HomeMy WebLinkAboutSPECIFICATIONS & DESIGNTABLE OF ROOF BEAK z,COLUMNS, PURLINS Aj'_ GIRTS: 'THIS POLY ROOF STRUCTURE MEETS THE FLORIDA BLDG. CODE FOR A HEIGHT 8'-0", EXP. 'C', 150 MPH WIND SPEED. THE TABLES BELOW ARE BASED ON SIMULTANEOUS LOADING AS DEFINED IN THE FLORIDA BUILDING CODE (FBC), CHAPTERS 16 AND 20, AND OTHER REFERENCES SUCH AS ALUMINUM ASSOCIATION OF-FLORIDA (AAF)-"GUIDELINES-TO-ALUMINUM CONSTRUCTION IN HIGH WIND AREAS". STRUCTURAL VALUES FOR EXTRUDED ALLOY 6005T5 ARE TAKEN FROM THE ALUMINUM DESIGN MANUAL, 2015 EDITION. TABLE 1 MAIN ROOF MEMBER SCHEDULE MEMBER MARK MANF. WEIGHT ATERIA THICKNESS LENGTH DESIGN BASIS # I SKIN I POLY I SKIN FT. I FL. PROD. APPR. POLY ROOF PANEL # 1 PRP1 I ELITE 1 1 1 ALUM 1 3" 0.024 11'-0 )tl5614; DWG TABLE 2 MAIN MEMBER SCHEDULE MEMBER MARK SIZE I MATERIALl TYPE I THICKNESS LENGTH DESIGN BASIS b x t I ALLOY IN I F I FT. COLUMN # 1 COLUMN # 2 CARRIER BEAM # 1 EDGE BEAM # 1 KNEE BRACE # 1 Cl 3x3-9 ALUM TUBE 0.090 0.090 8'-0" CALCULATION C2 3x3-9 ALUM TUBE 0.090 0.090 8'-5" CALCULATION CBI 2x3-9 ALUM HOLLOW 0.090 0.090 8'-0" CALCULATION EB1 2x3H ALUM HOLLOW 0.090 0.090 10'-0" CALCULATION KB1 2x2-12 ALUM HOLLOW 0.046 0.046 1'-5" • CALCULATION NOTE:. AVERAGE ADDITIONAL SITE SPECIFIC INFORMATION THIS POLY ROOF COVERED AREA IS LOCATED IN A RESIDENTIAL COMMUNITY NORTH OF SE WALTON ROAD AND EAST OF U.S. ROUTE 1 IN PORT ST. LUCIE. THE COVERED AREA HAS SOME OPEN AREAS AROUND IT. THE ENCLOSURE IS VERY CLOSE TO THE SAVANNAS PRESERVE STATE PARK. PER THE EXPOSURE CATEGORIES LISTED IN SECTION 1609.4.3 OF THE FLORIDA BUILDING CODE THIS ENCLOSURE SHALL CONSERVATIVELY BE CALLED AN EXPOSURE 'C'. ACCORDING TO THE COMPUTER PROGRAM "WINDSPEED BY LOCATION", A PRODUCT OF -APPLIED TECHNOLOGY COUNCIL' THE DESIGN WIND LOAD REQUIREMENTS FOR A RISK CATEGORY I ENCLOSURE IN THIS LOCATION IS DICTATED BY A WIND SPEED OF 148 MPH. HENCE, THE DESIGN PARAMETERS BEING USED HERE ARE 150 MPH WIND LOAD, EXPOSURE 'C', RISK CATEGORY 1. THE NEW POLY ROOF COVERED AREA IS BEING INSTALLED BECAUSE THE EXISTING NOMINAL 4" SLAB THAT IS GOOD CONDITION. THE FRONT IS V-0" HIGH AND THE REAR IS 8'-5" HIGH; WITH A RUN OF 10 FEET GIVES A SLOPE OF ABOUT 0.50 INCHES PER FOOT. THIS FOUNDATION IS ACCEPTABLE FOR THIS SCREEN ENCLOSURE. THE DESIGN DRAWING IS SHOWN ON SHEET 2. THE POLY ROOF CONNECTION DRAWINGS ARE SHOWN ON SHEET 3. THE HOST STRUCTURE IS A MODULAR HOME SO 4TH WALL CONSTRUCTION FOR COMPOSITE ROOFS WILL BE USED. THEREFORE, THE COLUMNS, BRACING AND CONNECTIONS SHOWN ON SHEET 2 ARE THE SAME IN THE BACK AS IN THE FRONT