Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL ASPHALT SHINGLES12/14/201.7 L. Florida Building Code Online J1 BCIS Home 1 Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts 3 Publications I FBC Staff Florida fit `-• w.. cK Product Approval USER: Public User SCANNED ce &&3m BY Product Approval Menu > Product or Aoolication Search > Application List > Application Detai{�Q r� ��.� w �-Untv t Lucie EO!"lAw FL # FL10124-R20 F�l Application Type Revision 10111 Code Version 2017 Application Status Approved Comments Archived Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, NJ 07054 (800)766-3411 mstieh@gaf.com Authorized Signature Robert Nieminen lindareith@trinityerd.com Technical Representative William Broussard Address/Phone/Email 1 Campus Drive Parsippany, NJ 07054 (800) 766-3411 Tech n Ica lQuestionsGAF@gaf.com Quality Assurance Representative Address/Phone/Email Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer 0 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 10/20/2018 Validated By John W. Knezevich, PE 96 Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL10124 R20 COI 2017 01 COI Nieminen.odf Standard ASTM D1970 . ASTM D3161 ASTM D3462 ASTM D7158 TAS 107 Year 2015 2016 2010 2011 1995 - https://www.floddabuilding.org/pr/pr app_dti.aspx?param=wGEVXQwtDquracBeVCbdMQNZD6Zesy3BoOyLwXhMdCmfpy!EO[vyCA%3d%3d 1/2 12/14/2017 Florida.Building Cod Online Sections from the Coae Product Approval Method Date Submitted Date Validated Date Pending FBC Approval, Date Approved Method 1 Option D 09/20/2017 09/27/2017 09/28/2017 12/12/2017 ,Modell Number�or. Name ` d" , _ Description ti .. K " : , - 0124.1 GAF Asp�lalt Roof Shingles Fiberglass reinforced 3-tab, laminated, 5-tab and hip/ridge asphalt shingles Limits of Use Installation Instructions Approved for use in HVHZ: No FL10124 R20 II 2017 09 FINAL ER GAF Asohalt Shinales FL10124-R20.pdf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER, Section 5. Evaluation Reports FL10124 R20 AE 2017 09 FINAL ER GAF Asphalt Shingles FL10124-R20.1)df Created by Independent Third Party: Yes The State of Florida is an AA/EEO Under Florida law, email addresses are p mail to this entity. Instead, contact the ofi Florida Statutes, effective October 1, 201: provided may be used for official commu provide the Department with an email adc tact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 oyer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement records. If you do not want your e-mail address released in response to a public -records request, do not send electronic phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), nsees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails on with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ' Credit Card . Safe EOIvyCA%3d%3d 2/2 j EXTERIOR RESEARCH & DESIGN, LLC. ""QCertificate of Authorization #{9503 UNIT #13 �f RINIT � EIRD 353 CHRISTIAOXFORD, �CT 6478 (203 ) 262-924 5 EVALUATION REPORT GAF Evaluation Report 01506.01.08-1122 1 Campus Drive FL10124-1120 Parsippany, NJ 07054 Date of Issuance: 01/03/2008 (800) 766-3411 Revision 22: 09/20/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityJERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DC4ANE1983 The facsimile seal appearing was authorized by Robert Nieminen, P.E. on 09/20/2017. This does not serve as an electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. r QoTaINITYIERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with t�e following Standards. Compliance is, subject to the Installation. Requirements and Limitations /Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4 / 1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3 / R905.1.1 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: Kniiiy Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) Wind Dri Rain GAF-407-02-01 01/21/2013 UL (TST 1740) ASTM Ien D3462 93NK6295 11/29/1993 UL(TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 OINK06632 02/02/2001 UL (TST 1740) ASTM D3161, TAS 107 OINK9226 05/21/2001 UL (TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3162 O1NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5367 03/11/2003 UL(TST 1740) ASTM D3462 03NK26444 10/17/2003 UL(TST 1740) ASTM D3 62 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3 62 04NK22009 05/06/2005 UL (TST 1740) ASTM D3�61 04NK22009 05/09/2005 UL (TST 1740) ASTM 1)3�62 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL(TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161,D3462 06CA18074 06/16/2006 UL (TST 1740) ASTM D3 161, D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3 62 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161, D3462 06CA41095 12/27/2006 UL (TST 1740) ASTM 1)31161 07NK05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3 161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3 161, D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D31161, D7158, D3462 OBCA06100 03/13/2008 Exterior Research and Design, LLC. Evaluation Report 01506.01.08-R22 Certificate ojAuthorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 2 of 6 L r QOTRINITYIERD Entity Examination Reference Date UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IOCA13686 05/15/2010 UL (TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL (TST 1740) ASTM D3462 IOCA11953 10/29/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IONK11951 10/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 IONK12070 11/04/2010 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 UL(TST 1740) ASTM D3161,D7158,D3462 11CA48725 12/09/2011 UL, LLC. (TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 12CA58151 02/15/2013 UL, LLC. (TST 9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, LLC. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4786875675 07/17/2015 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mobile, AL 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA 10/20/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tuscaloosa, AL 11/11/2016 UL, LLC: (QUA 9625) Quality Control Inspection Report, R21, Michigan Cty, IN 11/01/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Shafter, CA 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mt. Vernon, IN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD 10/21/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 11/04/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Ennis, TX 11/03/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Fontana, CA 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquis® WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, FortitudeT", Glenwood'"", Grand Canyon®, Grand Sequoia®, Grand Sequoia® IR, Grand Sequoia® ArmorShield"", Monaco®, Sienna®, Timberline® American Harvest®, Timberline® ArmorShieldT" II, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland® are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline® is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShieldTM' Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Exterior Research and Design, U.C. Evaluation Report 01506.01.08-R22 Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 3 of 6 �1NITYIERD 4.3 Accessory Starter Strips: 4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlocker'"I Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Sltarter Roll is a is a mineral -surfaced, fiberglass -reinforced, self -adhering SBS modified bitumen starter step, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatchT4 Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia® series asphalt shingles. StarterMatch'"I are installed as the second starter for Grand Canyon® and Grand Sequoi �® series installations. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or desig� guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of t is product. 5.4 Wind Classification: 5.4.1 The.GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Va, = 150 mph (V„it =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingl( and R905.2.6.1 to ASTM D3 to Vind =150 mph (V,,it =194 5.4.3 Classification by ASTM D71! mean roof height of 60 fe conditions outside these lim 5.5 All products in the roof asses 6. INSTALLATION: 6.1 Underlayment: 6.1.1 Underlayment shall be accel Locally Approved per Rule 61 6.2 Starter Shingles or Starter S1 6.2.1 Installation of Pro -Start Eave Shingles and QuickStart Peel 6.3 Asphalt Shingles: 6.3.1 Installation of asphalt shingle (4) nails per shingle in accorc ➢ Camelot, Camelot II, G and Woodland require ➢ Slateline requires minir 6.3.2 Fasteners shall be in accorda or R905.2.5. Staples are not 6.3.3 Where the roof slope exce, required. Contact the GAF f( noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 11, Class F, indicating the shingles are acceptable for use in all wind zones up ph). Refer to Section 6 for installation requirements to meet this wind rating. applies only to exposure category B or C, as defined in FBC 1609.4.3, and a or less. Calculations by a qualified design professional are required for tions. Contact the shingle manufacturer for data specific to each shingle. )ly shall have quality assurance audit in accordance with F.A.C. Rule 61G20-3. to GAF and shall hold current Florida Statewide Product Approval, or be , per FBC 1507.2.3, 1507.2.4 or R905.2.3. rRake Starter Strip Shingles, WeatherBlocker Premium Eave/Rake Starter Strip & Stick Starter Roll shall comply with the GAF current published instructions. shall comply with the GAF current published instructions, using minimum four ince with FBC 1507.2.7 or R905.2.6, with the following exceptions: and Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, iinimum five (5) nails per shingle. um six (6) nails per shingle. ce with manufacturer's published requirements, but not less than FBC 1507.2.6 s 21 units vertical in 12 units horizontal, special methods of fastening are details. Exterior Research and Design, U.C. I Evaluation Report 01506.01.08-1122 Certificate of Authorization #9503 6T" EITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 4 of 6 TTFUNrry I ERD 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal -A -Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". 11.5° Sealant 1^ (292 mm) V Sellante (25 mm) (25 mm) Enduit d'etancheite (305 mm) Clavo g rig 7 5/8" Nail Clouer (168 -194 mm) 12' (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP1 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. 1W - Sealant 17(292 rntei) 1. 