Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ROOFINGggg;ANWED COY 1=1 r"o," [[ BCIS Home Log In User Registration ! Hot Topic Submit Surcharge Stats & Facts Publications FBC Staff OCIS Site Map ; Links Search l idflda ...�_ rProduct Approval USER: Public User Product Aooroval Menu > Product or Application Search > Application Us t > Application Detail I Application Type I RevisionRl Code Version 2017 Application Status Approved RECEIVED Comments MAR 0 5 2018 Archived _. ST. Lucie County, Permitting Product Manufacturer Structall Building Syste . Address/Phone/Email 350 Burbank Rd. I Oldsmar, FL 34677 (813) 855-2627 info@structall.com Authorized Signature I Kenny Matuza info@structall.com Technical Representative Ken Clay Address/Phone/Email 350 Burbank Road Oldsmar, FL 34677-4906 (800) 969-3706 kclay@structall.com Quality Assurance Representative I Ken Clay Address/Phone/Email I 350 Burbank Road Oldsmar, FL 34677 (800)969-3706 kclay@structall.com Category jPrducofingSubcategory ts Introduced as a Result of New Technology Compliance Method I Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report Hardcopy Received Florida Engineer or Architect Name who developed the Do Kim Evaluation Report Florida License PE-49497 Quality Assurance Entity TI RADCO LLP dba RADCO A Twining Company Quality Assurance Contract Expiration Date 12/31/2022 Validated By CBUCK Engineering Validation Checklist - Hardcopy Received Certificate of Independence FL21443 R1 COI certificate of indgpendence_pdf Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 1708.2 Product Approval Method ; Method 2 Option B Date Submitted 09/28/2017 Date Validated 10/02/2017 Date Pending FBC Approval 10/08/2017 Date Approved - 1 12/12/2017 Summary of Products FL # Model, Number or Name Description 21443.1 Snap-N-Lock Composite Panel 3"x0.024"xllb EPS Composite Panel Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes FL21443 R1 II 2017 FBC Structall 3in-024-1LBS panel Installation DWG.pdf ,Impact Resistant: No Design Pressure: +88.69/-88.69 Verified By: PRI Construction Materials Technologies, LLC Created by Independent Third Party: Yes Other: In HVHZ, product shall be used in structures meeting the 'requirements of FBC Section 1626.1, unless impact protection is provided. See installation drawing for design Evaluation Reports FL21443 Rl AE Structall 024-030 Evaluation Report-2017 FBC.odf .pressures and spans. Created by Independent Third Party: Yes 21443.2 Snap-N-Lock Composite Panel 3"0.030"xilb EPS Composite Panel Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL21443_Ri II 2017_FBC•.Structall_3in,-_ in-j BS�anel Approved for use outside HVHZ: Yes Installation DWGpdf Impact Resistant: No Verified By: PRI Construction Materials Technologies, LLC Design Pressure: +88.69/-88.69 Created by Independent Third Party: Yes Other: In HVHZ, product shall be used in structures meeting Evaluation Reports the requirements of FBC,Section 1626.1, unless impact FL21443_._R1_AE Structall._024=030_Evaluation Report 2017 protection is provided. See installation drawing for design FBC.pdt pressures and spans. Created by Independent Third Party: Yes Back FE Contact Us :: 2601 Blair Stone Road. Tallahassee Fl, 