EXCEPT THAT THE BACK IS 9 INCHES HIGHER. THERE SHALL BE NO STRUCTURAL ATTACHMENT BETWEEN THE POLY ROOF COVERED AREA AND THE MOBILE HOME BUT IT IS ACCEPTABLE TO INSTALL FLASHING TO KEEP THE RAIN OUT. THE CARRIER BEAM TO COLUMN CONNECTION CAN BE MADE WITH 7" LONG CHANNELS AND FOURTEEN (14) #12 SMS, SEVEN (7) BETWEEN EACH CHANNEL AND COLUMN AND SEVEN (7) BETWEEN EACH CHANNEL AND CARRIER BEAM, SIMILAR TO KNEE BRACE CONNECTIONS ON SHEET 2. ALSO, SEE OPTIONAL CONNECTION DRAWINGS BETWEEN COLUMNS AND CARRIER BEAMS BELOW. SPECIFICATION NOTES AND DESIGNaj4RAMETERS: 1 THIS DESIGN COMPLIES WITH THE GUIDELINES DEFINED IN CHAPTERS 16 & 20 OF THE 2017 FLORIDA BUILDING CODE, SIXTH EDITION, BUILDING, USING THE ALLOWABLE STRESS DESIGN PRESSURES LISTED IN TABLE 2002.4 AND TABLE 2002.4A. THE AAF STANDARDS OF THE "GUIDELINES TO ALUMINUM CONSTRUCTION IN HIGH WIND AREAS" FOR THE TABLES ARE APPLIED. A DESIGN BASICS: THIS POLY ROOF COVERED AREA IS A RISK CATEGORY I STRUCT HEIGHT 8'-0", EXP. 'C', 150 MPH B THE BUILDING CLASSIFICATION RISK CATEGORIES ARE FROM FBC, TABLE 1604.5 AND AREA LOCATION WIND SPEED PER FBC, FIGURE 1609C. BUILDING CLASSIFICATION PER TABLE 27.2-1, ASCE 7-10. C DESIGN PRESSURE: FOR SOLID ROOF @ 30.96 PSF PER TABLE 2002.4. D MAXIMUM HEIGHT: HEIGHTS HIGHER THAN LISTED ABOVE REQUIRE SITE -SPECIFIC DESIGN BY THE ENGINEER OF RECORD. E ALLOWABLE DEFLECTION: L 160 MINIMUM, AS SPECIFIED IN TABLE #1604.3 OF FBC. R1 F CONTINUOUS LOAD PATH IS PROVIDED WITHIN THE CALCULATIONS USING ALLOWABLE STRESS DESIGN PRESSURES. R1 MATERIALS (UNLESS OTHERWISE SPECIFIED BY THE ENGINEER OF RECORD): A ALL EXTRUSION MATERIALS SHALL BE ALUMINUM ALLOY # 6005T5 OR # 6061T6; ALLOY # 6063T6 IS NOT ACCEPTABLE. B FASTENERS: ALUMINUM ALLOYS #2024-T4 & #7075-T6, DOUBLE CAD -PLATED STEEL, HOT -DIPPED GALVANIZED STEEL OR 300-SERIES STAINLESS STEEL. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE FOR SEPARATION OF DISSIMILAR MATERIALS AS DEFINED IN THE FBC. HE/SHE MAY IMPLEMENT ANY OF THE MEANS LISTED IN THESES TIO ALTERNATIVES MUST BE REVIEWED AND APPROVED IN WRITING BY THE ENGINEER OF RECORD PRIOR TO ANY INSTALLATIONS UTILIZING THE SUBJECT METHODS. ST. C SCREEN CLOTH: SHALL BE VINYL -COATED, WOVEN FIBERGLASS, MAXIMUM DENSITY OF 18 X 14, 58% OPEN MINIMUM. OTHER SCREEN DENSITY REQUIRE ADDITIONAL ENGINEERING CONSIDERATION. D ANY CONNECTION USED, THAT IS NOT SHOWN ON THESE SHEETS, MUST MEET ALL FBC AND AAF GUIDELINES. E MATERIAL UPGRADES (STRONGER AND/OR HIGHER GRADE MATERIALS) CAN BE SUBSTITUTED AT ANY TIME. F A 2x2 OR A 2x3 SNAP MEMBER CAN ALWAYS REPLACE A 2x2 OR A 2x3 HOLLOW MEMBER, RESPECTIVELY. G WHEREVER SCREENING OR KICKPLATES ABUTS THE HOUSE OR CONCRETE THE MEMBER USED TO SUPPORT THAT SCREENING OR KICKPLATE WILL BE A I" x 2" x 0.046" O.B. OR STRONGER ALUMINUM MEMBER. H ALL DOOR JAMS (DJ) SHALL BE 2" x 2" x 0.046" ALUMINUM MEMBERS OR STRONGER. 