HomeMy WebLinkAboutDETAIL MANUAL►UPPLY
& MANUFACT-IRIRG
Figure 1 The Horseshoe Beach Gulf Coast Su
office (left) and manufacturing facility.
conditions. Both panels and trim are fabric
using state-of-the-art computerized equipir
found at our facilities in three locations in l
to assure uniformity and consistency in prc
manufacture. Panels are roll -formed to the
specified by customers in either Galvalumc
any of more than twenty colors of painted
gauge, 26-gauge, and 24-gauge high -tensile
ready for either customer pickup or on -site
ery (customers should call. about availabilit
24-gauge metal). Your Gulf Coast represen
is waiting to assist you in making the best c
for your particular roofing needs.
Gulf Coast's Gulf Rib® panels are fabj
from AZ-50 (painted) or AZ-55 (bare
Galvalume) grade 80 coil.stock (grade 50
bare Galvalume finish is not only durable
here in tl
.:. pro
Figure 3 The Gulf rib panel
or
metal,
of
PzI
G61cozi-\�t
SUPPLY & MANUFACTURING
The Gulf Coast Gulf Rib®
Roofing Panel
Gulf Coast Gulf rib® panels are a strong,
durable, economic, and attractive answer to
the growing demand for metal roofing needs
in Florida and southern Georgia. Extremely
versatile, they are suitable for homes and
businesses as well as agricultural and utility
buildings Gulf Rib® panels provide a 36-
inch coverage with 3/4 inch ribs on nine -inch
centers, and utilize an anti -siphoning channel
to provide protection from severe weather
Figure 2 The 4 locations of Gulf Coast Supply.
d cost effective, but offers reflectivity so valuable
South. The paint system employed on painted
cts offers optimum exterior protection plus superior
resistance to corrosion and ultraviolet radiation.
While bare Galvalume carries a 25-year
limited coil manufacturer's finish warranty,
—►I T most painted metal carries a• 40-year war-
ranty. Both painted and unpainted are of the
highest known quality in the industry.
Gulf Coast also stocks a complete line of fasteners, sealants, and other accessories to meet
every need of both the do-it-yourself homeo er and the roofing contractor. A complete line of
both in -stock and custom-made flashings and trims are available in all colors as well.
( GULF RIB'"' DETAIL,MANUAL
'Installation of Panels
Roof Pitch
Gulf Coast roofing panels require a certain degree of pitch to ensure proper water drainage.
Florida Building Code allows a minimum pitch of 2/12 for Gulf Rib® panels as long as lap screws
and sealant are applied to the laps to prevent water from siphoning over the ribs (see Fig. S on p. 4).
Lap screws and sealant are optional when the pitch is 4/12 or greater (4/12 pitch means that there is 4
inches of rise for every 12 inches running horizontally). As a general principle, the less steep the roof,
and the more necessary also that sealant be used at all side -laps. Consult our representative for
recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12
pitch.
Roof Preparation
Oil -canning is a wave -like, rippled appearance extending up the length of the panel after it has
been installed on the roof. Any irregularities in the roof, including uneven plywood joints, warped
plywood, uneven trusses, poor application of underlayment, the use of button caps with felt paper, etc.,
can promote oil -canning. Care should be taken to provide a flat, uniform surface on which to attach
the panels. See page 6 for more details.
Roof Application
Panel installation should begin at the gable end of the roof opposite the prevailing rain -bearing
wind (this will provide added assurance against wind -driven rain being forced under the laps). Measure
one panel width in from the roof edge. At this point chalk a line from ridge to eave. Place the leading
edge of the first panel along this line. It is extremely important that this panel be laid square to the eave
and ridge so that the remaining panels will line up square on the roof frame. It is wise to have a person
at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof.
Also be sure that the panels are properly side -lapped (see fig. 7 on page 7).
In applications where end -lapping is necessary, the upper panel on the slope should lap over the
panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of
panel overlap. All end -lap applications should use two horizontal rows of butyl sealant tape across the
panel and proper fastening to.provide a maximum water seal.
