Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL SINGLE HUNGFlorida Building Code Online r Page 1 of 2 A.. � o- \. . , DBAR�NONF�-A6pU7i. D�pRp k����Yl'�k916}'r�q• R6R�!'ACT'DBAFk BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search dbor _Product Approval �y �� � � USER: Public User P.P .ia` aW n re,tfw Product Approval Menu > Product or Applkatlon Search > Application Lisb> Application Detail FL # FL11479-R4 Application Type Revision Code Version 2017 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. Comments Archived ❑ Product Manufacturer Regency Plus Incorporated Address/Phone/Email 2000 Locust Gap Highway Mount Carmel, PA 17851 (570)339-3374 tonyq@conservationwindows.com I Authorized Signature I Tony Procopio tonyp@conservationwindows.com i Technical Representative Tony Procopio Address/Phone/Email 2000 Locust Gap Hwy Mount Carmel, PA 17851 (570)339-3374 tony@cwbyrpi.com Quality Assurance Representative Joe Korzeniecki Address/Phone/Email 2000 Locust Gap Hwy. Mount Carmel, PA 17851 (570)339-3374 joek@window-pros. info Category Windows Subcategory Mullions Compliance Method Certification Mark or Listing Certification Agency National Accreditation & Management Institute Validated By National Accreditation & Management Institute Referenced Standard and Year (of Standard) Standard Year AAMA 450 2010 AAMA/WDMA/CSA 101/I.S.2/A440 2005 ASTM E1886 2005 ASTM E1996 2002 TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Florida Licensed Professional Engineer or Architect FL11479 R4 Equiv EERNo2522 RevO FL11479 Mullions ss.odf https: //www. floridabuilding. org/pr/pr_app_dti. aspx?param=wGE VXQwtDgv8JygqZ9 Wu... 4/25/2018 Florida Building Code Onlir, o Page 2 of 2 N Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option A 01/06/2018 01/10/2018 01/17/2018 FL # Model, Number or Name Description 11479.1 TECH 5000 IMPACT MULLION TECH 5000 IMPACT MULLION Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11479 R4 C CAC NIO07051-R4.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 12/31/2020 Design Pressure: +70/-70 Installation Instructions Other: FL11479 R4 II RPLS0057 RevA SERIES-5000- MULLIONS ss.Ddf Verified By: Robert J. Amoruso, P.E. FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL11479 R4 AE PERNo2522 RevO FL11479 Mullions ss odf Created by Independent Third Party: Yes 11479.2 TECH 5000 T IMPACT MULLION TECH 5000 T IMPACT MULLION Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL11479 R4 C CAC NI007050-R3.Ddf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/28/2021 Design Pressure: +70/-70 Installation Instructions Other: FL11479 R4 II RPLS0058 RevA SERIES-5000-T- MULLIONS ss.odf Verified By: Robert J. Amoruso, P.E. FL PE No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL11479 R4 AE PERNo2522 RevO FL11479 Mullions ss.odf Created by Independent Third Party: Yes Back Nezt Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click he[fl.. Product Approval Accepts: Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgv8JygqZ9 Wu... 4/25/2018 REGENCY PLUS, INC. SERIES TECH 5000 IMPACT MULLION SYSTEM INSTALLATION MULLION ANCHORAGE DETAILS NOTES: 1. THE PRODUCT SHOWN HAS BEEN TESTED, EVALUATED AND DESIGNED TO COMPLY WITH REQUIREMENTS OF THE CURRENT EDITION OF THE FLORIDA BUILDING CODE INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ). 2. THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON THE FOLLOWING SIGNED AND SEALED TEST REPORTS AND ASSOCIATED LABORATORY DRAWINGS BY NATIONAL CERTIFIED TESTING LABORATORIES, YORK, PA. 2.1. NCTL-110-10616-1, AAMA/WDMA/CSA 101/I.S.2/A440 2.2. NCTL-110-10616-2, TAS 201, TAS 202 AND TAS 203 2.3. NCTL-110-10616-3, ASTM E1886 & ASTM E1996 3. