Figure 1 The Horseshoe Beach Gulf Coast Supply
office (left) and manufacturing facility.
conditions. Both panels and trim ar!l
using state-of-the-art computerized
found at our facilities in three locat
to assure uniformity and consistenc
manufacture. Panels are roll -forme(
specified by customers in either Ga
any of more than twenty colors of r
gauge, 26-gauge, and 24-gauge hig'
ready for either customer pickup or
ery (customers should call about av
24-gauge metal). Your Gulf Coast r
is waiting to assist you in making tl
for your particular roofing needs.
Gulf Coast's Gulf Rib® panels
from AZ-50 (painted) or AZ-55 (ba
Galvalume) grade 80 coil stock (gi
bare Galvalume finish is not only 4
Figure 3 The Gulf rib panel
highest known quality in the in(
Gulf Coast also stocks a c(
every need of both the do-it-yoi
both in -stock and custom-made
G6iCozi'st
SUPPLY & MANUFACTURING
® The Gulf Coast Gulf Rib®
fabricated
equipment
.ons in Florida,
y in product
l to the lengths
Ivalume or
ainted 29-
i-tensile metal,
on -site deliv-
ailability of
best choice
fabricated
50 for 24
Roofing Panel
Gulf Coast Gulf rib® panels are a strong,
durable, economic, and attractive answer to
the growing demand for metal roofing needs
in Florida and southern Georgia. Extremely
versatile, they are suitable for homes and
businesses as well as agricultural and utility
buildings Gulf Rib® panels provide a 36-
inch coverage with 3/4 inch ribs on nine -inch
centers, and utilize an anti -siphoning channel
to provide protection from severe weather
Figure 2 The 4 locations of Gulf Coast Supply.
able and cost effective, but offers reflectivity so valuable
in the South. The paint system employed on painted
products offers optimum exterior protection plus superior
resistance to corrosion and ultraviolet radiation.
While bare Galvalume carries a 25-year
limited coil manufacturer's finish warranty,
most painted metal carries a 40-year war-
ranty. Both painted and unpainted are of the
line of fasteners, sealants, and other accessories to meet
meowner and the roofing contractor. A complete line of
;s and trims are available in all colors as well.
GULF RIB.. DETAIL MANUAL
Installation of Panels
Roof Pitch
Gulf Coast roofing panels require a certain degree of pitch to ensure proper water. drainage.
Florida Building Code allows a minimum pitch of 2/12 for Gulf Rib® panels as long as lap screws
and sealant are applied to the laps to prevent water from siphoning over the ribs (see Fig. S on p. 4).
Lap screws and sealant are optional when the pitch is 4/12 or greater (4/12 pitch means that there is 4
inches of rise for every 12 inches running horizontally). As a general principle, the less steep the roof,
and the more necessary also that sealant be used at all side -laps. Consult our representative for
recommendations for your particular roof pitch, and about roofing options if you have less than a 2/12
pitch.
Roof Preparation
Oil -canning is a wave -like, rippled appearance extending up the length of the panel after it has
been installed on the roof. Any irregularities in the roof, including uneven plywood joints, warped
plywood, uneven trusses, poor application of underlayment, the use of button caps with felt paper, etc.,
can promote oil -canning. Care should be taken to provide a flat, uniform surface on which to attach
the panels. See page 6 for more details.
Roof Application
Panel installation should begin at the gable end of the roof opposite the prevailing rain -bearing
wind (this will provide added assurance against wind -driven rain being forced under the laps). Measure
one panel width in from the roof edge. At this point chalk a line from ridge to eave. Place the leading
edge of the first panel along this line. It is extremely important that this panel be laid square to the eave
and ridge so that the remaining panels will line up square on the roof frame. It is wise to have a person
at the eave and at the ridge to ensure that the proper panel coverage is being maintained across the roof.
Also be sure that the panels are properly side -lapped (see fig. 7 on page 7).
