Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL METAL ROOFING1/22/2018 Florida Building Code Online SCANNED BY St Lucie County r�r�r BCIS Home I Log In I User Registration I Hot Topics I Submit Surcharge I Stats & Facts I Publications I FBC Staff I BCIS Site Map I Links I Search I Florida r alla=ueb Approval lic User E Nc?��anlysm Product Approval Menu > Product or Application Search > Application List > Application D RECEIVED OFFICE • FL # FL11651-R3 nn o SECRETARY Application Type Revision FFD 2 ®2.048 Code Version 2017 ! Application Status Approved ST. Lucle County, Permitti Comments Archived O Product Manufacturer I Gulf Coast Supply & Manufacturing, LLC. Address/Phone/Email 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352)498-0778 I Info@gulfcoastsupply.com I Authorized Signature Ray Bowen info@gulfcoastsupply.com Technical Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 Mamma (352) 0778 lnfo@gulfcoastsupply.com oasts f nfo@g u Ifcoastsupply.com Quality Assurance Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer D Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Daniel S. Kuhn PE-75519 Keystone Certifications, Inc. 04/12/2024 Locke Bowden O Validation Checklist - Hardcopy Received FL11651 R3 COI Cert of Independence 2017-10-09,pdf Referenced Standard and Year (of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 LIL 1897 2012 https://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnAp/o3d%3d 1/5 1/22/2018 Florida Building Code Online UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Method 1 Option D Date Submitted 10/10/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products Go to Page 0 0 Pagel/ 20 0 FL # I Model, Number or Name 11651.1 1 0.032" Aluminum 5V Crimp Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @ 12" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.2 1 0.032" Aluminum Gulf Lok Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. ,11651.3 1 1" 24ga. Gulf Snap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--131.OPS Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.4 1 1" 24ga. VersaLoc Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -71 psf @ 24" o.c. clip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones, 11651.5 1 1" VersaLoc .032" Aluminum Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Description Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 1 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 1 R3 0325vCrimo 15- 32Pivwood NonHVHZ-signed.odf Created by Independent Third Party: Yes Min 0.032" Aluminum Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 2 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 2 R3 032GuIfLok 16 15- 32Plvwood NonHVHZ-signed.ndf Created by Independent Third Party: Yes 1" Gulf Snap 24 Ga. 17' wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 3 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 3 R3 1 24GulfSnao 17 15- 32Plvwood HVHZ-sioned.odf Created by Independent Third Party: Yes 1" VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 4 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 4 R3 24VersaLoc SR 16.5 15- 32Plvwood HVHZ-sianed.odf Created by Independent Third Party: Yes 1" VersaLoc min .032" Aluminum over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 5 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 hops://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFG5K%2frZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnA%3d%3d j!� 1 /22/2018 Florida Building Code Online Design Pressure: +N/A/ -If PSF Other: -63.3 psf @ 24" o.c. ty%ispacing. -101.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.6 1 1.5" 24ga. Gulf Snap Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.OPSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers detals. For use in HVHZ Zones. 11651.7 1 1.5" 24ga. VersaLoc Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" o.c. clip spacing. -123.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. For use it HVHZ Zones. 11651.8 12" 24ga. MegaLoc Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Indepe t Third Party: Yes Evaluation ReporW FL11651 R3 AE FL11651 5 R3 lin 032VersaLoc SR 16 15-32Pivwood HVHZ-sioned.pdf Created by Independent Third Party: Yes 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 6 R3 Metal Roof Panel Detail- sioned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 6 R3 1.5 24GulfSnap 16 15- 32Pivwood HVHZ-sianed.pdf Created by Independent Third Party: Yes 1.5" Versal-oc min 24ga. 16" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 7 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 15- 32Plvwood HVHZ-signed.pdf Created by Independent Third Party: Yes Min 24 Ga. 2" MegaLoc 18" wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 8 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 8 R3 24VersaLoc 18 15- 32Pivwood NonHVHZ-signed.pdf Created by Independent Third Party: Yes 11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 9 R3 Metal Roof Panel Detail - sioned.