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 4. INSTALLER/CONTRACTOR IS RESPONSIBLE FOR MAINTAINING STRUCTURAL INTEGRITY OF WINDOW OPENING AND ALL WOOD FRAMING AROUND WINDOW. 5. RESPONSIBILITY OF SELECTING FENESTRATION PRODUCTS TO MEET ANY APPLICABLE LOCAL LAWS, BUILDING CODES, ORDINANCES OR OTHER SAFETY REQUIREMENTS REST SOLELY WITH THE ARCHITECT, ENGINEER OF RECORD, BUILDING OWNER OR CONTRACTOR. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS INCLUDING THE HIGH VELOCITY HURRICANE ZONE. 6. DESIGN PRESSURE AND INSTALLATION DETAILS SHOWN IN THIS DOCUMENT APPLY ONLY TO THE MULLION. WINDOWS MUST BE APPROVED UNDER SEPARATE PRODUCT APPROVAL. 7. SINGLE UNITS TO BE MULLED ARE NOT LIMITED TO THOSE SHOWN IN THIS DRAWING. SINGLE UNITS TO BE MULLED TOGETHER MUST BE MANUFACTURED BY REGENCY PLUS, INC. AND MUST BE MADE OF VINYL PVC. FIXED WINDOW SHOWN; OTHER WINDOW TYPES APPROVED. 8. DESIGN PRESSURE OF MULLED UNIT SHALL BE CONTROLLED BY THE LESSER DESIGN PRESSURE OF THE MULLION OR THE INDIVIDUAL WINDOW UNIT. 9. TWIN CONFIGURATION SHOWN. UNITS MAY BE MULLED TOGETHER INDEFINITELY IF THE SINGLE UNIT WIDTH AND THE SINGLE UNIT HEIGHT ARE NOT EXCEEDED, AND MULLION IS ANCHORED AS SHOWN IN THIS INSTALLATION DRAWING. 10. MULLION VERTICAL INSTALLATION SHOWN. MULLION MAYBE USED IN HORIZONTAL APPLICATIONS IF DIMENSIONS SHOWN ARE NOT EXCEEDED AND MULLION IS ANCHORED ACCORDING TO THIS INSTALLATION INSTRUCTION. PERFORMANCE RATING MAXIMUM WINDOW DESIGN UNIT SIZE MULLION ORIENTATION PRESSURE IMPACT RATING (SEE GENERAL NOTE 5) (PSF) 53" X 72" VERTICAL (SHOWN) +/70 LARGE MISSILE IMPACT; HVHZ WIND ZONE 4, MISSILE LEVEL D; NON-HVHZ 72" X 53" HORIZONTAL (NOTE 10) 77" MAX. UNIT HEIGHT 53" MAX. FRAME WIDTH r -�— DETAIL A 1 n n 6 1/2" MAX. C C 8" MAX. O.C. Illy i INSTALLATION ANCHOR DETAIL B 8 EACH (TYP.) SERIES TECH 5000 IMPACT MULLION SEE NOTES 7 & 10 FOR APPROVED CONFIGURATIONS EXTERIOR ELEVATION (SEE INSTALLATION NOTE 3 ON SHEET 2) TABLE OF CONTENTS SHEET SHEET DESCRIPTION 1 ELEVATION AND GENERAL NOTES 2 CROSS SECTIONS, BOM AND INSTALLATION DETAILS 3 COMPONENTS : t-: z Robed J. Amoroso, P.E. Florida P.E. No. 49752 -poO�Yi�. GENew�.yGb 4nsx ' me �O��RTe EO ',��F�S�ONl1LE, 2 Digitally signed by Robert J Amoruso _ Date: 2018.01.09 10:17:48-05'00' 8 R SR PARTS LIST NO. PART NUMBER DESCRIPTION 1 A118-02PO78 4" ALUMINUM MULLION 2 A116-02MO78 MULLION CONNECTOR (CLIP) 3 MULLION CAP SECTION C-C FIXED WINDOW FRAME SHOWN FOR REFERENCE (SEE GENERAL NOTE 7 ON SHEET 1) CONCRETE/MASONRY BY OTHERS (SEE NOTE 5) 2-1/4" MIN. v° EDGE a. ° °• DISTANCE 44. v E8 SMS SELF —TAPPING 3/16" ITW _ ;CREW (SEE INSTALLATION TAPCON 1-1/2" MIN. JOTE 3) EMB. 2 11X BUCK 1 BY OTHERS (OPTIONAL) INSTALLATION NOTES: 1. FOR ANCHORING INTO CONCRETE OR MASONRY USE FOUR (4) 3/16" ITW TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1-1/2" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2-1/4" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATION DETAILS. USE CLIP'S DIAGONAL HOLES TO INSTALL TAPCONS. 2. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE EIGHT (8) #8 WOOD SCREW WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATION DETAILS. 3. FOR ATTACHING WINDOW UNITS TO MULLION USE MINIMUM #8 SMS SELF -TAPPING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A MINIMUM EMBEDMENT OF THREE THREADS PAST MULLION WALL. LOCATE SCREWS AS SHOWN IN ANCHOR ELEVATION ON SHEET 1 AS MINIMUM. 3.1. SEE NOTE 4 FOR ADDITIONAL REQUIREMENTS. 4. FOR WINDOW UNITS ANCHORING SCHEDULE REFER TO WINDOW APPROVED INSTALLATION INSTRUCTIONS. 4.1. IF WINDOW APPROVED INSTALLATION INSTRUCTIONS REQUIRE SCREWS GREATER IN DIAMETER/SIZE THAN #8 OR ANCHOR SPACING SMALLER THAN THAT SHOWN IN SHEET 1 ELEVATION, APPROVED INSTALLATION INSTRUCTIONS SHALL GOVERN OVER NOTE 3 REQUIREMENTS. 