1 IT IS ALWAYS ACCEPTABLE TO ADD OR RELOCATE A SCREEN DOOR AS LONG AS THE COLUMNS ARE NOT DISTURBED. . is FEB Lucie 3 ALL HOUSE FASCIA DETAILS, BOLTING OR SCREW SELECTIONS, BEAM SPLICE DETAILS, DIAGONAL "K" BRACING DETAILS, COLUMN TO BEAM DETAILS, STRUCTURAL GUTTER DETAILS, WALL AND FASCIA DETAILS, CORNER ANCHOR DETAILS, ROOF BRACING DETAILS, EAVE BRACING DETAILS, ETC., IF NOT EXPLICITLY OUTLINED ON THIS SPECIFICATION, SHALL BE IN ACCORDANCE WITH THE LATEST FBC EDITION, INCLUDING THE AAF. ALL INTERNAL CONNECTIONS SHALL MEET THE FBC (AAF) AND THERE INSTALLATION ARE THE RESPONSIBILITY OF THE CONTRACTOR. 4 WHERE APPLICABLE, THE LOCATION OF ALL "K" BRACING, WIND BRACING, EAVE RAILS AND CHAIR RAILS, ALONG WITH ANY DESIGN ABNORMALITY, ARE SHOWN AND/OR LISTED ON SHEET 2, THE "SITE SPECIFIC DRAWING". 5 ALL STRUCTURES ERECTED ON CONCRETE SLABS AND / OR FOOTERS SHALL BE CALCULATED FOR SUFFICIENT HOLD DOWN CAPABILITY TO MEET THE CODE REQUIREMENTS. ALSO, ALL TAPCONS, WEDGE ANCHORS (OR EQUAL) SHALL BE 24" O.C. (MIN.), BE 3" FROM THE EDGE OF THE SLAB AND HAVE A MINIMUM EMBEDMENT OF 2" INTO THE CONCRETE SURFACE. 6 THE AVERAGE SPACING BETWEEN BEAMS IS SHOWN ON THE "SITE SPECIFIC DRAWING". THE ACTUAL SPACING BETWEEN ANY TWO BEAMS MUST BE THE LISTED SPACING, +/- 2". THE OVERALL AVERAGE SPACING MUST BE EQUAL TO THE AVERAGE SPACING SHOWN ON THE "SITE SPECIFIC DRAWING". 7 IN LIEU OF "SITE SPECIFIC ENGINEERING" AN EXISTING SLAB SHALL MEET THE FOLLOWING REQUIREMENTS: A THE SLAB MUST BE IN GOOD CONDITION, 4" OR GREATER THICKNESS, CONSTRUCTED WITH REBAR, WIRE OR FIBER MESH. B ALL HOLD DOWN FASTENERS MUST BE NO MORE THAN ZV ON CENTER WITH MINIMUM ENGAGEMENT OF 2". 8 ALL NEW SLABS, WITH OR WITHOUT FOOTERS, SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, B 4" NOMINAL PATIO SLAB REQUIRES A VAPOR BARRIER IF THE SLAB ABUTS LIVING QUARTERS, C 4" NOMINAL PATIO SLAB WITH CONCRETE @ 3006 PSI (MIN.) WITH FIBER MESH OR REBAR AND WIRE, D SHALL BE SECURED TO EXISTING CONCRETE WITH #5 REBAR EVERY 24" O.C. TO AVOID SETTLEMENT, IF APPLICABLE. POLY ROOF COVERED AREA DWG. # RVC-2018-111, REV. 1 February 20, 2018 SHEET 1 OF 3 GENERIC DESIGN DATA HEIGHT 8'-0", EXP. 