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-96.7PSF Created by Independent Third Party: Yes Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf Evaluation Reports @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8" fastener FL11651 R3 AE FL11651 9 R3 24GulfLok 16 15- 32Pivwood NonHVHZ-signed.pdf spacing. -161 psf @ 5-1/8" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.10 124 Ga. Gulf Seam Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5PSF Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. 11651.11 124 Ga. Gulf Seam Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 10 R3 Metal Roof Panel Detail- signed.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 10 R3 24GulfSeam 16 1x4 15- 32Pivwood NonHVHZ-signed.pdf Created by Independent Third Party: Yes Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 11 R3 Metal Roof Panel Detail- sioned.pdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 11 R3 24GulfSeam 18 15- 32Plvwood NonHVHZ-sioned.odf Created by Independent Third Party: Yes https://floridabuilding.org/prlpr ppp_dti.aspx?param=wGEVXQwtDgsQFc5K°/a2frrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d 3/5 1 /22/2018 Florida Building Code Online 11651.12 126 iV Crimp Min 26 Ga. 5V Crin Df Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651 R3 II FL11651 12 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 12 R3 265vCrimo 15- 32Plvwood HVHZ-sioned.pdf Created by Independent Third Party: Yes 11651.13 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 13 R3 Metal Roof Panel Detail - signed.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-131.PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ Evaluation Reports 16" o.c. fastener pattern. Install per manufacturers details. FL11651 R3 AE FL11651 13 R3 265vCrimo 15- 32Piywood NonHVHZ-sioned.odf Not for use in HVHZ Zones. Created by Independent Third Party: Yes 11651.14 126 Ga. 5V Crimp Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.5PSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. Min 26 Ga. 5V Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 14 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 14 R3 265vCrimo 1x4 15- 32Plywood NonHVHZ-signed.odf Created by Independent Third Party: Yes 111651.15 126 Ga. Gulf Lok I Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-161.OPSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. 11651.16 126 Ga. Gulf Lok Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5PSF Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. 11651.17 126 Ga. GulfPBR Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf @ 12" o.c. fastener pattern. Install per manufacturer details. Not for use in HVHZ 11651.18 126 Ga. GulfPBR Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" o.c. fastener spacing.-151.75 psf @ 12" fastener spacing. Install per manufacturer's details. For use in HVHZ Zones Installation Instructions FL11651 R3 II FL11651 15 R3 Metal Roof Panel Detail- signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 15 R3 26GulfLok 16 15- 32Plvwood HVHZ-signed.ndf Created by Independent Third Party: Yes Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 16 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 16 R3 26GulfLok 16 15- 32Plywood NonHVHZ-sioned.odf Created by Independent Third Party: Yes Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 17 R3 Metal Roof Panel Detail- sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 17 R3 26GulfPBR 15- 32Plvwood NonHVHZ-signed.odf Created by Independent Third Party: Yes Min 26 Ga. GulfPBR Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Installation Instructions FL11651 R3 II FL11651 18 R3 Metal Roof Panel Detail- sianed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 18 R3 26GulfPBR 1x4 15- hftps://floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d 4/5 1 /22/2018 Florida Building Code Online 32Plvwood HVHZ-,_ LAE - Created by IndepE.r.��,tThird Party: Yes 11651.19 26 Ga. GUIfPBR Min 26 Ga. GulfPBR over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 II FL11651 19 R3 Metal Roof Panel Detail - sioned.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By. Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-154.7PSF Created by Independent Third Party: Yes Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @ Evaluation Reports 12" o.c. fastener spacing. Install per manufacturer's details. FL11651 R3 AE FL11651 19 R3 26GulfPBR 15- For use in HVHZ Zones. 