HomeMy WebLinkAboutENGINEERING SUBMITTALSCANNED
BY
St Lucie County 25%I8
ENGINEERING SUBMITTALS
February 6, 2018
WM LOAD CERTIFICATION:
CODE FBC 2017 6TH ADDITION/ FRC 2017/ ASCE 7-10
9
WIND SPEED: 170 mph, 3 SEC. GUST,
EXPOSURE:"D"
IMPORTANCE FACTOR: 1.0
INTERNAL PRESSURE COEFF.: �M / rOZ .d
� , Luc COUNTY BUMDIN�G DMSION
jhEV D DO CE
i KN D
UATE
Li ERWT MUST BE KEPT ON JOB
OrkNO INSPECTION WILL BE MADE.
JOB:
NEIL RESIDENCE
3119 S. INDIAN RIVER DR.
FORT PIERCE, FL
THESE PLANS AND ALL PROPOSED WORK
ARE SUBJECT tJ ANY CORRECTIONS
CONCEALED FASTENERS OR ATTACHMENTS
REQUIRED BY FIELD INSPECTORS THAT
ARE THE RESPONSIBILITY OF THE
MAY BE NECESSARY IN ORDER TO
.
COMPLY WITH A6L APPLIGAOLF CODES.
CONTRACTOR OF RECORD
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email — pwelchincgaol.com
Paul Welch, P.E. Fla Reg. No. 29945
File COPS'
1rt x 12'tBOAT LIFT N
1
MOORINGAREA y 1
WITH OPTIONAL \ 5 1 \y 1 INDIAN RIVER
12't X 12't BOAT LIFT 1 y \I WATERBODY WIDTH
y \ \ y 9,800't
\ 20' 1ZZ
-2-
1 \ •� y -
1 1 \\ \
1 1 11 TURBIDITY CURTAIN
11 ; 240
\ \ y 1
\ y y \
1 1 \ \
1 25 \ yy APPROXIMATE
RIPARIAN LINE
APPROXIMATE \ 1 \ \
RIPARIAN LINE
\ \
\ \ \ APPROXIMATE
\ y \y .MEAN HIGH WATER LINE
\ 1 \ y
\ 1 \ 1
1 y 1
1 \ �
1 R
/ STAIRS LANDWARD OF
�R . L\NELENG� MEAN HIGH WATER LINE
SNOpTtI.F•
�....
MECH-ELECT-CIVIL ENG.
1984 BILTIVIO RE ST. #114
PORT SAINT LUCIE, FL 34984
PROPOSED PLAN VIEW
BRIAN & LISA NEIL
PAUL WELCH R.E.
3u9 S INDIAN RIVER DRIVE
FLA REG NO.29945
FORT PIERCE, FL '
PCN# 2426-122-005-000-4
FEB 062018
H3LE HAND KAIL
ACCESS
IG W/ 1/2" SPACING
1/2- SS
MHW
MLW
MECH-ELECT-CIVIL ENG. Dock Access Cross Section View
1984 BILT-bif' 'E ST. #114
PORT SAINT LUCIE; FL $4984. Brian and Lisa Neil
PAUL WELCH P.E. 3119 S. Indian River Drive
FLA REG NO.29945 Fort Pierce, Florida
PCN# 2426-122-0006-000-4
.r
FEB 0 6 2018
r r l
r, r
MLW
2x6 DECKING W/ 1/2-
SCREWED 3I/2- S;
PAUL WELCH INC.
MECH-ELECT-CIVIL ENG.
1984 BILT;v)09E ST. #114
PORT SAINT LUCIE, FL 34984
PAUL WELCH P.E-
FLA REG NO.29945
Platform Cross .Section View
Brian and Lisa Neil
3119 S. Indian River Drive
Fort Pierce, Florida
PCN# 2426-122-0005-000-4
IBOLTS
FEB 062018
=6 PRESERVE PLUS CAP
xx4 P.T.
I
rFI.,.
LATFORM
R.O.W.
STAIR CASE DETAIL
2x2 P.T. PICKETS 47 O.C.
GRASPABLE HARALL2x2
ND HARAILING BOTH SIDES
— ALL SS FASTENERS
ND
PLATFORM DUG into l�
GROUND
STAIRS FLUSH w/
EXISTING GRADE 2x4 P.T. STRINGERS
5/8.GALV LAGS ALL MEMBERS
8' WOOD PILINGS 06 WASHERS
PAUL WELCH INC.
MECH-ELECT-CIVIL ENG.
1984 BILTV101?E ST. #114
PORT SAINT LUCIE, FL 34984,
PAUL WELCH P.E.
FLA REG NO.29945
LESS THAN i
12 PENNY SS FASTENERS DOCK
ALL MEMBERS
2x8 CROSS MEMBERS
SS or GALV THRU BOLTS
ALL MEMBERS
12' —
MINIMUM S' PENETRATION INTO
SEABOTTOM
PROPOSED STAIRCASE DETAIL
BRUN & LISA NEIL
3n9 S INDIAN RIVER DRIVE
FORT PIERCE, FL
PCN# 2426-122-0005-000-4
8' PILING
r
0
FEB '0 6 2018