An overhang of 2 to 3 inches on the eave is recommended to provide a drip edge, while only 1
inch overhang is necessary where gutters are used. The open panel ribs at the eave can be sealed with
inside closures. For maximum weather -tightness, a row of butyl tape can be applied above and beneath
closure material.
Trimming and Cutting Steel Panels
The best device for cutting steel panels across the profile is either hand snips or a nibbler.
Nibblers, and especially Carborundum blades on electric saws, however, do have a tendency to either
leave hot metal particles that can burn paint surfaces or to leave rust marks on panels and trim. The
same is true of any filings left on the roof caused by the application of screws. Care should be taken to
brush all such particles from roof surfaces after application.
To cut panels lengthwise: Note carefully where the panel is to be cut, and, using a straightedge,
score deeply down the length of the panel with a sharp -pointed utility knife. Folding the panel along the
score mark, and bending back again if necessary, should produce a clean break in the panel.
CAUTION! clean all metal shavings and particles off of roof to avoid unsightly rust stains
Residential Trim
Seep. 12 for Siding Trims
Endwall
;Gable trim Fp10
shing
(p 1) .)
Valley
(p—12)�
Sidewall 1\ \ W
-El 001�1
��\�%I
Roll Lite Door
i
isinon
fishing
(p.10)
Figure 4 Roofing trims and flashings are named by thfr
location or function of that particular piece on the buildi%g.
Panel lan detail
Gulf C'Woz R"t
SUPPLY & MANUFACTURING
Ridge cap
8)
Lap Screw Apply sealant
to lap
overlap♦
purlin-bearing leg J decking
Figure 5 Butyl tape or caulk is required when the
roof pitch is 3/12 or less, with lap screws applied
every 2 feet to maintain water -tightness of the lap.
On pitches greater than 3/12, lap screws and butyl
tape are optional. For more details on screws,
see pgs. 6 and 7.
GULF RIB"' DETAIL MANUAL
Ordering Roof Panels and Screws
Care should be taken to order panels of the correct length to avoid having to make
corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge when
a vented ridge is desired, and should extend 2 to 3 inches past the eave to allow a sufficient drip
edge (except as noted on pg. 3 concerning gutters). When a roof transition is involved, panels of
the upper portion should be ordered short to allow placement of the transition flashing (see
diagram on p. 10). The Gulf Coast sales personnel are ready to assist customers with information
specific to their particular'roof.
Specially-washered screws applied through the flat of the metal is the most recommended
method used to attach roofing panels. 1-inch screws can be used if penetration of only 3/4 inch is
either necessary or desired; otherwise, 1 % inch screws are usually recommended. 2% inch screws
are also available, and are often used by those who adhere to through -the -rib fastening, and for
ridge -cap application. See pages '6 and 7 for more information on screw spacing and ordering.
Ordering and Applying Trim
The most common flashing for metal roofing is the ridge cap, which is used at the peak of a
roof where two opposing roof slopes join. Other flashings include transition flashing, end wall
and sidewall flashings, and valleys (see diagram on right for application). Eave trims include
gable flashing and eave drip, either of which are often applied above fascia trim. When roof pitch
exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be mentioned when ordering
ridge caps, endwalls, and eave drip. When a steeper roof slope meets a lesser slope, both slopes
should be mentioned when ordering transition flashing.
At the gable edge the use of gable trim adds to the appearance of the structure and protects
the fly -rafter, and sidewall flashing is used where the side of a panel butts up against an adjacent
wall. In either case, the installer should be careful to seal between the gable rake or sidewall and
panel with butyl sealant tape, and to fasten the rake every 6" to 12" up the slope of the roof with
the appropriate screws. If eave drip is used on the gable, the number of 90 degree eave drip
should be specified separately from that used on the drip edge when ordering.