In applications where end -lapping is necessary, the upper panel on the slope should lap over the
panel that is lower on the slope by about 12 inches. Lesser roof pitches require a greater amount of
panel overlap. All end -lap applications should use two horizontal rows of butyl sealant tape across the
panel and proper fastening to provide a maximum water seal.
An overhang of 2 to 3 inches on the eave is recommended to provide a drip edge, while only 1
inch overhang is necessary where gutters are used. The open panel ribs at the eave can be sealed with
inside closures. For maximum weather -tightness, a row of butyl tape can be applied above and beneath
closure material.
Trimming and Cutting Steel Panels
The best device for cutting steel panels across the profile is either hand snips or a nibbler.
Nibblers, and especially Carborundum blades on electric saws, however, do have a. tendency to either
leave hot metal particles that can burn paint surfaces or to leave rust marks on panels and trim. The
same is true of any filings left on the roof caused by the application of screws. Care should be taken to
brush all such particles from roof surfaces after application.
To cut panels lengthwise: Note carefully where the panel is to be cut, and, using a straightedge,
score deeply down the length of the panel with a sharp -pointed utility knife. Folding the panel along the
score mark, and bending back again if necessary, should produce a clean break in the panel.
CAUTION! clean all metal shavings and particles off of roof to avoid unsightly rust stains
Residential Trim
Seep. 12 for Siding Trij
trim
\11)
Sidewall
Roll Lite Door
Transition
Flashing
(p.10)
Figure 4 Roofing trims and flashings are named' by the
location or function, of that particular piece on the building.
Gulf Coast
SUPPLY & MANUFACTURING
Valley ca Ridge g p
8)
Panel lan detail
Lap Screw Apply sealant
to lap
overlap
0-1
purlin-bearing leg decking;
Figure 5 Butyl tape or caulk is required when the
roof pitch is 3/12 or less, with lap screws applied
every 2 feet to maintain water -tightness of the lap.
On pitches greater than 3/12, lap screws and butyl
tape are optional. For more details on screws,
see pgs. 6 and 7.
GULF ,RIB''" DETAIL MANUAL
Ordering Roof Panels and Screws
Care should be taken to order panels of the correct length to avoid having to make
corrective measures after purchase. Panel lengths should fall 2 to 3 inches short of the ridge when
a vented ridge is desired, and should extend 2 to 3 inches past the eave to allow a sufficient drip
edge (except as noted on pg. 3 concerning gutters). When a roof transition is involved, panels of
the upper portion should be ordered short to allow placement of the transition flashing (see
diagram -on p. 10). The Gulf Coast sales personnel are ready to assist customers with information
specific to their particular roof.
Specially-washered screws applied through the flat of the metal is the most recommended
method used to attach roofing panels. 1-inch screws can be used if penetration of only 3/a inch is
either necessary or desired; otherwise, 1% inch screws are usually recommended. 2%2 inch screws
are also available, and are often used by those who adhere to through -the -rib fastening, and for
ridge -cap application. See pages 6 and 7 for more information on screw spacing and ordering.
Ordering and Applying Trim
The most common flashing for metal roofing is the ridge cap, which is used at the peak of a
roof where two opposing roof slopes join. Other flashings include transition flashing, end wall
and sidewall flashings, and valleys (see diagram on right for application). Eave trims include
gable flashing and eave drip, either of which are often applied above fascia trim. When roof pitch
exceeds 5/12 (a 5 inch rise in 12 inches), the slope of the roof should be mentioned when ordering
ridge caps, endwalls, and eave drip. When a steeper roof slope meets a lesser slope, both slopes
should be mentioned when ordering transition flashing.
At the gable edge the use of gable trim adds to the appearance of the structure and protects
the fly -rafter, and sidewall flashing is used where the side of a panel butts up against an adjacent
wall. In either case, the installer should be careful to seal between the gable rake or sidewall and
panel with butyl sealant tape, and to fasten the rake every 6" to 12" up the slope of the roof with
the appropriate screws. If eave drip is used on the gable, the number of 90 degree eave drip
should be specified separately from that used on the drip edge when ordering.