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records. request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275 i (1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: L 0 ..............._...................... _._._..._........... ........._.. Credit Card Safe STRUCTALL BUILDING SYSTEMS PANEL SPAN TABLES: 3" x 0,024 x 1 - LB EPS PANELS (OPEN STRUCTURES -EXPOSURE B) 3° x 0.024 x 1 - LB EPS PANELS (OPEN STRUCTURES -EXPOSURE C) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALL WA LE SPAN (FT) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/60 t Lao/I2 L/180 L/240 L/60 t L/a0 L/180 L/240 110 23.03 17.22 15.68 13.36 11.64 110 27.96 15.63 12.20 10.47 120 27.41 15.73 14.63 12.32 10.59 120 33.28 14.05 q12.5O 11.15 9.43 130 32.16 14.34 13.67 11.36 9.63 130 39.06 12.73 10.19 8.47 140 37:30 13.09 1 10.47 8.74 140 45.30 11.62 9.30 7.58 1 0 42.82 12.03 11.9 9.64 7.92 150 52.00 10.68 8.48 6.75 48.72 11.11 11.18 8.87 7.14 160 59.16 9.86 10.01 7.70 5.98 180 61.66 10.15 5.76 7.46 5.73 180 74.88 9.16 8.60 6.29 4.57 ' MULTIPLY ULTIMATE LOADS BY 0.6 FOR ALLOWABLE LOADS 3" x 0,024 x 1 - LB EPS PANELS (ENCLOSED STRUCTURES -EXPOSURE B) 3" x 0,024 x 1 - LB EPS PANELS (ENCLOSED STRUCTURES -EXPOSURE C) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) WIND SPEED NET ULTIMATE LOAD (PSF)' MAX. ALLOWABLE SPAN (FT) L/60 6 Lao L/120 L/180 L/240 L/60 t Lre0 L/120 L/180 L/240 110 18.62 18.98 16.96 14.64 12.92 110 22.53 17.87 15.82 13.50 11.78 120 22.25 17.46 15.90 13.58 11.86 120 26.91 16.01 14.74 12.43 10.70 130 25.99 16.35 14.95 12.63 10.91 130 31.54 14.53 13.80 11.48 9.76 140 30.23 14.91 14.05 11.74 10.01 140 36.52 13.27 12.91 10.60 8.87 150 34.61 13.71 13.23 10.92 9.19 150 41.93 12.19 12.08 9.77 8.05 160 39.43 12.66 12.45 10.14 8.42 160 1 47.69 11.26 11.30 8.99 7.27 180 49.99 11.22 1 11.03 1 8.72 7.00 180 1 60.38 10.25 1 9.89 7.58 5.86 ' MULTIPLY ULTIMATE LOADS BY 0.6 FOR ALLOWABLE LOADS 3" x 0,024 x 1 - LB-EPS-PANELS- - (PARTIALLY ENCLOSED STRUCTURES) (EXPOSURE B) - -- 3'- x-Or024--x- 1-----LB-EPS -PANELS- _ (PARTIALLY ENCLOSED STRUCTURES) (EXPOSURE C) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) WIND SPEED NET ULTIMATE LOAD (PSF)1 MAX. ALLOWABLE SPAN (FT) L/60 t vea L/120 L/180 L/240 v6o t Lreo L/120 L/180 L/240 110 27.28 15.87 14.66 12.35 10.62 110 33.12 14.09 13.49 11.18 9.46 120 32.46 14.26 13.62 11.30 9.58 120 39.42 12.66 12.45 10.14 8.41 130 38.10 12.93 12.65 10.34 8.62 130 46.26 11.47 11.49 9.18 7.45 140 44.18 11.80 11.76 9.45 7.73 140 53.65 10.47 10.60 8.29 6.56 150 50.72 10.84 10.93 8.63 6.90 150 61.59 9,62 9.77 7.46 5.74 160 57.71 10.01 10.16 7.85 6.13 160 70.09 -8.89 8.99 6.69 4.96 180 73.04 9.29 8.74 6.44 4.71 180 88.69 8.31 7.58 5.28 3.55 MULTIPLY ULTIMATE LOADS BY 0.6 FOR ALLOWABLE LOADS PRODUCT APPROVAL DETAILS: • BLDG CODE: 6TH EDITION FLORIDA BUILDING CODE (2017 FBC) D ❑ K 1 M & ASSOCIATES, LLC • LIMITS OF USE: FOR PATIO USE ONLY (RISK CATEGORY 1). CONSULTING -CARPORTS -PATIO COVERS STRUCTURAL -SUNROOMS ENGINEERS -SCREEN ENCLOSURES -CANOPIES ' -OTHER SIMILAR MINOR STRUCTURES BOX 10039 - Tampa, FL 33679 Tel: (813) 857-9955 Note Rev./Dal Description 1. All product performance specifications and construction requirements shall be engineered by a 0 - 2017 I ISSUED FOR PRODUCT APPROVAL licensed design professional in accordance with the Aluminum Design Manual, Specifications & Guidelines for Aluminum Structures, Washington, DC, for wind resistance in conformance to FBC 0 Chapter 16 for Components and Cladding Loads, ASCE 7-10 Chapter 30 for Roof Components and 0 Cladding for Enclosed and Open Structures. Effective area for wind load calculations based on 50 sq. feet (absolute value of controlling design wind pressure is shown on span tables). 