HomeMy WebLinkAboutPRODUCT APPROVAL WINDOW SINGLE HUNGn
Florida Building Code Online
Page 1 of 2
BCIS Home I Log In I User Registration Hot
Product Approval
Vor
a USER: Public User
Product Approval Menu > Product or Application St
���-
"",L��y e�
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
SCANNEDBY
��`7 aLaLpp��pp11 aGaG QQQQQQpppppp ���� ,��,((,,''rr 0 � ..
Submit Surcf rge_j��tats �'Pribl!cations i FBC Staff. I BCIS Slte.Map �Links ��r `Search
I> Application List > Application Detail
FL11412-R7
Revision
2017
Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified
by the POC and/or the Commission if necessary.
I
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
rk
Regency Plus Incorporated
2000 Locust Gap Highway
Mount Carmel, PA 17851
(570)339-3374
tonyp@conservationwindows.com
Tony Procopio
tonyp@conservationwindows.com
Joe Korzeniecki
2000 Locust Gap Hwy.
Mount Carmel, SD 17851
(570)339-3374
joek@window-pros.info
Joe Korzeniecki
2000 Locust Gap Hwy.
Mount Carmel, PA 17851
(570)339-3374
joek@window-pros. info
Windows
Single Hung
Certification Mark or Listing
National Accreditation & Management Institute
National Accreditation & Management Institute
Standard
AAMA/N W W DA 101/I.5.2-97
TAS 201
TAS 202
TAS 203
Year
1997
1994
1994
1994
Florida Licensed Professional Engineer or Architect
FL11412 R7 Equiv EERNo2521 RevO FL11412 2000-5000 SH ss.odf
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgv8JygqZ9 Wu... 4/25/2018
Florida Building Code Online-,
1
Product Approval Method Method 1 Option A
1. f
Date Submitted 02/05/2018
Date Validated + 02/05/2018
Date Pending FBC Approval
Date Approved 02/09/2018
1
Rummary of Prndurts
Page 2 of 2
FL #
Model, Number or Name
Description
11412.1
Series'2000
Series 2000 Vinyl Tilt Single Hung Window
Limits of Use I
Certification Agency Certificate
Approved for use in HVHZ: No
FL11412 R7 C CAC NI006135-R8.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: No 1
12/31/2021
Design Pressure: +40/-40 1
Installation Instructions
Other:
FL11412 R7 II RPLS0047 RevC 2000 SH ss.odf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
I
Created by Independent Third Party: Yes
Evaluation Reports
FL11412 R7 AE PERNo2521 RevO FL11412 2000-5000
SH ss.Ddf
Created by Independent Third Party: Yes
11412.2
Series 5000
Series 5000 Impact Vinyl Tilt Single Hung Window
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ:, Yes
FL11412 R7 C CAC NI006712-R4.pdf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: Yes
03/31/2021
Design Pressure: +55/-55
Installation Instructions
Other:
FL11412 R7 II RPLS0048 RevC 5000 SH ss.Ddf
Verified By: Robert J. Amoruso, PE FL PE No. 49752
Created by Independent Third Party: Yes
Evaluation Reports
FL11412 R7 AE PERNo2521 RevO FL11412 2000-5000
SH ss.Ddf
Created by Independent Third Party: Yes
1
,
I Back Neut
I
,
Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement
I
Under Florida law, email addresses are public records. If you do not want your e-mail address released in response to a public -records request, do not send
electronic mail to this entity. Insteaa, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to
Section 455.275(1), Florida Statutes; effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if
they have one. The emails provided] may be used for official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under
Chapter 455, F.S., please click here .
Product Approval Accepts:
OR =
Credit Card
Safe
I
I
i
I
I
1
1
I
I
i
1
https://www.floridabuilding.org/pr/pr_app_dtl. aspx?param=wGEVXQwtDgv8JyggZ9 Wu... 4/25/2018
a
6" MAX.
76"
MAX.
FRAME
HEIGHT
REGENCY PLUS, INC.
SERIES 5000 IMPACT VINYL TILT SINGLE HUNG WINDOW
52" MAX. FRAME WIDTH
13.5 " MAX O.C. 6" MAX
6" MAX
/
/ O
/
X
/
/
ELEVATION
NOTES: EXTERIOR VIEW
1. MAXIMUM TOP FIXED LITE D.L.O.: 46-518" X 32-7/8".
2. MAXIMUM BOTTOM SASH SIZE: 50' X 38" WITH D.L.O.46-114" X 33-5/8".
1 1 " MAX
O.C.
6" MAX
HARDWARE SCHEDULE
A.