To prevent penetration of water, insects, and debris at the ridge, outside closures should be
inserted between the ridge cap and the;top end of the panel. Screws are applied through the ridge
cap, closure, and rib in at least every other rib of the panels. At least a 1 %z" (or preferably 2%2")
screw should be used for attaching ridge caps. Self -drilling lap screws can also be used to attach
ridge caps.
Keep Materials Dry!
.Paint and finishes of Gulf Coast panels and trim are designed to withstand severe rain and
wet weather conditions. Neither paint, galvanized, or Galvalume finishes, however, are designed to
be in continuous contact with water for long periods of time. Damage will result if uninstalled
panels or trim are allowed to remain wet in storage. Be sure to store material that will not be
.installed immediately in a dry location. Wet material should be air-dried and re -stacked if
installation is not planned right away.
How to Figure and Apply
Gulf Coast Supply carries screws in.3 di f
inch, and 2 '/2 inch. 1-inch screws will bar
1'/2 inch are the best all-purpose size. 1')'-
necessary for attaching ridge caps. The
used to figure approximate quantities of si
spacings and sizes of roofs. For 2-foot. sp
screws, multiply the total linear feet of me
Example: your order is 1250 feel
1250 x 2.7 = 3375 Is
Please confirm all estimates with your Gul
you placed your order.
Codes allow re -roofing over shingles
provided the roof has been checked by a lilI
Gulf Rib metal roofing can be separate
pine battens spaced on maximum 24"cente
direct contact between pressure treated
potential corrosion, Gulf Coast Supply se
CAUTION: Battens must be fastened
minimum 8d common or pneumatic nails
calculations according to ASCE 7-98). Ba
of ridge, eave, hip, valley, and gable -end
For solid decking, at least 15/32-inch stl
center is required.
If care is taken, metal roofing applicat:
quickly and accurately into the desired spa
accurately in the proper locations on panel
For panel lap details, see Figure S on I
Gu liC''Woast
SUPPLY & MANUFACTURING
ws
crews
acin
�f
Screw
urlin S acin
12 inch 18 inch
24 inch
0
50
270
180
135
Brent lengths: 1 inch, 1'/z
100
540
360
270
ely penetrate a lx4, but the
°0
200
1080
720
540
or V/2-inch screws are
300
1620
1080
810
table on the right can be
400
2160
1440
1080
for various purlin
500
2700
3246
1800
1350
a
600
2160
1620
g between rows of
o
700
3780
2520'.
1890
tal times 2.7
t
800
4320
2880
2160
of Gulf Rib roofing.
-
900
4860
3240
2430
21
1000
5400
3600
2700
crews
E�
1100
Coast representative when
p
1200
6480
6480
4320
4320
3240
3240
without the use of battens calculation chart
tensed roofing contractor to insure levelness and pullout integrity.
d from the moisture barrier by minimum, nominal 1 "x3" yellow
rs, or according to ASCE calculations where applicable. Since
lumber and metal roofing must be avoided in order to prevent
lls only untreated battens.
to the roof deck with minimum #6 screws at 12" on -center, or two
paced 8" on -center, or one every 4" on -center (or by applicable
(tens must be installed to support the entire width and length
plywood supported on rafters at a maximum of 24" on
can be aided by pre -drilling panels, allowing screws to go
.g. Pre -drilling will work provided that pilot holes are placed
Purlin spacing must be uniform and carefully measured.
e 4.
Gl if Coast Policies
Delivery policy Delivery charges apply to all orders where delivery is requested. Please consult your Gulf Coast sales
department for details.
Sales tax All orders picked up at Gulf Coast Supply, and all orders delivered within the state of Florida, are subject to
state sales tax. Tax exemptions should be ve ified prior to delivery or customer pickup.
Warrantied products A 40 year warranty appli I s to most material* manufactured from painted coil stock, and a 25-year
warranty to Galvalume material. Ask for details.