'C', 150 MPH R V CONSTRUCTION BRINA CIRCLE T ST. UCIE, FL 34952 OFFICE (7 ) 380-8253 gIpgNSE # RC 1330965 LOCATION: NAME: STINSON RESIDENCE ADDRESS: 7646 BARN OWL DRIVE CITY/STATE: PORT ST. LUCIE FL 34952 COUNTY: ST. LUCIE REVISION UPDATED THE PRODUCT 'ROVAL FOR THE POLY ROOF ELS. SEE SHADED AREA. ONLY ET 1 IS AFFECTED. THIS DRAWING IS ONLY ACCEPTABLE FOR BUILDING PERMITS & ONLY WHEN IT HAS THE ENGINEER OF RECORD'S RAISED SEAL. COPIES ARE NOT DEEMED VALID. THIS DOCUMENT IS THE PROPERTY OF R. A. DUNLEA, P.E. AND SHALL NOT BE REPRODUCED IN WHOLE OR IN PART WITHOUT THE WRITTEN CONSENT OF R. A. DUNLEA. R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(a)-centurvlink.net FLORIDA P.E. Lic. No. 42835 9 ALL NEW PERIMETER FOOTERS SHALL MEET THE FOLLOWING REQUIREMENTS AS A MINIMUM: ee�0,xv- HOIyy'�.,� A SOIL MUST BE WELL COMPACTED AND TREATED FOR TERMITES PER COUNTY REQUIREMENTS, �����(�® �''�� Q't •••... ••• QG O� B CONCRETE @ 3000 PSI (MIN.) WITH ONE #5 REBAR FOR 8" x 8" AND TWO #5 REBAR FOR LARGER FOOTERS. SCANNED V ;� �� . •• �fi �� Y • (3b Lucie a t m . 10 ALL NEW PERIMETER FOOTER POURED WITH A SLAB SHALL MEET THE FOLLOWING CONDITIONS: t Luc� : O. • A PERIMETER FOOTER AND THE SLAB SHALL BE MONOLITHICALLY POURED, i * • B ALL REQUIREMENTS OF ITEMS 8 AND 9 ABOVE. e -0 : ; '0� ATE F ;•�4 11 ALUMINUM IN CONTACT WITH CONCRETE OR MASONRY SHALL BE PROTECTED WITH AN ALKALI RESISTANT COATING. �i(� •, p. •••••• THIS NG COVES ONLY THE ITEMS LISTED IN THE TITLE BOX. ANY OTHER TASK, SUCH AS ELEC 12 PLUMBNG,IE C, SHALL BE BY OTHERS AND SHALL BE COVERED BY A SEPARATE DESIGN DOCUMENT.TRICAL, ooes�oniA a MOBILE HOME SITE SPECIFIC DRAWING r I 8'-5" I MOBILE HOME ____,__---3x3 POST C2 MOBILE HOME 9'- 10'-0" 3 B" LEFT SIDE ELEVATION VIEW KNEE BRACE DETAIL will, �G <-COLUMN PER TABLE 2 CHANNEL U TOTAL FOUR 2x3XO.O70, BACK END a z sons MITERED W/ 118" 12" N U-CLIP, SIX (6) #12 SMS INTO COLUMN / CARRY BEAM, THREE (3) #12 SMS INTO EACH SIDE OF KNEE BRACE (TYP.) ■ CHANNEL NOTE: KNEE BRACES SHALL BE 2x3x0.070 MEMBERS AND SHALL BE 1'-5" LONG. EACH END SHALL BE CUT ON A 450 ANGLE. THIS ALLOWS FOR EACH END TO BE 1'-0" FROM THE CORNER. NOTE: THE KNEE BRACES (KBI WILL BE ATTACHED TO THE COLUMNS AND CARRIER BEAMS USING A 2"x2.25"x2"x0.125" THICK CHANNEL AS SEEN ABOVE. THERE WILL BE SIX (6) #12 SMS BETWEEN THE COLUMN AND THE CHANNEL AND BETWEEN THE CARRIER BEAM AND THE CHANNEL AND BETWEEN THE BRACE AND THE CHANNEL, 3 ON EACH SIDE, AT EACH END OF THE KNEE BRACE. A TOTAL OF TWENTY-FOUR (24) SCREWS FOR EACH KNEE BRACE. TWO (2) 3/8" BOLTS CAN BE USED FOR EACH SIX SCREW CONNECTION. 