32Plywood HVHZ-signed.Ddf Created by Independent Third Party: Yes 11651.20 26 Ga. GUIfPBR Min 26 Ga. GUIfPBR over lx4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail - sioned.odf Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-151.7PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf @ Evaluation Reports 12" fastener spacing. Install per manufacturer's details. Not for FL11651 R3 AE FL11651 20 R3 26GulfPBR lx4 15- 32Plvwood NonHVHZ-signed.Ddf use in HVHZ Zones Created by Independent Third Party: Yes Go to Page " fal Back Next 110 4) Page l / 20 0 Contact Us :: 2601 Blair Stone Road. Tallahassee FL 32399 Phone: 850-487-1824 The State of Florida is an AA/EEO employer. Copyright 2007-2013 State of Florida.:: Privacy Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a public -records request, do not send electronic mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address If they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine If you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: ® ® rig eCheck Credit Card Safe https://floridabuilding.org/prlpr app_dti.aspx?param=wGEVXQwtDgsQFc5K%2frrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnAg/o3d%3d 5/5 Product Evaluation Report GULF COAST SUPPLY & MANUFACTURING, LLC 26 Ga. SV Crimp Roof Panel over 15132" Plywood Florida Product Approval #11651.13 R3 Florida Building Code 2017 Per Rule 61 G20-3 Method: 1 -D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 %%•%'Pr11F-L, S��j�G,,� Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 - 5 FL# 11651.13 R3 • OCTOBER 5, 2017 O•'�`GENS� - No. 75519 = STATE OF •'Q: �O�FSi A%� 0 R 10 P' • •���.' NAL EN.�o/os/2oZj '�IIII,,,,` Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: 5V Crimp Roof Panel, 26 Ga. Steel, 24" Coverage, through fastened roof panel with fasteners in the panel flat over minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 80.0 ksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 24" Coverage Rib Height: 3/8" Major Rib Panel Fastener: #9-15x1.5" with sealing washing in the flat of the panel or approved equal, 1/4" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Substrate Description: Minimum t5/32" thick, APA Rated plywood over supports at maximum 24" O.C. Design .of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Design Uplift Pressures: FL# 11651.13 R3 9 OCTOBER 5, 2017 Table "A" Maximum Total Uplift Design Pressure 94.25 psf 131.0 psf Fastener Pattern 12"-12" 9.5"-2"-9.5" Fastener Pattern Spacing 16" O.C. 16" O.C. Design Pressure includes a Safety Factor = 2.0. Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report -No. 117-0053T05 & 117-0331T08 2. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL# 11651.13 R3 9 OCTOBER 5, 2017 , a W Zr, *' NO. W�-- \.. - Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL# 11651.13 R3 9 OCTOBER 5, 2017 ENGINEER LOAD TABLE: 26 Ga. SVCrimp Roof Panel over 15/32" Plywood Buildings having a Roof Mean Heights 20'-0"; Roof Slope: 2"/12" - 12"/12" Gable or Hip Roof, Wind Speeds 120- 180mph, Exposure C, Risk Category II, Enclosed Building, based on Florida Building Code 2017. 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN.114" penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1 #9-15x1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 ZONE 2 #9-15x1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 ZONE 3 #9-15x1.5" Plywood 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 1 16" TYPE 2 16" TYPE 2 1.) PANEL DESCRIPTION: 5V CRIMP, MIN. 26 GA., GRADE 80, 24"COVERAGE. 2.) PANEL FASTENER: #9-15X1.5" HWH WITH SEALING WASHER W/ MIN. tA" PENETRATION. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -94.25 PSF@ 16" O.C. FASTENER SPACING TYPE 1 FASTENER PATTERN, -131.0 PSF @16" O.C. FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.) PLYWOOD DECKING: MIN. 75h2" THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2017. 5.) ROOF SLOPE: ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. Z HIP ROOF a Note: Dimension (a) is defined as 10% of the minimum width of the building or ---- ZONE 3 ' rl a 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be �- — — — — — — — — — , less than either4% of the minimum width of the building or 3 feet. \� RIDGE . , ---------- ---------- ZONE1 ----------------- Z GABLE ROOF ----------------1� —a I I RIDGE 1--------------------- ZONE 1 I I----------------------1 -ZONE 3 `-EAVE FL# 11651.13 R3 9 OCTOBER 5, 2017 TYPE 1 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer 12" 12"� At Panel Lap �� TYPE 2 FASTENER PATTERN (1) #9-15 x 1-1/2" HWH w/Sealing Washer