Indemnity All prices and designs are subject to ',change without notice
Disclaimer While we have made every attempt at accuracy in this manual, we are not responsible for typographic,
printing, or technical errors.
Oil Canning —a repeating, wave -like appearance
phenomenon in metal panels like Gulf Rib ro
defect, nor a cause for rejection. See p. 3 for I
Return policy All panel orders and special orde
refundable once they are manufactured. Stan
clean, resalable condition. For details, go to
bottom of page, or call Gulf Coast Supply to
i the length of the panel —is a common and often unavoidable
3ng that have large, flat areas within the panel. It is therefore not a
;tails on.how to avoid oil -canning.
(non -stock) trims are considered the property of the customer and non-
ird trim and accessories are refundable providing they are returned in a
ww.gulfcoastsupply.com and click on "No Hassle Return Policy" at
ik specific questions about returns.
i
.` m
GulfCoast
SUPPLY & MANUFACTURING
Gulf Cast Gulf.Ribo Roofing Pawls
Fastening Schedule for Various Wind Speeds — minimum 2:12 roof pitch
Wind Speed Zone
130 MPH
140 MPH
150 MPH
160 MPH
Roof
Fastener
Fastener Size
Attaching to.
On Center
On Center
On Center
On Center
Zone
Type
Spacing
Spacing
Spacing
Spacing
Zone 1
Woodgrip
WoodZace
#9-15 x 1'/z
min.15/32
plywood
24"
Type 1
24"
Type 1
2411
Type 1
24"
Type 1
Zone 2
Woodgripe
#9-15 x 1'/z
min.15/32
2411
2411
24"
24"
Woodzac®
plywood
Type 1
Type 1
Type 1
Type 2
Zone 3
Woodgripe
Woodzac®
#9-15 x 1%
min.15/32
plywood
24"
Type 2
2411
Type 2
24"
Type 2
24"
Type 2
Fastener pattern Fastener pattern
Type 1 Fastener patterns Type 1 and Type
2 are shown at left, row spacings are
Type 2 shown in the table above, and roof
zones are displayed on left below.
Figure 7 shows a simple illustration of
Zone 2 a the patterns. Note that fastener pattern
Eave Type 2 is required at top, bottom, and
:..........................
a end laps of each panel, as well as in
......................................
additional areas according to which
roof zone the fasteners fall in.
Each "zone" of the roof has its own
I
..•.•.... `...••..••••.•...... screw requirements. Dimension is
_ _ t _ a defined as 10% of the minimum width
------------------Ridge----------- of the building, or40%of the mean
height of the roof, whichever is
Gable smaller; however, a cannot be less
Zone 1 than either 4% of the minimum width
:...I of the building, or 3 feet.
\ ... .......................... I
ne 3
Ospa,,
ter�n
A`~
Cro .�r
}
1
Figure 7 Screws should be placed on both sides of the ribs at both eave and ridge, to
and on the overlap side of any panel laps.
i
DETAILIMANUALGuIfCo6 t
SUPPLY & MANUFACTURING
Eave Drip
& Fascia.
s�
FHA Style ED-3 Style
,1 Eave drip Eave drip
7/16'
T For custom eave drip, specify the
Eave drip a
Eave drip with fascia a7id inside closure amount of the eave that will be
Figure 8 Eave drip and fascia give a finished look along the drip
covered (dimension "a"), and, for
eave of the house, as well as providing protection for the steeper roofs, specify pitch . If
materials they cover. The eave drip should 'completely cover the Fascia a fascia is desired, be sure that the
top edge of the fascia. Inside closures, which seal off the open dimension you order will be
ribs of the panels, are optional. --►i b H--- hidden by the eave drip.
Summary of Stock Trims and Flashings
item I cnorial ardor infarmadan
Ridge caps (RC-2)
specify pitch if less than 3/12 or greater than 6/12. Also available in
larger widths. Closures recommended.
Eave drip (FRA, ED-3)
2 common styles. FHA style is pre -pitched for 3/12 to 6/12 roofs. For
appearancelor ease of application, order by either specific pitch or as
gable trim (901).