3" 7'-9" 'E: THERE WILL BE KNEE BRACES BETWEEN THE FRONT AND BACK EDGE JVIS AND THE COLUMNS, ON THE RIGHT SIDE, SAME AS THE LEFT SIDE: VATION VIEW BETWEEN THE RIGHT SIDE COLUMNS AND THE EDGE BEAM. THI EDGE BEAM SHALL BE SECURED TO THE FRONT AND BACK COLUMNS USING NNELS AS SHOWN BELOW AND ATTACHED TO THE UNDERSIDE OF THE POLY )F WITH #12 SMS, 3" LONG, STARTING 6" FROM EACH EDGE AND EVERY 12" ,THEREAFTER. _: THERE SHALL BE NO STRUCTURAL ATTACHMENT BETWEEN THE COLUMNS THE MODULAR HOME AND BETWEEN THE POLY ROOF AND THE MODULAR E. IT IS ACCEPTABLE TO INSTALL FLASHING BETWEEN THE MODULAR HOME F AND THE POLY ROOF OR CARRIER BEAM TO KEEP THE RAIN OUT. E: THE BACK WALL IS THE SAME AS THE FRONT WALL WITH RESPECT TO CARRIER BEAMS EXCEPT THESE ITEMS ARE 6" HIGHER.. E: THERE ARE A TOTAL OF FOUR (4) KNEE BRACES USED HERE; ONE NEEN EACH COLUMN AND THE ASSOCIATED EDGE BEAM. nTF: THE KNFF RRACF.S_ KR_ RHAI 1 RF 9Y3Y0_(170 MFMRFRR- CIIT AN A ASO NGLE AT EACH END WITH THE SHORTER SIDES AT 16" LONG AND THE LONGER IDES AT 18" LONG. SEE SKETCH BELOW. AN ALUMINUM CHANNEL, 2 x 2.25 x 2 0.125" THICK, SHALL BE ATTACHED TO THE COLUMNS, EDGE BEAM MEMBERS r EACH -END OF THE KNEE- BRACE AND SECURED TO THE COLUMN AND-EB SIX (6 12 SMS. THE KNEE BRACE WILL BE INSERTED INTO THE CHANNEL AND SECUREI 'ITH SIX (6) #12 SMS, THREE (3) ON EACH SIDE OF THE CHANNEL. THE CHANNELS HALL BE 6" LONG AND THE NEARER EDGE SHALL BE 24" FROM THE CORNERS. 18" KNEE BRACE 16" 3" -1 LB. POLY ROOF w/ 0.024" SKIN UP TO 12" OVERHANG ALL AROUND 10'-0" PLAN VIEW FRONT ELEVATION VIEW E X I S T 1 N G M O B I L E H O M E E X I S T I N G M O B 1 L E H O M E POLY ROOF COVERED AREA DWG. # RVC-2018-111, REV. 0 January'17, 2018 SHEET 2 OF 3 SITE DESIGN DRAWING HEIGHT 8'-0", EXP.'C',150 MPH R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NAME: STINSON RESIDENCE ADDRESS: 7646 BARN OWL DRIVE CITY/STATE: PORT ST. LUCIE FL 34952 COUNTY: ST. LUCIE DRAWINGS NOT TO SCALE R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(W-centurviink.net FLORIDA P.E. Lic. No. 42835 Pe1tHONy A TLORVA AP U RU�r Ai t ON N E' 1 !! C. o v QN-70 sTi� cru�E: FRON ► ELEVA i E ON SECTION AT BEARING <_ .:_ WOOD: tOR :C01�1.CRETE � �y,_ COLUMN .. >: -^=; P=SEE GENERAL NGa c=t O FOR; If D Il lGN = � =ESj IOU 'i71G isOLT 1D' O.Cti •& ENDST0.2' SOUND = _ _OtNUCU= 1474 iCOFCj _',' Eg a`X FASGlA:IS'SGIRELY FASTENED SO r� _ c'NS'JRE..; 3' OZ4' �:,t:LF.1 � -°:_ =rrii iv;:-rFii`wiiH•i'-.�?'+':LAGrLN•. C .;0 @its.EiVSURE.i "rIIN:P�►�c"_ mriOPt- ecrvl7reTE A�rflaiG #1?>C%"SMS@ PRE-DRII1, HOE_ TO �AUOID SPLtTING OR F21 I Kn SEALED TJ MASONRY* -1 p wA- lei P) _ EI�Ti E ORR 56A4FBR %'x='i{ EMBED.: /EP-73 3 TAPCON @ 2 }j•' &4h'.FROM - ' ENDS SAL @ iB^ U j MAX O.C.