To prevent penetration of water, insects, and debris at the ridge, outside closures should be
inserted between the ridge cap and the top end of the panel. Screws are applied through the ridge
cap, closure, and rib in at least every other rib of the panels. At least a 1%" (or preferably 2%")
screw should be used for attaching ridge caps. Self -drilling lap screws can also be used to attach
ridge caps.
Keep Materials Dry!
Paint and finishes of Gulf Coast panels and trim are designed. to withstand severe rain and
wet weather conditions. Neither paint, galvanized, or Galvalume finishes, however, are designed to
be in continuous contact with water for long periods of time. Damage will result if uninstalled
panels or trim are allowed to remain wet in storage. Be sure to store material that will not be
installed immediately in a dry location. Wet material should be air-dried and re -stacked if
installation is not planned right away.
How to Figure and Apply Screws.
Gulf Coast Supply carries screws in 3 different li
inch, and 2 1/z inch. 1-inch screws will barely pe
11/2 inch are the best all-purpose size. I%- or 21/
necessary for attaching ridge caps. The table
used to figure approximate quantities of screws
spacings and sizes of roofs. For 2-foot spacing
screws, multiply the total linear feet of metal tim
Example: your order is 1250 feet of Gil
1250 x 2.7 = 3375 screws
Please confirm all estimates with your Gulf Coax,
you placed your order.
Codes allow re -roofing over shingles witho
provided the roof has been checked by a license(
Gulf Rib metal roofing can be separated fror
pine battens spaced on maximum 24"centers, or
direct contact between pressure treated lumbi
potential corrosion, Gulf Coast Supply sells on]
CAUTION: Battens must be fastened to the
minimum 8d common or pneumatic nails spaced
calculations according to ASCE 7-98). Battens
of ridge, eave, hip, valley, and gable -end trimi
For solid decking, at least 15/32-inch structur,
center is required.
If care is taken, metal roofing application cai
quickly and accurately into the desired spacing. ]
accurately in the proper locations on panels. Pw
For panel lap details, see Figure 5 on page 4
Gulf C
Delivery policy Delivery _charges apply to all orders
department for details.
Sales tax All orders picked up at Gulf Coast Supply,
state sales tax. Tax exemptions should be verified
Warrantied products A 40 year warranty applies to
warranty to Galvalume material. Ask for details..
Indemnity All prices and designs are subject to char.
Disclaimer While we have made every attempt at ac
printing, or technical errors.
gths: 1 inch, 11/2
.crate a 1 x4, but the
rich screws are
the right can be
various purlin
ween rows of
2.7
Rib roofing.
representative when
Gulf Coa'st
SUPPLY & MANUFACTURING
.Screw (Durlln) .SDacln
12 inch
18 inch
24 inch
50
270
180
135
100
540
360
270
200
1080
720
540
300
1620
1080
810
400
2160
1440
1080 -
500
2700
1800
.1350
600
3240
2160
1620
700
3780
2520
1890
800
4320
2880
2160
900
4860
3240
2430
1000
5400
:3600
2700
1100
5946
3960
2970
1200
6480
4320
3240
fF.igurel�6irG-uuIflR•ib�l screvl►
it the use of battens calculation chart
roofing contractor to insure levelness and pullout integrity.
i the moisture barrier by minimum, nominal 1 "x3" yellow
according to ASCE calculations where applicable. Since
r and metal roofing must be avoided in order to prevent
y untreated battens.
roof deck with minimum #6 screws at 12" on -center, or two
8" on -center, or one every 4" on -center (or by applicable
nust be installed to support the entire width and length
plywood supported on rafters at a maximum of 24" on
be aided by pre -drilling panels, allowing screws to go
•e-drilling will work provided that pilot holes are placed
in spacing must be uniform and carefully measured.
Policies
delivery is requested. Please consult your Gulf Coast sales
all orders delivered within the state of Florida, are subject to
r to delivery or customer pickup.