Gable flashings
Residential (EF4), large (GR-2), and small (GR-1) rakes available. Use
butyl sealant between rake and panel.
Valleys (PV 1)
specify pitch if greater than 7/12. Seal with universal foam closure
material. Open -hemmed valleys (PV 2) aid water -tightness.
Sidewall (SW-1)
Use butyl sealant between sidewall flashing and panel.
Endwall (EW-1)
Specify pitc i if greater than 5/12. Seal with outside closures.
Transition flashing
Specify pitches of both roofs. Seal lower slope using outside closures and,
if desired, in�ide closures on upper slope.
( ) GULF RIB'" DETAI4 MANUAL
Ridge Cap Ool.
The Ridge Cap is used to seal the point at
which two upward slopes meet. This can
be both along the ridge of the roof as well
as a covering for a hip. Either woodgrip
or self -drilling lap TEK screws are
applied through the ribs of the metal.
Since debris, insects, and blowing
rain can find easy access under the ridge
cap, closures are required to either
completely or partially seal the opening.
Closures under ridge caps come in 3
types: solid, vented, and hip tape. Figure 9
Solid closures ("Outside Closures") are (right).
the same width as the panels. They lock together in a row placed directly
under the screws that attach the ridge cap, and form a solid, water -tight,
air-tightbarrier.
Profile Vent® comes in 50 foot rolls, is 3 inches wide, and forms a water -
retardant, insect resistant barrier that allows hot air to escape from the
attic, and is superior to many more elaborate and expensive vent systems.
Any length maybe ordered.
Hip closure tape (Peel and Seal) is a sticky, adhesive -backed metallic tape
that seals the hip roof. It is 6 inches wide and comes in 33'h foot rolls.
Because it must be conformed to the rise and fall of the panel ridges,
approximately 10% extra may be needed beyond the length of the hip
being covered. -
Outsi
.close
I
screw required
ent®
•sa-Vent®
RC-2 Standard 12-inch Ridge Caps
are strong, economical and adequate for most of your roofing needs
6"__�
RC-1 style 12-inch Ridge Caps
are also available in custom widths
Ridge cap showing outside closure (left) and profile vent
Figure 10 Pipe Boots provide a
water -tight seal around roof
vents and come in a variety of
sizes. They seal with caulk and
conform to the shape of the
panel ribs.
a�
.55—
RC-2 style over -sized ridge caps
are available with 18-inch coverage, or as a custom trim
item in total widths (2 times "a") of 14-, 16-, 18-, 20-,
22-, and 24-inch
Figure 11 As with the ridge cap, the IENDWALL
FLASHING above is sealed using outside clos res.
Use EW-2 hemmed endwall when comering endwl lls with sidewall
flashing, such as with dormers or chimneys.
For custom end -walls, speck roof pitch and dimensions "a" and "b"
Transition Flashing
The TRANSITION FLASHING preven
leakage at the point where two different roc
pitches meet. It must be sealed on the lows
side with outside closures, and can be seale
underneath the upper panels with insk
closures. The similar GAMBRE
FLASHING is used where the lower pitch
steeper than the upper.
TF-1 Transition Flashing
cloiurel�61�2,�
For custom transition flashing specify the pitches
of the two roof slopes and, if necessary, dimensions
"a" and "b„
GullC®ast
SUPPLY & MANUFACTURING
® End -wall Flashing
End -wall flashing is applied where the upward
slope of a roof meets a wall. The wall side of
the flashing can 'be covered with siding or
counter -flashing, and outside closures are
necessary to seal
recommendedd)) caulk (Solar between t h e
l� V_- edge (order EW-1C)
flashing and the
L3�
lk e
3 ��(used if endwall not panel. Roof slope
covered by siding) s h o u l d b e
mentioned if roof
" exceeds 5/12
\y pitch.