6411.109 httn) (� n1Ir1 rzaduit d'@tbrtch0a .M . MP H Itr 12• (305 W'rn) 91 (229 nim) 12' (135 MfY9 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, I.I.C. Certificate of Authorization#9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION GAF Asphalt Roof Shingles Evaluation Report 01506.01.08-R22 FL10124-R20 Revision 22: 09/20/2017 Page 5 of 6 Q0TR1-N'1.TYjERD 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers Sf�all indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 QA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC — QUA9625; (847) 664-3281 END OF EVALUATION REPORT - Exterior Research and Design, LLC. IEvaluation Report 01506.01.08-1122 Cert1ficate afAuthorlrotlon p9S03 6T" EDITION (2017) FBC NON-HVH2 EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 6 of 6 �l TRINITY I ERD APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE " .. Table Deck Application Type Description Page 1A-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 5 113 Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 1D Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 lE-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 ` -2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 8 1F Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 8 2A Steel or Structural concrete New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 9 28 Steel or Structural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 30 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 313 Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1• Bonded Insulation, Bonded Roof Cover 15-16 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 SC CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 5D CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 713 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes aoaly to the systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-inch penetration. ➢ Steel: Minimum 0.75-inch penetration and engage the top flute of the steel deck. ➢ Structural concrete: Minimum 1-inch embedment into pilot hole in accordance with fastener manufacturer's published installation instructions. 3. Unless otherwise noted, insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -wool roof board that meets the QA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover. Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6 H EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26 TRINITY I ERD 4. Minimum 200 psi, minimum 2-inch thick lightweight insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). 6. Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published instructions. ➢ HA (HA): Full coverage at 25-30 Ibs/square. ➢ Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. ➢ Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c. ➢ OMG OlyBond 500 (O13500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. ➢ OlyBond Classic (OB Classic): Full coverage at 1 gal/square. ➢ ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c. ➢ Note: When multiple layers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance of one-half the ribbon spacing. ➢ Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocya n u rate at the following thickness limitations may be substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table: ➢ Millennium One Step Foamable Adhesive (M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) ➢ OMG OlyBond 500 (OB500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG OlyBond 500 (06500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+ GL) ➢ OMG OlyBond 500 (OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) ➢ OMG OlyBond 500 (OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam II) ➢ ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC -Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29,-Roofing- pplication-Standard-RAS11Zand-Roofing-Application-Standard-RAS 137-Assemblies-marked-with-an-asterisk*-carry-the-limitations-set-forth-in Section-2:2.10:1 of -FM -Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the insulation is optional; however, the existing roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL36027-112 Certificate of Authorization #9503 If"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 2 of 26 \J I f�NINIERD 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. TABLE 1 'BUILT Rooe CovERS Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type If (Base and Ply sheets, Asphalt -Applied) HA at 20-40 Ibs/square Ply FBC Approved ASTM D2178, Type IV or VI SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40 Ibs/square (SBS, Asphalt -Applied) SBS-TA Cap Ply TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base Ply TriBuilt SA SBS Base (SBS, Self -Adhering) Self -Adhering Cap Ply TriBuilt SA SBS Cap APP-TA Base Ply or Ply TriBuilt APP Smooth (APP, Torch -Applied) Torch -Applied Cap Ply TriBuilt APP Smooth, TriBuilt APP Granular APP-SA Cap Ply TriBuilt SA APP Cap Self -Adhering (APP, Self -Adhering) 16. Vapor barrier options for use over structural concrete deck followed by.adhered insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: ' e u. VAPORBARRIER,OPTIONSTRUCTURA4�CONCRETEDECK;'ADHEREDINSI�IATION,PERTABLE3A,� - - Option # Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach VB-1. ASTM D41 TriBuilt SA SBS Base Self -Adhering Inta-Stik or CR-20, 12-inch b.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Insta-Stik, 12-inch o.c. -75.0 VB-3. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Millennium One Step Foamable Adhesive, 12-inch o.c. -157.5 VB-4. ASTM D41 TriBuilt SA SBS Cap Self -Adhering CR-20, 12-inch o.c. -270.0 VB-5. ASTM D41 TriBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20,12-inch o.c. -290.0 17. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Renort-A42970.10.12-112 for FL16027-RZ Certificate of Authorization #9503 e' EDITION (2017) FBC NON-HVHZ EVALUATION 7.0 25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 0 TABLE 1A 1 WOOD DECKS NEW CONSf kG ION oR -3 REROQF (Tenn OFF) SYSTEM TYPE A 2 AT�1'ACHED ANCHOR SHEET, BONDED INSULATION; B'.ONDED:ROOF COVER vMECH,ANICALLY, Top Insulation P,, o1DP �(psf) System Deck Anchor Sheet Base Insulation Type Fasteners Attach Type Attach No. (Note 1) Type 'Attach Base Pf Min. 0.25-inch Dens Polyglass G2 Base, 8-inch o.c. in 4- Deck, Dens Deck Prime, ` 32 ga., 1-5/8- inch lap and 8- (Optional) FBC SECUROCK Gypsum- / Min.19/32- CertainTeed Glasbase, inch diameter inch o.c. in Approved, Fiber Roof Board, Min. { SBS-AA, W 1 inch plywood Firestone MB Base, JM tin caps with 11 three, equally ASTM C1289, HA 0.75-inch FescoBoard HA BP -AA /ptlonal) SBS-TA, ,- -60.0 at max. 24- Perma-Ply 28, Tamko ga. annular ring spaced, type II polyiso- BP -AA (homogeneous) or min. APP-TA inch spans Glass Base or shank nails staggered cyanurate 0.5-inch Structodek GAFGBas LAS #75 center rows High Density Fiberboard Roof Insulation Polyglass G2 Base, 8-inch o.c. in 4- Min. 19/32- CertainTeed Glasbase, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC Min. 0.25-inch Dens (Optional) SBS-SA, inch plywood Firestone Base,, inch diameter inch o.c. in Approved, Deck, Dens Deck Prime, One or APP SA,or W 2 at max. 24- Perma-Ply 28 Tamko tin caps with 11 three, equally ASTM C1289, HA SECUROCK Gypsum- yp HA SBS-SA more SBS- SBS-TA -%0 inch spans Glass Base or ga. annular ring spaced, typeJI polyiso Fiber Roof Board APP-TA shank nails staggered cyanurate APP-TA GAFGLAS #75 center rows 6-Inch o.c. in 4- Min. 2-inch D-IS, OB500, Min. 19/32- 32 ga., 1-5/8- inch lap and 6- ACFoam II, III, CR-20 or M- Min. 0.25-inch Dens D-IS, SBS-AA, inch I plywood Polyglass Elastobase inch diameter inch o.c. in H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, (Optional) W-3 at max. 24 or Polyglass tin caps with 12 four, equally Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP -AA BP -AA SBS-TA, -60.0* inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-inch Fiber Roof Board M-OSFA APP-TA shank nails staggered orENRGY-3 oc center rows 32 ga, 1-5/8- -6=inch-o:c7-in-4— inch lap and 6- Min. 2-inch D IS, OB500, (Optional) Min. 19/32- Polyglass Elastobase inch diameter inch o.c. in ACFoam II, III, CR-20 or M- D-IS, One or SBS-SA, W-4 inch plywood or Polyglass tin caps with 12 four, equally H-Shield, H- OSFA, atop (Optional) Additional OB500, SBS-SA more SBS- APP-SA, -60.0 * at max. 24- Elastobase Poly ga. annular ring spaced, Shield CG, fastener layers of base insulation CR-20 or SA or SBS-TA or inch spans shank nails staggered Multi -Max FA3 rows, 7-Inch M-OSFA APP-TA APP-TA center rows or ENRGY-3 oc Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 e' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 'r TRINITY TABLE'3A-2: WOOD DECKS- NEW CONSTRUCTION; REROOF (TEAR" -OFF) ORRECOVER ; SYSTEM TYPE A,2 MECHANICALLYAITACHEDANCHORSHEET; BON DED'INSULATION" BONDE6ROOFCdVER . 't System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 0.25-inch Dens Deck, Polyglass 12-inch o.c. in 4- (Optional) FBC Dens Deck Prime, SECUROCK Min. 19/32- Elastobase or OMG Flat inch lap and 12- Approved, Gypsum -Fiber Roof Board, W 5 Inch plywood Polyglass Bottom Plates inch o.c. in two, ASTM C1289, HA Min. 0.75-inch FescoBoard HA BP -AA (Optional) SBS-AA, SBS- 60.0 at max. 24- Elastobase (square) with equally spaced, type II polyiso- (homogeneous) or min. 0.5- BP -AA TA, APP-TA inch spans Poly Roofgrip #12 staggered center cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Polyglass 12-inch o.c. in 4- (Optional) FBC (Optional) Min. 19/32- Elastobase or OMG Flat inch lap and 12- Approved, Min. 0.25-inch Dens Deck, One or SBS-SA, APP- W 6 inch plywood Polyglass Bottom Plates inch o.c. in two, ASTM C1289, HA Dens Deck Prime, SECUROCK HA SBS-SA more SBS- SA, SBS-TA -60.0 at max. 24- Elastobase (square) with equally spaced, type II polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA inch spans Poly Roofgrip #12 staggered center cyanurate TA rows tXktik WOOD DECKS NIE CONSTRUCTION,`REROOE (TeAR OFF) oR RECOVER . "SYSTEM TYPE B, MECHANICALLY ATTACHED BASE INSULATION, BONDED TOP INSULATION, BONDED ROOF COVER'._, t System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 19/32-inch Min. 1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if (Optional if using W-7 plywood at max. 24 inch H-Shield t #12 1 per (homogeneous) or min. 0.5-inch HA using AA Ply) AA Base) One or BP SBS-AA, SBS-TA, APP-TA 60.0 spans or Pol h or Polytherm MP-3Dekfa MP-3 with TruFast DP ru astTruDP 1.33 ft� Structodek High Density Fiberboard BP more -AA or Roof Insulation APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 C' EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.30.12-R2 for FL16027-RZ Revision 2: 09/25/2017 Appendix 1, Page 5 of 26 TRINITYIERD q � . � :� � ", ;.TABLE iC: ;WC+OD DECKS `NE1N'CONSTRUCfIUN, REROOF Tenn -DOFF oR RECOVER "' � . SYSTEM-� Y, -A17- -ANICALL A�l 1 EDINLILATION 9 COVER .'80NDEDROOF System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Layer (Psf) Type Fasteners Attach Base Ply Ply Cap Ply Min. 