« 2- NOMINAL STRUCTURAL, !� FACIA MINimUM EP-73 �14AV SMS @ 7' O.C. (9) PEP_ 4' PANEL TOP R "NOTE: USE 1" EL 4$ EMBED ° TAPCONS, Z 4}�' FROM ENDS, BO (TOM ADD (2) SHS 2 $ 4' FFiOPd EACH 114'MAX O.C. TO HOLLOW BLOCK ENCLOSURE ENO TOP EL BOTTOM. HEAVY ADHESIVE CAULK TOP & BOTTOM CONTINUOUS rN.C.LOZURi� T 0 CONCRETE uECK /1fVL,l 7 t7 Fc�FbL7 lr`Ji� 1 ii LL *SEE GENERAL NOTE �iO FOR ATION COLUMN -PER. TASLr-S Gk 3'Sc3'x3"-%' ANGLE WITH (Z) %-3a4ii' EMBED. SEALED SITE SPECIFIC TAPCONS W/ W MRi. WASHER DIAMETER TD DRAWINGSl,=ALCULATIONS SLAB, Z%' APART & 3' FROM SLAB EDGE & (6) �14 SMS TO COLUMN, %1 FROM ANGLE EDGES, ONLY EACH SIDE OF COLUMN Ov � O .a - a M(_W�AG CONi.REi E SLAB & FOOTING. SEE SITE SPEMFIC RETAD_C� ADDTiICSRLFOOTING E GINEEP.ING SHEET .EAVE BEAM CONNECTION @ WALL SEE GENERAL NOT. #10 FOR OMIT TIC EPSPO`Y _ (USED AS REQURIED WHET �� CONNECTING TO WALL) 3/a THRLIBOLTTHRDUGH 2"s3'A' ANGL r TO ROOF, T n o g• 3w• ANGLE FASTENED TO INSIDE & r:. u BOTTOM °JF CARRY BEAM W/ (Z) _ Lz-� THRU3OL-1S SIDE, (5) Y14smr; BOTTOM, i- - •tALLg_OR- APES FASTENED TO S WALL W/ (Z) Vi X3%/V EMBED TAPCONS OR TO WOOD (MIN �, OTHERS) W__ H rTOP t � rP 3cTrcr-T) D97' I SEETABLE.BELDW ;ifdEitlSlOf,�S:?+73�1 ':oE?aiGN r To. P, - SEQ � ;E.PL rTJP DTCdEMSOMs BOX = ^irCa{(;TFfO�E S: �tCI=iED ,.; BEAM I --44 AL EXTRUSIb- KS'TO BE rJI E3 a x VARIES " UP BEAR ,P. , 1 SNAP I cE=A1 TOP SY"- SCt:APE': c.� 3' - � �41 ' , rq•I.D{sal •-. ' Z12c;_; .. I.134a .DSD I • ilT7 S'rfow.lP4 I •� % .z379�.D72' _.--r _� Z'� 71a III.a7-e'� ?3^ 5QU?rr-7_z0° 5 Zx1D .33G�.Daa'i SECT?ON .`=,! �`Ai�t_' NG COLUMN (OPT-) v• v; LAG'-P.�NC- TAnLc )I- & E40 1 IOO-B 110 B I. 18 11' O.c .i2, Q.G ?0PER ?r1liEL :ja B plo C 30 P� �° O.L i0' O.C. 1=D C (7� PAIyH. a j0 C 1397 4 � _4 ANEL 150 C ' -s12�4° SKIS a i YP. top a B�TOM 'X L = INAL RL= ROOF LOAD LOAD OPTION is USE Y&' I� BOLTS Ji W/ i- J m. WASHER DIAMETER, 1° pm. LONGER THAN PANEL I G4RRY BEAM PER TASLES OR L OR4NRNCrFE SPECIFIC BOTH OPTIONS: (2) %' THRLISOLTS, : THICKNESS SPACED PER LAG CARRY BEAM-1-0 COLUMN SPACING TABLE THIS 6ET_AF'L D o 0 o NOTCH COLUMN IN C3fTFR TO FIT OPTION 3: L4° THFUBOLTS TO v TARRY SE4M SNUG icOOFr 4" FROM ENDS iT .2OT H OFlONS; 3-30-4-s°,ANGLE, (6) O.C. To Z-XL°Xia' ANGLES ;;14 SMS EA I_% EA SIDE OF COLUMN (E3THESL SIDE IF REOMRED BY ' BUIwmt3 DEPT). COLUMN PER'tASffS OR SEALED SI7 m SPECIFIC DRAWING/CALCILA-tMNS ' SECTION. AT SIDE •O•F ROOT PANEL w LAGS, 4' FROM ENDS a 24, MAX- O.C., 1° MIN 