2. Span schedule show maximum roof panel spans between two sided clear supports as shown. 3. Wind load design pressures in span tables are calculated in accordance to ASCE 7-10, Components Q & Cladding loads as required in FBC Table'2002.4. Mean roof height of structure shall not exceed 15 feet above grade. Span tables for open structures based on 7.5° max. roof slope and used the avg. of free flow and obstructed flow net pressure coefficients. Span tables for enclosed and partially enclosed structures based on 27P max. and 7' roof slope, respectively. j 4. Each roof panel shall be connected per design professional's instructions, but may use min. per 0 w of details shown on this dwg. at each support (or other approved connection by design professional) rn of Z nn- OU wl min. 0.040" thick, 6063-T6 aluminum base metal. Edge panels shall be supported on min. three E a- sides or per design professional's instructions. Details 1 & 2 are reflective of the boundary ; M r- 2 Y U conditions utilized in the testing of panels as referenced in the test reports. U) W QO 7p 5. Composite panels shall be constructed using type 3105-H 154 aluminum facings, I or 2 PCF ASTM rn Y J U_ j 0 C-578 Imperial Foam & Insulation Manufacturing brand EPS adhered to aluminum facings with -0 m D- n- z a- Morad M640 Series adhesive (by Rohm and Haas Company). Fabrication to be by Structall panel 0 products only in accordance with approved fabrication methods. CO m E [a j - 0 U) -tic 6. S c-tall roof panels maintain a UL 1715 (int) class'B' (ext) rating -and are NER-501 approved. 2 ram)- p N ~ 2 7. This specification has been designed and shall be fabricated in accordance with the requirements of _ CD rn F the Florida Building Code 6th Edition (2017 FBC), composite panels comply with Chapter 7 rn 6 a Q Section 720, Chapter 8 Section 803, Class A interior finish, and Chapter 26 Section 2603. All local °7 2 o OR building code amendments shall be adhered to as required. O O 8. The designer shall determine by accepted engineering practice the design loads for site specific load _j conditions (including load combinations) using the data from the loads tables and spans in this approval. DRAWN BY: DYK 9. Deflection limits and allowable spans have been listed to meet FBC including the HVHZ. In HVHZ, CHECKED BY: DYK this product shall be used in structures meeting the requirements of Section 1626.1, unless impact SCALE: AS SHOWN DATE: 10/19/16 resistance in accordance to the HVHZ requirements are met. 10. Safety factor of 2.0 has been use to develop allowable loads and spans from testing in accordance to the Guidelines for Aluminum Structures Part 1 and conforms to the FBC Chapter 16 and 20. 