19/32-inch (Optional) Min. 0.5-inch Structodek High Density Dekfast Galvalume (Optional if (Optional if using AA W-8 plywood at max. One or more layers, Fiberboard Roof Insulation or min. 0.25- Steel Hex with 1 per 1.33 using AA Ply) Base) One or more BP -AA SBS-AA, SBS-TA, APP- -82.5 24-inch spans any combination, inch Dens Deck, Dens Deck Prime or Dekfast #12 DP ft2 BP -AA orAPP-TA TA loose laid SECUROCK Gypsum -Fiber Roof Board (Optional) Dekfast Galvalume Min. 19/32-inch Steel Hex with W-9 plywood at max. One or more layers, Min. 1.5-inch ENRGY 3, H-Shield or Dekfast #12 DP or I per 1.33 2 SBS-SA (Optional) One or more SBS-SA, APP-SA, SBS- -82.5 any combination, Polytherm ft SBS-SA or APP-TA TA or APP-TA 24-inch spans TruFast MP-3 with loose laid TruFast DP 7 ­W AMON TEAR -OFF) SYSTEM E. ATTACHED INSULATION, ",6r ONDbRobOY�R' System Insulation Lay r(s) Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (psf) Polyglass Elastobase, Polyglass OMG Flat Bottom Plates Min. 19/32-inch One or more layers, Prelim. Elastobase Poly, Polyglass G2 Base, (square) with Roofgrip 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, W-10 plywood at max. any combination Attached CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -52.5 24-inch spans Base, JM Perma-Ply 28, Tamko Glass Dekfast #14 or TruFast staggered center rows or APP-TA APP-TA Base or GAFGLAS #75 MP-3 with TruFast HD Min. 19/32-inch Dekfast Hex with Dekfast 12-inch o.c. in 4-inch lap and 12- SBS-SA, W-11 plywood at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass #14 or TruFast MP-3 with ITruFast-HD inch o.c. in two, equally spaced, One or more APP-SA, -52.5* 24-inch spans any combination Attached Elastobase Poly with poly top surface —staggered-center rows— —SBS-SA— APP-TA Min. 19/32-inch 12-inch o.c. in 4-inch lap and 12- (Optional) One SBS-AA, W-12 plywood at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -60.0 24-inch spans any combination Attached Elastobase Poly (square) with Roofgrip #12 staggered center rows orAPP-TA APP-TA Min. 19/32-inch 12-inch o.c. in 4-inch lap and 12- SBS-SA, FW_ 13 plywood at max. One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates inch o.c. in two, equally spaced, One or more APP-SA, -60.0 * 24-inch spans any combination Attached Elastobase Poly with poly top surface (square) with Roofgrip #12 staggered center rows SBS-SA SBS-TA or I I I I APP-TA I Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6rH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 6 of 26 F)o ,l TRINITY (ERD T: ABLE lE-1 "WOOD DECKS -NEW CbNSTRUCTION oR REROOF (T�►R OFF) ,SYSTEM TYPES "NON -INSULATED MECHANICALLY ATTACHED BASE SHEET; BONDED, ROOF COVER J :" System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note i) Base Fasteners Attach Base Ply Cap Ply (psf) W-14 Min.15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 18-inch o.c. in two, (Optional) BP. -AA or SBS-AA, SBS-TA -45.0' equally spaced, staggered center rows APP TA or APP-TA inch spans W-15 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 9-inch o.c. at 2-inch lap and 12-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA -52.5 inch spans equally spaced, staggered center rows APP-TA or APP-TA Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase (Optional) One or W-16 plywood at max. Poly, Polyglass G2 Base, CertainTeed 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, more BP -AA or SBS-AA, SBS- 60.0 24 inch spans Glasbase, Firestone MB Base, JM Perma- with it ga. annular ring shank nails equally spaced, staggered center rows APP-TA TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS #75 Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 8-inch o.c. in 4-inch lap and 8-inch o.c. in three, (Optional) One or SBS-SA, APP- W-17 plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank nails equally spaced, staggered center rows more SBS-SA or SA, SBS-TA or 60.0 24-inch spans APP-TA APP-TA W-18 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS-TA -90.0 inch spans equally spaced, staggered center rows APP-TA or APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 4-inch o.c. in 4-inch lap and 4-inch o.c. in four, (Optional) One or SBS-SA, APP- W-19 plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank nails. equally spaced, staggered center rows more SBS-SA or SA, 5135-TA or -97.5 24-inch spans APP-TA APP-TA W-26 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-inch o.c. in three, (Optional) BP -AA or SBS-AA, SBS-TA -105.0 equally spaced, staggered center rows APP-TA or APP-TA inch spans Min.19/32-inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SBS-AA, SBS- W-21 plywood at max. Elastobase Poly with 11 ga. annular ring shank nails equally spaced, staggered center rows more BP -AA or TA, APP-TA 112.5 24-inch spans APP-TA Min. 19/32-inch 32 ga., 1-5/8-inch diameter tin caps SBS-SA, APP- W-22 plywood at max. Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails. 6-inch o.c. in 4-inch lap and 6-inch o.c. in four, (Optional) One or SA, SBS-TA or -112.5 24-inch spans Elastobase Polywith of to surface poly P Note: Tin caps are to be rimed with P P equally spaced, staggered center rows q Y p gg more APP-TA APP-TA ASTM D41 primer. Exterior Research and Design, I.I.C. d/b/a Trinity[ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Niemirien, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 7 of 26 \J'TRINITY IERD OFF j SYSTEM TYPE NON, -INSULATED, BASE BQN?�P�R* CVIa System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Pso Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) one or W-1 plywood at max. Poly, Polyglass G2 Base, CertainTeed Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or SBS-AA, SBS- -52.5 24-inch spans Glasbase, Firestone MB Base, JM Perma- or TruFast MP-3 with TruFast HD center rows APP-TA TA, APP-TA Ply 28, Tamko Glass Base or GAFGLAS #75 Min. 19/32-inch 12-inch o.c. in 4-inch lap and 12-inch SBS-SA, APP- W-2 plywood at max. Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- o.c. in two, equally spaced, staggered One or more SBS- SA, SBS-TA or -52.5* Elastobase Poly with poly top surface 3 with TruFast HD SA 24-inch spans center rows APP-TA Min. 19/32-inch 12-inch o.c. in 4-inch lap and 12-inch (Optional) one or Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c. in two, equally spaced, staggered more BP -AA or TA, APP-TA -60.0 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch One or more SBS- SBS-SA, APP- W-4 plywood at max. o.c. in two, equally spaced, staggered SA, SBS-TA or Elastobase Poly with poly top surface Roofgrip #12 SA 24-Inch spans center rows APP-TA TABLE SF WOOD DECKS' NEW 7 CONSTRUCTION NSTRI bkgikppo (Tenn OFF) ,X A SYSTEMTYP F:Ndk�INSULATEDiONDEb ER ROOFCOV� System Roof Cover (Note 15) MDP No. Deck Primer (Psf) Joint Treatment Base Ply Ply Cap Ply Min. 15/32-inch plywood (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA W-5 (Optional) ASTM D41 None SBS SA -90.0 at max. 24-inch spans APP-TA orAPP-TA —Min.-I5/32-inch-plywood— —Plywoodjoints-are-covered-with-4zinch-wide-strips-of-Tr!Built-SA— _(Opfi­onaI)_SB5 SA_o_r _­SBS-SA, _APPSA SBS TA (Optional) ASTM D41 TriBuiltSASBS Base 97.5 at max. 24-inch spans . SBS Base, rolled into place to create continuous bond. APP-TA or APP-TA . Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for F116027-112 Certificate of Authorization #9503 6"EDITION (2017) FOC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26 Q"TRINITYI ERD s " TABLE 2Ac STEEL OR STRUCTURAL CONCRETE DECKS,. -NEW CONSTRUCTION, REROOF_(TEAR-OFF),OR RECOVER ` „- ,SYSTEM TYPE B; MECHANICALLY°ATTACHED BASE INSULATION, _BONDED TOP, INSULATION, BONDED rCOVER, System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 22 ga., type B, Min.1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using SC 1. Grade 33 steel or ACFoam II, ENRGY Dekfast #14, Trufast with Trufast HD or z 1 per 2 ft (homogeneous) or min. 0.5-inch HA (Optional if using AA Base) One or SBS-AA, SBS- 45.0* min. 2,500 psi 3, H-Shield or Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete Polytherm OMG 3 inch Plate OMG Fiberboard Roof Insulation APP-TA with OMD HDD Min. 22 ga., type B, Min. 2-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using SC-2. Grade 33 steel or ACFoam II, ENRGY Dekfast #14, Trufast MP-3 with Trufast HD or z 1 per 4 ft (homogeneous) or min. 0.5-inch HA (Optional if using AA Base) One or SBS-AA, SBS- 45.0* min. 2,500 psi 3, H-Shield or Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete Polytherm OMG 3-inch Galv Plate Fiberboard Roof Insulation APP-TA with OMD HD Min. 22 ga., type B, Min.1.5-inch Dekfast Hex with Min. 0.75-inch FescoBoard (Optional if using Grade 33 steel or 1 per 1.33 (homogeneous) or min. 0.5-inch (Optional if using AA Base) One or SBS-AA, SBS- SC-3. min. 2,500 psi ENRGY 3, H-Shield Dekfast #14 or TruFast ftz Structodek High Density HA AA Ply) BP -AA more BP -AA or TA, APP-TA -90.0 structrual concrete or Polytherm MP-3 with TruFast HD Fiberboard Roof Insulation APP-TA Min. 22 ga., type B, Min. 1.5 inch Dekfast Hex with Min. 0.75-inch FescoBoard BP -AA (Top surface One or more SBS-SA, APP- SC-4. Grade 33 steel or ENRGY 3, H-Shield Dekfast #14 or TruFast 1 per 1.33 z (homogeneous) or min. 0.5-inch HA primed with ASTM layers, SBS-SA or SA, SBS-TA -90.0 min. 2,500 psi or Polytherm MP-3 with TruFast HD ft Structodek High Density D41 primer) APP-TA or APP-TA structrual concrete Fiberboard Roof Insulation TABLE 2B.. STEEL ORSTRUCTURAL CONCRETE DECKS --.NEW CONSTRUCTION, REROOF (TEAR OFF),oa RECOVER a > .. r _ `SYSTEM TYPE C 'MECHANICALLY ATTACHED INSULATION; BONDED ROOF COVER' System Base Insulation Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note i) Layer (psf) Type Fasteners Attach Base Ply Ply Cap Ply Min. 22 ga., type B, (Optional) One or (Optional if (Optional if using AA SC-5. Grade 33 steel or more layers, any Min. 0.5-Inch SECUROCK Gypsum- OMG 3-inch Galvalume Steel 1 per 1.78 using AA Ply) Base) One or more BP- SBS-AA, SBS- -75.0 min. 2,500 psi combination, loose Fiber Roof Board Plate with OMG #14 HD ftz BP -AA AA or APP-TA TA, APP-TA structrual concrete laid Min. 0.5-inch Structodek High Min. 22 ga., type B, One or more layers, Density Fiberboard Roof Dekfast Galvalume Steel Hex with (Optional if (Optional if using AA SC-6. Grade 33 steel or any combination, Insulation or min. 0.25-inch Dens Dekfast #12 (steel only) or #14 or 1 per 1.33 using AA Ply) Base) One or more BP- SBS-AA, SBS- -82.5 min. 2,500 psi loose laid Deck, Dens Deck Prime or TruFast MP-3 with TruFast DP ftz BP -AA AA or APP-TA TA, APP-TA structrual concrete SECUROCK Gypsum -Fiber Roof (steel only) or HD , Board Min. 22 ga., type B, (Optional) Dekfast Galvalume Steel Hex with SBS-AA, SBS- Grade 33 steel or One or more layers, Min. 1.5-inch ENRGY 3, H-Shield Dekfast #12 (steel only) or #14 or 1 per = .33 SBS SA (Optional) One or more TA, SBS-SA, 82 5 SC 7. min. 2,500 psi any combination, or Polytherm TruFast MP-3 with TruFast DP ft SBS-SA or APP-TA APP-TA, APP- structrual concrete loose laid (steel only) or HD I SA Exterior Research and Design, I.I.C. d/b/a Trinity IERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6T" EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 9 of 26 ��TRRINITY I ERD 7, OR STRUCTURAL .DECI SYSTEM TY PE D., A EbNSU�A SHEET; 0 _T NOTE: SU IONI PTt LFQR RECO E1�PP ONS9 j _A X, N System Insulation Layer(s) Base,Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (psf) Min. 22 ga., type B, OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap One or more Polyglass Elastobase, Polyglass (Optional) One or SC-8. Grade 33 steel or min. layers, any Prelim. Elastobase Poly or JM Perma- with Roofgrip #14, Dekfast Hex and 18-inch o.c. in two, more BP -AA or APP- SBS-AA SBS- -4-1-0* 2,500 psi structrual combination Attached Ply 28 with Dekfast #14 or TruFast MP-3 equally spaced, staggered TA TA, APP-TA concrete with TruFast HD center rows Polyglass Elastobase, Polyglass Min. 22 ga., type B, Elastobase Poly, Polyglass G2 OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap Grade 33 steel or min. One or more Prelim. Base, CertainTeed Glasbase, with Roofgrip #14, Dekfast Hex and 12-inch o.c. in two, (Optional) One or SBS-AA, SBS- SC-9. 