13x3/ ° LONIGE.4 THAN PANEL.THIQ�S TO SECURE ROOF SMS ivNVALA.NC=2,__, �TO NOP17MLIHPAY WALLS OI4LY• CAUL{ ALL SCP�tN T(P. TOP sHEADS' BOOM .E1TE ROOF PANEL ZX Z BOX NUN. Z' Z %e' ANGLE, 131 114 � EA L.M. EA SIDE OF BE4M B EAM 'S PLICE OVER COLUMN , ZEE (i} 5e,' LAG HOLTiMil . (SET NCH CARRY BEAM EIt1O; SMS SA- 1' MIN LC04GEP. T1iM BEI OW1 'IDE OF PLATE PANELTHI%USNESS '14SMS ° 74 O.0 ° tv-x TOP �.� ° n it oOT 1 am ° • ,c,' °' , 1 �?�tT AJM PILA �_ ON 11Ci• .... !� ~' SIOEOFCA:arK a ff . _ mu, tMN PER t1_xL_5 ". 16" TYP. TOP & 1 ® BOTTOM 0 0 0 0 0 0 EPS POLY 0 0 0 o ROOF 0 ELITE TYPE 'E' o 0 GUTTER OPTIONAL / 12 SLOPE ADAPTOR SHOWN USE Y" LAG BOLTS W/ 1" MIN. WASHER DIAMETER, 1" MIN_ LONGER CARRY BEAM PERTABLES THAN PANEL THICKNESS SPACED 3X3 POST 914 SMS; 3 SMS PER SIDE (6 TOTAL) - -. •-'W-NtfN-j-AaTENING TQ a1:JMUM IASE:TRl UF.VTHIT'X (•Ya : 3/ ') AT r O.C. FQR UP- Ta i 3U -h F`WMND SPL_D .EXPOSUREE °D"; a O.E.-FOR. -ABOVE 1301M1314AND UP I O _16Q A4PH 0+ING-SPEED E�JoOSURE'D' CAUOK ALL EXPOSED:SCRLw = HE?, s z�;,+A A. WRS - .' .. - -- ROOF:P.A-4EL TO BEAM.F; FOR -COMPOSI E•ROOFS. 910 x V, +: /2'� 6. - S,• It 1-1/4`0 FEAIDER :.WASHERS :@ 12` PANEL i'ttICECAt�+'1'} @ ROOF BEARING ELEMENT -(sH0wN) AND.24r'o:C. NON -BEARING ELEME14F (S)DE W FOR PAN_ ROOFS: (-3f EACH 98 x Ma. LONG S_M-1 P-ER.1:2'_PA�I L lvvl € -ALU �OWUA& Pi4Id 1�/AS HER ROOt- PANEL SOPPOFMN1 BEAM 'EN-fNG-.9ET'Af.L BUCKET THICKNESS MUST BE 1/8 MIN NOTE: THE TAPCONS CAN.BE REPLACED WITH TWO (2) 1/2" WEDGE ANCHORS (REDCAP, HILTI, OR EQUAL) WITH 2-1/4" i { B K MINIMUM EMBEDDMENT. ALSO, IF BUCKET IS BEING ATTACHED TO WOOD USE THE 3/8" - 3" WOOD SCREWS, W/ 1-1/4" WASHERS, TO SECURE THE BUCKETS. WEDGE ANCHOR MUST BE EQUAL OR HIGHER STRENGTH. CONCRETE TWO (2) • 3/8' - 3" CONCRETE LDT38212-> TAPCONS 2-114" (OR EQUAL) I (MIN. EMB.=2-1/4") 2" Min. 3" x 3" BUCKET CONNECTION POLY ROOF COVERED AREA DWG. # RVC-2018-111, REV. 0 January 17, 2018 SHEET 3 OF 3 POLY ROOF CONNECTIONS HEIGHT 8'-0 R V CONSTRUCTION 3318 COLUMBRINA CIRCLE PORT ST. LUCIE, FL 34952 OFFICE (772) 380-8253 LICENSE # CRC 1330965 LOCATION: NA1VI E: STINSON RESIDENCE ADDRESS: 7646 BARN OWL DRIVE CITY/STATE: - PORT ST. LUCIE FL 34952 COUNTY: ST. LUCIE THIS "CIRCLED" CONNECTIONS ON THIS SHEET ARE BEING USED FOR THIS PROJECT. 1 2 3 4 5 6 7 8 9 10 11 NOTE: DRAWINGS ARE NOT TO SCALE . R. A DUNLEA, P.E. 1513 CERVANTES PLACE THE VILLAGES, FLORIDA 32159 (772) 285-6444, (352) 750-6207 bobdunlea(ab-centurVlink.net FLORIDA P.E. Lic. No. 42835 C1TH0 d4 WHO NYn- • • % TAPE F • Q • • ••:cCOR10P•'�N4 s...... •���siO/ONAL • i FND. NAIL do WASHER "4286 I 104. FN5/81 20.0' I.B. NO l.Dj 1 ^ 14.61 1 OI.em ••°d 4a C4 v.