EW-1 Stepped
b Endwall
Figure 12 The transition flashing
(above) and the GF-1 gambrel
flashing (right) provide a
continuous drainage where two
slopes. meet. Both seal with
outside closures on the lower side.
EW-2 Hemmed
b Endwall
�a a=4%"
\� b=3"
1
Gable Flashing
Jolo-
ault�l
EF-i sib
Custom trimspecify a custom
length for a or b.
Standard dimensions — a = 3"
b=3"
GR-1 style
Custom trim —specify a custom
length for a or b. b
Standard dimensions — a = 2 N
b = 21/8"
Figure 14 Sidewall flashing is applied when the side of the
roof butts up against an adjacent wall. The wall -side of the
flashing can either be covered over with siding or sealed
with caulk (order SW-113). Butyl tape should be applied
where the "foot" of the flashing attaches to the roof.
GUIX06 t
SUPPLY & MANUFACTURING
,,;,;
View qJ &P4gable trax ascra oar remove
Figure 13 Gable flashing is used to trim the edge of the
roofing panel at the gable end of the roof. It should match
the eave drip that extends along the drip edge of the roof. If
the panel is allowed to hang over the gable end, eave drip
can be used instead. Butyl tape between the trim and
panel eliminates leaks.
® Side -wall Flashing
caulk (Solar Sear recommended)
caulk edge (order SW -IC)
(used if sidewall not
covered by siding)
3"
y 3 Butyl tape
3/4"
5 11
SW-1 _
Custom trim —specify a custom
length for a or b. a ► i
Standard dimensions — a = 3"
b=3"
GUIX0"0 4N 21WN.
6t
SUPPLY & MANUFACTURING
Preformed
Valley
Install panels 2 to 4"
from diverter
— panel
o c
PV 1 style �— a —►� ° °
PV 2 style
Two basic styles of valley are available.
For custom valleys, specify dimension "a"
Figure 15 Pre -formed valleys use a diverterto prevent water
from rushing under panels on the opposite side, while
meanwhile channeling water off the roof. Expanding foam
closures are often used to assure a good seal.
Gulf Coast Gulf Rill ® Siding
if GR-2 Rake &
f l Corner p. 13
i
Dripp Cap
I
Slidin
!�I Door
J-Channel
(p.14)
Figure 16 Common t
Base Drip overp.
(p.14)
V
'Ims associated with Gulf Rib roofing panels
GULF RIB` DETAIL MANUAL
GR-2 outside Corner - Poo.
The GR-2 Rake and Corner can be used as a
gable trim or a corner for metal -sided buildings.
As an alternative, the smaller EF-1 or the GR-1
(both on p. 11) can also used as gable rakes, and the
PC-5 (below)or the GR-1 as corners.
Customizing rakes or comers is often necessary
due to their landing on a panel rib. Both the GR-2
and the IS-2 can be ordered as custom trim items
by specifying custom dimensions "a" or "b". Be
sure to take into account the 3/a" "head space" when
figuring custom dimensions.
1
3
The PC-5 flat corner
works best on smaller
structures, and where
the panels are running
horizontally. It can be
sealed with outside
closures.
Figure 17 When used as corner trim, the GR-2 straddles the ribs
of the panels where they meet at the corner of the building. The
Gulf Rib outside corner also serves as a gable rake (see below).
The inside corner (IS-2) has similar dimensions but with a
reverse middle bend.
Figure 18 When used as a gable rake, the GR-2 runs parallel to the ribs of
the roof panel, and is attached with screws running through the ribs of
upright siding. As with the EF-1 residential rake, the roof side can be
sealed with butyl sealant.
A GR-2 Gable Rake
4 5/8"
s
• '•
a
./
GuIfC®ast
SUPPLY & MANUFACTURING
Drip Cap and
J-Channel
DC-1
Drip cap,
capping the panel end
® JC-1
J-channel
Figure 19 The drip cap is commonly us e d to trim out the bottoms of panels [.*-1�
over doorways and windows, and occasionally takes the place of base drip.