(1) METAL CAM -TYPE SWEEP LOCK 11-112" FROM EACH END OF INTERIOR MEETING STILE
B.
(1) METAL KEEPER AT EXTERIOR FIXED MEETING STILE
C.
(1) METAL TILT LATCH WITH THUMB ACTUATOR AT EACH END OF SASH TOP RAIL
D.
(1) DIE-CAST METAL PIVOT BAR IN A NYLON SHOE
E.
(1) STEEL REINFORCEMENT AT INTERIOR MEETING RAIL
INSTALLATION ANCHORAGE DETAILS
NOTES:
1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE CURRENT FLORIDA BUILDING
CODE INCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ).
2. WOOD FRAMING, 2X WOOD BUCK, METAL FRAMING AND CONCRETEIMASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY
TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND CONCRETE/MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR
ENGINEER OF RECORD.
3. 1X BUCK OVER CONCRETEIMASONRY IS OPTIONAL. WHERE 1X BUCKS ARE USED, INSTALLATION ANCHORS WILL PASS THROUGH WINDOW
FRAME AND 1X BUCK INTO CONCRETEIMASONRY SUBSTRATE. WHERE 1X BUCK IS NOT USED, INSTALLATION ANCHORS WILL PASS THROUGH
WINDOW FRAME INTO CONCRETE/MASONRY SUBSTRATE. DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR
MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD.
4. THE PRODUCT SHOWN HEREIN HAS BEEN TESTED TO TAS 201, TAS 202 AND TAS 203. SEE TEST REPORT NO. NCTL-210-2966-1,2,3 DATED 215/04
(REVISED 3/29/05) BY NATIONAL CERTIFIED TESTING LABORATORIES, ORLANDO, FL FOR DETAILS.
5. MATERIAL:
6.1. FRAME: EXTRUDED RIGID PVC.
5.2. REINFORCEMENT: GALVANIZED STEEL TUBE - MEETING RAIL MEMBER.
6. GLAZING: _
6.1. GLAZING DETAILAS TESTED: 7/8"-NOMINAL OA IGU COMPRISED OF FROM EXTERIOR TO INTERIOR- LAMI LITE OF 1/8" ANNEALED GLASS x
0.090' KURARAY AMERICA SENTRYGLAS (SG) INTERLAYER x 118" ANNEALED GLASS, DESICCANT STEEL SPACER, 118' TEMPERED SACRIFICIAL
LITE. BOTTOM SASH INTERIOR GLAZED WITH SIKA SIKAFLEX 552 BACK -BEDDING (OR EQUIVALENT), TWO (2) LEAF DUAL DUROMETER
BACK -BEDDING AND A SNAP -IN TWO (2) LEAF DUAL DUROMETER GLAZING BEAD WITH 7/16" GLASS BITE. TOP FIXED LITE INTERIOR GLAZED
WITH A SNAP -IN TWO (2) LEAF DUAL DUROMETER RIGID VINYL GLAZING BEAD AND SIKA SIKAFLEX552 BACK -BEDDING (OR EQUIVALENT)
WITH 7/16" GLASS BITE.
6.2. AS TESTED GLAZING MEETS ASTM E1300-09a FOR THE DESIGN CONDITIONS SHOWN IN THIS PRODUCT APPROVAL DOCUMENT.
6.3. ALTERNATE GLAZING MEETING THE REQUIREMENTS OF AAMAIWOMA/CSA 101/I.S.2/A440 SHALL BE ALLOWED PER ASTM E1300.
6.4. SETTING BLOCKS IF USED AND/OR WHERE REQUIRED BY THE CURRENT EDITION OF THE FLORIDA BUILDING CODE SHALL BE NEOPRENE
WITH A 70 TO 90 SHORE A DUROMETER. GLAZING BEADS (GASKETS) SHALL MEET THE CURRENT EDITION OF THE FLORIDA BUILDING CODE
AS REQUIRED.
7. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS.
B. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM
ALLOWABLE SHIM STACK TO BE 1/4".
9. FOR ANCHORING INTO CONCRETE/MASONRY USE 3/16" HEX HEAD TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/2" MINIMUM
EMBEDMENT INTO CONCRETE WITH 1 1/8' MINIMUM EDGE DISTANCE AND 1" MINIMUM EMBEDMENT INTO MASONRY WITH 2' MINIMUM EDGE
DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. ANCHOR LOCATIONS HAVE +/. 1" TOLERANCE.
10. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 PAN HEAD WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM
EMBEDMENT INTO SUBSTRATE WITH 3/4" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
ANCHOR LOCATIONS HAVE +/- 1"TOLERANCE.