� e e ■ 'W .. M 0 ea. b .vd M O z o U) a v z m C Z w M c m ET 1.8 p Zm T s FND. 5/8' I.B. NO LC • v LOT 2 BLOCK 72 UTILITY EASEMENT EXISTING CONCREI TO BE COVERED \ <<q� \4pCUC% �T 'Oq�F MIN TSETTBp.CK REQ. FRON SIDES CNR SIDES REAR ZNG. TECH. CONSERVAR/ON AREA SURVEYOR'S NOTES 1. SURVEY OF DESCRIPTION AS FURNISHED BY CLIENT, UNLESS OTHERWISE NOTED. 2. LANDS SHOWN HEREON WERE NOT ABSTRACTED FOR EASEMENTS, BUILDING SETBACKS, AND/OR RIGHTS -OF -WAY OF RECORD BY ACCURIGHT LAND SURVEYING, INC. 3. ELEVATIONS SHOWN HEREON ARE RELATIVE TO NORTH AMERICAN VERTICAL DATUM OF 1988, SEE SURVEY FOR REFERENCE BENCH MARK, UNLESS OTHERWISE NOTED. 4. THERE ARE NO ABOVE GROUND ENCROACHMENTS, UNLESS OTHERWISE NOTED. 5.ADDITIONS OR DELETIONS TO SURVEY MAPS OR REPORTS BY OTHER THAN THE SIGNING PARTY OR PARTIES IS PROHIBITED WITHOUT WRITTEN CONSENT OF THE SIGNING PARTY OR PARTIES. LEGEND A/C - AIR CONDITIONER FND. - FOUND CONC. - CONCRETE COV'D - COVERED I.P. - IRON PIPE I.D. - IDENTIFICATION I.B. - IRON BAR E.O.P. - ECGE OF PAVEMENT O.H.W. - OVERHEAD WIRE LB - LICENSED BUSINESS V1 Z 4 > R/W - RIGHT-OF-WAY N. & W. - NAIL & WASHERco C.M. - CONCRETE MONUMENT P.B. - PLAT BOOK PG. - PAGE I N - NORTH E - EAST W - WEST S - SOUTH mj a N.A.V.D. 88 - NORTH AMERICAN VERTICAL DATUM 1988 't x N.G.V.D. 29 - NATIONAL GEODETIC VERTICAL DATUM 1929 r � y to 3 SET I.B. - SET 5/8' IRON BAR CAP #4459 n 8 a (P) - DENOTES DISTANCE, ANGLE OR BEARING BY FURNISHED N w W II DESCRIPTION ~a a CF) - DENOTES MEASURED DISTANCE, ANGLE OR BEARING v a CC) - DENOTES CALCULATED DISTANCE, ANGLE OR BEARING wI a Z M J a -j W a W a i m y U U) P �� LEGAL DESCRIPTION Z 'o o" LOT 1, BLOCK 72, FAIRWAYS AT SAVANNA CLUB REPEAT NO. Q th N 1, ACCORDING TO THE PLAT THEREOF, AS RECORDED IN PLAT J CD ,U(U BOOK 57, PAGE 39, OF THE PUBLIC RECORDS OF ST. LUCIE w COUNTY, FLORIDA. Z W Z nn 0 x Z� U a W (n PROPERTY LOCATED IN FLOOD ZONEi X > BASE ELEVATIONi N/A LLI o COMMUNITY PANEL NO., 120287-0283-J Ix Z DATED, 02/16/2012 D Z PROPERTY STREET ADDRESS, 7646 BARN OWL DRIVE V J a PORT ST. LUCIE, FL., 34952 PREPARED FORe JOHN & KATHY STINSON Q Z Z g Q cn Of LLI a Z v BOUNDAPY SURVEY = W �� ACCURIGi 1 1D ' SURVEYING, INC. W USINESS '#6607 o _ . N Z W O 13 QC 13 > EARLE R. STARKEY - PROFESSIONAL LAND SURVEYO W,_ REGISTRATION NO. 4459 - STATE OF FLORIDA A a SURVEY NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL Qin ' In o 0 RAISED SEAL OF A FLORIDA LICENSED LAND SURVEYOR AND MAPPER