2,500 psi structrual layers, any Attached Firestone MB Base, JM Perma- with Dekfast #14 or TruFast MP-3 equally spaced, staggered more BP -AA or APP- TA, APP-TA -52.5 combination TA concrete Ply 28, Tamko Glass Base or with TruFast HD center rows GAFGLAS #75 Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap SBS-SA, APP- SC-10. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase Poly with with Roofgrip #14, Dekfast Hex and 12-inch o.c. in two, One or more SBS-SA SA, SBS-TA -5 2.5 2,500 psi structrual combination Attached poly top surface with Dekfast #14 or TruFast MP-3 equally spaced, staggered or APP-TA concrete with TruFast HD center rows Min. 22 ga., type B, One or more OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap (Optional) One or SC-11. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase or with Roofgrip #12 (steel only) or and 12-inch o.c. in two, more BP -AA or APP- SBS-AA, SBS- -60.0 2,500 psi structrual combination Attached Polyglass Elastobase Poly #14 equally spaced, staggered TA TA, APP-TA concrete center rows Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap SBS SA, APP Grade 33 steel or min. Prelim. and 12-inch o.c. in two, SC-12. 2,500 psi structrual layers, any Attached Polyglass Elastobase Poly with with Roofgrip #12 (steel only) or equally spaced, staggered One or more SBS-SA SA, SBS-TA -60.0* combination poly top surface #14 or APP-TA concrete —center-rows— Min. 22 ga., type B, Grade 80 steel or min. One or more Prelim. Dekfast isofast IF-2.375-AT Plates 12-inch o.c. in the 5-inch SBS-TA, APP- SC-13. layers, any TrlBuilt APP Smooth (Optional) APP-TA -82.5 2,500 psi structrual combination Attached with Dekfast #15 HS wide, heat -welded side lap TA concrete min. 22 ga., type B, Grade 80 steel or min. One or more Prelim. Trufast 2.4 in. Barbed Seam 12-inch o.c. in the 6-inch SBS-TA, APP- SC-14. 2,500 psi structrual layers, any Attached TriBuilt APP Smooth Plates with Trufast EHD Fasteners wide, heat -welded side lap (Optional) APP-TA TA -82.5 concrete combination Min. 22 ga., type B, One or more Dekfast Hex with Dekfast #14 or 12-inch o.c. in the 4-inch SC-15. Grade 33 steel or min. layers, any Prelim. TriBullt APP Smooth OMG Flat Bottom Plates with lap and 18-inch o.c. in two, (Optional) BP -AA or SBS-AA, SBS- -112.5 2,500 psi structrual combination Attached OMG Roofgrip #14 equally spaced, staggered APP-TA TA, APP-TA concrete I I I center rows I Exterior Research and Design, U.C. d/b/a Trinity) ERD . Evaluation Report A42970.10.12-R2 for FL16027-112 Certificate of Authorization #9503 6T"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 10 of 26 \JTRINITY (ERD TABLE,3A: STRUCTURAL CONCRETE DECKS='NEW CONSTRUCTION oR RER60F (TEAR -OFF) 3 . . SYSTEIVI TYPE" ON, BONDED ROOF COVER; "- SEE N0� ' FOR BARRIER OPTIONS System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (Psf) SELF-ADHERINE; SYSTEMSINITH . .,>� °BASE.I NSULATION AND OPTIONAL TOP INSULATION OF THE SAME TYPE;_ _ Structural (Optional) Min. 1.5-inch H-Shield or Multi -Max (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 1 concrete ASTM D41 FA3 D-IS base insulation D-IS SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 67.5 Structural (Optional) (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 2 concrete ASTM D41 Min. 1.5 inch ACFoam II or ENRGY 3 D IS base insulation D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 135.0 Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C-3 concrete None Min. 1.5-inch, min. 1.5 pcf Insulfoam D-IS insulation D IS SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 157.5 Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C-4 concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 insulation OB500 SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 120.0 Structural (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-5 concrete None Min. 1.5 inch ENRGY 3 OB500 base insulation OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 127.5 Structural (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-6 concrete None Min. 1.5-inch ACFoam II or H-Shield OB500 base insulation OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -150.0 Structural Min. 1.5-inch ACFoam Il, ENRGY 3, H- (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-7 concrete None Shield or Multi -Max FA3 M-OSFA base insulation M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -232.5 Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C 8 concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 insulation CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -240.0 Structural Min. 1.5-inch ACFoam ll, ACFoam III, (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-9 concrete None ENRGY 3, H-Shield, H-Shield CG , Multi- CR-20 base insulation CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -270.0 Max FA3 or ISO 95+ GL Structural OB (Optional) additional layers(s) of OB (Optional) One or more SBS-SA, APP-SA, C-10 None Min. 2-inch ACFoam II or H-Shield Classic Classic SBS-SA -270.0 concrete (FULL) base insulation (FULL) SBS-SA or APP-TA SBS-TA or APP-TA Structural Min.1.5-inch ACFoam II, ACFoam III, (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-11 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA base insulation HA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -480.0 Multi -Max FA3 SELF -ADHERING SYSTEMS WRH BASEiNSULATION AND COVERBOARD Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 12 concrete None Min. 1.5-inch Multi -Max FA3 D-IS Fiber Roof Board D-IS SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 67.5 Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-13 concrete None Min. 1.5-inch, min. 2.0 pcf Insulfoam D-IS Deck Prime D-IS SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 120.0 Structural Min. 2-inch ACFoam II, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 14 concrete None Shield D IS Fiber Roof Board D-IS SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 247.5 Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-15 concrete None Min. 1.5 inch ENRGY 3 OB500 Deck Prime OB500 SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 127.5 Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 11 of 26 F)o �I TRINITY1ERD TABLE3A $TRUCTURALCONCRETEDECKS-NEW CONSTRUCTIONoRREROOF(TEAR-OF_F) 3 ` SYSTEM TYPE A 1 BONDED INSULATION, BONDED ROOFCOVER $EE NOTE 16 FOR VAPOR BARRIER ORTIONS .zq System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf) Structural Min. 1.5-inch ACFoam II, H-Shield or Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-16 None OB500 OB500 SBS-SA -150.0 concrete ISO 95+GL Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 2-inch ACFoam II, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 17 concrete None Shield OB500 Fiber Roof Board OB500 SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 247.5 Structural Min. 1.5-inch ACFoam II, ENRGY 3, H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-18 concrete None Shield or Multi -Max FA3 M-OSFA Fiber Roof Board M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 232.5 Structural Min. 2-inch ACFoam ll, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-19 concrete None Shield M-OSFA Fiber Roof Board M-OSFA SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 247.5 C-20 Structural None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch Dens Deck, Dens CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, -240.0 concrete Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA Min.1.5-inch Ultra -Max or Multi -Max Structural FA-3, min. 1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-$A, C-21 concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR-20 SBS SA SBS-SA or APP-TA SBS-TA or APP-TA 240.0 CG or ENRGY 3 Structural Min. 2-inch ACFoam II, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 22 concrete None Shield CR-20 Fiber Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 247 5 Structural OB Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more SBS-SA, APP-SA, C-23 concrete None Min. 2-inch ACFoam II or H-Shield Classic Fiber Roof Board Classic SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -350.0 (FULL) (FULL) Structural Min. 1.5-inch ACFoam II, ACFoam III, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-24 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA -Fiber-Roof-Board HA SBS-SA -SBS=SA or APP-T -SBS7A or APP=TA -350.0- -Multl;Mz x FA3 "`ASPHALT AND/ORTORCHAPPLIEOSYSTEMS "' �`�'.•"' . ... .