11. FOR ANCHORING INTO METAL STRUCTURE USE #10 PAN OR HEX HEAD SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3
THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL WITH 314' MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS
AND INSTALLATION DETAILS. ANCHOR LOCATIONS HAVE+/- 1"TOLERANCE.
12. ALL FASTENERS TO BE CORROSION RESISTANT.
13. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS AND ANCHORS
SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW:
13.1. WOOD - MINIMUM SPECIFIC GRAVITY (G) OF 0.42 (NON-HVHZ) AND 0.55 (HVHZ)
13.2. CONCRETE- MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI
13.3. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, MEDIUM WEIGHT WITH DENSITY> 117 PCF
13.4. METAL STRUCTURE: STEEL 18GA (0.0428'), 33KSI OR ALUMINUM 6063-T5 0.048" THICK MINIMUM
TABLE OF CONTENT
SHEET
DESCRIPTION
1
ELEVATION, ANCHORING AND NOTES
2
INSTALLATION DETAILS
DESIGN PRESSURE RATING (PSF)
IMPACT RATING
LARGE AND SMALL
+55.01-55.0
MISSILE IMPACT
r1V P1L HNU VVINU LUNt 4, MISJILt LtVLL U
O m OI N
0
O
a tU m 3)
I—
r �z
Q =
W O
Ur Za < n
24 U)Z 'K Z U
D 1 FIt
� F=
W
U), >Z
U¢-¢
U U > Z
H
o� QO
EL
N � W
�w pB 1
n
w
/n
W
y
Robert J. Amoroso, P.E.
Flodda P.E. No. 49752
,P1'AMENES �
4•. �Gy q�i�
N 49752 •O n
Z •0
E OF
• a
',�'SS�ONA��E��.•
Digitally signed.
by Robert J
Amoruso
Date:'2018.02.02
13:31:27-05'00'
PTC Pmduol Design Gmup, LLC
PO Box 520775
Longwood, FL 3211 2-0175
321-690-1788 Inlo@ptcmrp.mm
FBPE Certificate of Authorization
No. 25935
INSTALLATION ANCHOR. WOOD
SCREW SHOWN. SEE NOTE 5 a a
THIS SHEET FOR ANCHOR MIN. EMBEDMENT, O
TYPE REQUIRED. SEE NOTE 5 THIS o
SHEET.
MIN. EDGE DISTANCE. SEE 1/4" MAX. o w
NOTE 5 THIS SHEET. MIN. SHIM SPACE as m m
INSTALLATION ANCHOR. WOOD
EMBEDMENT, SEE
NOTE 5 THIS SHEET. INTERIOR SCREW SHOWN. SEE NOTE 5 w U o
THIS SHEET FOR ANCHOR TYPE 'p o z
INSTALLATION SUBSTRATE REQUIRED. a w o
BY OTHERS. SEE NOTES n w
1 TO 3 THIS SHEET. O
MIN. EDGE
DISTANCE. SEE
� O 1/4" MAX. NOTE 5 THIS
SHIM SPACE SHEET.
PERIMETER SEAL Q° °� o
BY OTHERS /In�J z--
Ej
w 3 INSTALLATION SUBSTRATE z a o
EXTERIOR PERIMETER SEAL BY OTHERS. SEE NOTES 1 >- _
- — — --BY-OTHERS - -- — -- TO 3-THIS -SHEET.--wm _
WINDOW WIDTH - i a
,= a u5w
a �
in
HORIZONTAL (JAMB) CROSS SECTION J Q IL cD —] =Z
g
WOOD FRAMING, 2X WOOD BUCK, Y _ w F
CONCRETE/MASONRY OR METAL FRAME tZ z g
° APPROVED �
O u r
WINDOW ° jj INSTALLATION NOTES: Jo <Z
HEIGHT EXTERIOR ❑ II D INTERIOR 1, APPROVED INSTALLATION SUBSTRATES INCLUDE THE FOLLOWING: N
11 1.1. WOOD FRAMING o g 1
1.2. STEEL STUD FRAMING AND
1.3. CONCRETE AND/OR MASONRY w
2. SUBSTRATE OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO
(� n STRUCTURE. FRAMING AND CONCRETE/MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT fn
If JI �JC� OR ENGINEER OF RECORD. v 1 4
❑
3. 1X BUCK OVER CONCRETEMASONRY IS OPTIONAL. WHERE 1X BUCK IS NOT USED, DISSIMILAR Robert J. Amoroso. P.E.
n �J MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR Florida P.E. No. 49752
lul a MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. ••••�p���p���
•• SPIAES
4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF "I" Al ��GEN 1�
1116" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 114". '`C; Nu 49752
Q° 1/4" MAX. 5. SUBSTRATE ANCHORING METHODS: v
PERIMETER SEAL SHIM SPACE 5.1. FOR ANCHORING INTO CONCRETEIMASONRY USE W16" HEX HEAD TAPCONS WITH SUFFICIENT
BY OTHERS GE
DISTANCE AND V MI MUM EMBEDMENTIEMBEDMENTMUM OCONCRETE D INTO MASONRY A WITH 2MINIMUM EDGE DISTANCE. ..........
ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. ANCHOR LOCATIONS HAVE +/-1• ,���gS,�ONAm"•`
MIN. TOLERANCE. >
INSTALLATION SUBSTRATE DI Itd�� 51 ❑ECI
BY OTHERS. SEE NOTES EMBEDMENT, SEE 5.2. FOR ANCHORING INTO WOOD FRAMING OR 2X BUCK USE #10 PAN HEAD WOOD SCREWS WITH g y g
1 TO 3 THIS SHEET. NOTE 5 THIS SHEET. SUFFICIENT LENGTH TO ACHIEVE A 1 3/8" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 3/4• MINIMUM by Robert J
EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS.
ANCHOR LOCATIONS HAVE+/- 1" TOLERANCE. AmorU$O
MIN. EDGE DISTANCE. SEE INSTALLATION ANCHOR. WOOD 5.3. FOR ANCHORING INTO METAL STRUCTURE USE #10 PAN OR HEX HEAD SMS OR SELF DRILLING Date: 2018.02.02
NOTE 5 THIS SHEET. SCREW SHOWN. SEE NOTE 5 SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE 13:31:40-05'00'
THIS SHEET FOR ANCHOR TYPE INTERIOR WALL WITH 3/4• MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS
VERTICAL CROSS SECTION REQUIRED. AND INSTALLATION DETAILS. ANCHOR LOCATIONS HAVE +/-1•TOLERANCE. PTC Product Design Group, LLC
75
WOOD FRAMING, 2X WOOD BUCK, 6. INTERIOR AND EXTERIOR FINISHES BY OTHERS. NOT SHOWN FOR CLARITY. Long —PO Box 32752
75
CONCRETE/MASONRY OR METAL FRAME 321i90. e6�FL
fo pIc2c rp.
@ptocorp•com
APPROVED 7. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED AND/OR SPECIFIED IN ACCORDANCE WITH FBPE Certificate of Authorization
ASTM E2112. No.25935
Product Evaluation Report
Rule 61G20-3 F.A.C. I Report No. 2521 1 Project No. 417-0906 1 1/11/18 1 Page 1 of 2
Product Manufacturer
Regency Plus Incorporated
2000 Locust Gap Highway
Mount Carmel, PA 17851
Florida Product Approval No.: FL11412
Code: Current Edition of the Florida Building Code:
Product Name, Model and/or Description
2000 Vinyl Tilt Single Hung Window
5000 Impact Vinyl Tilt Single Hung Window
Compliance Method: Product Approval Rule 61G20-3.005(1)(a) — Certification Mark or Listing
Product Name, Model and/or Designation, Test Report No. and Installation Drawing No.:
• 2000 Vinyl Tilt Single Hung Window
o Test reports and associated laboratory drawings by National Certified Testing Laboratories, Orlando, FL.
■ NCTL-210-2728-1, dated 1/11/02 to AAMA/NWWDA 101/I.S.2-97
o PTC Product Design Group Drawing No. RPLS0047, Rev. C, dated 1/22/18, signed and sealed by Robert J.
Amoruso, P.E., FL License Number 49752
• 5000 Impact Vinyl Tilt Single Hung Window
o Test reports and associated laboratory drawings by National Certified Testing Laboratories, York, PA signed
and sealed by Gerard J. Ferrara, P.E.
■ NCTL-210-2968-1,2,3, dated 2/5/04 (revised 3/29/05) to TAS 201-94, TAS 202-94 and TAS 203-94
o PTC Product Design Group Drawing No. RPL50048, Rev. C, dated 1/22/18, signed and sealed by Robert J.
Amoruso, P.E., FL License Number 49752
1
Engineering Analysis Et Evaluation:
• Anchorage engineering in accordance with the current edition of the Florida Building Code for 2000 & 5000 Vinyl
Tilt Single Hung Window signed and sealed by Robert J. Amoruso, P.E., FL License Number 49752.
Component Approvals: Impact interlayer code conformance based on the following.
• Kuraray America SentryGlas (SG) interlayer code conformance per the currently issued Miami -Dade NOA to the
Current Edition of the Florida Building Code. See Miami -Dade NOA listing here.
