Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFINGF Florida Building Code Online - } s Page 1 of 3 SCANNED BY G Lucie County �. r BCIS Home { Log In User Registration Hot Topics ; Submit Surcharge ° Stats & Facts Publications FBC Staff { BCIS Site Map I Links I Search { Florida I ' YY11 Product Approval USER: Public User ProdurI.Approval Menu > Product or Application Search > Application List > Application Detail ,�.. vmd FL # I FL11651-R3 Application Type Revision y 1, ,., Code Version j 2017 Application Status- Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory C Gulf Coast Supply & Manufacturing, LLC. 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352) 498-0778 info@gulfcoastsupply.com Ray Bowen info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 info@gulfcoastsupply.com David Eng 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Roofing Metal Roofing ST. LUCIE COON" BUILDING DIVISION RI:VIEWE(1 FOIa CO nPER REVIEWED BYDATE PLANS ANIT MUST SE KEPT ON JOB OR NO INSPECTION WILL BE MADE Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 1) Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed Daniel S. Kuhn the Evaluation Report g 51 Florida License PE-75519 vOlYy�y� L6f0.1ur1� Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date04/12/2024 Validated By Locke Bowden tr" "t' !1'' •{'?i"' r W Validation Checklist - Hardcopy Received Certificate of Independence FL11651 R3 COI Cert of Independence 2017-10-09.1)df Referenced Standard and Year (of Standard) Standard FM 4471 TAS 100 TAS 110 TAS 125 UL 1897 UL 580 ea 1992 1995 2000 2003 2012 2006 https://www.floridabuilding.org/pr/pr_app_d tl.aspx?param=wGEVXQwtDgsQFc5K%2f Tr... 2/9/2018 .y Florida Building Code Online Page 2 of 3 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page = a Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 id 0 Page 2/29J '01 FL # IModel, Number or Name Description 11651.21 1 26 Ga. GulfRib Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 21 R3 Metal Roof Panel Detail - Approved for use outside HVHZ: Yes sioned.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-164.2PSF I Created by Independent Third Party: Yes Other:-109.25 psf @ 24" o.c. fastener spacing. Evaluation Reports -164.25 psf @ 12" fastener spacing. Install per FL11651 R3 AE FL11651 21 R3 26GulfRib 1x4 IS - manufacturer's details. Not for use in HVHZ Zones 32Plvwood NonHVHZ-sioned.pdF Created by Independent Third Party: Yes II�165 j261GE,%GUI_fR b _ pj Min 26 Ga. GulfRib over 15/32" Plywood _units of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant-_N/ Installation Instructions FL11651 R3 II FL11651 22 R3 Metal Roof Panel Detail- sianed.odf Verified By: Dan Kuhn, P.E. 75519 heated by Independent Third Party: Yes aluation Reports FL11651 R3 AE FL11651 22 R3 26GulfRib 15- Created by Independent Third Party: Yes 11651.23 126 Ga. GulfRib I Min 26 Ga. GulfRib over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 23 R3 Metal Roof Panel Detail - .Approved for use outside HVHZ: Yes sioned.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party: Yes Other: -71.75 psf @ 24" o.c. fastener spacing. Evaluation Reports -159.25 psf @ 12" fastener spacing. Install per FI-11651 R3 AE FL11651 23 R3 26GulfRib 15- manufacturer's details. For use in HVHZ Zones 32Plvwood HVHZ-sianed.pdf ' Created by Independent Third Party: Yes 11651.24 126 Ga. GulfRib Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ:-Yes Impact Resistant: N/A Design Pressure: +N/A/-164.2PSF Other:-106.75 psf @ 24" o.c. fastener spacing -164.25 psf @ 12" fastener spacing. Install per manufacturer's details. For use in HVHZ Zones 11651.25 129 Ga. GulfRib Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -76.75 psf @ 24" o.c. fastener spacing. -123.5 psf @ 24" fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones Min 26 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 24 R3 Metal Roof Panel Detail- sioned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 24 R3 26GulfRib 1x4 15- 32Plywood HVHZ-siyned.pdf Created by Independent Third Party: Yes Min 29 Ga. GulfRib over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651. R3 II FI-11651 25 R3 Metal Roof Panel Detall- sianed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 25 R3 29GulfRib 1x4 15- 32Plvwood NonHVHZ-siolied, odf Created by Independent Third Party: Yes https://www.flor'rdabuilding.org/pr/pr—app_dtli.aspx?param=wGEVXQwtDgsQFc5K%2f Tr... 2/9/2018 91 6.5" FL# 11651.22 R3 • OCTOBER 5, 2017 I TYPE1 FASTENER PATTERN a al Gulf SUPPLY & MANUFACTURING �471 v z At Panel I Cont. Tape Seal for use on Slopes less than 3:12 Z(1) #9-15 x 1-1/2" w/Sealer Washer @ 24" O.C. Max. TYPE,2 FASTENER PATTERN 2.5" 6.5" 2.5" 6.5" 2.5" 6.5" 7 2.5" 7 1J� i Cont. Tape Seal for use on Slopes less than 3:12 zo) #9-15 x 1-1/2"V/Sealer Washer @ 12" O.C. Max. I '�`%J11111101 %.