: material* manufactured from painted coil stock, and a 25-year
without notice
in this manual, we are not responsible for typographic,
OR Canning —a repeating, wave -like appearance in th ' length of the panel —is a common and often unavoidable
phenomenon in metal panels like Gulf Rib roofing that have large, flat areas within the panel. It is therefore not a
defect, nor a cause for rejection. See p. 3 for details) on how to avoid oil -canning.
Return policy All panel orders and special order (no; ,stock) trims are considered the property of the customer and non-
refundable once they are manufactured. Standard trun and accessories are refundable providing they are returned in a
clean, resalable condition. For details, go to www.gulfcoastsupply.com and click on "No Hassle Return Policy" at
bottom of page, or call Gulf Coast Supply to ask spocific questions about returns.
'11 RN ,
GulfC®ast
SUPPLY Q. MANUFACTURING
Gulf Coast Gulf Rib° Roofing Panels
Fastening Schedule for Various Wind Speeds — minimum 2:12 roof pitch
Wind Speed Zone
130 MPH
140 MPH
150 MPH
160 MPH
Roof
Fastener
Fastener Size
Attaching to:
On Center
On Center
On Center
On Center
Zone
Type
Spacing
Spacing
Spacing
Spacing
Zone 1
Woodgrip
or
#9-15 x 1'/�
min.15/32
24"
24"
24"
24"-
WoodZac ®
I Wood
plywood
Type l
yp
Type l
yp
Type l
yp
T e l
yP
Zone 2
Woodgripe
#9-15 x 1'/z
min.15/32
24"
24"
24"
24"
woodzace
plywood
Type 1
Type 1
Type 1
Type 2
Zone 3
Woodgrip®
#9-15 x 1'/z
min.15/32
24"
24"
24"
24"
Woodzace
plywood
Type 2
Type 2
Type 2
Type 2
Fastener pattern
Type 1 -
Type 2
Zone2 �a�*
Eave a
:......................... .........................................:...
.........................�........................................:...
-:---------------- Ridge ----------
---=--
Zone 1 viable
-'Zone 3
Genfef
OSPa�in
Fastener pattern
Fastener patterns Type 1 and Type
2 are shown at left, row spacings are
shown in the table above, and roof
zones are displayed on left below.
Figure 7 shows a simple illustration of
the patterns. Note that fastener pattern
Type 2 is required at top, bottom, and
end laps of each panel, as well as in
additional areas according to which
roof zone the fasteners fall in.
Each "zone" of the roof has its own
screw requirements. Dimension a is
defined as 10% of the minimum width
of the building, or 40% of the mean
height of the roof, whichever is
smaller; however, a cannot be less
than either 4% of the minimum width
of the building, or 3 feet.
Figure 7 Screws should be placed on both sides of the ribs at both eave and ridge, ca
and on the overlap side of any panel laps.
I Eave drip with fascia and inside closure
Figure 8 Eave drip and fascia give a finished look
eave of the house, as well as providing prot(
materials they cover. The eave drip should comple
top edge of the fascia. Inside closures, which seE
ribs of the panels, are optional.
Summary
E,
11'C'
` tNGu®as
SUPPLY & MANUFACTURING
Eave Drip
& Fascia
FHA Style
ED-3 Style
2 3/g"
Eave drip
Eave drip
7/ 16'
R
- R, • 'rx
T
For custom eave drip, specify the
Eave drip
amount of the eave that will be
along the drip
covered dimension "a"),and for
ction for the
.
steeper roofs, specify pitch . If
iely cover the
Fascia
a
fascia is desired, be sure that the
I off the open
1
dimension you order will be
—►i b �*_
hidden by the eave drip.
Stock Trims and Flashings
'al nrdnr infnrmatinn
Ridge caps (RC-2)
specify pitch if less than 3/12 or greater than 6/12. Also available in
larger widths. Cl 9 sures recommended.
Eave drip (FHA, ED-3)
2 common styles.1
FHA style is pre -pitched for 3/12 to 6/12 roofs. For
appearance or ease
of application, order by either specific pitch or as
gable trim (90°).