5. FOR VERTICAL MULLION INSTALLATIONS, HEAD AND SILL SUBSTRATES WILL GENERALLY BE CONCRETE HEADER OR FOOTERS/PRE-CAST SILLS, ETC. FOR HORIZONTAL MULLION INSTALLATIONS, JAMB SUBSTRATES CAN BE EITHER CONCRETE OR MASONRY (CMU). 3/16" 1- TAPC( DETAIL A WOOD FRAMING TOP CLIP INSTALLATION (SEE NOTE 2, SHEET 2) #8 WOOD SCREW #8 WOOD SCREW 1-1/2" MIN. EMB. L-EIVNIV. EDGE DISTANCE CONCRETE/MASONRY BY OTHERS (SEE NOTE 5) DETAIL B WOOD FRAMING TOP CLIP INSTALLATION (SEE NOTE 2, SHEET 2) \—SHEATHING BY OTHERS DETAIL B CONCRETE/MASONRY FRAMING TOP CLIP INSTALLATION (SEE NOTE 1, SHEET 2) SHEATHING BY OTHERS -WOOD FRAMING BY OTHERS DETAIL A CONCRETEIMASONRY FRAMING TOP CLIP INSTALLATION (SEE NOTE 1, SHEET 2) 5/ D MIN. EDGE DISTANCE 1-3/8" MIN. EMB. 1-3/8" MIN. EMB. WOOD FRAMING BY OTHERS RobertJ. Ammuso, P.E. Florida P.E. No. 49762 aW>w u\c.�1yy,.2, _a ST JI- ?9: Bin E 0 ��F81[OR\Q?p Digitally, signed, by RobertjJ Amoraso Date:2018.01.09 I,,' 1'0::UM-05'00' co m o Co a 0 r; v U " n W w rc 7 IX h IX F I' L, ad a 09 � U2o��p �J cn Ofaa�z Q J aZ Y H W �Q W C7 0 m Ko2 UZ o H� a F-. wW �N LnN w U 1' 2 3/4" 4LU 3/4" O,� 4" MULLION ALUMINUM 6063-T6 6.. 1/2" 1 1/4" 1/2" 1 3/4" 2 3/4" 1/2" 1 /8� O MULLION CONNECTOR (CLIP ALUMINUM 6063-T6 0 1/4" THRU CSK 03/8"X82' U) y 2 i Q 2 U 1" � 6 = m � �0 2:cn ..Q F Q �aa¢Lu a w Ep Zj2o� pgg U' pUrn0U Sig OMULLION CLIP W om u 3 0 VINYL PVC 0.065" THICK- W ,W Robert J. Amoruso. P.E. Florida P.E. No. 49752 '�gg)ON11lEpr�``` Digitally signed by Robert J Amoruso= . Date:2018.01.09 10:18:17-05'00' Product Evaluation Report Rule 61 G20-3 F.A.C. I Report No. 2522 1 Project No. 417-0906 1 1/4/18 1 Page 1 of 2 Product Manufacturer Regency Plus Incorporated 2000 Locust Gap Highway Mount Carmel, PA 17851 Florida Product Approval No.: FL11479 Product Name, Model and/or Description Series Tech 5000 Impact Mullion Series Tech 5000 T Impact Mullion Code: Current Edition of the Florida Building Code Compliance Method: Product Approval Rule 61G20-3.005(1)(a) — Certification Mark or Listing Product Name, Model and/or Designation; Test Report No.; and Installation Drawing No.: • Series Tech 5000 Impact Mullion o Test reports and associated laboratory drawings by National Certified Testing Laboratories, York, PA signed and sealed by Robert H. Zeiders, P.E. ■ NCTL-110-10616-1, AAMA/WDMA/CSA 101/I.S.2/A440-05 ■ NCTL-110-10616-2, TAS 201-94, TAS 202-94 AND TAS 203-94 ■ NCTL-110-10616-3, ASTM E1886-05 & ASTM E1996-04 o PTC Product Design Group Drawing No. RPLS0057, Rev. A, dated 1/4/18, signed and sealed by Robert J. Amoruso, P.E., FL License Number 49752 Series Tech 5000 Impact T Mullion o Test reports and associated laboratory drawings by National Certified Testing Laboratories, York, PA signed and sealed by Robert H. Zeiders, P.E. ■ NCTL-110-10617-1, ASTM E1886-05 & ASTM E1996-04 ■ NCTL-110-10617-2, AAMA 450-00 ■ NCTL-110-10617-3, TAS 201-94, TAS 202-94 AND TAS 203-94 o PTC Product Design Group Drawing No. RPLS0058, Rev. A, dated 1/4/18, signed and sealed by Robert J. Amoruso, P.E., FL License Number 49752 Engineering Analysis Ft Evaluation: • Anchorage engineering in accordance with the current edition of the Florida Building Code for Series Tech 5000 Impact Mullion and Tech 5000 Impact T Mullion signed and sealed by Robert J. Amoruso, P.E., FL License Number 49752. Performance Testing: Performance Standards used in testing, NON-HVHZ locations: o AAMA 450-00 o AAMA/WDMA/CSA 101/I.S.2/A440-05 o ASTM E1886-05 o ASTM E1996-04 Performance Standards used in testing, HVHZ and Non-HVHZ locations: o TAS 201-1994 o TAS 202-1994 o TAS 203-1994 Limitations It Conditions of Use: This product has been evaluated for use inside the High Velocity Hurricane