11. Testing has been conducted in accordance to ASTM E72-05: Strength Test of Panels for Building 0. �1GENgF Construction. - DO YEON KIM, P.E. 12. Linear interpolation shall be allowed for figures within the tables shown. = FLA. REG. NUMBER 494V -e - 13. Panels with fan beams shall be considered equivalent to similar panels without fan beams. Design 4U professionals may include the strength of the fan beam to exceed shown figures as part of = DO KIM &4$,SOCIATES;L4C- c . `CAR 26¢b7 Z; site -specific engineering. CcSStif30X>r003FL ` 14. Reference test reports: Certified test reports STRL-002-03-01, STRL-002-03-02, STRL-004-03-01 L by PRI-Construction Materials Technologies LLC. Tnis"emn.abee dea.oni anydyPedane emdbyDPY. gm.PEonthistla usinga0i0i1al 5ig.Pdlmeo ds •1lhis daumen[ the signaNee mu ed and re consideredgn,d vgned and seaId b"_fiedonanyelecvonic Pies. Drawing No.-161027 SHEET 1OF2 #10x4' S.M.S. W/ 1);'O FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. 3' COMPOSITE ROOF PANELS r. me n10 • •al I M1, e HEADER/EAVE RAIL MIN. 3x2xO.O45 DETAIL 2 SEAL JOINT WITH CONTINUOUS CAULKING )UUUU UUUUUc 0000 J'C 00000 � Za )OOOOOOOOOOC �A DETAIL 1 BOTTOM FACINGS INTERLOCKING CROSS SECTION DETAIL 2 w SLOPE 4' MAX WIDTH INTERLOCKING / PANEL (1/4'/FT MIN SLOPE) v v 000 Q� �I \ 00000000 za O O O O O ¢ W EPS CORE 1LB O O O O O O O\-o0000 F� O O (n (L a 0000000 r 0 \ ALUMINUM BOTTOM = I FACINGS [TD.H.—� f�—CLEAR SPAN (L) INSIDE TO INSIDE ENGINEER OF RECORD TO PROVIDE 14' FLASHING (CONT.) TUCK UNDER SHINGLED D ❑ K I M @ LEAST 6' & ASSOCIATES, LLC- SEALANT 344' MAX. CONSULTING STRUCTURAL p14xYt' SMS W/ INTEGRAL %'0 EXTRUDED OR BRAKE -FORMED ROOF HEADER ENGINEERS WASHER AND NEOPRENE GASKET OR RECEIVING CHANNEL (0.044' MIN. THICKNESS) @ 12' D.C. TOP & BOTTOM. WITH MIN. IY4' BEARING LEG. (1) WO x 2' LAG SCREW-@ 24' D.C. PO BOX 10039 ENTIRE LENGTH OF RECEPANG CHANNEL Tampa, FL 33679 v- 0 0 0 O SECURE FASCIA TO EACH RAFTER TAIL TeC(813)857-9955 0 0 00 0 0 0 O V/ (1) WOW 4' LONG PAN HEAD LAG SCREWS 0 0 0 0 0 0 0 BEFORE ATTACHING RECEIVING CHANNEL RevJDat Description p — ]a1] ISSUED FOR PRODUCT APPROVAL OPTIONAL GUTTER OR DRIP CAP ALL ROOF CONNECTIONS & ADD THICKNESS OF 36' MAX IN FRONT & 25% SUPPORTING STRUCTURE DETAILS WALL FOR TOTAL OF PANEL WIDTH @ SIDES IN ADDITION TO AND IN -LIEU OF PANEL SPAN: (12' MAX AT SIDES) DETAILS SHOWN. _ 3" EPS ROOF PANEL! SPAN DESCRIPTION SOFFIT (❑R) SLOPE O O O O O 0000006000 0 0 0 0 0 H14xX- S.M.S. W/INTEGRAL 3,'0 WASHER AND NEOPRENE GASKET@ 12' O.C., TOP & BOTTOM. IF CLEARANCE PROHIBITS INSTALLATION OF TOP FASTENERS USE k14x4' S.M.S. V/IYi 0 FENDER WASHER AND NEOPRENE GASKET @ 12' O.C. DETAIL 1 SOFFIT Y.' 0 x 2$' LONG WOOD LAG SCREV OR Y4' 0 x 2Y•' LONG MASONRY ANCHORS ' _ @ 24' D.C. MAX.. -- - oI _ Q ?' HOST STRUCTURE --1 (MASONRY OR WOOD) J O W W �zo2 E%TRUDED UR BRAKE -FORMED ROOF HEADER ' - - OR RECEIVING CHANNEL (0.044' MIN. THICKNESS) m d Q WITH MIN.' Ila- BEARING LEG. >.O �0 p �CJ 0O U)7ir to LL IL Z d _ ` W 5� W DoDo E DoJ to l-NO X W W 2"O o in o CL OO UL DRAWN BY: DYK CHECKED BY: DYK SCALE: AS SHOWN DATE 10119116 �O DO YEON KIM. P.E. w FLA, REG. f4UMBER 49497 w: ADO KIM &ASSOCIATES?f1C-i This item has be n elec68hically signedand sealed by Do Y. Kim. PE in this date using a Digital Signature. Prince I copies of this document are not considered sign and sealed and the signature must be verified in any electronic copies. 2017.09.28123 0-04'00' Drawing No.-161027 SHEET 2 OF •