HomeMy WebLinkAboutMEMORANDUMK#
Date:
To:
From:
Subject:
>. _'�,mussen Engineering LL(__
Engineering & Environmental Services
P.O. Box 1998, Okeechobee, FL. 34973-1998 Office: (863) 763-8546 Fax: (863) 467-8560
Memorandum
January 25, 2018
St. Lucie County Building Department
2300 Virginia Avenue
Ft. Pierce, FL. 3,4982-5652
Loris C. Asmussen, P.E.
John & Jean Dbmbkc
6755 SinsontelCt.
Ft. Pierce, FL, 34951
1995 MER HS
SCA13NN ED
RECEIVED
JAN 2 9 2018
ST. Lucie County, Permitting
Vehicle ID — 67780607, 67780608 & 67780609
This memorandum is provided to address re -roofing of a 1995 triple -wide (TW) mobile home.
Proposed is Gulf Rib Roof Paneling (26 GA metal — FL 11651.22R1) as a replacement for the
originally manufactured roof. Tamko Underlayment (30# ASTM D 226) will be used. Attached
are product approvals for the paneling (#11651.22R1) and underlayment (FL12328-R2), which
includes attachment methodology for the rib panels and underlayment. The panels are
manufactured by Gulf Coast Supply & Manufacturing, Inc. The Engineer Evaluator of the paneling
is Terrence E. Wolfe (FLJP.E. No. 44923) and the Validator is Locke Bowden (FL P.E. No.
49704).
Based on my review of this proposed project, including product approvals and loads for which the
above -referenced structure will be exposed to at this location in St. Lucie County (160 mph 3-
second gust and exposure "C"), the project is found to be in substantial compliance with the 2017
Florida Building Code.
i'
Any plywood, found toi be damaged or in disrepair, will be replaced and fastened in a manner
similar or equivalent to' that employed during manufacture of the original structure.
Sincerely,
Loris C. As"mussen, P.E.
Principle
C: Dombkowski (Ft. Pierce)