Performance Testing:
• AAMA/NWWDA 101/I.S.2-97
• TAS 201-94, TAS 202-94 and TAS 203-94
Limitations Ek Conditions of Use:
2000 Vinyl Tilt Single Hung Window
o This product has not been evaluated for use inside the High Velocity Hurricane Zone (HVHZ).
o This product will require an approved impact protective system when used in wind borne debris regions.
5000 Impact Vinyl Tilt Single Hung Window
o This product has been evaluated for use inside the High Velocity Hurricane Zone (HVHZ).
o This product will not require an approved impact protective system when used in wind borne debris
regions.
Refer to Product Installation Instructions noted above for:
o Maximum allowable wind loads at related maximum allowable size(s).
o Overall dimensions and material/grade of main product components, accessories, etc.
o Illustrated diagrams of the attachment of the product to substrate structure.
��A� PTC Product Design Group, LLC I PO Box 520775 1 Longwood, FL 32752-0775
THEW 321-690-1788 1 FBPE Certification of Authorization No. 25935
Product Evaluation Report
Rule 61G20-3 F.A.C. 1 Report! No. 2521 1 Project No. 417-0906 1 1/11/18 1 Page 2 of 2
I
o Anchor type(s), size(s), substrate(s), embedment, edge distance, and spacing/locations.
Site wind pressures shall be determined by a licensed professional engineer in accordance with the current edition
of the Florida Building Code and/or ASCE 7-10 for components and cladding based on allowable stress design.
Site conditions not covered in this product evaluation document are subject to additional engineering analysis by a
licensed professional engineer or registered architect as required by the authority having jurisdiction.
Adequacy of the existing structural substrates as a main wind force resisting system capable of withstanding and
transferring applied product loads to' the foundation .is the responsibility of the licensed professional engineer or
registered architect acting as the design professional of record for the project of installation.
Certificate of Independence per Product
Approval Rule 61 G20-3.009 i
PTC Product Design Group, LLC and Robert J. Amoruso,
P.E. does not have, nor will acquire, any financial
interest in the company manufacturing or distributing
product(s) covered by this Product Evaluation Report.
I
PTC Product Design Group, LLC and Robert J. Amoruso,
P.E. do not have, nor will acquire any financial interest
in any other entity involved in the approval process or
testing of the product(s) covered by this Product
Evaluation Report. i
�111111:Alllllf
rAVL
AMES
.�CENS4S
to 49752 •'
�cc Z
�UA
: STAEOF ::j4I
S C9 ��
Z,,�1,2NA��
i
I
PTC Product Design Group, LLC
321-690-1788 1
I
Digitally signed
by Robert J
Amoruso
Date:
.4,
2018.01 3�1
12:45:24-05'00'
Evaluated By:
Robert J. Amoruso, P.E.
FL P.E. License Number 49752
I PO Box 520775 1 Longwood, FL 32752-0775
FBPE Certification of Authorization No. 25935
NOTICE�X)')F PRODUCT CERTIFk, -LTION
CERTIFICATION NO: NI006712-R4
DATE: 09/18/2006
CERTIFICATION PROGRAM: Structural
COMPANY: Regency
CODE: 750-1
REVISION DATE: 05/26/2015
To verify that the "Notice of Product Certification" is valid, please visit www.NAMICertification.com to assure that the
product is active and currently listed. This certification represents product conformity to the applicable specification and
that certification criteria has been satisfied. A NAMI approved certification label must be applied to the product to claim
certification status. Please review and advise NAMI if any corrections are required to this document.
COMPANY NAME AND ADDRESS
PRODUCT DESCRIPTION
Regency Plus, Inc. I
Series "Tech 5000"
2000 Locust Gap Highway
Vinyl Single Hung Window
Mount Carmel, PA 17851
Configuration: O/X
Glazing: IG-Laminate-1/8" Annealed Glass/
0.090" SentryGlas®Plus PVB/l/8" Annealed Glass/
1/8" Tempered Glass
Frame: W-1321mm(52") H-1930mm(76")
Sash: W-1270mm(50") H-965mm(38")
SPECIFICATION
PRODUCT RATING
TAS 201/202/203-94
Design Pressure: +55/-55 psf
Large Missile Impact Rated
Product Tested By: National Certified Testing Laboratories
Report No: NCTL-210-2968-1,2,3
Expiration Date: March 31, 2021
Administrator's Signature:
NATIONAL ACCREDITATION AND
MANAGEMENT INSTITUTE, INC.
4794 George Washington Memorial Highway
Hayes, VA 23072
Tel: (804) 684-5124
Fax: (804) 684-5122