`�?,"'" ; #"`" _ Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C 25 concrete None Min. 2-inch ACFoam II or H-Shield D-IS Fiber Roof Board D-IS BP -AA BP -AA SBS-AA 225.0 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-26 None Min. 2 inch ACFoam II or H Shield D-IS D-IS APP-TA APP TA 232.5 concrete Fiber Roof Board APP-TA Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or -more C 27 None Min. 2-inch ACFoam II or H-Shield OB500 OB500 BP -AA SBS-AA -225.0 concrete Fiber Roof Board BP -AA Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C 28 concrete None Min. 2-inch ACFoam II or H-Shield OB500 Fiber Roof Board OB500 APP-TA APP-TA APP-TA -232.5 Structural Min. 0.25-inch SECUROCK Gypsum (Optional) One or more C-29 concrete None Min. 2-inch ACFoam II or H-Shield M-OSFA Fiber Roof Board M-OSFA BP -AA BP AA SBS AA 225.0 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-30 concrete None Min. 2-inch ACFoam II or H-Shield M-OSFA Fiber Roof Board M-OSFA APP-TA APP-TA APP-TA -232.5 Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-132 for FL16027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 12 of 26 -,.1 TRINITY ERD TABLE 3Ac' STRUCTURAL CONCRETE DECKS— NEW CONSTRUCTION OR REROOF'(TEAR—OFF) ,SYSTEM TYPE A 1. BONDED INSULATION, BONDED ROOFCOVER„ " NOTE 1;6 FOR VAPOR BARRIER OPTIONS Sit System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf) Min. 1.5-inch Ultra -Max or Multi -Max Structural FA-3, min. 1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-31 concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR 20 BP -AA BP -AA SBS-AA 225.0 CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max Structural FA-3, min.1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C 32 concrete None 1.0-inch ISO 95+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR 20 APP TA APP TA APP TA 232.5 CG or ENRGY 3 C-33 Structural None (Optional) Min. 2-inch ACFoam II or H- OB Classic Min. 0.25-inch SECUROCK Gypsum- OB Classic BP -AA (Optional) One or more SBS-AA -225.0 concrete Shield (FULL) Fiber Roof Board (FULL) BP -AA Structural (Optional) Min. 2-inch ACFoam II or H- OB Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more C-34 concrete None Shield Classic Fiber Roof Board Classic APP-TA APP-TA APP-TA -232.5 (FULL) (FULL) Structural Min.1.5-inch ACFoam II, ACFoam III, Min. 0 inch SECUROCK Gypsum- (Optional) One or more C-35 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA of Board Fiber Roof o HA BP AA BP -AA SBS-AA -225.0 Multi -Max FA3 Structural Min. 1.5-inch ACFoam II, ACFoam III, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-36 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Fiber Roof Board HA APP-TA APP TA APP-TA -232.5 Multi -Max FA3 (Optional if (Optional if using AA C-37 Structural ASTM D41 Min. 0.75-inch FescoBoard HA None N/A using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -277.5 concrete (homogeneous) One or more APP-TA BP -AA AA or APP-TA (Optional if Structural Min. 1.5-inch ACFoam II, ACFoam III, using AA Ply) (Optional if using AA SBS-AA, SBS-TA, C-38 ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.75-inch Fesco Board HA Base) One or more BP- -290.0 concrete Multi -Max FA3 One or more O AA or APP-TA APP-TA (Optional if (Optional if using AA C 39 Structural ASTM D41 Min. 0.5-inch Structodek High Density HA None N/A using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, 285.0 concrete Fiberboard Roof Insulation One or more AA or APP-TA APP TA BP AA (Optional if Structural Min. 1.5=inch ACFoam II, ACFoam III, Min. 0.5-inch Structodek High using AA Ply) (Optional if using AA SBS-AA, SBS-TA, C 40 ASTM D41 ENRGY 3, H-Shield, H Shield CG or HA HA Base) One or more BP- 480.0 concrete Density Fiberboard Roof Insulation One or more APP-TA Multi -Max FA3 BP -AA AA or APP-TA Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization #9503 e" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 13 of 26 TRINITY I ERD DECKS`;,TABLE 3A STRUCTURAL CONCRETE BONDED E FORwVAPO0ARRIER;OPTIONS System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (Pso (Optional if Min. 1.5-Inch ACFoam 11, ACFoam 111, (Optional if using AA Structural using AA Ply) SBS-AA, SBS-TA, C-41 ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.25-inch Dens Deck Prime HA Base) One or more BP- -480.0 concrete Multi -Max FA3 One or more AA or APP-TA APP-TA BP -AA (Optional if (Optional if Using AA Structural using AA Ply) SBS-AA, SBS-TA, C-42 ASTM D41 Min. 0.25-Inch Dens Deck Prime HA None N/A Base) One or more BP- -510.0 concrete One or more AA or APP-TA AP.P-TA BP -AA TABLE 3B ,'' TWd,6RALb6NdRft -6k& NEWStkbdlPNb,iih t 660 06 SYSTEM TYFEFN04*Su 36BASH60NDE 0 FQ AR"�f"` System No. Deck Primer Roof Cover (Note IS) MDP Base Ply Ply Cap Ply (Psf) C-43 Structural concrete ASTM D41 SBS-SA (Optional) SBS-SA or APP-TA SBS-SA, APP-SA, SBS-TA or APP-TA -315.0 F C-44 Structural concrete ASTM D41 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA 622.5 Exterior Research and Design, LLC. d/b/a Trinity[ ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6rH EDITION (2017) FBC NON-HVIHIZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 14 of 26 ,-JI RINITY ERD TABLE"4A: LIGHTWEIGHT CONCRETE DECKS —NEW CONSTRUCTION 0R,REROOF (TEAR=OFF) , 9 , SYSTEM TYPE A-1: BONDED INSULATION, BONDED ROOF COVER System Deck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) Concrete (Note 14) (Psf) SELF -ADHERING SYSTEMS WITH BASE INSULATION AND OPTIONALTOP INSULATION OF THE.SAML'TYPE:, _ — _ _ . Structural Min. 200 psi, min 2- (Optional) Additional (Optional) One or SBS-SA, APP- LWC 1 Min.1,5 inch, min. 2.0 pcf Insulfoam OB500 OB500 SBS-SA 120.0 concrete inch Elastizell layers of base insulation more SBS-SA SA (Optional) One or SBS-SA, APP- Structural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL (Optional) Additional LWC-2 concrete inch Elastizell or H-Shield 013500 layers of base insulation OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 APP-TA or APP-TA Structural Min. 200 psi, min. (Optional) Additional (Optional) One or SBS-SA, APP- LWC 3 concrete 2-inch Elastizell Min. 2.0 pcf Insulfoam CR 20 layers of base insulation CR-20 SBS-SA more SBS-SA SA 180.0 Structural Min. psi, min. Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-4 ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 concrete 2-Inch Elastizell layers of base insulation FA3 APP-TA or APP-TA Structural Min. 200 psi, min. (Optional) Additional (Optional) One or'. SBS-SA, APP- LWC-5 concrete 2-inch Celcore or Min. 2.0 pcf Insulfoam CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA SA 222.5 Mearlcrete Structural Min. 200 psi, min. Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-6 2-inch Celcore or ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 concrete Mearlcrete FA3 layers of base insulation APP-TA or APP-TA SELF -ADHERING SYSTEMS WITH BASEJNSULATION ANDC OVERBOARD _ . ... _ .. ... ...A .. ".. .. a, _ _ .. _ Structural Min. 200 psi, min 2- Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-7 concrete inch Elastizell Min. 1.5-inch, min. 2.0 pcf Insulfoam OB500 Gypsum -Fiber Roof Board OB500 SBS-SA more SBS-SA or SA, SBS-TA -120.0 APP-TA or APP-TA Structural Min. 200 psi, min 2- Min.1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-8 concrete inch Elastizell or H-Shield OB500 Gypsum -Fiber Roof Board OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 APP-TA or APP-TA Structural Min. 200 psi, min. Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- LWC-9 ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 concrete 2-inch Elastizell FA3 or min. 2.0 pcf Insulfoam Gypsum Fiber Roof Board APP-TA or APP-TA Min. 200 psi, min. Min.1.5-inch ACFoam II, ACFoam III, ENRGY 3, (Optional) One or SBS-SA, APP- structural Min. 0.25-inch SECUROCK LWC-10 concrete 2-inch Celcore or ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 Mearlcrete FA3 or min. 2.0 pcf Insulfoam APP-TA or APP-TA .: 'ASPHALT AND/OBTORCH APPLIED SYSTEMS (Optional) One or Strudural Min. 200 psi, min 2- Min. 1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL Min. 0.25-inch SECUROCK BP�' SBS-AA, SBS- LWC-11 concrete inch Elastizell or H-Shield OB500 Gypsum -Fiber Roof Board OB500 APP-TA more BP -AA or APP- TA, APP-TA _225.0 TA Structural Min. 200 psi, min. Min.1.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK BP -AA (Optional) One or SBS-AA, SBS- LWC-12 concrete 2-inch Elastizell ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 APP-TA more BP -AA or APP- TA, APP-TA -180.0 FA3 or min. 2.0 pcf Insulfoam TA Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-112 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 15 of 26 NEW It TABLE 4A LIGHT` kldkfed ekETEDECKS,- 0NStkI1Jdl0Nok:RER60F'(Tt4F FF MTy' bEQ� 4s U I ROOF COVER. n �BONOEO",RO System Deck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply cap Ply No. (Note 1) Concrete (Note 14) (psf) Min. 200 psi, min. Min. 1.5-inch ACFoam 11, ACFoam III, ENRGY 3, (Optional) One or Structural Min. 0.25-inch SECUROCK BP -AA, SBS-AA,SBS- LWC-13 2-inch Celcore or ISO 95+ GL, H-Shield, H-Shield CG, Multi -Max CR-20 CR-20 more BP -AA or APP_ I -222.5 concrete Gypsum -Fiber Roof Board APP-TA TA, APP-TA MearIcrete . FA3 ormin. 2.0pcfInsuIfoarn TA m� nXI, SYSTEM TYPE*CALL ATTACHED BONDED iNsULATIOMACNDED R OFCOVE FC System Deck Lightweight Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP Type Fasteners 1 Attach Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) Concrete (Note 14) (Psf) Min. 1.5-inch 7-inch o.c. at (Optional) Min. Thermaroof Composite, Min. 22 ga., 4-Inch lap and 1.5-Inch Polytherm Composite or (Optional if Type B, Min. 300 psi (Optional if using AA Base) LWC-14 vented steel Approved GAFGLAS OMG CR 7-inch o.c. in ACFoam 11, H- HA min. 0.5-inch Structodek HA using AA Ply) One or more SBS-AA, SBS- -45.0 at max. 5 ft cellular LWC #75 BSF two, equally Shield, Multi- High Density Fiberboard BP -AA BP -AA or APP- TA, APP-TA spaced center Max FA3 or Roof Insulation or min. spans rows Polytherm 0.75-inch FescoBoard TA I I (homogeneous) 7-inch o.c. at Min. 22 ga., 4-inch lap andGAFGLAS Min. 1.5-inch Type B, Min. 300 psi ACFoam 11, H- (Optional) One SBS-SA, APP- LWC-15 vented steel Approved OMG CR 7-inch o.c. in Shield, Multi- HA None N/A SBS-SA or more SBS-SA SA, SBS-TA -45.0 at max. 5 ft cellular LWC #75 BSF two, equally Max FA3 or _or_APP=TA- -spans­­ —spaced-center— Polytherm —or-APP--TA rows Exterior Research and Design, U.C. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL16027-112 Certificate of Authorization #9503 EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 16 of 26 \-.! TRINITY I ERD TABLE4C:-LIGHTWEIGHT CONCRETE DECKS = NEW CONSTRUCTION ,ORRER00F(TEAR-OFF) SYSTEM TYPE E.'MECHANICALLY ATTACHED BASE SHEET; BONDED ROOF=COVER Base Sheet (Note A below) Roof Cover (Note 15) System Deck Lightweight Concrete (Note 14) MDP IPsfl Type No. (Note 1) Fasteners Attach Base Ply Cap Ply (Note A) `GENERIC' CELLULAR'LIGHTWEIGHi1NSULATINGCONCRETE a 4 -_- Min. 300 psi, min. 2-inch thick cellular Min. 22 ga., type B steel LWC. Note: To qualify the LWIC under this 7-inch o.c. in a 3-inch lap and 7-inch o.c. in (Optional) SBS-AA, APP- LWC-16 at max 5 ft spans or assembly, an OMG CR BPF shall achieve B3 OMG CR BPF two, equally spaced, staggered rows in the One or more TA -45.0 structural concrete an average withdrawal of 53 Ibf when field of the sheet BP -AA tested per TAS 105 orANSI/SPRI FX-1 CELCORii CELLULAR LIGHTwildti INSU EATING CONCRETE: Min. 0.0179-inch Tensilform S-75 or min. Trufast FM-90 or 8-inch o.c. in a 3-inch lap and 16-inch o.c. in One or more LWC-17 0.0205-inch Tensilform Min. 200 psi, min. 2-inch thick Celcore B1, B2, B3 or B7 OMG CR BPF two, equally spaced, staggered rows in the BP AA SBS-AA -37.5 75 at max. 5 ft spans or field of the sheet structural concrete Min. 22 ga., type B steel Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more LWC-18 at max 5 ft spans or Min. 200 psi, min. 2-inch thick Celcore Bl through B12 OMG CR BPF two, equally spaced, staggered rows in the BP AA SBS-AA -45.0 structural concrete field of the sheet Min. 26 ga., type HF BS, 62, B3, 134, 9-inch o.c. in a 3-inch lap and 9-inch o.c. in One or more LWC-19 steel at max 5 ft spans Min. 225 psi, min. 2-inch thick Celcore MF B7, 68, BSO, B31 OMG CR BPF two, equally spaced, staggered rows in the BP AA SBS-AA -45.0 or structural concrete or 612 field of the sheet Min. 22 ga., type B steel B1, 62, B3, 134, 7-inch o.c. in a 3-inch lap and 14-inch o.c. in One or more LWC-20 at max 6 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF 87, 68, B30, B11 OMG CR BPF two, equally spaced, staggered rows in the BP AA SBS-AA -45.0 structural concrete orB12 field of the sheet Min. 22 ga., type B steel Bi, 62, B3, 84, 9-inch o.c. in a 3-inch lap and 9-inch o.c. in One or more LWC-21 at max 6 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B7, B8, B10, B11 OMG CR BPF two, equally spaced, staggered rows in the BP AA SBS-AA -45.0 structural concrete or B12 field of the sheet Min. 22 ga., type B steel Trufast Twin Loc- 9-inch o.c. in a 4-inch lap and 18-inch o.c. in One or more SBS-AA, SBS- LWC-22 at max 5 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF B1 or B2 Nail two, equally spaced, staggered rows in the BP -AA or APP- TA or APP-TA -45.0 structural concrete field of the sheet TA Min. 22 ga., type B steel 62 (with poly- Trufast Twin Loc- 9-inch o.c. in a 4-inch lap and 18-inch o.c. in One or more SBS-SA, APP- LWC-23 at max 5 ft spans or Min. 225 psi, min. 2-inch thick Celcore MF film top surface) Nail two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel 8-inch o.c. in a 4-inch lap and 8-inch o.c. in BP -AA or APP- SBS-AA, SBS- LWC-24 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF B2 Trufast FM-90 three equally spaced, staggered center rows TA TA or APP-TA -60.0 structural concrete Min. 22 ga., type B steel 62 (with poly- 8-inch o.c. in a 4-inch lap and 8-inch o.c, in One or more SBS-SA, APP- LWC-25 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF film top surface) Trufast FM-90 three equally spaced, staggered center rows SBS-SA or SA, SBS-TA -60.0 structural concrete APP-TA or APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity(ERD Evaluation Report A42970.30.12-R2 for FL36027-112 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 17 of 26 -,.I TRINITY JERD TABLE 4C LIGHTWEIGHT CONCRETE DECKS NEW CONSTRt1CT10N oit REROQF (TEARrOFF) TYPE E ;MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF;COVER ISYSTEM Base Sheet (Note A below) Roof Cover (Note 15) System Deck Lightweight Concrete (Note 14) MOP Type (Note i) Fasteners Attach Base Ply Cap Ply (psf) (Note A) Min. 22 ga., type B steel 7-inch o.c. in a 3-inch lap and 7-inch o.c. in LWC-26 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore Bl through B12 Trufast FM-90 or two, equally spaced, staggered rows in the One or more -AA SBS-AA -75.0 structural concrete OMG CR BPF field of the sheet BP Min. 22 ga., type B steel Polyglass 10-inch o.c. in a 4-inch lap and 10-inch o.c. in (Optional) BP- SBS-AA, SBS- LWC-27 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore MF Elastobase Poly Trufast FM-260 three equally spaced, staggered center rows AA or APP-TA TA, APP-TA -90.0 structural concrete EWSTRELLGELLULARLIGHi1NEfGHT.INSULA ,. .. , ,. INGCONR - _ CETE.. .. Min. 0.0179-inch Tensilform S-75 or min. Min. 200 psi, min. 2-inch thick Elastizell Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-r A, SBS- LWC-28 0.0205-inch Tensilform BS through B12 in two, equally spaced, staggered rows in the BP -AA or APP- -30.0 75 at max. 5 ft spans or Range II OMG CR BPF field of the sheet TA TA or APP-TA structural concrete Min. 0.0179-inch Tensilform S-75 or min. Min. 200 psi, min. 2-inch thick Elastizell 82 (with poly- Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-SA, APP- LWC-29 0.0205-inch Tensilform Range II film top surface) OMG CR BPF in two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -30.0 75 at max. 5 ft spans or field of the sheet APP-TA or APP-TA structural concrete Min. 22 ga., type B steel Min. 200 psi, min. 2-inch thick Elastizell Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more SBS-AA, SBS- LWC-30 at max 5 ft spans or B1 through B12 two, equally spaced, staggered rows in the BP -AA or APP- -45.0 structural concrete Range II OMG CR BPF field of the sheet TA TA or APP-TA Min. 22 ga., type B steel Min. 200 psi, min. 2-inch thick Elastizell B2 (with per= Trufast FM 90_or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One One or more SBS-SA, APP- _I,WC_31— _atmax5_ft.spans.or Range II film top surface) OMG CR BPF two, equal y spaced, staggered rows in the or SA, SBS-TA -45.0 structural concrete field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel Min. 350 psi, min. 2-inch thick Elastizell Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SBS-AA, SBS- LWC-32 at max 5 ft spans or with Zell -Crete Fibers, supple -mentally B2 Nails (min.1.8- three, equally spaced, staggered rows in the One or more TA, SBS-SA, -60.0 structural concrete attached with Roofgrip #21 and 3-inch inch) field of the sheet BP -AA APP-TA or plates at 1 per 8 ft2 APP-SA Min. 350 psi, min. 2-inch thick Elastizell Min. 22 ga., type B steel with Zell -Crete Fibers, supple -mentally 62 (with poly- Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SBS-SA or SBS-SA, APP- LWC-33 at max 5 ft spans or Nails (min.1.8- three, equally spaced, staggered rows in the SA, SBS-TA -60.0 attached with Roofgrip #21 and 3-inch film top surface) APP-TA structural concrete inch) field of the sheet or APP-TA plates at 1 per 8 ft2 -SMEARLCRETECELLULARI.IGHTWEIG.HTINSULATING,CONCR_ETE„ „ Min. 24 ga., type B steel 7.5-inch o.c. in a 3-inch lap and 10-inch o.c. Trufast FM-90 or One or more LWC-34 at max 5 ft spans or Min. 200 psi, min. 2-inch thick Mearlcrete B3 through B12 in two, equally spaced, staggered rows in the SBS-AA -30.0 structural concrete OMG CR BPF field of the sheet BP AA Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization #9503 eH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 18 of 26 \I TRINI7YIERD TABLE 4Ce'LIGHTVVEIGHT CONCRETE DECKS` -NEW CONSTRUCTION oR'REROOF (TEAR -OFF) r SYSTEMTYPE'E 'MECHANICALLY,ATTACHED" BASE SHEET, BONDEDROOF"COVER P' Base Sheet (Note A below) Roof Cover (Note 15) System Deck Lightweight Concrete (Note 14) MDP Type No. (Note 1) Fasteners Attach Base Ply Cap Ply (Pso (Note A) Min. 22 ga., type B steel Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-AA, SBS- LWC-35 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete B1, B2 or B12 OMG CR BPF two, equally spaced, staggered rows in the BP -AA or APP- TA or APP-TA -45.0 structural concrete field of the sheet TA Min. 22 ga., type B steel 62 (with poly- Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-36 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete film top surface) OMG CR BPF two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete field of the sheet APP-TA' or APP-TA Min. 22 ga., type B steel B1, B2, B3, B7 or Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-AA, SBS- LWC-37 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete B11 OMG CR BPF two, equally spaced, staggered rows in the BP -AA or APP- TA or APP-TA -52.5 structural concrete I field of the sheet TA Min. 22 ga., type B. steel B2 (with poly- Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-38 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Mearlcrete film top surface) OMG CR BPF two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -52.5 structural concrete field of the sheet APP-TA or APP-TA A. Base Sheets options are coded as follows: ➢ 131: Polyglass G2 Base; 62: Polyglass Elastobase or Polyglass Elastobase Poly; 133: GAFGLAS #75; 134: GAFGLAS Stratavent Noiloble Venting Bose Sheet; 135: GAFGLAS Ply 4; B6: GAFGLAS FlexPly 6; 137: JM Perma Ply No. 28; 138: JM Vensulation; B9: JM GlasPly IV; B10: JM GlasPly Premier; B11: Tamko Glass -Bose; B12: Tamko Vapor -Chan Exterior Research and Design, LLC. d/b/a Trinity[ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 C" EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 19 of 26 \,1 TRINITY (ERD ' " � �-' `,,> �' ' � y„,° ,� ,TABLE 5A CEMENTITIOUS 1NOOD FIBER DECKS NEW CONSTRUCTIQN oR RERQOF. TEnR-OFF , ,: „ s SYSTEM TY?E 1 INSULATION, BONDED ROOF COVER` A BONDED System Deck Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) Min. 1.5-inch ACFoam II, Min. 0.25-inch Dens Deck, Dens Deck Prime, (Optional) One or Min. 2.5-inch Tectum D-I5 or SECUROCK Gypsum -Fiber Roof Board or min. 0.5- D-IS or SBS-AA, SBS-TA, CWF-1 Plank or Tectum LS Plank ISO ld, OB500 inch Structodek High Density Fiberboard Roof OB500 BP -AA more BP AA or APP- APP-TA 45.0 therm, ENRGH-ShI Polytherm, ENRGY-3 TA Insulation Min. 1.5-inch ACFoam II, (Optional) One or CWF-2 Min. 2.5-inch Tectum ISO 95+GL, H-Shield, D-IS or Min. 0.25-inch Dens Deck, Dens Deck Prime, D-IS or SBS-SA or more SBS-SA or SBS-TA, SBS-SA, -45.0 Plank or Tectum LS Plank OB500 SEW ROCK Gypsum -Fiber Roof Board OB500 APP-TA APP-TA, APP-SA Polytherm, ENRGY-3 APP-TA Min. 1.5-inch ACFoam II, Min. 0.25-inch Dens Deck, Dens Deck Prime, (Optional) One or CWF-3 Min. 2.5-inch Tectum ISO 95+GL, H-Shield, CR-20 SECUROCK Gypsum -Fiber Roof Board or min. 0.5- CR-20 BP -AA more BP -AA or APP- SBS-AA, SBS-TA, -52.5 Plank or Tectum LS Plank Polytherm, ENRGY-3 inch Structodek High Density Fiberboard Roof TA APP-TA Insulation Min. 1.5-inch ACFoam II, (Optional) One or CWF-4 Min. 2.5-inch Tectum ISO 95+GL, H-Shield, CR-20 Min. 0.25-inch Dens Deck, Dens Deck Prime, CR-20 SBS-SA or more SBS-SA or SBS-TA, SBS-SA, 52.5 Plank or Tectum LS Plank SECUROCK Gypsum -Fiber Roof Board APP TA APP TA, APP-SA Polytherm, ENRGY-3 APP-TA Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 d"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 20 of 26 C)o ,J I RINITY (ERD ` TABLE 56. ,CEMENTITIOUS WOOD FIBER DECKS NEW CONSTRUCTION, OR REROOF (TEAk-OFF) - SYSTEM TYPE A-2:' MECHANICALLY ATTACHED ANCHOR -SHEET, BONDED INSULATION, BONDED ROOF WER , System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fastener Attach Type Attach Type