% �11EL S. k �. �CEIry • y . F , ` * ; No, 75519 13 '. STATE OF CREEK TECHNICAL SERVICES, EVALUATION REPORT Manufacturer: Quality Assurance: SCOPE TAMKO BUILDING P.O. Box 1404 Joplin, MO 64802 (417)624-6644 UL LLC (QUA9625) Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813) 4803421 FLORmA Buil_D1NG CODE, GP EDMON (2017) INC. Issued October 19, 2017 RECEIVED JAN 2 9 2018 ST, Lucia + gunty, Wf1 Ittln� Category: Roofing Subcategory: Underlayments Code Sections: 1507.1.11, . tq Properties: Physical properties ?'' "icy" t, PRoDucT DESCRIPTION TAMKO® ASTM Slate ASTM D 6380, Class M, Type II underlayment constructed from organic felt saturated Surfaced Roll Roofing with asphalt and coated on both sides with asphalt and surfaced with granules. I TAMKO® ASTM Tile ASTM D 6380, Class M, Type II underlayment constructed from an organic felt saturated Underlayment with asphalt then coated on both sides with asphalt and surfaced with granules. i TAMKO® Master ASTM D 6380, Class S, Type IV underlayment constructed from an organic felt saturated Smooth with asphalt then coated on both sides with asphalt and surfaced with a fine mineral. For use in non-HVHZ only. I TAMKO® Moisture Self -adhered, ASTM D 1970, fiberglass reinforced, modified bitumen sheet membrane Guard® with a mineral surfacing and a removable release film on the adhesive side and removable selvedge release tape. TAMKOC) No. 9S ASTM ASTM D 226, Type I ulnderlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO® No. 15 UL ASTM D 226, Type I underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt. Organic Felt TAMKO® No. 30 ASTM ASTM D 226, Type II underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO® No. 30 UL ASTM D 226, Type ll'underlayment constructed from a non -perforated organic felt that is Asphalt Saturated saturated with asphalt Organic Felt TAMKO@TW Metal and Self -adhered, flexibl I, ASTM D 1970 and TAS 103, rubberized asphalt sheet membrane Tile Underlayment with a polymer film on the surface and a removable release film on the adhesive side. TAMKO®TW Self -adhered, flexibl6, ASTM D 1970, rubberized asphalt sheet membrane with a Underlayment polymer film on the surface and a removable release film on the adhesive side. I TBP14001.4 This evaluation report is provided for State of Floric Technical Services, LLC of any product changes or This evaluation report does not express nor imply specifically addressed herein. FL12328-R8 Page 1 of 4 ict approval under Rule 61G203. The manufacturer shall notify CREEK assurance changes throughout the duration for which this report is valid. r, installation, recommended use, or other product attributes that are not 0 CREEK TAMKO BUILDING PRODCUTS, INC. YAMKO Underlayments TECHNICAL SERVICES, LLC TAMKC@ TAM -FELT Alternate to ASTM D 226, Type I and Type 11 underlayment constructed from a non - perforated organic felt that is saturated with asphalt. APPLICATION METHOD Installation shall be in accordance with the published manufacturer's installation instructions, the FLIG, and me requirements below. Deck substrates shall be clean, dry, and free from any irregularities and debris. All fasteners in the deck shall be checked for protrusion and corrected prior to underlayment application. The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. Plywood deck shall be installed in accordance with FBC requirements. Roof decks shall have no more than 1/8" gap at abutling joints. The minimum application temperature shall be 50°F� except as follows: a) The minimum application temperature, cf TAMKOO TW Metal and Tole Underlayment and TAMKO®TW Underlayment shall be 40°F. b) The minimum application temperature of TAMKO® Moisture Guard® shall be 35°F. The minimum roof slope shall be in accordance with F$C requirements except as follows: a) The minimum slope of TAMKO® ASTVI Slate Surfaced Roll Roofing shall be 2:12. Undertayments shall be exposed in accordance with the manufacturer's