) nails per shingle. ➢ Starter Strip Shingle and Starter Strip Plus require minimum five (5) nails per strip. Refer to Owens Corning published information on wind resistance and installation limitations. Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.S. Staples are not permitted. Where the roof slope exceeds 21 units vertical'in 12 units horizontal, special methods of fastening are required. See figures below for details. Minimum Nailing — Starter Strip Shingle and Starter Strip Plus: Felturtcfarlaymetrt —Deck Self-adhoted WeatherLoW ' aederlayment Drip edge r' Nab located T-3"from eave instoll first Self. -Seat' adhesive Starter Stri positioned along eave shittgio tvittt 6" romovod Starter Strip sfiingle overhangs eaves and rakes %'Lrk' Exterior Research and Design, U.C. Evaluation Report 037940.02.12-RB Cert&ate OfAuthorizatfon N95d3 67H EDITION (2017) FBC NON-HVHZ EVALUATION FL30674-R13 Owens Coming Asphalt Roof Shingles Revision 8:10/09/2017 Page 3 of 8 6.2.6 Minimum Nailing — Classic®& Supreme: Normal Mansard or Area pers Wind 'Anae High Wind desvenas y' Arise pare vhrntos normarea Areas vlontoe faartoa S"Expcsun . E4irpoafa 6h Seabnt stop latlradr S@RaON 9 Yf'7. Standard Fastening Pattern °,T'RlNI''1Y'ERD Normal Mansard or Area pin Wlnd:Area* High Wind doov net.y. Ana Fore Wentos normaloa Ames v/ontw fu©rtrs ri 6xpgslalBtt Saaiant strip to*adese8adar ,'Liu 814" B +14" 1" r 6-Nail Fastening Pattern 58alant9h'ip tat7re de sdiadOr 1" 1. Asphalt rWingaeinent ' Cmralta da t6edoda'asla&o Mansard or Steep Slope Fastening Pattern Exterior Research and Design, I.I.C. Evaluation Report 037940.02.12-R8 CertificoteofAuthoriiotion#9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 4 of 8 6.2.8 Minimum Nailing — DevonshireT ", 7„ n 1 8" 8" 8° 7" +N q"vow S Rig' ex sure ExpoaWn de s 518 pulll Ubl aft del seflador Standard 6-Nall Fastening Pattern TRII�lI`Tl ERD 47 Nails Ten 1" Spots of As haft Root Cement Mansard or Steep Slope Fastening Pattern 6.2.9 Minimum Nailing — Durations, TruDefinition® Duration, Duration® Premium Cool & TruDefinition* Duration Designer Color Collection: 4.4011. Fastening Pottem Duienet�ta5tenutq m.a vA4et t" 12 12' P itta" ssi Nil $7ik w` Standard Fastening Pattern Fastenlnp for 641ail Fastoning Paorn 1" 12^ surr�raf�in0awxidm x�n.-rypxa+ 12, 1" ii,Yl."F�' •�N�N�,..i,..�`Y"• _ �43 �ijey�[+�pp: y9wt��.,:�"' rgt ro r,.g Smon410 tnlWnBXMWtft Roan emunt Mansard or Steep Slope Fastening Pattern 6-Nail Fastening Pattern Exterior Research and Design, U.C. Evaluation Report 037940.02.12-R8 Certfjlcate ofAothoriaatlon N9503 6TM EDITION (2017) FBC NON-HVH2 EVALUATION FL10674-R13 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 5 of 8 6.2.1 Minimum Nailing—TruDefinition Oakridge®, Oakridge®: 4Nit Pattern Eeque»lac6n4 claws Uff ogmre E0V00i6»ei0fi.S/Bpglg Standard Fastenina Pattern 111,�,8� '\ TRINITY ERD 6 Nall.13 ttern Fsoma on 6&vos yn r ;, Nails 6 6!8" Exposure 8618" 6tposu�e. 8lavbx ExposloYfa;ifdb6l8pulg kirpesfc�r+A6:&.S/8pu1e�. Mansard or Steep Slope Fastening Pattern 6.2.1 Minimum Nailing — WeatherGuard® HP: 6-Nail Fastening Pattern q. 1 ibuts >Rl'dt view OWN mind .., r.,. . y; lrr�eet!'I�aIISiWOYEs Eros aYs lr.ait.. .lrrirlw. Exterior Research and Design, LLC. Evaluation Report 037940.02.12-118 Certlflcate ofAuthoriaatlon g9503 6r" EDITION (2017) FBC NON.HVHZ EVALUATION FL10674-1113 Owens Coming Asphalt Roof Shingles Revision 8;10/09/2017 Page 6 of 8 I I I I t 6_3 Hip & Ridge Shingles: 6.3.1 installation of Berkshire Hip and Ridge Shingles, High Ridge, WeatherGuardo HP Hip and Ridge Shingles and ProEdge Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using four (4) nails per shingle. Installation of OuraRidgWm Hip & Ridge Shingles shall comply with the Owens Corning current published instructions, using two (2) nails per shingle. Refer to Owens' Corning published information on wind resistance and installation limitations, Including the use of hand -sealing for wind warranties. 6.3.2 Fasteners shall be in accordance with the manufacturer's published requirements, but not less than FBC 1S07.2.6 or R90S.2.S. Staples are not permitted. 6.3.3 Minimum Nailing — Berkshire® Hip-& Ridge and H(gh�Ridge: 6.3.4 Minimum Nailing — WeatherGuard® HP Hip and Fig. A; 4 PlagaCleD WIN A wid q q A � 1 I I• �. 1 A I. IF 11 A' Fig. 2 Ridge: Fig, C Hip:& Ridge Shingle-F901e11)ng. TQPVWI iq t lamr;� r.�n T' I 1n f" I $1 Etpo&U!0 I I Exterior Research and Design, LLC. Evaluation Report 037940.02.12-Rg CerrHicate of AuthorixaNan #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10674-1113 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 7 of 8 6.3.5 Minimum Nailing - ProEdge Hip & Ridge Shingles: YVf� d D 16an sedintsb* A,--' W ExpMnl _,, i `TRINI- ;ERA 'Standard Fastening pattern I1 7'1(3• Expo t 616 Minimum Nailing—DuraRidge" Hip & Ridge Shingles: Note: The drawings below pertain to minimum, as -tested attachment requirements. Refer to Owens Corning published installation instructions for their minimum requirements. P►dr,>iina Wind Oirxlial 'r Oiroalandomicenadumlc Dinaihf dct vivib prdOtnfmnto Its Sclan "xs�r7w.�`"" Ua01� O i I P 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table iS07.2.7.1 / R905.2.6.1. S. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for Information on which plants produce products covered by Florida Rule 9N-3 OA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC— QUA9625 ; (631) 546-2458; Kanchi.Agrawala-Dokania@ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report 037940.02.12-RS Certtjtcate of Authorkatton p9SO3 if" EDITION (2017) FBC NON-HVHZ EVALUATION FL10674-R33 Owens Corning Asphalt Roof Shingles Revision 8:10/09/2017 Page 9 of 8