Gable flashings
Residential (EF-P,
large (GR-2), and small (GR-1) rakes available. Use
butyl sealant between
rake and panel.
Valleys (PV 1)
specify pitch if greater
than 7/12. Seal with universal foam closure
material. Open -hemmed
valleys (PV 2) aid water -tightness.
Sidewall (SW-1)
Use butyl sealant
between sidewall flashing and panel.
Endwall (EW-1)
Specify pitch if g
eater than 5/12. Seal with outside closures.
Transition flashing
Specify pitches o� both roofs. Seal lower slope using outside closures and,
if desired, inside closures on upper slope.
C=GULF RIB"' DETAIL MANUAL
Ridge Cap loo.
The Ridge Cap is used to seal the point at
which two upward slopes meet. This can
be both along the ridge of the roof as well
as a covering for a hip. Either woodgrip
or self -drilling lap TEK screws are
applied through the ribs of the metal..
Since debris, insects, and blowing
rain can find easy access under the ridge
cap, closures are required to either
completely or partially seal the opening.
Closures under ridge caps come in 3
types: solid, vented, and hip tape. Figure 9
Solid closures ("Outside Closures") are (right).
the same width as the panels. They lock together in a row placed directly
under the screws that attach the ridge cap, and form a solid, water -tight,
air -tight barrier.
Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water -
retardant, insect resistant barrier that allows hot air to escape from the
attic, and is superior to many more elaborate and expensive vent systems.
Any length maybe ordered.
Hip closure tape (Peel and Seal is a sticky, adhesive -backed metallic tape
that seals the hip roof. It is 6 inches wide and comes in 33'/z foot rolls.
Because it must be conformed to the rise and fall of the panel ridges,
approximately 10% extra may be needed beyond the length of the hip
being covered.
Outside 6„ /� Profile Vent®
closure or Versa -Vent®
J
`Lap or 2'/z" Woodgrip iw
screw required
RC-2 Standard 12-inch Ridge Caps
are strong, economical and adequate for most of your roofing needs
6"�
RC-1 style 12-inch Ridge Caps
are also available in custom widths
Ridge cap showing outside closure (left) and profile vent
Figure 10 Pipe.Boots provide a
water -tight seal around roof
vents and come in a variety of
sizes. They seal with caulk and
conform to the shape of the
panel ribs.
a�
RC-2 style over -sized ridge caps
are available with 18-inch coverage, or as a custom trim
item in total widths (2 times "a") of 14-, 16-, 18-, 20-,
22-, and 24-inch
'0 ..
GuIX&M'
SUPPLY & MANUFACTURING
® End -Wall Flashing
End -wall flashing is applied where the upward
slope of a roof meets a wall. The wall side of
the flashing can be covered with siding or
counter -flashing, and outside closures are
recommendedd))
necessary to seal
caulk (Solar between t h e
flashing and the
caulk edge (order EW-1C)
3 �� (used if endwall not panel. Roof slope
covered by siding) s h o u l d b e
mentioned if roof
\32'�y exceeds 5/12
pitch.
Figure 11 As with the ridge cap, the ENI
FLASHING above is sealed using outside closures.
EW-1 Stepped Hemmed
Use EW-2 hemmed endwall when cornering endwalls with lidewall b Endwall b EW-2 E dwall
flashing, such as with dormers or chimneys.
For custom end -walls, specify roofpitch and dimensions "a' and "b". �aZ/ 1 � _a a = 4%z"
\y b=3"
Transition Flashing jo,
The TRANSITION FLASHING prevents
leakage at the point where two different roof
pitches meet. It must be sealed on the lower
side with outside closures, and can be sealed
underneath the upper panels with inside
closures. The similar GAMBREL
FLASHING is used where the lower pitch is
steeper than the upper.
TF-1 Transition Flashing
closure -.
For custom transition flashing specify the pitches
of the two roof slopes and, if necessary, dimensions
"a" and "b".