Attach Base Ply Ply Cap Ply (psf) Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Min. 2.5-inch Polyglass 9-inch o.c. in 4-inch ACFoam II, ACFoam Deck Prime, SECUROCK Gypsum- (Optional) Elastobase, Trufast lap and 12-inch o.c. Fiber Roof Board, Min. 0.75-inch SBS-AA, CWF-5 Tedum Plank Polyglass Inuldek in two, equally III, H- HA FescoBoard (homogeneous) or HA BP -AA One more SBS-TA, -30.0* or Tedum LS Elastobase Poly, Loc-Nail spaced, staggered ENRGY Shield, ENRGY 3, ShieISOld, min. 0.5-inch Structodek High BP -AA or A APP-TA Plank Polyglass G2 Base center rows Polyor Multi- Density Fiberboard Roof APP-TA Ferm Max FA3 Max Insulation Polyglass 9-inch o.c. in 4-inch Min.1.5-inch Min. 2.5-inch Elastobase, Trufast lap and 12-inch o.c. ACFoam II, ACFoam Min. 0.25-inch Dens Deck, Dens SBS-SA (Optional) SBS-TA, CWF-6 Tectum Plank Polyglass Inuldek in two, equally III, ISO95+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -30.0* or Tectum LS Elastobase Poly, Loc Nail spaced, staggered Shield, ENRGY 3, Fiber Roof Board TA SBS-SA or APP-TA, Plank Polytherm or Multi APP-TA APP-SA Polyglass G2 Base center rows Max FA3 Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Min. 2.5-inch Polyglass 9-Inch o.c. in 4-inch ACFoam II, ACFoam Deck Prime, SECUROCK Gypsum- (Optional) Elastobase, Trufast lap and 18-inch o.c. Fiber Roof Board, Min. 0.75-inch SBS-AA, CWF-7 Tectum Plank Polyglass Twin in two, equally III, ISO95+GL, H- HA FescoBoard (homogeneous) or HA BP -AA One or more SBS-TA, -45.0* or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, min. 0.5-inch Strudodek High BP -AA or APP-TA Plank Polyglass G2 Base center rows Polytherm or Multi- Density Fiberboard Roof APP-TA Max FA3 Insulation Polyglass 9-inch o.c. in 4-inch Min.1.5-inch Min. 2.5-inch Elastobase, Trufast lap and 18-inch o.c. ACFoam II, ACFoam Min. 0.25-inch Dens Deck, Dens SBS-SA (Optional) SBS-TA, CWF-8 Tedum Plank Polyglass Twin in two, equally III, ISO95+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -45.0* or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, Fiber Roof Board TA SBS-SA or APP-TA, Plank Polytherm or Multi- APP-TA APP-SA Polyglass G2 Base center rows Max FA3 Exterior Research and Design, U.C. d/b/a Trinity( ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 e" EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-RZ Revision 2: 09/25/2017 Appendix 1, Page 21 of 26 a . TABLE 5C `CEMENTITIOUS WOODFIBER DECKS-:NEW`CONSTRUCTION 'REROOF. TeAR OFF oR RECOVER err',: -„., ,. , �,,,. ' r SYSTEMTYPEB MECHANICALLY ATTACHED INSULATION;,,BONDEDTOP.INSULATION,BOfYDEDROOF:COVER r;'„ p BASE _ ,. _ ., ..., ems. s, .. System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck (Note i) (Psf) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply Min. 2.5-inch Min. 2-inch H- OMG Polymer GypTec Plate Min. 0.5-inch Structodek (Optional using (Optional if using AA SBS-AA, CWF-9 Tectum Plank or Shield or with Polymer GypTec orTruFast 1 per 4 ft2 High Density Fiberboard HA Base) One or more BP -AA SBS-TA, -45.0• Tectum LS Plank Polytherm TL 3 in. Plate with TL Fastener Roof Insulation AA Ply) BP -AA or APP-TA APP-TA TABLE SD GEMENTITIOUS WOOD FIBER DECKS NEW CONSTRUCTION, RER00F TepR OFF oR RECOVER SYSTEM TYPE C. MECHAN( ((t 'ATTACHED`INSULATION, BONDuED ROOF;COVEW__ System Top Insulation Layer Roof Cover (Note 15) MDP Deck (Note i) Base Insulation Layer Type Fasteners Attach Base Ply Ply Cap Ply No. (Pso (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Prime - Min. 2.5-inch (Optional if using AA SBS-AA, WF-10 Tectum Plank or more layers, any or SECUROCK Gypsum -Fiber Roof Board or Trufast Twin Loc-Nails 2 1 per 2 ft (Optional if using Base) One or more BP -AA SBS-TA, -45.0y Tectum LS Plank combination, loose min. 0.5-inch Structodek High Density (min. 1-inch embedment) AA Ply) BP -AA or APP-TA APP-TA laid Fiberboard Roof Insulation - TABLE 5E `,'CEMENTITIOUS-WOOD ABER&CA-NEW CONSTRUCTION'oR REROOF TeAR-OFF ,SYSTEM TYPE E NON -INSULATED, MECHANICALLY ATTACHED,BASE SHEET, BONDED RO,OFCOVER,: System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note i) (Psf) Base Fasteners Attach Base Ply Cap Ply Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Inuldek 9-inch o.c. in 4-inch lap and 12-inch o.c. in two, (Optional) One or SBS-AA, SBS-TA, CWF-11 orTectum LS Plank Poly, Polyglass G2 Base Loc-Nail equally spaced, staggered center rows more BP -AA or APP-TA APP-TA 30.0 FF-12Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Twin Loc- _9Aac ch-o.c.-inA-inch-lap-and-18-inch-o -in-two— -(Optional) One or SBS-AA, SBS-TA, „ F-12 orTectum LS_P1ank -Poly,-Polyglass-G2-Base Nails equally spaced, staggered center rows more BP -AA or APP-TA APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 22 of 26 F)o `1 TRINITY I ERD TABLE 6A GYPSUM DECKS- REROOF (TEAR OFF) : :': SYSTEM TYP,EA-1: BONDED INSULATION, BONDED ROOF COVER System Base Insulation Layer Top Insulation layer Roof Cover (Note 15) MDP No. Deck (Notes 1 & 12) (Psq Type Attach Type Attach Base Ply Ply Cap Ply G-1 Existing, sound poured gypsum Min. 2.0 pcf, Insulfoam OB500 (Optional) additional layers(s) of base OB500 SBS-SA (Optional) One SBS-SA, APP-SA -112.5 or gypsum plank deck insulation or more SBS-SA (Optional) One G-2 Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or OB500 (Optional) additional layers(s) of base OB500 SBS-SA or more SBS-SA SBS-SA, APP-SA, -112.5 or gypsum plank deck H-Shield insulation or APP-TA SBS-TA or APP-TA G 3 Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3 or OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 SBS-SA (Optional) One or more SBS-SA SBS-SA, APP-SA, 112.5 or gypsum plank deck H-Shield or min. 2.0 pcf, Insulfoam Fiber Roof Board or APP-TA SBS-TA or APP-TA (Optional) additional layers(s) of base (Optional) One G-4 Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ENRGY 3, M-OSFA insulation and/or min. 0.25-inch M-OSFA SBS-SA or more SBS-SA SBS-SA, APP-SA, -202.5 or gypsum plank deck H-Shield or Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board or APP-TA SBS-TA or APP-TA G-5 Existing, sound poured gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers of base CR-20 SBS-SA (Optional) One SBS-SA, APP-SA -240.0 or gypsum plank deck insulation or more SBS-SA (Optional) One G-6 Existing, sound poured gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 SBS-SA or more SBS-SA 565-SA, APP-SA, -240.0 or gypsum plank deck Fiber Roof Board or APP-TA SBS-TA or APP-TA (Optional (Optional if using Existing, sound poured gypsum Min. 0.25-inch Dens Deck, Dens if using AA Base) One or SBS-AA, SBS-TA, G-7 or gypsum plank deck Deck Prime SECUROCK Gypsum- CR-20 None N/A AA Ply) more BP -AA or APP-TA 245.0 ard Fiber Roof Board BP -AA APP-TA Existing, sound poured gypsum Min. 1.5-inch ACFoam II, ACFoam III, (Optional) additional layers(s) of base (Optional) One 565-SA, APP-SA, G-8 ENRGY 3, H-Shield, H-Shield CG or CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA or more SBS-SA -257.5 or gypsum plank deck Multi -Max FA3 SECUROCK Gypsum -Fiber Roof Board or APP-TA SBS TA or APP-TA Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 C" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 23 of 26 4TRINITYIE'Rb GYPSUM Dk-ks-- kgRpbF# NICAL A H U T N �BONDED RO "!Ly,'� HI( ­6 6�S BONDED INS'' LA' 60CdVER SYSTEM7,YPE �C"A N HEET� Anchor Sheet Base Insulation Top Insulation Roof Cover (Note IS) System Deck MDP Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) (psf) (Note 11) 9-inch o.c. in 4- Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens Existing, sound Polyglass Trufast FM- inch lap and 18- ACFoam 11, ACFoam Deck Prime, SECUROCK Gypsum- (Optional) poured gypsum Elastobase, 75 or FM- inch o.c. In two, III, ISO95+GL, H- Fiber Roof Board, Min. 0.75-inch One or more SBS-AA, G-9 or gypsum Polyglass 90 or Twin equally spaced, Shield, ENRGY 3, HA FescoBoard (homogeneous) or HA BP -AA BP -AA or SBS-TA, -45.0* plank deck Elastobase Poly, Loc-Nails staggered center Polytherm or Multi- min. 0.5-inch Structodek High APP-TA APP-TA Polyglass G2 Base Density Fiberboard Roof rows Max FA3, Insulation 'E 6C -GYPSUM DECKS RERQqF (TEAR 0 TABLE FFWbR k6DWR 7 MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER System Deck (Note 1) Base Insulation Top Insulation Layer Roof Cover (Note IS) MDP Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply No. Layer (Psq (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Existing sound more layers, any Prime or SECU ROCK Gypsum -Fiber Trufast Twin Loc- 2 (Optional if (Optional if using AA Base) One SBS-AA, SBS- G-10 poured gypsum or combination, loose Roof Board or min. 0.5-inch Nails (min. 1-inch I per 2 ft using AA Ply) or more BP -AA or APP-TA TA, APP-TA -45.0* gypsum plank deck laid Structodek High Density Fiberboard embedment) BP -AA Roof Insulation _7 RikOOF &EAR64)24-' SYSTEM TYPE E: NON'iNSuiArb)' MECHANICALLY ATTACHED. BASE SHEEt;".B6NIJED'ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners (Note 11) Attach Base Ply Cap Ply (Psf) Existing sound poured Polyglass Elastobase, Polyglass Elastobase Trufast FM-75 or FM-90 or 9-inch o.c. in 4-inch lap and 18-inch o.c. in (Optional) One or more SBS-AA SBS-TA, G-11 gypsum or gypsum Poly, Polyglass G2 Base Twin Loc-Nails I two, equally spaced, staggered center rows BP -AA or APP-TA APP-TA -45.0* plank deck Exterior Research and Design, LLC. d/b/a Trinity) ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 eH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-148S Appendix 1, Page 24 of 26 F)o �l TRINITY I ERD TABLE7A: RECOVERAPPLICATIONS_ SYSTEM TYPE A-1: BONDED INSULATION; BONDED ROOF COVER' System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Substrate Type Attach Type Attach Base Ply Ply Cap Ply (psf) Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-1 asphaltic roof Min. 1.5-inch Multi -Max FA3 D-IS insulation and/or min. 0.25-inch D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -67.5 SECUROCK Gypsum -Fiber Roof Board Existing (Optional) additional layers(s) of base (Optional) One or more R 2 asphaltic roof Min. 2.0 pcf Insulfoam D-IS insulation D-IS SBS-SA SBS-SA SBS-SA, APP-SA -90.0 Existing Min.1.5-inch ACFoam II or ENRGY 3 or min. Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-3 asphaltic roof 2.0 pcf Insulfoam D-IS Roof Board D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -90.0 Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-4 Min.1.5-inch ACFoam II or ENRGY 3 D-IS insulation and/or min. 0.25-inch D-IS SBS-SA -90.0 asphaltic roof SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Existing (Optional) additional layers of base (Optional) One or more R-5 asphaltic roof Min.1.5-inch, min. 2.0 pcf Insulfoam OB500 insulation OB500 SBS-SA SBS-SA SBS-SA, APP-SA -120.0 R-6 Existing Min.1.5-inch, min. 2.0 pcf Insulfoam OB500 Min. 0.25-inch SECUROCK Gypsum -Fiber OB500 SBS-SA (Optional) One or more SBS-SA, APP-SA, -120.0 asphaltic roof Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Existing Min. 1.5-inch ACFoam II, ENRGY 3 or H- (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-7 OB500 insulation and/or min. 0.25-inch OB500 SBS-SA -127.5 asphaltic roof Shield SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Existing Min. 1.5-inch ACFoam II, ENRGY 3, H- M- (Optional) additional layers(s) of base M- (Optional) One or more SBS-SA, APP-SA, R 8 insulation and/or min. 0.25-inch SBS SA 157.5 asphaltic roof Shield or Multi -Max FA3 OSFA SECUROCK Gypsum -Fiber Roof Board OSFA SBS-SA or APP-TA SBS-TA or APP-TA R 9 Existing Min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers(s) of base CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA 240.0 asphaltic roof insulation SBS-SA Existing Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-10 asphaltic roof Min. 2.0 pcf Insulfoam CR-20 Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA _240.0 Min.1.5-inch Ultra -Max or Multi -Max FA-3, (Optional) additional layers(s) of base R-11 Existing min. 1.3-inch ACFoam III or min. 1.0-inch CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, -240.0 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA 3 Existing (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-12 asphaltic roof Min. 2-inch ACFoam II, ENRGY-3 or H-Shield CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -247.5 SECUROCK Gypsum -Fiber Roof Board Existing Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One more SBS-AA, SBS-TA or R-13 asphaltic roof Min.1.5-inch Multi -Max FA3 D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS SA, APP-TA BP -AA or APP-TA APP-TA -67.5 Board Existing Min.1.5-inch ACFoam II or ENRGY 3 or min. Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-14 D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS _g0.0 asphaltic roof 2.0 pcf Insulfoam Board SA, APP-TA BP -AA or APP-TA APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 25 of 26 \! TRINITY J ERD �. TABLE7A RECOVER CA ' ; ;; SYSTEM TYPEAA I ,BONDED INSULATION, B0 DED ROOF COVER ' System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Substrate (psf) Type Attach Type Attach Base Ply Ply Cap Ply Existing Min.1.5-inch ACFoam II, ENRGY 3, H-Shield Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-15 asphaltic roof or ISO 95+GL OB500 Prime or SECUROCK Gypsum -Fiber Roof OB500 SA, APP-TA BP -AA or APP-TA APP-TA _127.5 Board Existing Min.1.5-inch ACFoam II, ENRGY 3, H-Shield M- Min. 0.25-inch SECUROCK Gypsum -Fiber M- BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-16 asphaltic roof or Multi -Max FA3 OSFA Roof Board OSFA SA, APP-TA BP -AA or APP-TA APP-TA 157.5 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min. 1.3-inch ACFoam III or min. 1.0-inch Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more R-17 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY CR-20 Roof Board CR-20 BP -AA BP -AA SBS-AA -225.0 3 or min. 2.0 pcf Insulfoam Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min.1.3-inch ACFoam III or min. 1.0-inch Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more R-18 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY CR-20 Roof Board CR-20 APP-TA APP-TA APP-TA -232.5 3 or min. 2.0 pcf Insulfoam -�" , -7ABLE76: RECOVER APPLICATIONS*,;,. SYSTEM TYPE F NCIN-INSULATE D,:BOND IED BASE SHEET, BONDED,ROOFCOVER System Deck Primer Roof Cover (Note 15) MDP Base Ply Ply Cap -Ply No. P( Sf) R-19 Existing asphaltic roof ASTM D41 BP -AA (Optional if using asphalt applied Ply)_ _(Optional -if usin gasphat aipplied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA 45.0 Exterior Research and Design, I.I.C. d/b/a Trinity( ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 26 of 26 i M11A1Nl t � - MIAMI-DADE COUNTY PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Gardner Asphalt Corporation 4161 W. 7" Avenue Tampa, FL. 33605 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Gardner Underlayments LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales; advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 15-0707.09 and consists of pages 1 through 5. The submitted documentation was reviewed by Alex Tigera. NOA: 17-0427.10 Expiration Date: 03/28/18 Approval Date: 08/31/17 Page 1 of 5 ROOFING COMPONENT APPROVAL Category: Roofing Sub -Category: Underlayment Material: Asphalt TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description APOCjuff"Felf26i (36"_ x`.72.' roles ASTIYI'D 226"Type I� sphalt_Satur�a ed`Felt underlayrn__ 12} f11^inntirivio Square #30;1 (Location91, United FGUR20 36" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 2 Manufacturing square #30. Location #1, 2 APOC Tuff -Felt 46 36" x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 Manufacturing square # 15. Location 91, 2 United FGUR10 36" x 144' rolls ASTM D 226 Type I Asphalt Saturated Felt underlayment, 4 Manufacturing square # 15. Location #1, 2 United FGUR70 18" x 72' rolls ASTM D 226 Type II Asphalt Saturated Felt underlayment, 1 Manufacturing square #30. Location #1, 2 GatorSkin 42" x 285.8' rolls ASTM D 226 Type II Synthetic roof underlayment comprised Manufacturing of layers of polyolefin film. Location 43 Weather -Armor CX-L 37.25" x 145' rolls ASTM D 226 Type II High strength hybrid underlayment Manufacturing comprised of two layers of polyolefin and Location #3 polyester synthetic fabric with a thin layer of modified bitumen between the two plies. Weather -Armor SB-1 36" x 65' 8" rolls ASTM D 1970 Glass fiber reinforced, polymer modified Manufacturing asphalt, granulated self -adhered Location #4 underlayment. Weather -Armor HV 39" x 65' 8" rolls ASTM D 1970 60-mils thick (nominally), self -adhering Manufacturing membrane composed of elastic polymers, Location #4 bitumen, glass reinforcements and a cross laminated sheet surfacing. NOA: 17-0427.10 Expiration Date: 03/28/18 Approval Date: 08/31/17 Page 2 of 5 TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Test Product Product Dimensions Specification Description Weather -Armor FT3 39" x 65' 8" rolls TAS 103 60-mils thick (nominally), self -adhering Manufacturing membrane composed of elastic polymers, Location #4 bitumen polyester and glass reinforcement. MANUFACTURING LOCATIONS: 1. Tacoma, WA. 2. Eutaw, AL. 3. Hangzhou, China. 4. Springville, AL. EVIDENCE SUBMITTED: Test Agency Test Identifier Test Name/Report Date PRI Construction Materials GGI-100-02-01 ASTM D 226 06/22/12 Technologies GGI- 10 1-02-01 ASTM D 226 06/22/12 GGI-132-02-01 ASTM D 226 04/28/15 GGI-176-02-01 ASTM D 226 09/26/16 GGI-178-02-01 ASTM D 1970 10/25/16 GGI-194-02-01 ASTM D 1970 08/04/17 GGI-196-02-01 TAS 103 08/08/17 APPROVED ASSEMBLIES: Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened to deck. Anchor Sheet: One or more plies of APOC Tuff -Felt 26, United FGUR20, United FGUR70, GatorSkin, or Weather -Armor CX-L with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. NOA: 17-0427.10 Expiration Date: 03/28/18 Approval Date: 08/31/17 Page 3 of 5 Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(2): Anchor sheet mechanically fastened to deck. Anchor Sheet: Minimum 2 plies or more of APOC Tuff -Felt 46, or United FGUR10 with a minimum 19" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6 inches o.c. minimum at all laps and three staggered rows fastened at 12 inches o.c. minimum in the field of the roll. Nails shall be driven flush and 90 degrees to the roof deck. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof applications, and as an anchor sheet in roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(3): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Weather -Armor SB-1, or Weather -Armor HT self -adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, and metal roof applications. Must Comply with applicable Roofing Application Standards and Building Codes. Deck Type 1: Wood, Non -insulated Deck Description: 19/32" or greater plywood or wood plank System E(4): Anchor sheet mechanically fastened to deck, membrane adhered. Anchor Sheet: One or more plies of ASTM D 226 Type II or ASTM D 2626 with a minimum 4" headlap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c. at the side lap edge and in a grid pattern spaced 12" o.c. in the field of the roll. Membrane: One or more plies of Weather -Armor FT' self -adhering membrane adhered to the anchor sheet with a minimum 3" headlap and 6" end lap. Surfacing: Shall be acceptable for use in approved asphaltic shingles, wood shakes, & shingles, quarry slate, metal roof, and mechanically fastened roof tile applications. Must Comply with applicable Roofing Application Standards and Building Codes. NOA: 17-0427.10 Expiration Date: 03/28/18 Approval Date: 08/31/17 Page 4 of 5 LABELING: All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city, state and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below. BUILDING PERMIT REQUIREMENTS: Application for building permit shall be accompanied by copies of the following: 1. This Notice of Acceptance. 2. Any other documents required by the Building Official or applicable building code in order to properly evaluate the installation of this material. LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. 3. Weather -Armor SB-I, and Weather -Armor HT shall not be hot mopped; refer to manufacturer's published literature for product compatibility. 4. Gardner Underlayments listed herein are components used in roof assemblies. Roof assemblies are approved under specific assembly Notice of Acceptance. 5. APOC-Tuff Felt 26, United FGUR20, APOC-Tuff Felt 46, United FGUR10, United FGUR70, GatorSkin, Weather Armor CX-L, and Weather -Armor SB-1 listed herein shall not be left exposed as a temporary roof for longer than 30 days of application. 6. Weather -Armor HT3 and Weather -Armor FT listed herein shall not be left exposed as a temporary roof for longer than 180 days of application. 7. Gardner Underlayments listed herein may be used with any approved roof covering Notice of Acceptance listing Gardner Underlayments listed herein as a component part of an assembly in the Notice of Acceptance. If Gardner Underlayments listed herein is not listed; a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results. 8. For fire classification of specific roof assemblies using Gardner Underlayments listed herein refer to a current Approved Roofing Materials Directory for fire ratings of this product. 9. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE NOA: 17-0427.10 Expiration Date: 03/28/18 Approval Date: 08/31/17 Page 5 of 5