HomeMy WebLinkAboutSPECIFICATION & DESIGNra L GIRTS: TION NOTES AND DESIGI, POLY ROOF CARPORT THIS CARPORT STRUCTURE MEETS THE FLORIDA BUILDING CODE FOR A HEIGHT 7'-11", EXP. 'C', 150 MPH WIND SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED IN THE FLORIDA BUILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION OF FLORIDA (AAF) "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL VALUES FOR EXTRUDED ALLOY 6005T5 ARE TAKEN FROM THE ALUMINUM DESIGN MANUAL. 2015 EDITION. TABLE 1 MAIN ROOF MEMBER SCHEDULE MEMBER Tm—A-g--K[MANF.1 WEIGHT MATERIAIJ THICKNESS ILENGTH DESIGN BASIS # SKIN I POLY I SKIN I FT. FL. PROD. APPR. POLY ROOF PANEL # 1 PRP1 ELITE 1 ALUM 1 3" 1 0.024 1 13' 3 FL756)24,,DW` OR = >"{1Ob1;:8121 TABLE 2 MAIN MEMBER SCHEDULE MEMBER ___TMARKT SIZE IMATERIALI TYPE I THICKNESS ILENGTH DESIGN BASIS b x t I ALLOY I I W I F I FT. COLUMN # 1 COLUMN # 2 CARRIER BEAM # 1 EDGE BEAM # 1 MID BEAM # 1 KNEE BRACE # 1 Cl 3x3-9 ALUM TUBE 0.090 0.090 7'-11" 1 CALCULATION C2 3x3-9 ALUM TUBE 0.090 0.090 8'-5" CALCULATION C61 2x7 ALUM SMB 0.550 0.120 10'-4" CALCULATION EB1 2x3H ALUM HOLLOW 0.090 0.090 11'-3" CALCULATION MB1 2x3H ALUM HOLLOW 0.090 0.090 11'-0" CALCULATION KB1 2x3-7 ALUM HOLLOW 0.070 0.070 1'-5" * CALCULATION ADDITIONAL SITE SPECIFIC INFORMATION NOTE: * AVERAGE THIS POLY ROOF CARPORT IS LOCATED IN A RESIDENTIAL COMMUNITY NORTH OF SE WALTON ROAD AND EAST OF U.S. ROUTE 1 IN PORT ST. LUCIE. THE CARPORT HAS SOME OPEN AREAS AROUND IT. THE ENCLOSURE IS VERY CLOSE TO THE SAVANNAS PRESERVE STATE PARK. PER THE EXPOSURE CATEGORIES LISTED IN SECTION 1609.4.3 OF THE FLORIDA BUILDING CODE THIS ENCLOSURE SHALL CONSERVATIVELY BE CALLED AN EXPOSURE 'C'. ACCORDING TO THE COMPUTER PROGRAM "WINDSPEED BY LOCATION", A PRODUCT OF 'APPLIED TECHNOLOGY COUNCIL' THE DESIGN WIND LOAD REQUIREMENTS FOR A RISK CATEGORY I ENCLOSURE IN THIS LOCATION IS DICTATED BY A WIND SPEED OF 148 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE ARE 150 MPH WIND LOAD, EXPOSURE 'C', RISK CATEGORY I. THE NEW POLY ROOF CARPORT IS BEING INSTALLED BECAUSE THE EXISTING CARPORT, WHICH WAS BUILT IN THE 1990S, WAS DAMAGED DURING A RECENT HURRICANE. THE FRONT IS 7'41" HIGH AND THE REAR IS 8'-5" HIGH; WITH A RUN OF 12.25 FEET GIVES A SLOPE OF ABOUT 0.49 INCHES PER FOOT. THE POLY ROOF CARPORT IS BEING BUILT ON AN EXISTING NOMINAL 4" SLAB THAT IS IN GOOD CONDITION. THIS FOUNDATION IS ACCEPTABLE FOR THIS SCREEN ENCLOSURE. THE DESIGN DRAWING IS SHOWN ON SHEET 2. THE POLY ROOF CONNECTION DRAWINGS ARE SHOWN ON SHEETS 3. - — THE HOST STRUCTURE IS A MODULAR HOME SO 4TH WALL CONSTRUCTION FOR COMPOSITE ROOFS WILL BE USED. THEREFORE, THE COLUMNS, BRACING AND CONNECTIONS SHOWN ON SHEET 2 ARE THE SAME IN THE BACK AS IN THE FRONT EXCEPT THAT THE BACK IS 9 INCHES HIGHER. THERE SHALL BE NO STRUCTURAL ATTACHMENT BETWEEN THE POLY ROOF CARPORT AND THE MOBILE HOME BUT IT IS ACCEPTABLE TO INSTALL FLASHING TO KEEP THE RAIN OUT. THE CARRIER BEAM TO COLUMN CONNECTION CAN BE MADE WITH 7" LONG CHANNELS AND FOURTEEN (14) #12 SMS, SEVEN (7) BETWEEN EACH CHANNEL AND COLUMN AND SEVEN (7) BETWEEN EACH CHANNEL AND CARRIER BEAM, SIMILAR TO KNEE BRACE CONNECTIONS ON SHEET 2. ALSO, SEE OPTIONAL CONNECTION DRAWINGS BETWEEN COLUMNS AND CARRIER BEAMS BELOW. ST, LUCIER COUNTY BUILDING DIVISION THESEI d ANU ALL PROPOSED ICE I W', a IV UI (`T REQUiRED REVIEWED BY 'E ti 1 a THAT j DATE 'Z-4-7-16 Mg BE NECESSA,",Y liq ORDER TO PLANS AND PERMIT COMPLY VVITN ALLP b MUST BE KEPT ON JOB OR- I_NW IN16PECTIONWILL BE MADE � R1 R1 1 THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 & 20 OF THE 2017 FLORIDA BUILDING CODE, H EDITION, BUILDING, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4 THE Rt AAF STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR THE TABLES ARE PLIED. A DESIGN BASICS: THIS POLY ROOF CARPORT IS A RISK CATEGORY I STRUCTURE. HEIGHT 7'-11", EXP.'C', 150 MPH B THE BUILDING CLASSIFICATION RISK CATEGORIES ARE FROM FBC, TABLE 1604.5 AND AREA LOCATION WIND SPEED ER Fie FBC, FIGURE 1609C. BUILDING CLASSIFICATION PER TABLE 27.2-1, ASCE 7-10. C DESIGN PRESSURE: FOR SOLID ROOF @ 30.96 PSF PER TABLE 2002.4. $r, �Uqe• D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD. E ALLOWABLE DEFLECTION: L 160 MINIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC. F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES. MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061T6; ALLOY # 6063T6 IS NOT ACCEPTABLE. B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED -IN THESE SECTIONS. ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO ANY INSTALLATIONS UTILIZING THE SUBJECT METHODS. C SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 X 14, 58% OPEN MINIMUM. OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION. D ANY CONNECTION USED, THAT IS NOT SHOWN ON THESE SHEETS, MUST MEET ALL FBC AND AAF GUIDELINES. E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. F A 2x2 OR A 2x3 SNAP MEMBER CAN ALWAYS REPLACE A 2x2 OR A 2x3 HOLLOW MEMBER, RESPECTIVELY. G WHEREVER SCREENING OR KICKPLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER USED TO SUPPORT THAT SCREENING OR KICKPLATE WILL BE A 1" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMBER. H ALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER. 1 IT IS ALWAYS ACCEPTABLE TO ADD OR RELOCATE A SCREEN DOOR AS LONG AS THE COLUMNS ARE NOT DISTURBED. 3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS, COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS, ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE IN ACCORDANCE WITH THE LATEST FBC EDITION, INCLUDING THE AAF. ALL INTERNAL CONNECTIONS SHALL MEET THE FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR. 4 WHERE APPLICABLE, THE LOCATION OF ALL "K" BRACING, WIND BRACING, EAVE RAILS AND CHAIR RAILS, ALONG WITH ANY DESIGN ABNORMALITY, ARE SHOWN AND/OR LISTED ON SHEET 2, THE "SITE SPECIFIC DRAWING". 5 _ ALL STRUCTURES ERECTED ON CONCRETE SLABS AND / OR FOOTERS SHALL BE CALCULATED FOR SUFFICIENT HOLD DOWN CAPABILITY TO MEET THE CODE REQUIREMENTS. ALSO, ALL TAPCONS, WEDGE ANCHORS (OR EQUAL) SHALL BE 24" O.C. (MIN.), BE 3" FROM THE EDGE OF THE SLAB AND HAVE A MINIMUM EMBEDMENT OF 2" INTO THE CONCRETE SURFACE. 6 THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST BE THE LISTED SPACING, +/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". ALL SPACING MUST NEVER BE GREATER THAN 8.0' O.C. 7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS: A THE SLAB MUST BE IN GOOD CONDITION, 4" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER MESH. B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN 24" ON CENTER WITH MINIMUM ENGAGEMENT OF 2". 8 ALL NEW SLABS, WITH OR WITHOUT FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, B 4" NOMINAL PATIO SLAB REQUIRES A VAPOR BARRIER IF THE SLAB ABUTS LIVING QUARTERS, C 4" NOMINAL PATIO SLAB WITH CONCRETE @ 3000 PSI (MIN.) WITH FIBER MESH OR REBAR AND WIRE, D SHALL BE SECURED TO EXISTING CONCRETE WITH #5 REBAR EVERY 24" O.C. TO AVOID SETTLEMENT, IF APPLICABLE. 9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, ICANNED B CONCRETE @ 3000 PSI (MIN.) WITH ONE #5 REBAR FOR 8" x 8" AND TWO #5 REBAR FOR LARGER FOOTER , BY [� 10 ALL NEW PERIMETER FOOTER POURED WITH A SLAB SHALL MEET THE FOLLOWING CONDITIONS: NJ� fE� cle Cuourifj A PERIMETER FOOTER AND THE SLAB SHALL BE MONOLITHICALLY POURED, ��33 B ALL REQUIREMENTS OF ITEMS 8 AND 9 ABOVE. 11 ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. 12 THIS DRAWING COVERS ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELECTRICAL, PLUMBING, ETC, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT. DWG. # RVC-2018-112, REV.1 I; j VET ruary 20, 2018 22018 S EET 1 OF 3 DESIGN DATA 1". EXP.'C'. 150 MPH R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: HALLSWORTH RESIDENCE ADDRESS: 7909 MEADOWLARK LANE CITY/STATE: PORT ST. LUCIE FL 34952 COUNTY: ST. LUCIE IS REVISION UPDATED THE PRODUCT 'PROVAL FOR THE POLY ROOF NELS. SEE SHADED AREA. ONLY EET 1 IS AFFECTED. THIS DRAWING IS ONLY ACCEPTABLE FOR BUILDING PERMITS & ONLY WHEN IT HAS THE ENGINEER OF RECORD'S RAISED SEAL. COPIES ARE NOT DEEMED VALID. THIS DOCUMENT IS THE PROPERTY OF R. A. DUNLEA, P.E. AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF R. A. DUNLEA. R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(a)-centurviink.net FLORIDA P.E. Lic. No. 42835 ►`'PNTHONY *�.: �uNO�i1Q839 9 TATE r lV ID OR /t ��1 ••••..• �ci �� ,�soies/ON AL Fao``oo