Figure 12 The transition flashing
(above) and the GF-1 gambrel
flashing (right) provide a
continuous drainage where two
slopes meet. Both seal with
outside closures on the lower side.
Gable Flashing Ooo,,
I
EF-1 style
Custom trim —specify a custom R
length for a or b.
Standard dimensions — a = 3"
b=3"'
GR-1 style
Custom trim —specify a custom
length for a or b. b
Standard dimensions — a = 2 N
b = 21/8
GW06 t
SUPPLY & MANUFACTURING
tew o - ga a trim ascia oar rea+ove
Figure 14 Sidewall flashing is applied when the side of the
roof butts up against an adjacent wall. The wall -side of the
flashing can either be covered over with siding or sealed
with caulk (order SW -IC). Butyl tape should be applied
where the "foot" of the flashing attaches to the roof.
Figure 13 Gable flashing is used to trim the edge of the
roofing panel at the gable end of the roof. It should match
the eave drip that extends along the drip edge of the roof. If
the panel is allowed to hang over the gable end, eave drip
can be used instead. Butyl tape between the trim and
panel eliminates leaks.
® Side -wall Flashing
caulk (Solar SeaP recommended)
caulk edge (order SW-1C)
(used if sidewall not
covered by siding)
.� I1
-311 Butyl tape
y
3/4" Alk.
s1
SW-1
Custom trim ---specify a custom
length for a or b.
Standard dimensions — a = 3"
b=3"
Preformed
Valley
Install panels 2 to 4"
from diverter 7�
* 1"
PV 1 style a —>
PV 2 style
Two basic styles of valley are available.
For custom valleys, specify dimension "a"
Gulfco6ft
SUPPLY & MANUFACTURING
o
-o
0
o
o.
a" .
o
0
Figure 15 Pre -formed valleys use a diverterto prevent water
from rushing under panels on the opposite side, while
meanwhile channeling water off the roof. -Expanding foam
closures are often used to assure a good seal.
Gulf Coast Gulf Rib® Sliding
e &
1.13
OW
Sliding
KIN, Door
,-
'
Base Drip
(p.14)
T' Trai
Cover (p',
Figure 16 Common
trims as, ociated with Gulf
Rib roofing panels
r�
GULF RIB'" DETAIL'MANUAL
GR-2 Outside Corner loo,
The GR-2 Rake and Comer can be used as a
gable trim or a corner for metal -sided buildings.
As an alternative, the smaller EF-1 or the GR-1
(both on p. 11) can also used as gable rakes, and the
PC-5 (below)or the GR-1 as corners.
Customizing rakes or corners is often necessary
due to their landing on a panel rib. Both the GR-2
and the IS-2 can be ordered as custom trim items
by specifying custom dimensions "a" or "b". Be
sure to take into account the 3/4" "head space" when
figuring custom dimensions.
1
3
The PC-5 flat corner
works best on smaller
structures, and where
the panels are running
horizontally. It can be
sealed with outside
closures.
Figure 17 When used as corner trim, the GR-2 straddles the ribs
of the panels where they meet at the corner of the building. The
Gulf Rib outside corner also serves as a gable rake (see below).
The inside corner (IS-2) has similar dimensions but with a
reverse middle bend.
® GR-2 Gable Rake
bL
Figure 18 When used as a gable rake, the GR-2 runs parallel to the ribs of
the roof panel, and is attached with screws running through the ribs of
upright siding. As with the EF-1 residential rake, the roof side can be
sealed with butyl sealant.
4 sis"
C.
1
drep cap
I
chan►�l
i
Figure 99 The drip cap is commonly used to triml out the bottoms of panels
over doorways and windows, and occasionally takes the place of base drip.
J-channel is used to cap raw panel edges where ryn-off is not a problem, and
is most commonly used to trim around the bottom, sides, and occasionally�the
top of windows and doors, and also to cap the top sides of skirting.