J-channel is used to cap raw panel edgeslwhere run-off is not a problem, and panel 7/s"
is most commonly used to trim around the 1bottom,.sides, and occasionally the
top of windows and doors, and also to cap the top sides of skirting. �42'/a''�
Icapping 'the panel edge
Base Drip Poo,
Figd,re 20 Base drip seals off the bottoms of panels at the floor level, where
it he,ps to prevent the entrance of rodents and insects, as well as a base for
the setting of panels.
GULF R1B"DETA:IL MANUAL
Gutters
Gulf Coast Supply produces 29-, 26-, and 24-
gauge gutters in either 5- or 6-inch widths (depth is
approximately equal to width). All gutters
should be ordered specific to the pitch of the
roof. Downspouts are available in Yx4" (for 5-
inch gutters) and 4"x4" (for larger gutters). End
caps should be ordered at the same time as the
gutters to assure a custom fit. Special hangers fit
into the panel rib and under the gutter lip. Panels
should extend no more than 1 " to 1'/z" inches
beyond the eave on which gutters are planned.
lap screws
�-5 or 6"—►I net
Gutter hangers fit inside
panel rib and under lip
of gutter (apply at least
one per panel) and are
attached with lap screws
or rivets.
Figure 21 Exposed view of gutter showing gutter hanger
placement, downspouts, and end caps. Hangers employ lap
screws, and end caps are best attached with rivets.
Outer Inner -> Outer ,�j- Inner Outf
Inner and outer gutter sections (marked `I" and "O")
alternate along the eave to assure ease of application and
gutter appearance.
Downspouts in excess of 10 feet in length must
be made in 2 sections.
® Track Covers
� j f
i I �
-' J . _ c
5"i
Figure 22 Sliding door track covers fit over the door track and
under the panels to hide the track, assure a neat appearance, and
shed water over the door.
TC-1
sliding door
track cover
GULF R1B"..DETAIL MANUALGuIfCoast
SUPPLY & MANUFACTURING
Ili
Ridge caps (pg. 9)
Eave drip (pg. 8)
Valleys (pg. 12)
�,.
Gable rakes (pg. 11)
Wall 10 1 s
flashingsn(pg gambrel
Corner trims (pg. 13)
Door & window
trims (pg. 14)
ase drip (pg. 14)
pipe Boot (pg. 11)
Electrical Boot
Reflective bubble
insulation
Inside Closures
a _-
a�: .
Outside Closures
Flex-o-vent
®
Profile Vent
Expanding
Foam
Peel and Seal
Touch-up Paint
ISDTEK
Lap TEK
Butyl Tape
Titebond®
Woodgripo
Screws
I TEK screws
WoodZac screws
WoodMac screws
Gl ide to Misc. Accessories
item
I application
pipe boot
Fits over vent and heat pipes. Available also in heat -resistant boots.
electrical boot
Fits arounpipes with inaccessible tops (such as weatherheads). _
outside closures
inside
Required to seal under ridge caps and transition and endwall flashings.
Seals the
closures under panels, particularly on eave.,
Profile Vent® Flex-o-Vent® Vented closure material surpassing many other venting systems.
expanding foam
Compressed adhesive foam expands to seal between valleys and panels.
Peel and Seal"
Seals hips ehnder hip caps. Also, a general purpose sealing tape (6" wide).
touch-up paint
Hides scratches and mars encountered in installation.' Over 20 colors.
butyl tape
General purpose low-cost sealant, used on panel laps and under trim.
I
Titebond®
A superior general purpose caulk for all joints. Matches panel colors._
Low profile insulation
Greatly re uces radiant heat when installed under panels.
Woodgrip screws
Used in all pplications attaching metal to wood. 1", IV2", 1%'I sizes.
TEK screws
Self drilling TEK screws for metal purlins. Lap TEK screws draw
together joints and attach trim.
ZAC" screws
"Lifetime" Iscrews; 1%", 2'/ ", threaded for wood.; self -drilling available.
Version 01-26-16