Zone (HVHZ). • Refer to Product Installation Instructions noted above for: o Maximum allowable wind loads at related maximum allowable size(s). PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 r�L 321-690-1788 1 FBPE Certification of Authorization No. 25935 Product Evaluation Report Rule 61 G20-3 F.A.I . I Report No. 2522 1 Project No. 417-0906 1 1 /4/18 1 Page 2 of 2 o Overall dimensions and material/grade of main product components, accessories, etc. o Illustrated diagrams of the attachment of the product to substrate structure. o Anchor type(s); size(s), substrate(s), embedment, edge distance, and spacing/locations. Site wind pressures shall be determined by a licensed professional engineer in accordance with the current edition of the Florida Building Code and/or ASCE 7-10 for components and cladding based on allowable stress design. Site conditions not covered in this product evaluation document are subject to additional engineering analysis by a licensed professional engineer or registered architect as required by the authority having jurisdiction. Adequacy of the existing structural substrates as a main wind force resisting system capable of withstanding and transferring applied product loads to the foundation is the responsibility of the licensed professional engineer or registered architect acting as the design professional of record for the project of installation. Certificate of Independence per Product Approval Rule 61 G20-3.009 PTC Product Design Group, LLC and Robert J. Amoruso, P.E. does not have, nor will acquire, any financial interest in the company manufacturing or distributing product(s) covered by this Product Evaluation Report. PTC Product Design Group, LLC and Robert J. Amoruso, P.E. do not have, nor will acquire any financial interest in any other entity involved in the approval process or testing of the product(s) covered by this Product Evaluation Report. Digitally signed ell "G E iv F �9 ro,� by Robert J N 49752 =0= Amoruso Date: �� SYF► E OF �:�k/ 0NA 10:19:38-05'00' Evaluated By: Robert J. Amoruso, P.E. FL P.E. License Number 49752 AAA PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775 r/L, 321-690-1788 1 FBPE Certification of Authorization No. 25935 i NOTICE OF PRODUCT CERTIFICATION CERTIFICATION NO: DATE: CERTIFICATION PROGRAM: COMPANY: CODE: REVISION DATE: NI007051-R4 03/28/2007 Structural Regency 750-1 02/02/2015 To verify that the "Notice of Product Certification" is valid, please visit www.NAINiICertification.com to assure that the product is active and currently listed. This certification represents product conformity to the applicable specification and that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim certification status. Please review and advise NAMI if any corrections are required to this document. COMPANY NAME AND ADDRESS PRODUCT DESCRIPTION Regency Plus, Inc. Series "Tech 5000 Impact Mullion" 2000 Locust Gap Highway Fixed Lite Combination Window Mount Carmel, PA 17851 Configuration: 0/0 Glazing: IG-Interior-3/16" Annealed Glass/ Exterior -Laminate 5/32" Annealed Glass/0.090" SGP/ 5/32" Annealed Glass Frame: W-2720mm(107") H-1955mm(77") Lite: W-1345mm(53") H-1955mm(77) SPECIFICATION PRODUCT RATING AAMA/WDMA/CSA 101/I.S.2/A440-05 FW-R70 2720 x 1955 (107 x 77) ASTM E1886-05/E1996-04 Wind Zone 4-Missile Level D TAS 201/202/203-94 Design Pressure: +70/-70 Large Missile Impact Rated Product Tested By: National Certified, Testing Laboratories Report No: NCTL-110-1061f-1/110-1Q�6 10-10616-3 Expiration Date: December 31.2020 Administrator's Signature: NATIONAL ACCREDITATION AND MANAGEMENT INSTITUTE, INC. 4794 George Washington Memorial Highway Hayes, VA 23072 Tel:, (804) 684-5124 Fax: (804) 684-5122