recommendations, but in no case shall exposure exceed 30 days. Exception_ TAMKO® TW Metal and Tile , nderlayment may be exposed for a maximum 90 days. Self -adhering underiayments may be adhered to primed a unplimed plywood substrates in the non-HVHZ All roof coverings shall be mechanically fastened through the underlayment to the roof deck. I Allowable Roof Covednas: Metal Roof Mineral Wood Asphalt Panels and Surfaced Roll, Shingles and Slate Clay and Underlayment Shingles Shin les • _ _: _. Roofing Shakes in les Concrete Tile TAMKO® ASTM Slate Y' N N N N Y Surfaced Roll Roofing TAMKO® ASTM Tile N N N N N Y Underlayment TAMKO® Master Smooth Y' N N N N N TAMKO® Moisture Guard® Y N N N N N TAMKO® No. 15 ASTM Asphalt Saturated Organic Y Y Y YZ N N Felt TAMKO® No. 15 UL Asphalt Y Y Y YZ Y N Saturated Organic Felt TAMKO® No. 30 ASTM Asphalt Saturated Organic Y Y Y Y Y Y Felt TAMKO® No. 30 UL Asphalt Y Y Y N Y N Saturated Organic Felt TAMKO® TW Metal and Tile Y Y N N N Y Underlayment TAMKO® TW Underlayment Y Y N N N N TAMKO® TAM -FELT Y N N N N N Notes: 1) Open valley applications per 1507.2.9.2 2) Wood shingles only TBP14001.4 FL12328-R8 Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHMCAL SERVICES, LLC LIMITATIONS TAMKO BUILDING PRODCUTS, INC. TAAMKO Underlayments 1) Fire Classification is not within the scope of this evaluation. 2) Wind uplift resistance in not within scope ofi'this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturer's published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant installation detail shall prevail. 4) Contact the manufacturer when installing at temperatures below the minimum application temperature. 5) Unless otherwise stated, the minimum roof'slope shall be in accordance with FBC requirements. 6) All underlayments shall be installed with the roll length parallel to the eave, starting at the eave, and lapped in successive courses installed up, the deck in a manner that effectively sheds water from the deck. End laps shall be staggered between courses it accordance with the manufacturer's application instructions. 7) The underlayment may be used as described in other current FBC product approval documents. 8) The underlayment shall not be installed over existing roof coverings. 9) Contact the manufacturer regarding specific exposure limits for each underlayment 10) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61G20-3. REFERENCES ED ; Report No. Standard Year PRI Construction Materials Technologies (TST6049) TAP-192-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-193-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-214-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-215-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-216-02-03 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-217-02-01 REV ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-218-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-219-02-01 ASTM D 226 2009 PRI Construction Materials Technologies (TST6049) TAP-220-02-01 ASTM D 6380 2003(2013) PRI Construction Materials Technologies (TST6049) TAP-222-02-01 ASTM D 4869 2016 PRI Construction Materials Technologies (TST6049) TAP-245-02-01 TAS 103 1995 ASTM D 4798 2011 PRI Construction Materials Technologies (TST6049) TAP-011-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-319-02-01.1 ACC 188 2012 PRI Construction Materials Technologies (TST6049) TAP-087-02-01 ASTM D 1970 2015a PRI Construction Materials Technologies (TST6049) TAP-388-02-01 ASTM D 1970 2015a UL LLC (TST9628) 13CAM69 ASTM D 226 2009 TBP14001.4 FL12328-R8 Page 3 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. o- CREEK TECHNICAL SERVICES, LLC COMPLIANCE STATEMENT TAMKO BUILDING PRODCUTS, INC. TAMKO Underlayments The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code, 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. R. • PR��i,. `�,•;�QG•��GENs .Fs2017.10.19 No 74021,.12:15:58 � • WVs4WMLMRRM 0 :. STATE O F : �[t1 •'cN��.� Zachary R. Priest, P.E. �i�s • R 1.•• ' �� Florida Registration No. 74021 Organization No. ANE9641 CERTIFICATION OF INDEPENDENCE CREEK Technical Services, LLC does not have, nor will it acquire, is financial interest 1n any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation_ Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. END OF REPORT T13P14001.4 FL12328-R8 Page 4 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.