Base Drip
POP-
BD-l'.-
Base drip
71�11
1'/4"
G 6 li'CWoa s't
SUPPLY & MANUFACTURING
Drip Cap and
®
Jnn -C a e h i
i/
DC-1
Drip cap
capping the panel end
® JC-1
J-channel
panel 7/s"
2,/4L---�
capping Lthe panel edge
Figure 20 Base drip seals off the bottoms of panels at the floor level, where
it helps to prevent the entrance of rodents and insects, as well as a base for
the setting of panels.
�,GULFRI-B`DETAILMANIUAL
Gutters 10,
Gulf Coast Supply produces 29-, 26-, and 24-
gauge gutters in either 5- or 6-inch widths (depth is
approximately equal to width). All gutters
should be ordered specific to the pitch of the
roof. Downspouts are available in Yx4" (for 5-
inch gutters) and 4"x4" (for larger gutters). End
caps should be ordered at the same time as the
gutters to assure a custom fit. Special hangers fit
into the panel rib and under the gutter lip. Panels
should extend no more than 1" to 1'/z" inches
beyond the cave on which gutters are planned.
' lap
�-5 or 6"--►
1 Gutter hangers fit inside
panel rib and under lip
of gutter (apply at least
one per panel) and are
attached with lap screws
or rivets.
Figure 21 Exposed view of gutter showing gutter hanger
placement, downspouts, and end caps. Hangers employ lap
screws, and end caps are best attached with rivets.
Oute� r Inner, =; °Q;uter` ; - Inner Out(
Inner and outer gutter sections (marked `I" and "O')
alternate along the eave to assure ease of application and
gutter appearance.
Downspouts in excess of 10 feet in length must
be made in 2 sections.
® Track Covers
TC-1
sliding door
track cover
Figure 22 Sliding door track covers fit over the door track and
under the panels to hide the track, assure a neat appearance, and
shed water over the door.
Gulf Cast
SUPPLY & MANUFACTURING
Ridge caps (pg. 9)
Eave drip (pg. 8)
Valleys (pg. 12)
Gable rakes (pg. 11)
Wall 10hlls
flashingsn(pg 10) re
Corner trims (pg. 13)
Door & window_
trims (pg. 14)
Base drip (pg. 14)
pipe Boot (pg. I )
Electrical Boot
Reflective bubble
insulation
Inside Closures
,Y y
Outside Closures
®
Flex-o-vent
®
Profile Yent
Expanding
Foam
®
Peel and Seal
y
Touch-up Paint
t
S/D TEK Lap TEK
Butyl Tape
Titebond®
Woodgrip
Screws
TEK screws
WoodZaco screws
WoodMac screws
Guide tol Misc. Accessories
item
application
pipe boot
Fits over vent and
heat pipes. Available also in heat -resistant boots.
electrical boot
Fits around pipes
with inaccessible tops (such as weatherheads)._
outside closures
Required to seal under
ridge caps and transition and endwall flashings.
inside closures
Seals .under panels
particularly on the eave.
Profile Vent,, Flex-o-Vent® Vented closure material
surpassing many other venting systems.
expanding "foam
Compressed adhesive
foam expands to seal between valleys and panels.
Peel and Seal®
Seals hips under hi
caps. Also, a general purpose sealing tape (6" wide).
touch-up paint
Hides scratches and
mars encountered in installation. Over 20 colors.
butyl tape
General purpose low-cost
sealant, used on panel laps and under trim.
Titebonde
A superior general urpose caulk for alljoints: Matches panel_colors.
Low profile insulation
Greatly reduces radiant_ heat when installed under panels.
Woodgrip screws
Used in all applications attaching metal to.wood. 11, 1%11 2%11 sizes.
TEK screws
Self -drilling TEK screws for metal purlins. Lap TEK screws draw
together joints and attach trim.
ZAC® screws
"Lifetime" screws; %999 2V2", threaded for wood; self -drilling available.
Version 01-26-16